首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 151 毫秒
1.
The International Standard ISO 140-5 on field measurements of airborne sound insulation of façades establishes that the directivity of the measurement loudspeaker should be such that the variation in the local direct sound pressure level (ΔSPL) on the sample is ΔSPL < 5 dB (or ΔSPL < 10 dB for large façades). This condition is usually not very easy to accomplish nor is it easy to verify whether the loudspeaker produces such a uniform level. Direct sound pressure levels on the ISO standard façade essentially depend on the distance and directivity of the loudspeaker used. This paper presents a comprehensive analysis of the test geometry for measuring sound insulation and explains how the loudspeaker directivity, combined with distance, affects the acoustic level distribution on the façade.The first sections of the paper are focused on analysing the measurement geometry and its influence on the direct acoustic level variations on the façade. The most favourable and least favourable positions to minimise these direct acoustic level differences are found, and the angles covered by the façade in the reference system of the loudspeaker are also determined. Then, the maximum dimensions of the façade that meet the conditions of the ISO 140-5 standard are obtained for the ideal omnidirectional sound source and the piston radiating in an infinite baffle, which is chosen as the typical radiation pattern for loudspeakers.Finally, a complete study of the behaviour of different loudspeaker radiation models (such as those usually utilised in the ISO 140-5 measurements) is performed, comparing their radiation maps on the façade for searching their maximum dimensions and the most appropriate radiation configurations.  相似文献   

2.
This paper presents a new verification procedure for sound source coverage according to ISO 140–5 requirements. The ISO 140–5 standard applies to the measurement of façade insulation and requires a sound source able to achieve a sufficiently uniform sound field in free field conditions on the façade under study. The proposed method involves the electroacoustic characterisation of the sound source in laboratory free field conditions (anechoic room) and the subsequent prediction by computer simulation of the sound free field radiated on a rectangular surface equal in size to the façade being measured. The loudspeaker is characterised in an anechoic room under laboratory controlled conditions, carefully measuring directivity, and then a computer model is designed to calculate the acoustic free field coverage for different loudspeaker positions and façade sizes. For each sound source position, the method provides the maximum direct acoustic level differences on a façade specimen and therefore determines whether the loudspeaker verifies the maximum allowed level difference of 5 dB (or 10 dB for façade dimensions greater than 5 m) required by the ISO standard. Additionally, the maximum horizontal dimension of the façade meeting the standard is calculated and provided for each sound source position, both with the 5 dB and 10 dB criteria. In the last section of the paper, the proposed procedure is compared with another method used by the authors in the past to achieve the same purpose: in situ outdoor measurements attempting to recreate free field conditions. From this comparison, it is concluded that the proposed method is able to reproduce the actual measurements with high accuracy, for example, the ground reflection effect, at least at low frequencies, which is difficult to avoid in the outdoor measurement method, and it is fully eliminated with the proposed method to achieve the free field requisite.  相似文献   

3.
4.
The influence of urban morphology of low-density built-up areas on spatial noise level attenuation of flyover aircrafts is investigated at a mesoscale. Six urban morphological parameters, including Building Plan Area Fraction, Complete Aspect Ratio, Building Surface Area to Plan Area Ratio, Building Frontal Area Index, Height-to-Width Ratio, and Horizontal Distance of First-row Building to Flight Path, have been selected and developed. Effects of flight altitude and horizontal flight path distance to site, on spatial aircraft noise attenuation, are examined, considering open areas and façades. Twenty sampled sites, each of 250 m * 250 m, are considered. The results show that within 1000 m horizontal distance of flight path to a site, urban morphology plays an important role in open areas, especially for the buildings with high sound absorption façades, where the variance of average noise level attenuation among different sites is about 4.6 dB at 3150 Hz. The effect of flight altitude of 200–400 ft on average noise level attenuation is not significant, within about 2 dB at both 630 Hz and1600 Hz in open areas. Urban morphological parameters influence the noise attenuation more in open areas than that on façades. Spatial noise attenuation of flyover aircrafts is mainly correlated to Building Frontal Area Index and Horizontal Distance of First-row Building to Flight Path.  相似文献   

