首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
BackgroundIn B1 encoded MRI, a realistic non-linear phase RF encoding coil will generate an inhomogeneous B1 field that leads to spatially dependent flip angles. The non-linearity of the B1 phase gradient can be compensated for in the reconstruction, but B1 inhomogeneity remains a problem. The effect of B1 inhomogeneity on tip angles for conventional, B0 encoded MRI, may be minimized using composite pulses. The objective of this study was to explore the feasibility of using composite pulses with non-linear RF phase encoding coils and to identify the most appropriate composite pulse scheme.MethodsRF encoded signals were simulated via the Bloch equation for various symmetric, asymmetric and antisymmetric composite pulses. The simulated signals were reconstructed using a constrained least squares method.ResultsRoot mean square reconstruction errors varied from 6% (for an asymmetric composite pulse) to 9.7% (for an antisymmetric composite pulse).ConclusionAn asymmetric composite pulse scheme created images with fewer artifacts than other composite pulse schemes in inhomogeneous B0 and B1 fields making it the best choice for decreasing the effects of spatially varying flip angles. This is contrary to the conclusion that antisymmetric composite pulses are the best ones to use for spin echo sequences in conventional, B0 encoded, MRI.  相似文献   

2.

Purpose

To examine mesenchymal stem cell (MSC) labeling with micrometer-sized iron oxide particles (MPIOs) for magnetic resonance imaging (MRI)-based tracking and its application to monitoring articular cartilage regeneration.

Methods

Rabbit MSCs were labeled using commercial MPIOs. In vitro MRI was performed with gradient echo (GRE) and spin echo (SE) sequences at 3T and quantitatively characterized using line profile and region of interest analysis. Ex vivo MRI of hydrogel-encapsulated labeled MSCs implanted within a bovine knee was performed with spoiled GRE (SPGR) and T sequences. Fluorescence microscopy, labeling efficiency, and chondrogenesis of MPIO-labeled cells were also examined.

Results

MPIO labeling results in efficient contrast uptake and signal loss that can be visualized and quantitatively characterized via MRI. SPGR imaging of implanted cells results in ex vivo detection within native tissue, and T imaging is unaffected by the presence of labeled cells immediately following implantation. MPIO labeling does not affect quantitative glycosaminoglycan production during chondrogenesis, but iron aggregation hinders extracellular matrix visualization. This aggregation may result from excess unincorporated particles following labeling and is an issue that necessitates further investigation.

Conclusion

This study demonstrates the promise of MPIO labeling for monitoring cartilage regeneration and highlights its potential in the development of cell-based tissue engineering strategies.  相似文献   

3.
Al18B4O33w/Co composite powders were prepared through electroless depositing Co on Al18B4O33 whiskers and the microstructure of the prepared composite powders was adjusted through heat-treatment. The included Co oxide is reduced and the density as well as the crystal perfection of the coatings is improved when annealed at 400 °C in H2 atmosphere. An increase of 105 S m−1 in conductivity together with an increase of 28% in Ms is obtained, resulting in a prominent increase of the permittivity and the permeability. The increase of permittivity, specifically the dielectric relaxation is attributed to the increase of conductivity. The increase of permeability is attributed to the increase of Ms and the microstructure evolution. The increase of electromagnetic parameters in 2-18 GHz band is believed to enhance the electromagnetic wave absorbing performance of the Al18B4O33w/Co composite powders.  相似文献   

4.
Iron oxide/silica (Fe:Si as 1:10 atomic ratio) composite materials have been prepared by calcination for 3 h at different temperatures (400-900 °C) of xerogel precursor obtained via a formamide modified sol-gel process. The process involved TEOS and iron(III) nitrate, nitric acid and formamide. Genesis of the composite materials from the xerogel precursor has been investigated by TGA, DSC, FTIR, XRD, SEM and EDX. Results indicated that all the calcined composites are mainly composed of amorphous iron oxide dispersed as finely divided particles in amorphous silica matrixes. Nitrogen adsorption/desorption isotherms revealed a reversible type I of isotherms indicative of microporosity. However, high SBET surface area and microsporosity were observed for the calcined composite materials (e.g. SBET = 625 m2 g−1, and Sαs = 556 m2 g−1 for the composite calcined at 400 °C). Formation of the porous texture was discussed in terms of the action of formamide, which enhanced strengthening of the silica gel network during evaporation of the more volatile components within the composite body during the drying process.  相似文献   

