首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 156 毫秒
1.

Purpose

The purpose was to describe magnetic resonance imaging (MRI) findings of breast cancer liver metastasis using gadoxetic acid (Gd-EOB-DTPA) with an emphasis on the added value of the hepatobiliary phase (HBP).

Material and methods

Nine patients with 13 liver metastases were included in the study after the medical records of 29 breast cancer patients who underwent Gd-EOB-DTPA-enhanced MRI between February 2008 and June 2010 were reviewed. The diagnoses of liver metastasis were established by percutaneous liver biopsy or surgery and on the basis of image findings. Two radiologists retrospectively evaluated signal intensity (SI) and sizes of metastases and patterns of enhancement in an HBP. The SI ratio was calculated as the SI of the central hyperintense portion in “target” lesions divided by the SI of nearby normal liver parenchyma on the HBP. We also measured apparent diffusion coefficient (ADC) values from Diffusion Weighted Image (DWI).

Results

Liver metastases were all hypointense [n=13/13 (100%)] on T1-weighted imaging (WI), and many lesions had a “target” appearance with a central high SI and a peripheral low SI rim (47%) on T2WI. Dynamic study showed rim enhancement on the arterial phase (85%) and a “target” appearance, consisting of a central enhancing portion with peripheral washout or hypointense rim, on the HBP (62%). The mean SI ratio was 0.7. The mean ADC value of “target” appearing metastases was 1.25 (×10−3 mm2/s; range 1.3–1.6) compared with a mean value of 0.8 (×10−3 mm2/s; range 0.8–1.4) in homogeneous defect on the HBP. There was statistically significant difference (P<.05).

Conclusion

Breast cancer liver metastases commonly demonstrated as a peripheral ring enhancement on arterial dominant phase and a target sign with a central round enhancing portion and a peripheral hypointense rim on the HBP.  相似文献   

2.
3.

Objective

Chemotherapy commonly causes liver injury through sinusoidal obstructive syndrome and steatosis. Chemotherapy-induced liver injury may make it more difficult to detect metastases secondary to reduced contrast between the injured liver and metastases. The aim of this study was to determine the sensitivity of superparamagnetic iron oxide (SPIO) contrast-enhanced imaging in patients who have undergone chemotherapy prior to liver surgery.

Methods

Local ethics committee approval was obtained. Thirty-one patients with hepatic metastases completing preoperative chemotherapy were prospectively recruited. Images were reviewed independently by two blinded observers who identified and localized lesions with a four-point confidence scale. The alternative free-response receiver operator characteristic method was used to analyze the results.

Results

The sensitivity in detecting colorectal metastases following chemotherapy was 78% and 76%, respectively, for observers 1 and 2 (95% confidence interval: 71%–85% and 68%–82%). The areas under the alternative free-response receiver operator curves were 0.73 and 0.80 for observers 1 and 2, respectively.

Conclusion

Compared to previously published work on chemotherapy-naïve patients, it is clear that the sensitivity of SPIO-enhanced magnetic resonance imaging (MRI) in detecting colorectal metastases following chemotherapy is reduced. It is therefore critical that all imaging — pre-, during and postchemotherapy — is reviewed when reporting liver MRI prior to surgery.  相似文献   

4.

Objective

Magnetic resonance imaging (MRI) offers great potential as a sensitive and noninvasive technique for describing the alterations in mechanical properties, as shown in vitro on intervertebral disc (IVD) or cartilage tissues. However, in vivo, the IVD is submitted to complex loading stimuli. Thus, the present question focuses on the influence of the mechanical loading during an MRI acquisition on the relaxation times, magnetization transfer and diffusion parameters within the IVD.

Methods

An apparatus allowing the compression of isolated IVDs was designed and manufactured in acrylonitrile butadiene styrene. IVDs were dissected from fresh young bovine tail, measured for their thickness and submitted to compression just before the MRI acquisition. Six discs received 0% (platen positioned at the initial disc thickness), 5% (platen positioned at 95% of the initial disc thickness), 10%, 20% and 40% deformation. The MRI parameters were compared between the loading states using mean and standard deviation for T1 and T2, and matrix subtraction for Magnetization Transfer, fractional anisotropy and apparent diffusion coefficient.

