 共查询到10条相似文献,搜索用时 134 毫秒
1.
A frequency modulation (FM) method was developed to measure electron paramagnetic resonance (EPR) absorption. The first-derivative spectrum of 1,1-diphenyl-2-picrylhydrazyl (DPPH) powder was measured with this FM method. Frequency modulation of up to 1.6 MHz (peak-to-peak) was achieved at a microwave carrier frequency of 1.1 GHz. This corresponds to a magnetic field modulation of 57microT (peak-to-peak) at 40.3 mT. By using a tunable microwave resonator and automatic control systems, we achieved a practical continuous-wave (CW) EPR spectrometer that incorporates the FM method. In the present experiments, the EPR signal intensity was proportional to the magnitude of frequency modulation. The background signal at the modulation frequency (1 kHz) for EPR detection was also proportional to the magnitude of frequency modulation. An automatic matching control (AMC) system reduced the amplitude of noise in microwave detection and improved the baseline stability. Distortion of the spectral lineshape was seen when the spectrometer settings were not appropriate, e.g., with a lack of the open-loop gain in automatic tuning control (ATC). FM is an alternative to field modulation when the side-effect of field modulation is detrimental for EPR detection. The present spectroscopic technique based on the FM scheme is useful for measuring the first derivative with respect to the microwave frequency in investigations of electron-spin-related phenomena.  相似文献   

2.
Continuous-wave EPR spectroscopy using a frequency modulation (FM) scheme was developed. An electronically tunable resonator and an automatic tuning control (ATC) system were used. Using the FM scheme instead of magnetic field modulation, we detected EPR absorption at the first derivative mode. We used a microwave frequency of 1.1 GHz in the present experiment. Similar signal-to-noise ratios were obtained with conventional field modulation and the FM method, and a low-quality factor EPR resonator was not necessary to suppress the significant microwave reflection from the resonator. The FM method with a tunable resonator may be an alternative solution to achieving phase-sensitive detection, when the side-effects of magnetic field modulation, such as microphonic noise and mechanical vibration, are detrimental for EPR detection.  相似文献   

3.
This study describes the masking asymmetry between noise and iterated rippled noise (IRN) as a function of spectral region and the IRN delay. Masking asymmetry refers to the fact that noise masks IRN much more effectively than IRN masks noise, even when the stimuli occupy the same spectral region. Detection thresholds for IRN masked by noise and for noise masked by IRN were measured with an adaptive two-alternative, forced choice (2AFC) procedure with signal level as the adaptive parameter. Masker level was randomly varied within a 10-dB range in order to reduce the salience of loudness as a cue for detection. The stimuli were filtered into frequency bands, 2.2-kHz wide, with lower cutoff frequencies ranging from 0.8 to 6.4 kHz. IRN was generated with 16 iterations and with varying delays. The reciprocal of the delay was 16, 32, 64, or 128 Hz. When the reciprocal of the IRN delay was within the pitch range, i.e., above 30 Hz, there was a substantial masking asymmetry between IRN and noise for all filter cutoff frequencies; threshold for IRN masked by noise was about 10 dB larger than threshold for noise masked by IRN. For the 16-Hz IRN, the masking asymmetry decreased progressively with increasing filter cutoff frequency, from about 9 dB for the lowest cutoff frequency to less than 1 dB for the highest cutoff frequency. This suggests that masking asymmetry may be determined by different cues for delays within and below the pitch range. The fact that masking asymmetry exists for conditions that combine very long IRN delays with very high filter cutoff frequencies means that it is unlikely that models based on the excitation patterns of the stimuli would be successful in explaining the threshold data. A range of time-domain models of auditory processing that focus on the time intervals in phase-locked neural activity patterns is reviewed. Most of these models were successful in accounting for the basic masking asymmetry between IRN and noise for conditions within the pitch range, and one of the models produced an exceptionally good fit to the data.  相似文献   

4.
与传统光电成像系统成像质量的评价方法相比,最小可分辨对比度(MRC)能够更全面地反映光电成像系统的极限性能。它考虑了系统的灵敏度、噪声、目标空间频率以及人眼视觉特性等因素对系统阈值对比度的影响,可用于光电成像系统的视距估算。在分析微光ICCD成像系统工作原理的基础上,研制了新型微光ICCD成像系统MRC特性测试仪。以该系统为实验装置、以Weibull心理测量方程为理论基础设计了一种选择性靶标。基于选择性靶标,提出了一种基于强迫性选择MRC测量的新方法,利用该方法对微光ICCD成像系统进行了实际测量。该方法对建立微光ICCD成像系统MRC理论模型具有重要的指导意义,对直视型微光成像系统MRC特性的测量具有借鉴意义,对光电成像系统成像质量的评价具有重要的使用价值。  相似文献   

5.
Direct irradiation of a sample using a quartz oscillator operating at 250 MHz was performed for EPR measurements. Because a quartz oscillator is a frequency fixed oscillator, the operating frequency of an EPR resonator (loop-gap type) was tuned to that of the quartz oscillator by using a single-turn coil with a varactor diode attached (frequency shift coil). Because the frequency shift coil was mobile, the distance between the EPR resonator and the coil could be changed. Coarse control of the resonant frequency was achieved by changing this distance mechanically, while fine frequency control was implemented by changing the capacitance of the varactor electrically. In this condition, EPR measurements of a phantom (comprised of agar with a nitroxide radical and physiological saline solution) were made. To compare the presented method with a conventional method, the EPR measurements were also done by using a synthesizer at the same EPR frequency. In the conventional method, the noise level increased at high irradiation power. Because such an increase in the noise was not observed in the presented method, high sensitivity was obtained at high irradiation power.  相似文献   