5.
A novel 3D breath-held Dixon fat–water separated balanced steady state free precession (b-SSFP) sequence for MR cholangiopancreatography (MRCP) is described and its potential clinical utility assessed in a series of patients. The main motivation is to develop a robust breath-held alternative to the respiratory gated 3D Fast Spin Echo (FSE) sequence, the current clinical sequence of choice for MRCP. Respiratory gated acquisitions are susceptible to motion artifacts and blurring in patients with significant diaphragmatic drift, erratic respiratory rhythms or sleep apnea. A two point Dixon fat–water separation scheme was developed which eliminates signal loss arising from B0 inhomogeneity effects and minimizes artifacts from perturbation of the b-SSFP steady state. Preliminary results from qualitative analysis of 49 patients demonstrate robust performance of the 3D Dixon b-SSFP sequence with diagnostic image quality acquired in a 20–24 s breath-hold.  相似文献   

6.
This work presents a simple design for a mobile single-sided nuclear magnetic resonance (NMR) apparatus with a relatively homogeneous static magnetic field (B0) distribution. In the proposed design, the B0 magnetic field of the apparatus is synthesized using only two permanent magnet blocks, i.e., a cube (main) magnet and a small shim magnet placed above the main magnet. The magnetic flux of the shim magnet partially cancels out that of the main magnet, subsequently creating a smooth B0 profile above the shim magnet where low-resolution NMR experiments are performed. Compared with many previously published designs, this straightforward design simplifies the construction of the apparatus and simultaneously generates a B0 field parallel to the apparatus surface, allowing the use of a simple loop-type radiofrequency (RF) coil. Additionally, an apparatus prototype is constructed according to the proposed design. Weighing only 1.8 kg, the constructed apparatus has a compact structure and can be held in the palm of a hand. The apparatus generates a B0 strength of about 0.0746 T. Within a B0 field deviation of 3 mT, the region with a relatively homogeneous B0 distribution extends to about 11 mm above the shim magnet. The proposed apparatus can detect a clear Hahn echo or Carr-Purcell-Meiboom-Gill (CPMG) echoes of a pencil eraser block or a bottle of oil placed on the apparatus in 5 s with signal averaging using an RF transmitter power of only 19 W; the detection range of the apparatus exceeds 6 mm. The strength of the residual static magnetic field gradient of the apparatus is roughly estimated at 0.58 T/m. Applying different CPMG echo spacings in this residual static gradient leads to various transverse relaxation time (T2) contrasts for liquids with distinct viscosities such as water and oil. Two nondestructive inspection applications of the apparatus, including correlating the concentrations of magnetic nanoparticle solutions with their measured transverse relaxation rates (R2) and monitoring the outgassing from an opened bottle of oxygen-supersaturated water by measuring its longitudinal relaxation rate (R1), are also demonstrated.  相似文献   

7.
Surface composition and depth profile of native oxide on Fe67Co18B14Si1 metallic glass has been investigated using Auger electron spectroscopy. The native oxide is compared with chemisorbed oxygen on the cleaned surface. Results indicate that boron segregates on the surface in the presence of oxygen. The low energy L23M45M45 peak of iron in metallic glass is compared with that in crystallized sample and pure iron foil.  相似文献   

8.
Rhenium sulfide nanoparticles are associated with magnetic iron oxide through coprecipitation of iron salts with tetramethylammonium hydroxide. Sizes of the formed magnetic rhenium sulfide composite particles are in the range 5.5-12.5 nm. X-ray diffraction and energy-dispersive analysis of X-rays spectra demonstrate the coexistence of Fe3O4 and ReS2 in the composite particle, which confirm the formation of the magnetic rhenium sulfide composite nanoparticles. The association of rhenium sulfide with iron oxide not only keeps electronic state and composition of the rhenium sulfide nanoparticles, but also introduces magnetism with the level of 24.1 emu g-1 at 14 kOe. Surface modification with monocarboxyl-terminated poly(ethylene glycol) (MPEG-COOH) has the role of deaggregating the composite nanoparticles to be with average hydrodynamic size of 27.3 nm and improving the dispersion and the stability of the composite nanoparticles in water.  相似文献   

9.
T1ρ imaging is useful in a number of clinical applications. T1ρ preparation methods, however, are sensitive to non-uniformities of the B0 magnetic field and the B1 RF field. These common system imperfections can result in image artifacts and quantification errors in T1ρ imaging. We report on a phase-cycling method which can eliminate B1 RF inhomogeneity effects in T1ρ imaging. This method does not only correct for image artifacts but also for T2ρ contamination caused by B1 RF inhomogeneity. The presence of B0 magnetic field inhomogeneity can compromise the effectiveness of this method for B1 RF inhomogeneity correction. We demonstrate that, by combining the spin-locking scheme reported by Dixon et al. (Myocardial suppression in vivo by spin locking with composite pulses. Magn Reson Med 1996; 36:90-94) with phase cycling, we can simultaneously correct B0 magnetic field inhomogeneity effects and B1 RF inhomogeneity effects in T1ρ imaging. Phantom and in vivo data sets are used to demonstrate the proposed methods and to compare them with other existing T1ρ preparation methods.  相似文献   