5.
The Façade Acoustic Insulation Index is one of the most disputed parameters for residential and non-residential buildings. The real performance of the façades does not often agree with the calculated one during the design stage. The field measurement sessions are usually carried out using pink noise spectra, as suggested by the International Standards ISO 717-1. In the present paper six mean spectra derived from in field measurements were proposed: urban toads, traffic lights, roundabouts, freeways, Highways, very high speed trains, high speed trains, and low speed trains. The proposed spectra were equalized against acoustic distortion and were used to measure the noise abatements in a terraced house and in a classroom façade. The highest abatements result for spectra with high levels at high frequencies, better absorbed than low ones by façade elements and frames. The spectrum adaptation terms were also calculated both for the standard and the proposed spectra and were used to predict the façade abatements in compliance with EN ISO 12354-3: the values Cj calculated from the proposed spectra provided more reliable results than the terms C and Ctr (ISO 717-1) and represent a useful tool to predict the noise façade abatements.  相似文献   

6.
A multi-faceted study is conducted with the objective of estimating the potential fiscal savings in annoyance and sleep disturbance related health costs due to providing improved building acoustic design standards. This study uses balcony acoustic treatments in response to road traffic noise as an example. The study area is the State of Queensland in Australia, where regional road traffic noise mapping data is used in conjunction with standard dose–response curves to estimate the population exposure levels. The background and the importance of using the selected road traffic noise indicators are discussed. In order to achieve the objective, correlations between the mapping indicator (LA10 (18 hour)) and the dose response curve indicators (Lden and Lnight) are established via analysis on a large database of road traffic noise measurement data. The existing noise exposure of the study area is used to estimate the fiscal reductions in health related costs through the application of simple estimations of costs per person per year per degree of annoyance or sleep disturbance. The results demonstrate that balcony acoustic treatments may provide a significant benefit towards reducing the health related costs of road traffic noise in a community.  相似文献   

7.
This paper presents an experimental work on active control of sound transmission through a restricted opening bottom hinged window. The main goal of the work is to demonstrate the feasibility of the active technique to limit the loss of attenuation due to the aperture of windows, and its application to aircraft fly-over incident noise. The experimental window is placed in an exposed façade of a dwelling close to an airport and subject to fly-by aircraft noise. The active control is configured to cancel the pressure at the aperture using a single-input single-output feedforward adaptive system. As a result, a reduction of sound transmission is achieved with low power consumption. In global terms, an increase of almost 3 dB of transmission loss (with respect to the partially opened window insulation values) in the low frequency range (below 160 Hz and according to the National Danish Method for evaluating low frequency noise) is demonstrated, which is equivalent to a reduction of 50% in the loss of insulation caused by opening the window.  相似文献   

8.
《Ultrasonics sonochemistry》2014,21(6):1988-1993
Even though much knowledge on acoustic cavitation and its application has been accumulated over the past decades, further research is still required to develop industrial uses of acoustic cavitation. It is because the available information is mainly based on small-scale sonoreactors and the design and optimization of sonoreactors for large-scale applications have not been widely studied. In this study, the effects of liquid height/volume, initial concentration of the reactant and input acoustic power on sonochemical oxidation reactions including iodide ion oxidation, As(III) oxidation, and hydrogen peroxide generation were investigated using a 291 kHz sonoreactor with various liquid height/volumes (50, 100, 200, 300, 500, and 1000 mL) and input powers (23, 40, and 82 W). As the liquid height/volume and the input power changed, the power density varied from 23 to 1640 W/L and the maximum cavitation yields of triiodide ion for 23, 40, and 82 W were observed at 0.05, 0.1, and 0.2/0.3 L, respectively. It was found that low power was more effective for the small volume and the large volume required high power level and the moderate power density, approximately 400 W/L, was suggested for the sonochemical oxidation of iodide ion in the 291 kHz sonoreactor in this study. Similar results were observed in the generation of hydrogen peroxide and the sonochemical oxidation of As(III) to As(V). It was also revealed that KI dosimetry could be applicable for the estimation of the sonochemical reactions of non-volatile compounds such as As(III).  相似文献   

