首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 125 毫秒
1.
The purpose of this study was to compare the sensitivity of different magnetic resonance imaging (MRI) sequences to depict periosteal edema in patients with medial tibial pain. Additionally, we evaluated the ability of dynamic contrast-enhanced imaging (DCES) to depict possible temporal alterations in muscular perfusion within compartments of the leg. Fifteen patients with medial tibial pain were examined with MRI. T1-, T2-weighted, proton density axial images and dynamic and static phase post-contrast images were compared in ability to depict periosteal edema. STIR was used in seven cases to depict bone marrow edema. Images were analyzed to detect signs of compartment edema. Region-of-interest measurements in compartments were performed during DCES and compared with controls. In detecting periosteal edema, post-contrast T1-weighted images were better than spin echo T2-weighted and proton density images or STIR images, but STIR depicted the bone marrow edema best. DCES best demonstrated the gradually enhancing periostitis. Four subjects with severe periosteal edema had visually detectable pathologic enhancement during DCES in the deep posterior compartment of the leg. Percentage enhancement in the deep posterior compartment of the leg was greater in patients than in controls. The fast enhancement phase in the deep posterior compartment began slightly slower in patients than in controls, but it continued longer. We believe that periosteal edema in bone stress reaction can cause impairment of venous flow in the deep posterior compartment. MRI can depict both these conditions. In patients with medial tibial pain, MR imaging protocol should include axial STIR images (to depict bone pathology) with T1-weighted axial pre and post-contrast images, and dynamic contrast enhanced imaging to show periosteal edema and abnormal contrast enhancement within a compartment.  相似文献   

2.
The purpose of this study was to evaluate the diagnostic accuracy of MR cholangiopancreatography (MRCP) in the detection of common bile duct stones. A series of 286 consecutive patients were referred for MRCP, that was performed with a 1.5 T MR unit, through a non-breath-hold, respiratory-triggered, fat-suppressed, two-dimensional, heavily T2-weighted fast spin-echo sequence in the coronal plane. Axial T1 and T2-weighted sequences were first obtained. Axial, coronal, and Maximum Intensity Projection images were evaluated by three independent readers, who were asked to determine whether stones were present or not inside the biliary tract. The findings of MRCP images were compared with endoscopic retrograde cholangiopancreatography, percutaneous trans-hepatic cholangiography, intra-operative cholangiography, surgical, or imaging follow-up findings. Two-hundred and seventy-eight out of 286 MRCP examinations were judged diagnostic by the three reviewers. Among the 278 patients included in our study group, biliary tract lithiasis was proved in 76 cases (27%). On the basis of reviewers' reading, MRCP had sensitivity 92-93%, specificity 97-98%, positive predictive value 91-93%, negative predictive value 97-98%, and the diagnostic accuracy ranged between 95% and 96% in the detection of calculi. Interobserver agreement was excellent (K = 0.84, kappa statistic). MRCP showed a high diagnostic accuracy and an excellent inter-observer agreement in the detection of common bile duct stones.  相似文献   

3.
The purpose of this study was to investigate the feasibility of diffusion-weighted imaging (DWI) in detecting synovitis of wrist and hand in patients with rheumatoid arthritis (RA) and evaluate its sensitivity, specificity and accuracy as compared to T2-weighted imaging (T2WI) with short tau inversion recovery (STIR) with the reference standard contrast-enhanced magnetic resonance imaging (CE-MRI). Twenty-five patients with RA underwent MR examinations including DWI, T2WI with STIR and CE-MRI. MR images were reviewed for the presence and location of synovitis of wrist and hand. The sensitivity, specificity and accuracy of DWI and T2WI with STIR were calculated respectively and then compared. All patients included in this study completed MR examinations and yielded diagnostic image quality of DWI. For individual joint, there was good to excellent inter-observer agreement (k = 0.62–0.83) using DWI images, T2WI with STIR images and CE-MR images, respectively. There was a significance between DWI and T2WI with STIR in analyzing proximal interphalangeal joints II–V, respectively (P < 0.05). The k-values for the detection of synovitis indicated excellent overall inter-observer agreements using DWI images (k = 0.86), T2WI with STIR images (k = 0.85) and CE-MR images (k = 0.91), respectively. Overall, DWI demonstrated a sensitivity, specificity and accuracy of 75.6%, 89.3% and 84.6%, respectively, for detection of synovitis, while 43.0%, 95.7% and 77.6% for T2WI with STIR, respectively. DWI showed positive lesions much better and more than T2WI with STIR. Our results indicate that DWI presents a novel non-invasive approach to contrast-free imaging of synovitis. It may play a role as an addition to standard protocols.  相似文献   

