首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The pituitary of the B6C3F1 hybrid strain mice were irradiated with 0.05 Gy of ^60Co γ-ray as the pre-exposure dose (D1), and were then irradiated with 2 Gy of ^60Co γ-ray as challenging irradiation dose (D2) at 4h after per-exposure. Body weight and serum growth hormone (GH) were measured at 35th day after irradiation. The results showed that irradiation of mouse testes with 2 Gy of ^60Co γ-ray significantly diminished mousebody weight and level of serum GH (Table). Pre-exposure with a low-dose (0.05 Gy) of ^60Co γ-ray significantly alleviated reductions of mouse body weight and level of serum GH induced by subsequent a high-dose (2 Gy) irradiation (Table). The data suggested that low-dose ionizing irradiation can induce adaptive responses to the harmful effects of pituitary by subsequent high-dose exposure.  相似文献   

2.
To investigate the effects of pre-exposure of mouse pituitary with low-dose ^60Co γ-ray on male reproductive endocrine capacity induced by subsequent high-dose irradiation, the pituitary of the B6C3F1 hybrid strain male mice were irradiated with 0.05 Gy of ^60Co γ-ray as the pre-exposure dose (D1), and were then irradiated with 2 Gy of ^60Co γ-ray as challenging irradiation dose (D2) at 4 h after per-exposure. Pituitary gonadotroping hormones --follicle-stimulating hormone (FSH) and luterinzing hormone (LH), serum testosterone, testis weight and sperm count were measured at 35th day after irradiation.  相似文献   

3.
We have collected 18γ-ray-loud BL Lac with observed data in multiwavedand,we find that γ-ray flux densities correlate better with the near-IR flux densities than those with the optical or x-ray flux densities.There is no correlation between γ-ray and radio flux densities.Possible constraints on the γ-ray emission mechanism are discussed.We suggest that the main γ-ray radiation mechanism is probably the synchrotron self-Compton process.The inverse Compton scattering of the radiation from hot circumscribe dust.by beamed ultrarelativistic electrons,is likely to be an important complementary mechanism.  相似文献   

4.
A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of ~(131)I with volume/mass of thyroid,for water,ICRP- and ICRU-soft tissue taken as thyroid material.A Monte Carlo model of the thyroid,in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume.The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical,ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm~3 range.The relative differences of Geant4 results for different models with each other and MCNP results he well below 1.870%.The maximum relative difference among the Geant4estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%.S-values for ellipsoidal,spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within3.095%.The absorbed fraction values for beta particles show a good agreement with published values within 2.105%deviation.The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results(±6.667%) but have 29.032%higher values than that of MIRD calculated values.Consistent with previous studies,the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose.Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially diiferent from MIRD8 data.Therefore,inclusion of size/mass dependence is indicated for ~(131)I radiotherapy of the thyroid.  相似文献   

5.
A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (±6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for 131I radiotherapy of the thyroid.  相似文献   

6.
Radiation effects on complementary metal-oxide-semiconductor(CMOS) active pixel sensors(APS) induced by proton and γ-ray are presented. The samples are manufactured with the standards of 0.35 μm CMOS technology. Two samples have been irradiated un-biased by 23 MeV protons with fluences of 1.43 × 10~(11) protons/cm~2 and 2.14 × 10~(11) protons/cm~2,respectively, while another sample has been exposed un-biased to 65 krad(Si) ~(60)Co γ-ray. The influences of radiation on the dark current, fixed-pattern noise under illumination, quantum efficiency, and conversion gain of the samples are investigated. The dark current, which increases drastically, is obtained by the theory based on thermal generation and the trap induced upon the irradiation. Both γ-ray and proton irradiation increase the non-uniformity of the signal, but the nonuniformity induced by protons is even worse. The degradation mechanisms of CMOS APS image sensors are analyzed,especially for the interaction induced by proton displacement damage and total ion dose(TID) damage.  相似文献   