10.
The α-Fe2O3/SiO2 nanocomposite containing 45 wt% of hematite was prepared by the sol-gel method followed by heating in air at 200 °C. The so-obtained composite of iron(III) nanoparticles dissolved in glassy silica matrix was investigated by X-ray powder diffraction (XRPD), transmission electron microscopy (TEM), and superconducting quantum interference device (SQUID) magnetometry. XRPD confirms the formation of a single-phase hematite sample, whereas TEM reveals spherical particles in a silica matrix with an average diameter of 10 nm. DC magnetization shows bifurcation of the zero-field-cooled (ZFC) and field-cooled (FC) branches up to the room temperature with a blocking temperature TB=65 K. Isothermal M(H) dependence displays significant hysteretic behaviour below TB, whereas the room temperature data were successfully fitted to a weighted Langevin function. The average particle size obtained from this fit is in agreement with the TEM findings. The small shift of the TB value with the magnetic field strength, narrowing of the hysteresis loop at low applied field, and the frequency dependence of the AC susceptibility data point to the presence of inter-particle interactions. The analysis of the results suggests that the system consists of single-domain nanoparticles with intermediate strength interactions.  相似文献   

11.
Echo planar imaging (EPI) is an ultrafast magnetic resonance imaging (MRI) technique that allows one to acquire a 2D image in about 100 ms. Unfortunately, the standard EPI images suffer from substantial geometric distortions, mainly originating from susceptibility differences in adjacent tissues. To reduce EPI distortions, correction methods based on a field map, which is a map of the off-resonance frequencies, have been developed. In this work, a nonlinear least squares estimator is used to optimize the estimation of the field map of the B0 field. The model of the EPI and reference data includes parameters for the phase evolution, the complex magnitude, the relaxation of the MRI signal and the EPI-specific phase difference between odd and even echoes, and from these parameters, additional corrections might be computed. The reference data required to estimate the field map can be acquired with a modified EPI-sequence. The proposed method is tested on simulated as well as experimental data and proves to be significantly more robust against noise, compared to the previously suggested method.  相似文献   

12.
A new amorphous alloy has been recently introduced which shows a saturation magnetic induction Bs of 1.64 T which is compared with Bs=1.57 T for a currently available Fe-based amorphous alloy and decreased magnetic losses. Such a combination is rare but can be explained in terms of induced magnetic anisotropy being reduced by the alloy's chemistry and its heat treatment. It has been found that the region of magnetization rotation in the new alloy is considerably narrowed, resulting in reduced exciting power in the magnetic devices utilizing the material. Efforts to increase Bs also have been made for nanocrystalline alloys. For example, a nanocrystalline alloy having a composition of Fe80.5Cu1.5Si4B14 shows Bs exceeding 1.8 T. The iron loss at 50 Hz and at 1.6 T induction in a toroidal core of this material is 0.46 W/kg which is 2/3 that of a grain-oriented silicon steel. At 20 kHz/0.2 T excitation, the iron loss is about 60% of that in an Fe-based amorphous alloy which is widely used in power electronics. Another example is a Fe85Si2B8P4Cu1 nanocrystalline alloy with a Bs of 1.8 T, which is reported to exhibit a magnetic core loss of about 0.2 W/kg at 50 Hz and at 1.5 T induction. This article is a review of these new developments and their impacts on energy efficient magnetic devices.  相似文献   

13.
PurposeTo develop schemes that deliver faithful 2D slices near field heterogeneities of the kind arising from non-ferromagnetic metal implants, with reduced artifacts and shorter scan times.MethodsAn excitation scheme relying on cross-term spatio-temporal encoding (xSPEN) was used as basis for developing the new inhomogeneity-insensitive, slice-selective pulse scheme. The resulting Fully refOCUSED cross-term SPatiotemporal ENcoding (FOCUSED-xSPEN) approach involved four adiabatic sweeps. The method was evaluated in silico, in vitro and in vivo using mice models, and compared against a number of existing and of novel alternatives based on both conventional and swept RF pulses, including an analogous method based on LASER's selectivity spatial selectivity.ResultsCalculations and experiments confirmed that multi-sweep derivatives of xSPEN and LASER can deliver localized excitation profiles, centered at the intended positions and endowed with enhanced immunity to B0 and B1 distortions. This, however, is achieved at the expense of higher SAR than non-swept counterparts. Furthermore, single-shot FOCUSED-xSPEN and LASER profiles covered limited off-resonance ranges. This could be extended to bands covering arbitrary off-resonance values with uniform slice widths, by looping the experiments over a number of scans possessing suitable transmission and reception offsets.ConclusionsA series of novel approaches were introduced to select slices near metals, delivering robustness against Bo and B1+ field inhomogeneities.  相似文献   