4.
The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an unenhanced T(1)-weighted (T1W), T(2)-weighted (T2W), STIR, and Ferumoxide-enhanced hepatic MRI. Following these studies, a laparotomy was performed and the liver was evaluated by palpation and intraoperative ultrasound. Two observers who were blinded to surgical results evaluated each MR sequence separately. The number of lesions considered highly suspicious for metastatic lesions were determined for each sequence and were compared to the results of surgery. The McNemar test was used to compare the outcomes of the different sequences. MR Imaging was unable to detect small (<5 mm) metastases discovered at surgery. The best non-contrast sequences for detecting metastases were the STIR with 42% sensitivity, 83% specificity and an overall accuracy of 56% and the T1W sequence (sensitivity 38%, specificity 100%, accuracy 57%), which were not significantly different (p 0.4). The noncontrast T2W sequence had a sensitivity of 29% and a specificity of 77% with an overall accuracy of 46%. When all pre contrast scans were grouped together the common sensitivity was 42%, specificity was 77% and accuracy was 54%. The post-ferumoxide T(2)W scans had a sensitivity of 42%, specificity of 85%, and accuracy of 57%, but did not detect any additional lesions. There was no statistical difference between the pre- and post-contrast studies with regard to identifying patients with metastatic disease (p 0.1). In conclusion, we found small hepatic metastases in patients with early signs of recurrent colorectal cancer are difficult to detect on MRI. Ferumoxide-enhanced MRI was unable to detect additional hepatic metastases and performed no better than unenhanced MRI in detecting small hepatic metastasis.  相似文献   

5.
We retrospectively examined MR images in 82 patients to evaluate the usefulness of short inversion time inversion recovery (STIR) in bone marrow imaging at 0.5 and 1.5 T. The study included 56 patients at 1.5 T and 26 patients at 0.5 T with a variety of pathologic bone marrow lesions (principally oncological), and compared the contrast and image quality of STIR imaging with spin-echo short repetition time/echo time (TR/TE), long TR/TE, and gradient-echo sequences. The pulse sequences were adjusted for optimal image quality, contrast, and fat nulling. STIR appears especially useful for the evaluation of red marrow (e.g., spine), where contrast between normal and infiltrated marrow is greater than with either gradient-echo or T1-weighted images. STIR is also extremely sensitive for evaluation of osteomyelitis, including soft tissue extent. In more peripheral (yellow) marrow, T1-weighted images are usually as sensitive as STIR. Limitations of STIR include artifacts, in particular motion artifact that at high field strength necessitates motion compensation. At 0.5 T, however, motion compensation is usually not necessary. Also, because of extreme sensitivity to water content, STIR may overstate the margins of a marrow lesion. With these limitations in mind, STIR is a very effective pulse sequence at both 0.5 and 1.5 T for evaluation of marrow abnormalities.  相似文献   

6.
Short TI inversion-recovery (STIR) imaging provides specific advantages over standard spin-echo (SE) MR sequences by producing additive effects of T1 and T2 brightening of pathology and suppression of the signal from surrounding fat. We retrospectively evaluated 12 patients with abnormalities, primarily neoplastic, of the porta hepatis/hepatoduodenal ligament (PH/HdL) with CT and MR imaging, including SE and STIR imaging. Masses on CT were of slightly decreased density compared to liver and seen in contrast to surrounding fat in the PH/HdL region. On MR, T1-weighted images provided comparable anatomic detail to CT, with masses clearly distinguished from surrounding fat due to the low signal intensity of masses as compared to fat. T2-weighted images clearly depicted intrahepatic lesions because of their high signal intensity relative to liver. Increased signal in extrahepatic lesions made them less distinctly seen from surrounding fat. STIR images best demonstrated tumor relative to fat. In six cases, CT was equivalent in demonstrating pathology to the best MR sequence. At least one MR sequence demonstrated pathology better than CT in 6 of 12 cases. In five of these six cases, the STIR sequence was better than CT. Thus, MR, particularly STIR imaging, provides a useful technique in imaging of PH/HdL pathology.  相似文献   

7.
OBJECTIVE: The objective of this study was to determine imaging features that may help predict the presence of placenta accreta, placenta increta or placenta percreta on prenatal MRI scanning. SUBJECTS AND METHODS: A retrospective review of the prenatal MR scans of 10 patients with a diagnosis of placenta accreta, placenta increta or placenta percreta made by pathologic and clinical reports and of 10 patients without placental invasion was performed. Two expert MRI readers were blinded to the patients' true diagnosis and were asked to score a total of 17 MRI features of the placenta and adjacent structures. The interrater reliability was assessed using kappa statistics. The features with a moderate kappa statistic or better (kappa > .40) were then compared with the true diagnosis for each observer. RESULTS: Seven of the scored features had an interobserver reliability of kappa > .40: placenta previa (kappa = .83); abnormal uterine bulging (kappa = .48); intraplacental hemorrhage (kappa = .51); heterogeneity of signal intensity on T2-weighted (T2W) imaging (kappa = .61); the presence of dark intraplacental bands on T2W imaging (kappa = .53); increased placental thickness (kappa = .69); and visualization of the myometrium beneath the placenta on T2W imaging (kappa = .44). Using Fisher's two-sided exact test, there was a statistically significant difference between the proportion of patients with placental invasion and those without placental invasion for three of the features: abnormal uterine bulging (Rater 1, P = .005; Rater 2, P = .011); heterogeneity of T2W imaging signal intensity (Rater 1, P = .006; Rater 2, P = .010); and presence of dark intraplacental bands on T2W imaging (Rater 1, P = .003; Rater 2, P = .033). CONCLUSIONS: MRI can be a useful adjunct to ultrasound in diagnosing placenta accreta prenatally. Three features that are seen on MRI in patients with placental invasion appear to be useful for diagnosis: uterine bulging; heterogeneous signal intensity within the placenta; and the presence of dark intraplacental bands on T2W imaging.  相似文献   