Results

The compression of the IVD did not lead to any significant change of the MRI parameters, except for the diffusion that decreased in the direction of the compressive stress.

Discussion

This experimental in vitro study shows that multi-parametric MRI on isolated discs in vitro is not sensitive to compression or to the partial confined relaxation that followed the compression.  相似文献   

5.

Objective

The objective was to evaluate magnetic resonance imaging (MRI) issues (magnetic field interactions, heating, artifacts and functional alterations) at 1.5 T and 3 T for the Argus II Retinal Prosthesis (Second Sight Medical Products, Sylmar, CA, USA).

Materials and Methods

Standardized protocols were used to assess magnetic field interactions (translational attraction and torque; 3 T, worst case), MRI-related heating (1.5 and 3 T), artifacts (3 T; worst case) and functional changes (1.5 and 3 T) associated with MRI.

Results

The magnetic field interactions were acceptable. MRI-related heating, which was studied at a relatively high, MR system-reported whole body averaged specific absorption rates, will not pose a hazard to the patient under the conditions used for testing. While artifacts were “moderate” in relation to the dimensions of the Argus II Retinal Prosthesis, optimization of MRI parameters can reduce the size of the artifacts. Exposures to MRI conditions at 1.5 and 3 T did not damage or alter the functional aspects of the Argus II Retinal Prosthesis.

Conclusions

In consideration of the test results, a patient with the Argus II Retinal Prosthesis may undergo MRI at 1.5 T or 3 T when specific guidelines and MRI conditions are followed, including those advised by the manufacturer.  相似文献   

6.

Objective

To evaluate the image findings of focal fat deposition (FFD) in the liver on gadobenate dimeglumine (Gd-BOPTA)- and gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI, particularly during the hepatobiliary phase (HBP), and the relationship between relative enhancement (RE) and fat signal fraction (FSF) of FFD.

Subjects and Methods

Twenty-one patients with 27 FFDs (mean diameter, 21.9 mm), which showed low signal intensity on opposed-phase compared with in-phase MRI, were retrospectively evaluated. RE of the liver (REliver) and FFD (REFFD) and liver-to-lesion contrast-to-noise ratio (CNR) of FFD were measured on dynamic phases and HBP images with fat-saturated in-phase gradient-echo sequence. The FSF of each FFD was measured on in- and opposed-phase dual gradient-echo images. We qualitatively analyzed imaging findings of FFDs, including signal intensity, shape, margin, and homogeneity on HBP images, and enhancement pattern during dynamic phases. The correlations between REFFD and FSF and between CNR and FSF on HBP images were evaluated using Pearson’s correlation tests and a simple linear regression model.

Results

There were no significant differences between REFFD and REliver in dynamic phases and HBP, regardless of contrast agents (p ≥ 0.075). On HBP images, CNR (p = 0.008) but not REFFD (p = 0.122) was significantly correlated with FSF of FFDs (mean FSF, 19%). On HBP images, 21 of the 27 (77.8%) FFDs were hypointense, and 17 (63%) were homogeneous. Of the 21 hypointense FFDs, 12 (57.1%) had an ovoid shape and 11 (52.4%) were well margined. Although the 27 FFDs showed various enhancement patterns, 17 (63%) showed no enhancement.

Conclusion

Most FFDs appeared as hypointense lesions on Gd-BOPTA- and Gd-EOB-DTPA-enhanced MRI during HBP, with various enhancement patterns during dynamic contrast-enhanced phases. REFFD on HBP images was not significantly correlated with FSF of low grade FFDs.  相似文献   

7.

Objective

To demonstrate the additional utility of ultrafast magnetic resonance imaging (MRI) of the fetus in the evaluation of sonographically detected or equivocal fetal congenital anomalies.

Material and Methods

Twenty five pregnant women with ultrasound detected fetal congenital anomalies underwent ultrafast fetal MRI.

