 共查询到17条相似文献,搜索用时 93 毫秒
1.
TN366 2004064375 近红外高精度光辐射标准探测器的实验研究=Highly accurate calibration of optical radiation detectors at near infrared spectrum[刊,中]/李双(中科院安徽光机所遥感研究室.安徽,合肥(230031)),吴浩宇…∥光学技术.—2004,30(4).—498-501 在594nm和785nm两个波长上,用以低温辐射计标定过的陷阱探测器作为基准,对两个响应未知的陷阱探测器进行了绝对标准的传递。为此建立了一种辐射定标的新型测量光路,估算和分析了在光路调整时影响测量精度的关键环节,其中包括光功率传输效率以及光路色散效应的影响。分析了在传递过程中各主要环节的不  相似文献   

2.
介绍了溯源至低温辐射计的紫外绝对光谱响应度测量装置,对硅陷阱探测器在三个激光波长点进行了绝对光谱响应度校准实验.测量了硅陷阱探测器的空间均匀性和非线性系数,分析了影响测量准确度的各不确定度分量.实验表明:硅陷阱探测器在紫外波段266、325、379 nm三个激光波长点处的绝对光谱响应度测量扩展不确定度分别为0.19%、0.14%、0.11%,可作为紫外波段光辐射功率基准保持和传递的标准探测器,用于提高紫外波段光谱辐射度的校准能力.  相似文献   

3.
介绍了溯源至低温辐射计的紫外绝对光谱响应度测量装置,对硅陷阱探测器在三个激光波长点进行了绝对光谱响应度校准实验.测量了硅陷阱探测器的空间均匀性和非线性系数,分析了影响测量准确度的各不确定度分量.实验表明:硅陷阱探测器在紫外波段266、325、379nm三个激光波长点处的绝对光谱响应度测量扩展不确定度分别为0.19%、0.14%、0.11%,可作为紫外波段光辐射功率基准保持和传递的标准探测器,用于提高紫外波段光谱辐射度的校准能力.  相似文献   

4.
通过研制真空多光路切换组件,结合Y型真空比较通道、探测器真空舱,在保证超高真空环境的前提下,实现激光、紫外连续可调单色光以及真空紫外单色光3个光路的快速切换,从而以低温辐射计为基准,以紫外增强硅陷阱探测器为传递标准,实现波长115 nm~400 nm紫外探测器绝对光谱响应度的测量,实验验证绝对光谱响应度测量不确定度在115 nm~230 nm可达到0.8%~1.5%(k=2),在230 nm~400 nm可达到0.5%~1.0%(k=2)。  相似文献   

5.
报道了可见-近红外波段(488~944nm)基于低温辐射计的光谱辐射功率定标和标准传递实验和研究,并对测量结果的各个不确定因素进行了测量和分析。首先低温辐射计采用电替代方法测量单个波长激光绝对光功率,测量不确定度低于0.016%。然后利用低温辐射计定标作为标准传递探测器的硅陷阱探测器,从而建立可见-近红外波段陷阱探测器的绝对光谱响应率标准,其不确定度小于0.028%。结果证明了在此波段以探测器为基础建立和传递高精度光辐射标准的合理性和可行性。  相似文献   

6.
李健军  郑小兵  卢云君  张伟  谢萍  邹鹏 《物理学报》2009,58(9):6273-6278
介绍了利用钛宝石可调谐激光器、倍频器和单波长激光器作为光源,在24个波长分立点定标了三个硅陷阱探测器的绝对光谱响应度,解决了红外激光的精确定位与调整、窗口透过率模拟定标等关键技术.结果显示:在激光波长为412—800nm时,三个陷阱探测器定标的不确定度约低于0.05%;当激光波长大于800nm以及低于355nm时,获得的陷阱探测器的定标不确定度约低于0.065%.硅陷阱探测器可以作为空间各类遥感器在350—1064nm波段定标的传递标准探测器. 关键词: 陷阱探测器 低温辐射计 光谱响应度 辐射定标  相似文献   

7.
介绍了1.3 μm/1.5 μm光纤激光功率溯源至低温辐射计的测量方法,与传统溯源至绝对辐射计的方法相比较,最终利用低温辐射计法通过633 nm波长稳定光源标定陷阱式探测器,然后用陷阱式探测器将量值传递到陷阱式量传探测器,最后通过1310 nm/1550 nm通信用光功率稳定光源通过热释电光功率计标定InGaAs光电探测器并用于测量光纤功率。实验结果表明,溯源至低温辐射计的光纤功率测量方法在1310 nm及1550 nm波长点处对一标准光功率计修正系数测量的相对标准差分别为0.0011及0.0007,其测量不确定度可优于0.6%(k=2),在保证量值一致性的同时有效降低了测量不确定度,提高量值传递精度。  相似文献   

