1.
In this study, a three-dimensional finite-element model (FEM) of the human middle ear was established, including features of the middle ear which were not considered in the previous model, i.e., the ligaments, tendons, I-S joint, loading of the cochlea, external auditory meatus (EAM), middle-ear cavities, etc. The unknown mechanical properties of these parts and the boundary conditions were determined so that the impedance obtained from the FEM analysis resembled the measurement values. The validity of this model was confirmed by comparing the motion of the tympanic membrane and ossicles obtained by this model with the measurement data, and the effects of the newly considered features on the numerically obtained results were examined. By taking the ligaments and tendons into account and assuming that the cochlea acts as a damper, with this model it was possible to realistically reproduce complex ossicular chain movement. It was found that the middle-ear cavities did not affect the vibration mode of the tympanic membrane. Although the EAM enhanced the sound pressure applied to the tympanic membrane compared with that at the entrance of the EAM, the pressure distribution on the surface of the tympanic membrane was not affected by the EAM.  相似文献   

2.
An attempt is made to develop a new measuring apparatus, and the dynamical characteristics of the middle ear of normal subjects and patients are measured with this apparatus. Applying the impedance theory of the tube to the external auditory canal, the aditus, and the tympanic and mastoid cavities, and applying the energy method to the eardrum and the ossicular chain, the equation of the middle ear, corresponding to the output of the apparatus and including the pressure difference effect upon the eardrum, is obtained. The numerical results are compared with the measurement results, and the effects of each part of the middle ear upon its dynamical characteristics are clarified. The great dependence of the dynamical characteristics of the middle ear upon the external auditory canal pressure is mainly caused by the pressure-dependent ossicular chain angular stiffness. The clearly different measurement results of the ossicular chain disorder patients from those of the normal subjects are obtainable by this apparatus, and these characteristics can be explained theoretically.  相似文献   

3.
In order to better understand signal propagation in the ear, a time-domain model of the tympanic membrane (TM) and of the ossicular chain (OC) is derived for the cat. Ossicles are represented by a two-port network and the TM is discretized into a series of transmission lines, each one characterized by its own delay and reflection coefficient. Volume velocity samples are distributed along the ear canal, the eardrum, and the middle ear, and are updated periodically to simulate wave propagation. The interest of the study resides in its time-domain implementation--while most previous related works remain in the frequency domain--which provides not only a direct observation of the propagating wave at each location, but also insight about how the wave behaves at the ear canal/TM interface. The model is designed to match a typical impedance behavior and is compared to previously published measurements of the middle ear (the canal, the TM, the ossicles and the annular ligament). The model matches the experimental data up to 15 kHz.  相似文献   

4.
5.
The function of the middle ear is to transfer acoustic energy from the ear canal to the cochlea. An essential component of this system is the tympanic membrane. In this paper, a new finite element model of the middle ear of the domestic cat is presented, generated in part from cadaver anatomy via microcomputed tomographic imaging. This model includes a layered composite model of the eardrum, fully coupled with the acoustics in the ear canal and middle-ear cavities. Obtaining the frequency response from 100 Hz to 20 kHz is a computationally challenging task, which has been accomplished by using a new adaptive implementation of the reduced-order matrix Padé-via-Lanczos algorithm. The results are compared to established physiological data. The fully coupled model is applied to study the role of the collagen fiber sublayers of the eardrum and to investigate the relationship between the structure of the middle-ear cavities and its function. Three applications of this model are presented, demonstrating the shift in the middle-ear resonance due to the presence of the septum that divides the middle-ear cavity space, the significance of the radial fiber layer on high frequency transmission, and the importance of the transverse shear modulus in the eardrum microstructure.  相似文献   