9.
This work presents a photogrammetric technique that provides geometric and thermal information about building façades. It uses low cost and portable scale bars, specially designed for thermal imaging, and processing software based on single image rectification. Image rectification corrects the original photo displacement due to the projection and perspective, and radial distortions introduced by the lens of the camera.The technique is tested by comparing laser scanning and thermal data. Seven segments of different orientation and length are selected for the measurement. Accuracy tests show errors between 44 mm and 151 mm. Precision values range between 22 mm and 61 mm for a maximum length of 7259 mm. The accuracy and precision results obtained for the technique open the possibility of extending its use to building inspection tasks.  相似文献   

10.
This paper focuses on the frequency analysis of acoustic signals produced by partial discharges (PDs) in insulation oil and the positioning of the PD occurrence for application in the diagnosis of oil-insulated transformers. Three types of electrode systems; the needle–plane, the plane–plane, and the wire–wire structures were assembled to simulate the partial discharge in insulation oil. A low-noise amplifier and a de-coupler were designed to detect the acoustic signal with high-sensitivity. The frequency ranges of the acoustic signal were 60–270 kHz in the needle–plane electrode system, 45–250 kHz in the plane–plane electrode system, and 50–180 kHz in the wire–wire electrode system. Their peak frequencies were 145 kHz, 118 kHz and 121 kHz, respectively.The position of the PD occurrence was calculated from the time difference of arrival (TOA) using three acoustic emission (AE) sensors. The position was found within a 1% error in the experimental set-up.  相似文献   

11.
Water removal is an essential step during crude oil production due to several problems such as increased transportation costs and high corrosion rate due to dissolved salts. Indirect low frequency ultrasonic energy (US), using baths, has been recently proposed as an effective alternative for crude oil demulsification. However, the reactor position during sonication and its influence on the demulsification efficiency for crude oil has not been evaluated. In this sense, the aim of this study was to develop an automated system based on an open source hardware for mapping the acoustic field distribution in an US bath operating at 35 kHz using a hydrophone. Data acquired with this system provided information to evaluate the demulsification efficiency in the different positions of the US bath and correlate it with the acoustic intensity distribution. The automated 3D-mapping system revealed a higher acoustic intensity in the regions immediately above the transducers (ca. 0.6 W cm−2), while the other regions presented a relatively lower intensity (ca. 0.1 W cm−2). Experimental data demonstrated that reactors positioned in the most intense acoustic regions provided a much higher efficiency of demulsification in comparison with the ones positioned in the less intense acoustic field regions. Demulsification efficiency up to 93% was obtained with 15 min of sonication (100% amplitude) using few amount of chemical demulsifier. Hence, this work demonstrated that the information acquired with the developed mapping system could be used for inducing a higher efficiency of demulsification only by finding the more suitable position of reactor in the US bath, which certainly will help development of appropriate reactors design when looking for such approach.  相似文献   

12.
In this research work, a statistical analysis of the CO2 laser beam welding of dual phase (DP600)/transformation induced plasticity (TRIP700) steel sheets was done using response surface methodology. The analysis considered the effect of laser power (2–2.2 kW), welding speed (40–50 mm/s) and focus position (?1 to 0 mm) on the heat input, the weld bead geometry, uniaxial tensile strength, formability limited dome height and welding operation cost. The experimental design was based on Box–Behnken design using linear and quadratic polynomial equations for predicting the mathematical models. The results indicate that the proposed models predict the responses adequately within the limits of welding parameters being used and the welding speed is the most significant parameter during the welding process.  相似文献   