7.
The total dose radiation and annealing responses of the back transistor of Silicon-On-Insulator(SOI)pMOSFETs have been studied by comparing them with those of the back transistor of SOI n MOSFETs fabricated on the same wafer. The transistors were irradiated by60 Co γ-rays with various doses and the front transistors were biased in a Float-State and Off-State, respectively, during irradiation. The total dose radiation responses of the back transistors were characterized by their threshold voltage shifts. The results show that the total dose radiation response of the back transistor of SOI pMOSFETs, similar to that of SOI n MOSFETs, depends greatly on their bias conditions during irradiation. However, with the Float-State bias rather than the Off-State bias, the back transistors of SOI pMOSFETs reveal a much higher sensitivity to total dose radiation, which is contrary to the behavior of SOI n MOSFETs. In addition, it is also found that the total dose radiation effect of the back transistor of SOI pMOSFETs irradiated with Off-State bias, as well as that of the SOI n MOSFETs, increases as the channel length decreases. The annealing response of the back transistors after irradiation at room temperature without bias, as characterized by their threshold voltage shifts, indicates that there is a relatively complex annealing mechanism associated with channel length, type, and bias condition during irradiation. In particular, for all of the transistors irradiated with Off-State bias, their back transistors show an abnormal annealing effect during early annealing. All of these results have been discussed and analyzed in detail by the aid of simulation.  相似文献   

8.
The impact of ionizing radiation effect on single event upset(SEU) sensitivity of ferroelectric random access memory(FRAM) is studied in this work. The test specimens were firstly subjected to ~(60)Co γ-ray and then the SEU evaluation was conducted using ~(209)Bi ions. As a result of TID-induced fatigue-like and imprint-like phenomena of the ferroelectric material, the SEU cross sections of the post-irradiated devices shift substantially. Different trends of SEU cross section with elevated dose were also found, depending on whether the same or complementary test pattern was employed during the TID exposure and the SEU measurement.  相似文献   

9.
This paper studies the total ionizing dose radiation effects on MOS (metal-oxide-semiconductor) transistors with normal and enclosed gate layout in a standard commercial CMOS (compensate MOS) bulk process. The leakage current, threshold voltage shift, and transconductance of the devices were monitored before and after γ-ray irradiation. The parameters of the devices with different layout under different bias condition during irradiation at different total dose are investigated. The results show that the enclosed layout not only effectively eliminates the leakage but also improves the performance of threshold voltage and transconductance for NMOS (n-type channel MOS) transistors. The experimental results also indicate that analogue bias during irradiation is the worst case for enclosed gate NMOS. There is no evident different behaviour observed between normal PMOS (p-type channel MOS) transistors and enclosed gate PMOS transistors.  相似文献   

10.
陈世波  张力 《中国物理快报》2006,23(10):2881-2884
We re-study the one-dimensional electric field structure of an outer gap accelerator by considering the physical limit of trans-field height. Inside the outer gap, the charge depletion creates a large electric field along the magnetic field lines. Electrons and/or positrons are accelerated to ultra-relativistic energies by this longitudinal electric field, and then radiate γ-ray photons by curvature radiation. The collision of these γ-rays and ambient x-ray photons further produce radiating particles, resulting in a stationary gap. We solve the structure of this longitudinal electric field together with the distributions of electrons and positrons and γ-ray photons for an aligned rotator. Our results indicate that the outer gap can extend to the light cylinder using reasonable parameters.  相似文献   

11.
A multi-conjugate adaptive optics (MCAO) can offer a possibility of widening field of view (FOV) characterized by the isoplanatic angle, and the choose of conjugate height becomes a basic problem for MCAO, which influences the size of iosplanatic angle. Considering the application of lidar, the isoplanatic angle's expressions of two deformable mirrors (DMs) MCAO for uplink and downlink are deduced. The effects of conjugate heights for dual-conjugate AO are thoughtfully discussed, and the isoplanatic angles are further analyzed. The results show that the isopanatic angle varies with the conjugate height and reaches the maximum as the conjugate height is at the optimal altitude. Moreover, the optimal conjugate height changes with the propagation distance.  相似文献   

12.
Due to the limit of response speed of the present single-photon detector, the code rate is still too low to come into practical use for the present quantum key distribution (QKD) system.A new idea is put up to design a quick single-photon detector.This quick single-photon detector is composed of a multi-port optic-fiber splitter and many avalanche photo diodes (APDs).Au of the ports with APDs work on the time division and cooperate with a logic discriminating and deciding unit driven by the clock signal.The operation frequency lies on the number N of ports, and can reach N times of the conventional single-photon detector.The single-photon prompt detection can come true for high repetition-rate pulses.The applying of this detector will largely raise the code rate of the QKD, and boost the commercial use.  相似文献   

13.
14.
Characterization of PolyA and PolyC mismatches by Raman spectroscopy   总被引:1,自引:0,他引:1  
A.C mismatches are studied by Raman spectral characterization of PolyA, PolyC, and their equimolar complex in solution of 0.14 mol/L Na ,pH7.0.Experimental results show that A·C mismatches occur to be A/B (mainly A) conformers, and unlike Watson-Crick base pairing, this kind of mismatches is stabilized by only one hydrogen bond involving cytosine N4H2 and adenine N7.The formation of A·C complex makes the base stacking interactions much stronger, and conformation of the backbone more ordered, which leads to obvious Raman hypochromic effect with some shifts in corresponding bands.  相似文献   