8.
Radiography of the chest is the most frequently performed radiological examination in pediatric imaging. However, it is associated with the application of ionizing radiation. In order to avoid ionizing radiation in children a new and very fast MRI technique has been developed at our center as an alternative to the pediatric chest X-ray. 100 patients who had received a chest X-ray were additionally investigated in a 0.2 T low-field MR-scanner by a modified true FISP sequence with an acquisition time of 3.6-4.6 s for a coronal triple-slice scan. X-ray and MR images were independently evaluated and later compared by two pediatric radiologists. Total investigation times (door-to-door time) for X-ray and MRI were comparable. The signal-to-noise ratio for lung parenchyma was 4.6-7.3. Of 189 pathologic findings 165 were depicted on MR images as well as radiographs, 18 were noted on MRIs only, 6 on X-rays only. Overall kappa was 0.87. True FISP MRI may be a good alternative to conventional chest X-ray. The main advantages are: fast imaging free of ionizing radiation, easy performance, no need for special equipment, optional imaging in all 3 planes, good image quality, and a high diagnostic value.  相似文献   

9.
Venous thrombus is subsequently organized and replaced by fibrous connective tissue. However, the sequential changes in venous thrombi are not reliably detected by current noninvasive diagnostic techniques. The purpose of this study is to reveal whether magnetic resonance (MR) can detect venous thrombus, define thrombus age and predict thrombolytic responses. Thrombus in the rabbit jugular vein was imaged with a 1.5-T MR system at 4 h and at 1, 2 and 4 weeks using three-dimensional (3D) fast asymmetric spin echo T2-weighted (T2W) and 3D-gradient echo T1-weighted (T1W) sequences. The jugular veins were histologically assessed at each time point. Magnetic resonance imaging (MRI) was also performed in vivo before and 30 min after tissue plasminogen activator (t-PA) administration. The thrombi in MRI were comparable in size to histological sections. The signal intensity (SI) of thrombi at 4 h was heterogeneously high or low on T2W or T1W images, respectively. The SI of thrombi on T2W images decreased time-dependently, but increased on T1W images at 1 and 2 weeks. Morphological analysis showed time-dependent decreases in erythrocyte, platelet and fibrin areas and time-dependent increases in smooth muscle cell, macrophage, collagen and iron areas. The t-PA administration significantly decreased thrombus volume at 4 h but not at 1, 2 and 4 weeks. Venous thrombosis can be reliably and noninvasively detected by MRI. Measurement of SI might support assessments of thrombus age and thrombolytic response.  相似文献   

10.

Purpose

Lesions close to the internal craniocervical ligaments are a common problem in patients with whiplash injuries. The aim of this study was to evaluate the morphology and visibility of these ligamentous structures with a new isotropic three-dimensional (3D) turbo-spin-echo (TSE) technique.

Materials and Methods

MR (MR) images of the cervical spine of 52 healthy subjects (27 women and 25 men; mean age=29 years; age range=18–40 years) were taken with a T2-weighted 3D TSE sequence with variable flip-angle distribution [SPACE (Sampling Perfection with Application optimized Contrasts using different flip-angle Evolution)] at 1.5 T (Magnetom Avanto, Siemens Erlangen, Germany). Two experienced musculoskeletal radiologists read the images independently on a 3D imaging and postprocessing workstation. The visibility and morphology of the alar ligaments were evaluated on a five-point scale, and inter-reader correlation was assessed with kappa statistics.

Results

Both alar ligaments were detected in all subjects. Twenty-eight (53.8%) of the alar ligaments could not be seen within one slice of the standard coronal imaging plane but could adequately be visualized in an oblique reconstruction adapted to the orientation of the ligaments on the axial slices. Inter-reader correlation for visibility on MR imaging (MRI) of the internal craniocervical ligaments was high (left+right side, kappa=0.95). Most (94%) alar ligaments presented symmetrically. In the axial plane, 60% were oriented neutral and 40% had a backward orientation. In the coronal plane, 67% were oriented caudocranially and 33% were oriented horizontally. The shape of the ligaments was parallel in half and was V-shaped in the other half. The alar ligaments had homogeneous low-signal intensity in 56% and heterogeneous low-signal intensity in 44%. The apical ligament of the dens was seen (excellent–good–moderate) in 61% (reader 1) and 52% (reader 2). The tectorial membranes and the transverse ligament of the atlas were shown (excellent–good) in all subjects.

Conclusions

MRI with acquisition of an isotropic SPACE technique allows high-resolution imaging of the craniocervical ligaments in all orientations. Reconstruction of the image data in the variable orientation of the alar ligaments allowed for excellent depiction within one slice such that partial volume artifacts that hamper image analysis can be eliminated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号