Results

MRI findings altered the diagnosis of two cases of giant arachnoid cyst and sizable interhemispheric cyst associated with agenesis of the corpus callosum. MRI added additional findings of occult spinal diastematomyelia in two out of four cases of Chiari/meningocele malformation. MRI revealed impaired sulcation and unilateral cleft palate in suspected case of Walker-Warburg syndrome. In the remaining 18 cases MRI confirmed the diagnosis of Meckel–Gruber syndrome in three cases, hydronephrosis in six cases, cerebral ventriculomegaly in five cases, isolated omphalocele in three cases and findings suggestive of aneuploidy in the last case.

Conclusion

Ultrasound is the screening method of choice for evaluation of the fetus. Ultrafast MRI is a complementary adjunctive modality with excellent tissue contrast that can image the fetus in multiple planes and add information in sonographically detected or equivocal congenital anomalies that may be significant to establish definitive accurate diagnosis and hence adequate management and counseling.  相似文献   

8.

Background and Purpose

A recent report suggested that a serious burn injury was due to the presence of the identification (ID) wristband. As such, in lieu of removing or padding hospital ID wristbands in all patients prior to magnetic resonance imaging (MRI), testing may be performed to characterize risks for ID wristbands. Therefore, the purpose of this investigation was to evaluate the magnetic field interactions, heating and artifacts at 3 T for a hospital ID wristband.

Materials and Methods

Standardized test methods were used to evaluate magnetic field interactions, MRI-related heating, and artifacts at 3 T for a hospital ID wristband.

Results

There were no magnetic field interactions. MRI-related heating evaluated at a relatively high, MR system-reported, whole body-averaged specific absorption rate (2.9 W/kg) did not increase above the background level. The artifacts related to the ink used for printing were “small” for one toner and “large” for the other in relation to the dimensions of the printing.

Conclusions

Based on the tests performed, this particular hospital ID wristband is considered MR safe and will not pose a hazard to a patient undergoing an MRI examination. Importantly, it is not necessary to remove this item for a patient referred for MRI.  相似文献   

9.

Purpose

We evaluated the ability of diffusion-weighted imaging (DWI) to detect bone metastasis by comparing the results obtained using this modality with those obtained using 11C-methionine (MET) positron emission tomography (PET) and bone scintigraphy.

Materials and methods

This retrospective study involved 29 patients with bone metastasis. DWI was obtained using a single-shot echo planar imaging (EPI) sequence with fat suppression using a short inversion time inversion recovery sequence. The detection capabilities of DWI for bone metastases were compared with those of whole body MET PET (in 19 patients) and 99mTc-methylene diphosphonate bone scintigraphy (in 15 patients).

Results

Among the 19 patients who were diagnosed using DWI and PET, the PET identified 39 bone metastases, while the DWI identified 60 metastases out of 69 metastases revealed with conventional magnetic resonance imaging (MRI). Among the 15 patients who were diagnosed using DWI and bone scintigraphy, the bone scintigraphy identified 18 bone metastases, while the DWI identified 72 metastases out of 78 metastases revealed with conventional MRI. The overall bone metastasis detection rates were 56.5% for PET, 23.1% for bone scintigraphy and 92.3% for DWI.

Conclusion

DWI is a very sensitive method for detecting bone metastasis and is superior to MET PET and bone scintigraphy in terms of its detection capabilities.  相似文献   

10.

Objective

The purpose of this study is to determine the feasibility of measuring total uterine blood flow in pregnancy using magnetic resonance imaging (MRI) technique.

Methods

Uterine blood flow was determined in pregnant women in whom MRI was being carried out to assess a fetal anomaly. A two-dimensional time-of-flight magnetic resonance (MR) angiogram sequence was performed. Scout images and a peripherally gated phase contrast MR sequence were planned to study simultaneous blood flow in the uterine and ovarian arteries.

Results

The MR pelvic angiogram sequence was completed in 13 women. The uterine arteries were visualized and their cross-sectional area determined. The complexity of the pelvic blood supply prevented the calculation of blood flow velocity and, thus, total uterine blood flow.

Conclusion

The measurement of total uterine blood flow during pregnancy was not possible using our MR technique. The ovarian vessels were not consistently visualized. Doppler ultrasonography remains the best modality by which to estimate total uterine blood flow in pregnancy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号