8.
探测器的光谱辐射照(亮)度响应度是辐射定标中最重要的参数之一。传统的光谱辐射定标采用宽谱段光源和单色仪装置测量,新建的激光辐射测量装置采用激光和探测器测量,可以大大降低测量的不确定度。该装置首先将可调谐激光耦合进入积分球生成均匀的朗伯体单色光源,然后采用低温辐射计量传的标准陷阱探测器和面积已知的光阑,进行400~900 nm探测器的光谱辐射照度响应度标定。研究主要集中在四个方面:(1) 低温辐射计仅在某些分立激光波长定标标准探测器,其他激光波长下的光谱响应度必须进行插值,通过对比光谱响应度直接测量方法推导的陷阱探测器量子吸收效率,可以计算插值在其他波长带来的光谱响应度偏差,结果表明400~900 nm数据插值算法的总体偏差小于0.074%;(2) 实验采用电荷积分法测量标准探测器和被测探测器的电荷信号,并采用监视探测器消除激光功率起伏以降低激光功率稳定性的影响,测量重复性优于0.1%;(3) 针对标准探测器在向低温辐射计溯源和进行光谱辐射照度响应度量传时的激光功率差异,采用激光双光路叠加法测量探测器不同波长下的非线性系数,分析标准探测器光谱非线性带来的测量不确定度,在450,632.8和850 nm波长下,当探测器电流从0.2 mA变到3 nA时的非线性修正小于1.000 25;(4) 针对标准探测器定标时的功率模式和量传时的辐射照度模式差异,采用二维电控位移平台测量探测器的均匀性并进行修正,测量得到的标准探测器中心直径5 mm的非均匀性小于0.03%。最终采用可调谐激光辐射照度响应度测量装置,可以实现400~900 nm辐射照度响应度测量不确定度0.14%~0.074%(k=1)。实验对比了激光辐照度响应度装置和标准灯-单色仪装置两种方法测量的探测器的光谱辐射照度响应度。测量结果表明两种装置在400~900 nm的响应度标定近似等价,测量偏差全部位于标准灯-单色仪装置的测量不确定度范围内, 验证了激光辐照度响应度测量装置的实用性。  相似文献   

9.
高精度光电探测器的线性测量   总被引:3,自引:1,他引:2  
陈风  李双  王骥  郑小兵 《光学学报》2008,28(5):889-893
介绍了一种高精度的光电探测器线性测量系统,讨论了线性测量的方法,确定以光束叠加法为线性测量系统的基础.设计了测量系统,以944 nm激光器为光源,测量了Si陷阱探测器和InGaAs陷阱探测器的非线性因子.实验结果表明,利用该系统在0.1~200μW的入射光功率范围内.Si陷阱探测器非线性因子平均值小于0.009%,联合不确定度小于3.18%;InGaAs陷阱探测器非线性因子平均值小于0.6%,联合不确定度小于6.87%.实验结果证明该系统可以作为高精度光电探测器线性测量装置.  相似文献   

10.
基于低温辐射计的InGaAs陷阱探测器高精度光辐射定标研究   总被引:2,自引:0,他引:2  
介绍了以InGaAs陷阱探测器作为传递探测器,基于低温辐射计的高精度光辐射定标和标准传递实验与研究。在红外(944-1589nm)三个波长初步给出了InGaAs陷阱探测器绝对光谱响应率定标结果。InGaAs陷阱探测器绝对光谱响应率的联合不确定最大为0.655%,最小为0.026%。  相似文献   

11.
对研制的安装在合肥国家同步辐射实验室(NSRL)计量光束线上的VUV/EUV标准探测器装置进行了传输标准探测器的首次标定工作.实验选取了3个能点17.625nm,6.8nm和92nm,在这3个能点处分别标定光电二极管,得到其相应的量子效率.结果表明在同一能点多次标定结果的重复一致性很好,相对标准偏差在1%—14%的水平;但是与美国国家标准计量局(NIST)标定过的光电二极管的量子效率比较,短波17.625nm的标定结果较好,而6.8nm和92nm波长的结果差距偏大.偏差主要来自光源稳定性和光谱纯净度的影响.  相似文献   

12.
The method of pulsed cavity-ring-down spectroscopy was employed to record the water vapor absorption spectrum in the wavelength range 555-604 nm. The spectrum consists of 1830 lines, calibrated against the iodine standard with an accuracy of 0.01 cm(-1); 800 of these lines are not obtained in the HITRAN 96 database, while 243 are not included in the newly recorded Fourier transform spectrum of the Reims group. Of the set of hitherto unobserved lines, 111 could be given an assignment in terms of rovibrational quantum numbers from a comparison with first principles calculations. Copyright 2001 Academic Press.  相似文献   