6.
在自主研制的动态核极化(Dynamic Nuclear Polarization,DNP)分子影像装置的基础上,提出了一种集DNP和电子顺磁共振(Electron Paramagnetic Resonance,EPR)于一体的多功能谱仪,并对其中的关键部件之一——微波桥进行了设计.微波桥的引入,实现了DNP微波发射机的集成化,以及在DNP谱仪基础上的EPR功能扩展.通过结构设计、电路仿真及系统测试,完成了高频谱纯度、高动态范围的微波发射机以及低噪声系数的微波检测系统的设计与制作.并通过DNP增强实验以及连续波EPR实验对微波桥的性能进行了验证.  相似文献   

7.
For whole body EPR imaging of small animals, typically low frequencies of 250-750 MHz have been used due to the microwave losses at higher frequencies and the challenges in designing suitable resonators to accommodate these large lossy samples. However, low microwave frequency limits the obtainable sensitivity. L-band frequencies can provide higher sensitivity, and have been commonly used for localized in vivo EPR spectroscopy. Therefore, it would be highly desirable to develop an L-band microwave resonator suitable for in vivo whole body EPR imaging of small animals such as living mice. A 1.2 GHz 16-gap resonator with inner diameter of 42 mm and 48 mm length was designed and constructed for whole body EPR imaging of small animals. The resonator has good field homogeneity and stability to animal-induced motional noise. Resonator stability was achieved with electrical and mechanical design utilizing a fixed position double coupling loop of novel geometry, thus minimizing the number of moving parts. Using this resonator, high quality EPR images of lossy phantoms and living mice were obtained. This design provides good sensitivity, ease of sample access, excellent stability and uniform B(1) field homogeneity for in vivo whole body EPR imaging of mice at 1.2 GHz.  相似文献   

8.
Regions in the cochlea with very few functioning inner hair cells and/or neurons are called "dead regions" (DRs). Previously, we measured the recognition of highpass-filtered nonsense syllables as a function of filter cutoff frequency for hearing-impaired people with and without low-frequency (apical) DRs [J. Acoust. Soc. Am. 122, 542-553 (2007)]. DRs were diagnosed using the TEN(HL) test, and psychophysical tuning curves were used to define the edge frequency (fe) more precisely. Stimuli were amplified differently for each ear, using the "Cambridge formula." The present study was similar, but the speech was presented in speech-shaped noise at a signal-to-noise ratio of 3 dB. For subjects with low-frequency hearing loss but without DRs, scores were high (65-80%) for low cutoff frequencies and worsened with increasing cutoff frequency above about 430 Hz. For subjects with low-frequency DRs, performance was poor (20-40%) for the lowest cutoff frequency, improved with increasing cutoff frequency up to about 0.56fe, and then worsened. As for speech in quiet, these results indicate that people with low-frequency DRs are able to make effective use of frequency components that fall in the range 0.56fe to fe, but that frequency components below 0.56fe have deleterious effects.  相似文献   

9.
Kou SS  Sheppard CJ 《Optics letters》2008,33(20):2362-2364
Tomography has been applied to holographic imaging systems recently to improve the 3D imaging performance. However, there are two distinct ways to achieve this: either by rotation of the object or by rotation of the illumination beam. We provide a transfer function analysis to distinguish between these two techniques and to predict the 3D imaging performance in holographic tomography when diffraction effects are considered. The results show that the configuration of rotating the illumination beam in one direction while fixing the sample leads to different 3D imaging performance as compared to the configuration of rotating the sample. The spatial frequency cutoff is nonisotropic in the case of rotating the illumination, and a curved line of singularity is observed. Rotating of the sample, on the contrary, has more symmetry in spatial frequency coverage but has a single point of singularity. The 3D transfer function derived can be used for 3D image reconstruction.  相似文献   

10.
Functional magnetic resonance imaging (fMRI) technique with blood oxygenation level dependent (BOLD) contrast is a powerful tool for noninvasive mapping of brain function under task and resting states. The removal of cardiac- and respiration-induced physiological noise in fMRI data has been a significant challenge as fMRI studies seek to achieve higher spatial resolutions and characterize more subtle neuronal changes. The low temporal sampling rate of most multi-slice fMRI experiments often causes aliasing of physiological noise into the frequency range of BOLD activation signal. In addition, changes of heartbeat and respiration patterns also generate physiological fluctuations that have similar frequencies with BOLD activation. Most existing physiological noise-removal methods either place restrictive limitations on image acquisition or utilize filtering or regression based post-processing algorithms, which cannot distinguish the frequency-overlapping BOLD activation and the physiological noise. In this work, we address the challenge of physiological noise removal via the kernel machine technique, where a nonlinear kernel machine technique, kernel principal component analysis, is used with a specifically identified kernel function to differentiate BOLD signal from the physiological noise of the frequency. The proposed method was evaluated in human fMRI data acquired from multiple task-related and resting state fMRI experiments. A comparison study was also performed with an existing adaptive filtering method. The results indicate that the proposed method can effectively identify and reduce the physiological noise in fMRI data. The comparison study shows that the proposed method can provide comparable or better noise removal performance than the adaptive filtering approach.  相似文献   