15.
40-GHz clock modulated signal as a pump to improve the efficiency of four-wave mixing (FWM)-based wavelength conversion in a 26.5-km dispersion shifted fiber (DSF) is investigated. The experimental results demonstrate that the conjugated FWM component has higher intensity with the clock pumping than that with the continuous-wave (CW) light pumping. The improvement of FWM-based wavelength conversion efficiency is negligible when the pump power is less than Brillouin threshold. But when the pump power is greater than Brillouin threshold, the improvement becomes significant and increases with the increment of pump power. The improvement can increase up to 9 dB if pump power reaches 17 dBm.  相似文献   

16.
Microphone array-based speech enhancement has great importance for speech communications and speech recognition. To reduce the aperture of the microphone array and to increase the effect of the speech enhancement will greatly broaden the application areas of the microphone array. An array crosstalk resistant adaptive noise cancellation method is therefore presented. And then an improved spectral subtraction algorithm is further cascaded to obtain better enhancement results. Theoretic analysis and experiments indicate that the proposed scheme needs only a very small microphone array while it simultaneously achieves a higher SNR improvement. Besides, the proposed scheme can be used in many noisy environments and is easy for real-time implementation.  相似文献   

17.
Multi-pulse operation of a Kerr-lens mode-locked femtosecond laser   总被引:2,自引:0,他引:2  
Our experimental results show that the presence of a proper amount of negative group velocity dispersion is essential to multi-pulse operation of a Kerr-lens mode-locked femtosecond laser. We demonstrate that the pulse separations and the number of pulses contained within a cavity round trip are strongly dependent on the initial perturbations. The results allow us to get a better understanding on the influences of the convoluted self-phase modulation and intra-cavity dispersions on the stable multi-pulse oscillation in a Kerr-lens mode-locked femtosecond laser.  相似文献   

18.
Propagation of Helmholtz-Gauss beams in weak turbulent atmosphere   总被引:1,自引:0,他引:1  
Based on the Rytov approximation of light propagation in weak turbulent atmosphere,the closed-form expressions of field and average irradiance of each one of the four fundamental families of Helmholtz-Gauss (HzG)beams:cosine-Gauss beams,stationary Mathieu-Gauss beams,stationary parabolic-Gauss beams,and Bessel-Gauss beams,which are propagating in weak turbulent atmosphere,are obtained.The results show that the field and average irradiance can be written as the product of four factors:complex amplitude depending on the z-coordinate only,a Ganssian beam.a factor of complex phase perturbation induced by atmospheric turbulence,and a complex scaled version of the transverse shape of the non-diffracting beam.The effect of weak atmospheric turbulence on irradiance distribution of the HzG beam can be ignored.  相似文献   

19.
An effective method for reducing speckle noise in digital holography   总被引:1,自引:0,他引:1  
An effective method for reducing the speckle noise in digital holography is proposed in this paper.Different from the methods based on classical filtering technique,it utilizes the multiple holograms which are generated by rotating the illuminating light continuously.The intensity images reconstructed by a series of holograms generated by rotating the illuminating light possess different speckle patterns.Hence by properly averaging the reconstructed intensity fields,the speckle noises can be reduced greatly.Experimental results show that the proposed method is simple and effective to reduce speckle noise in digital holography.  相似文献   

20.
Influence of purity of HfO2 on reflectance of ultraviolet multilayer   总被引:1,自引:0,他引:1  
The impurities in two kinds of HfO2 materials and in their corresponding single layer thin films were determined through glow discharge mass spectrum technology and secondary ion mass spectrometry(SIMS) equipment respectively.It was found that ZrO2 was the main impurity in the two kinds of HfO2 either in the original HfO2 materials or in the electron beam deposited films.In addition,the difference of Zr content in the two kinds of HfO2 single laver films was much laxger than that of the other impurities such as Ti and Fe.which showed that it was just ZrO2 that made the difference between the optical performance of the film products including the two kinds of HfO2.With these two kinds of HfO2 and the same kind of SiO2.we deposited HfO2/SiO2 multilayer reflective coatings at the wavelength of 266 nm.Experimental results showed that the reflectances of these two mirrors were about 99.85% and 99.15% respectively,which agreed well with the designed results what were based on the optical constants obtained from the corresponding single layer thin films.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号