14.
Rotational transitions of 1-nitropropene arising from the ground vibrational state and from three excited states of the nitro torsional vibration have been assigned. The values of the rotational constants in MHz are: A0=10 650B0=2028.56C01722.16A110 615 B1=2028.47 C1=1725.11 A210 570 B2 2028.31 C2= 1727.32 A3= 10 512 B32028.11 C3=1729.37The dipole moment components are μa = 4.52 D, μb = 0.42 D and μtotal = 4.54 D. From the lack of observable internal rotation splittings the barrier to internal rotation of the methyl group is shown to be greater than 2250 cal/mole.  相似文献   

15.
We demonstrate modified photon echoes in Eu3+:Y2SiO5 by controlling the inhomogeneous broadening of the optical transition in Eu3+. These modified photon echoes are shown to be capable of storing phase and amplitude modulation.  相似文献   

16.
Tunneling spectra of the A1/δ-GaAs junctions fabricated by molecular-beam epitaxy in the regime of “intimate” contact of A1 with GaAs (100) were studied at 1.6 K in a magnetic field B parallel to the two-dimensional electron-gas layer. The concentration of 2D electrons in the δ-layer grown at a distance of 20 nm from the A1/GaAs interface was 1.1 × 1012 cm?2 and corresponded to a partial filling of only the lowest subband E 0. The tunneling spectra exhibited many-particle features, viz., a zero-bias anomaly, lines of longitudinal optical (LO) phonons, and characteristic “dips” corresponding to the energies E i of the 2D subbands. In the B fields below the critical value B c ?11 T, the levels of 2D subbands underwent the usual diamagnetic shifts. At BB c , the E 1 (B) term pinning and the anticrossing of the E 1(B) and E 0(B)+2?ωLO terms were observed, where ?ωLO is the LO-phonon energy in GaAs. The observed effects are interpreted as manifestations of resonance intersubband polarons arising in the δ-layer upon reaching the E 1(B c )?E 0(B c )=2?ωLO resonance.  相似文献   

17.
CoFeRhO4 has been studied by Mössbauer spectroscopy and X-ray diffraction. The crystal is found to have a cubic spinel structure with the lattice constant a0=8.451±0.005 Å. The iron ions are in ferric states. The temperature dependence of the magnetic hyperfine field is analyzed by the Néel theory of ferrimagnetism. The intersublattice superexchange interaction is antiferromagnetic and strong with a strength of JAB=−12.39kB while the intrasublattice superexchange interactions are weak with strengths of JAA=−4.96kB and JBB=6.20kB. As the temperature increases toward the Néel temperature TN, a systematic line broadening effect in the Mössbauer spectrum is observed and interpreted to originate from different temperature dependences of the magnetic hyperfine fields at various iron sites.  相似文献   

18.
The positions of the K-absorption edges of iron are recorded for five crystals: Fe0.885O, Fe0.905O, Fe3O4, Fe2O3 and Fe metal, and for two amorphous solids: oxide glass ([Na2O · 2SiO2]0.8 [Fe2O3]0.2) and metallic glass (Fe36Cr32Ni14P12B6). It is observed that there is a correlation between the positive X-ray K- absorption edge chemical shift and the effective coordination charge. The ionic state of iron in oxide glass is identical to the ferric iron in Fe2O3 as shown by the same positions of iron K-absorption edges in this glass and Fe2O3. The K-edge of the metallic glass appears 6.5 eV higher than that of the pure iron edge, which suggests that the bonding of iron in metallic glass is different from the pure iron metal.  相似文献   

19.
20.
The size-, surface- and proximity-effects are combined for calculating the critical temperature and some unusual electromagnetic properties of superfine superconducting NbTi filaments (i.e. with a diameterd s < 0·1 μm) in the neighbourhood of normal metal (Cu). It is shown that the existence of the one-dimensional flux line lattice is responsible for the extremely large values of the critical current densities in low magnetic fields (B < 0·2B c2,B c2 — the upper critical magnetic field), for the maximum of the volume pinning force at low magnetic fields (B m ≈ 0·1B c2, comparing withB m≈ 0·5B c2 in usual macroscopic multifilamentary NbTi superconductors), as well as for the peculiar minimum of the magnetization after reversing the magnetic field direction. The possible role of the frozen-in flux lines in creating flux lines of opposite direction is sketched. It is proposed that for practical purposes the superconducting filaments should be coated with electrically insulating material (e.g. cupro-nickel or dielectric) to destroy the electro-magnetic coupling between the filaments and to ensure low ac losses in the composite.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号