13.
Optically stimulated luminescence (OSL) signals from feldspar and quartz samples were studied using infrared (860 nm) and green light (420–575 nm) stimulation. A serious problem connected with the regeneration technique used for dating is associated with a change of OSL sensitivity to radiation in the course of the measurement process. A typical effect seen is a large increase of the apparent strength of our beta source when calibrated against a gamma source. If the regeneration procedure is used, it is shown that the sensitivity increases up to 50% during the measurement process and as a result, the equivalent dose (ED) would be underestimated. A study of sensitivity changes in feldspars and quartz was carried out with emphasis on the effect of preheat and annealing on the OSL signal. Measurement results obtained are presented, and possible elimination of errors in dating caused by sensitivity changes is discussed.  相似文献   

14.
硅陷阱探测器绝对光谱响应率校准实验研究   总被引:1,自引:0,他引:1  
以Ar^+Kr^+激光器、He—Ne激光器和半导体泵浦激光器作为光源,利用激光稳功率装置以及闭环机械制冷型低温辐射计,校准了硅陷阱探测器的绝对光谱响应率。在硅探测器的光谱响应范围400-1100nm内,选择476.1nm、488nm、514.7nm、521nm、568nm、632.8nm、647.1nm、1064nm共8条谱线进行了实验研究。实验数据表明,绝对光谱响应率的测量不确定度为可见光波段优于0.02%,1064nm波长点优于0.03%。  相似文献   

15.
光谱辐射定标是光学遥感仪器研制中的关键环节。深入分析实验室定标的光谱辐射测量仪器至户外应用的不确定度来源,环境温度是限制仪器户外高精度测量的最主要因素之一。传统的光谱辐射度实验室定标通常在室温(~25 ℃)下进行,而户外光谱辐射测量处于不同温度环境,严重影响仪器测量的准确度。设计搭建实验测量系统,采用遥感辐射领域常用的光谱辐射测量仪器,研究环境温度对光谱辐射测量的影响。实验结果显示:常用光谱辐射计(CR-280)的测量结果受温度影响明显,在10~40 ℃之间变化时,仪器光谱辐射亮度测量值在400~700nm波段内的偏差为±5%左右,而700~1 050 nm内的偏差高达±15%左右。这主要由于仪器采用硅探测器,红外波段恰好与硅的带边接近,硅探测器易受温度影响,温度增加硅的带边会向长波方向移动,光谱辐射计的响应度也随之增加。基于实验数据统计分析,提出一种适用于不同类型光谱辐射计的温度修正方法,相对于传统的斜率/截距(S/B)算法适用性更广,还可由公式计算出任意温度下的修正结果。修正后CR-280红外波段的偏差(950 nm左右)由±10%降低为±1%,明显减小了因户外使用与实验室定标温度不同造成的测量结果偏差。此外,利用不同类型光谱辐射测量仪器(Avantes及SVC HR-1024)对温度修正方法进行验证。环境温度变化时光谱仪Avantes(VIS/NIR)的测量结果存在较大偏差(1 060 nm高达±17%)。通过温度修正方法运算,仪器修正值与定标值的偏差在±1%以内。光谱辐射计(SVC HR-1024)不同波段的测量值,与定标值的偏差受温度影响不同。这主要由于:仪器由Si、制冷型InGaAs及扩展InGaAs探测器组成,Si探测器受温度影响大,950~1 000 nm波段测量值与定标值的偏差高达±10%。而制冷型InGaAs可有效控制探测器温度,受温度的直接影响相对小。但随温度增加,InGaAs探测器制冷效果受限(制冷最佳工作温度为20 ℃),测量结果产生偏差(1%~3%)。同样,利用温度修正公式对不同温度下SVC HR-1024的测量结果进行修正运算,仪器因温度变化引起的偏差可降低至±1%以内。  相似文献   

16.
In UME, the relative spectral responsivity scale extending from 250 to 2500 nm was realized using electrically calibrated pyroelectric radiometer (ECPR). Its absolute spectral responsivity was determined against the electrical substitution cryogenic radiometer (ESCR) facility at 488.1, 514.6, 532.0, and 632.8 nm with an uncertainty of 1 part in 104 (k=2). The relative spectral responsivity scale of ECPR was derived from the surface reflectance data and absolute spectral responsivity data for the mentioned spectral range. Optical characterization of its spatial non-uniformity (at 632.8 nm) and surface reflectance (over 250–2500 nm wavelength region) indicated that the gold-black absorber is spectrally flat within 0.1%. The total expanded uncertainty in the realization of the mentioned radiometric scale along with ECPR was estimated as 1.74%.  相似文献   

17.
A novel type of system based on a frequency-quadrupled Nd:YAG laser light source at 266 nm and a dual-cell photoacoustic detection unit was developed, and its applicability for ozone-concentration measurement with a minimum detectable ozone concentration of about 100 pptV was demonstrated. The instrument was calibrated against an ozone generator, and it was installed at a regional environmental monitoring station to be operated in parallel with a commercial UV-absorption photometry based ozone-monitoring instrument. While good agreement between the readings of the two systems was found, the photoacoustic system outperformed its optical absorption based counterpart as far as minimum detectable concentration and measurement accuracy is concerned.  相似文献   