6.
Behavioral studies of hearing loss produced by exposure to ototraumatic agents in experimental animals, combined with the anatomical evaluation of end-organ pathology, have provided useful information about the relation between dysfunction and pathology. However, in order to attribute a given hearing loss to some pattern of cochlear damage, it is necessary to test each ear independently. The objective of the present study was to evaluate attenuation measured behaviorally and protection to the cochlea provided by removal of the malleus and incus in noise-exposed chinchillas. Results from one behaviorally trained chinchilla with ossicular removal indicated a conductive hearing loss that varied from 41 dB at 0.125 kHz to 81 dB at 4.8 kHz and averaged 60 dB. Counts of missing sensory cells in ears of seven chinchillas with unilateral ossicular removal and exposure to noise (octave band centered at 0.5 kHz, 95 dB SPL, for durations up to 216 days, or centered at 4.0 kHz, 108 dB SPL, for 1.75 h) showed no more cell loss on the protected side than in age-matched control ears. From these data it is concluded that ossicular removal provides enough attenuation to protect the chinchilla cochlea from damage during these noise exposures, and that it will insure monaural responses behaviorally as long as the hearing loss in the test ear does not exceed that in the ear with ossicular removal by approximately 50 dB at any frequency.  相似文献   

7.
Audiograms in air and underwater, determined by previous workers for four pinniped species, two eared seals (Otariidae) and two phocids (Phocidae), are supplemented here by measurements on their middle ear ossicular mass, enabling mechanistic interpretations of high-frequency hearing and audiogram differences. Otariid hearing is not largely affected by the medium (air/water). This indicates that cochlear constraints limit high-frequency hearing in otariids. Phocids, however, have massive middle ear ossicles, and underwater hearing has radically shifted towards higher frequencies. This suggests that the high-frequency hearing of phocids in air is constrained by ossicle inertia.  相似文献   

8.
The effect of standing waves on the ear canal measurement of eardrum sound pressure level (SPL) was determined by both calculation and measurement. Transmission line calculations of the standing wave were made using the dimensions of the ANSI S3.25-1979 ear simulator and three different eardrum impedances. Standing wave curves have been obtained for the standard eardrum impedance at 1-kHz intervals in the range of 1-8 kHz. The changes in standing wave position due to each of the three eardrum impedances and their effects on ear canal measurements of SPL were computed for each of the eardrum impedances. Ear canal SPL measurements conducted on simulators modified to correspond to the eardrum impedances used in the calculations were compared to the computed values. Differences between eardrum SPLs and those measured at different locations in the ear canal approached a standing wave ratio (SWR) of 10-12 dB as the position of the measuring probe approached the standing wave minimum at each frequency. These maximum differences compared favorably with data developed by other investigators from real ears. Differences due to the eardrum impedance were found to be significant only in the frequency region of 2-5 kHz. Calibration of probes in a standard or modified ANSI simulator at the same distance from the eardrum as in the real ear reduces the eardrum SPL measurement errors to those resulting from differences in eardrum impedance.  相似文献   

9.
Wave propagation modeling as a vital tool in seismology can be done via several different numerical methods among them are finite-difference, finite-element, and spectral-element methods (FDM, FEM and SEM). Some advanced applications in seismic exploration benefit the frequency domain modeling. Regarding flexibility in complex geological models and dealing with the free surface boundary condition, we studied the frequency domain acoustic wave equation using FEM and SEM. The results demonstrated that the frequency domain FEM and SEM have a good accuracy and numerical efficiency with the second order interpolation polynomials. Furthermore, we developed the second order Clayton and Engquist absorbing boundary condition (CE-ABC2) and compared it with the perfectly matched layer (PML) for the frequency domain FEM and SEM. In spite of PML method, CE-ABC2 does not add any additional computational cost to the modeling except assembling boundary matrices. As a result, considering CE-ABC2 is more efficient than PML for the frequency domain acoustic wave propagation modeling especially when computational cost is high and high-level absorbing performance is unnecessary.  相似文献   

10.
This article presents frequency responses calculated using a three-dimensional finite-element model of the cat eardrum that includes damping. The damping is represented by both mass-proportional and stiffness-proportional terms. With light damping, the frequency responses of points on the eardrum away from the manubrium display numerous narrow minima and maxima, the frequencies and amplitudes of which are different for different positions on the eardrum. The frequency response on the manubrium is smoother than that on the eardrum away from the manubrium. Increasing the degree of damping smooths the frequency responses both on the manubrium and on the eardrum away from the manubrium. The overall displacement magnitudes are not significantly reduced even when the damping is heavy enough to smooth out all but the largest variations. Experimentally observed frequency responses of the cat eardrum are presented for comparison with the model results.  相似文献   