13.
Propagation of impulsive sound around buildings and induced structural loading are investigated experimentally and numerically. Experiments were conducted on a rectangular building at Virginia Tech using sonic booms generated by shaped charges with an explosive weight of 0.78 kg, constructed from detonation cord. These experiments were simulated with a three-dimensional numerical model, in the context of geometrical acoustics (GA), by combining the image source method for the reflected field (specular reflections) with an extension of the Biot–Tolstoy–Medwin (BTM) method for the diffracted field. In this model, it is assumed that the acoustic propagation is linear and that all surfaces are acoustically rigid. This numerical model is validated against a boundary element (BE) solution and experimental data, showing a good overall agreement. The key advantages of this GA modeling approach for this application include the ability to model large three-dimensional domains over a wide frequency range and also to decompose the sound field into direct, reflected, and diffracted components, thus providing a better understanding of the sound-propagation mechanisms. Finally, this validated numerical model is used to investigate sound propagation around a cluster of six rectangular buildings, for a range of elevated source positions simulating sonic booms from aircraft.  相似文献   

14.
Lead Zirconate Titanate (PZT) is a piezo-electric ceramic material that needs to be characterized for its potential use in microelectronics. Energy dispersive X-ray analysis (EDX) is conducted to determine the chemical composition of the PZT ceramics. The scanning electron microscope (SEM) is performed to study the surface morphology, grain structure and grain boundaries. The SEM image helps us to understand the surface wave propagation and scattering phenomena by the PZT and the reason for its anisotropy and inhomogeneity due to the grain structure. In this paper scanning acoustic microscopy at 100 MHz excitation frequency is conducted for determining mechanical properties of PZT. Earlier works reported only the longitudinal wave speed in PZT while in this paper longitudinal, shear and surface acoustic wave speeds of sintered PZT are measured from its acoustic material signature (AMS) curves, also known as V(z) curves. AMS or V(z) curve is the variation of the output voltage as a function of the distance between the acoustic lens focal point and the reflecting surface. The average velocities of longitudinal, shear and surface acoustic waves in a PZT specimen are determined from its V(z) curve generated at 100 MHz excitation frequency and found to be over 5000 m/s, over 3000 m/s and between 2500 and 3000 m/s, respectively. From these velocities all elastic constants of the specimen are obtained.  相似文献   

15.
Noise and air pollution problems become significantly in a busy city such as Hong Kong since buildings usually located close to the heavy traffic lines. Traditional openable window cannot fulfill all the functions of noise reduction, lighting and natural ventilation. A new ventilated window combines the multiple quarter-wave resonators (silencer) and the new wing wall designs aim to make a balance between acoustic and ventilation performances at the same time. Furthermore, the use of multiple-wave resonators and membrane absorber which made plexi-glass plastic sheet replace absorption material can improve the durability; avoid small particle emission and light transparency.The acoustic and ventilation performance of new ventilated window were examined in this study. Noise attenuation of the new ventilated window design has improved significantly by combine flexible absorber and quarter-wave resonator effects. Transmission loss of 10–22 dB can be achieved in the frequency range of 500 Hz–4 kHz band. Outlet air flow velocity of ventilated window design is higher than that of “an open window”. Thus, both the acoustics and ventilation performance of the new ventilated window is essential. Wind-driven natural ventilation is an effective strategy in maintaining the comfort and health of the indoor environment.  相似文献   

16.
The present work deals with the mapping of an ultrasonic bath for the maximum extraction of mangiferin from Mangifera indica leaves. I3 liberation experiments (chemical transformations) and extraction (physical transformations) were carried out at different locations in an ultrasonic bath and compared. The experimental findings indicated a similar trend in variation in an ultrasonic bath by both these methods. Various parameters such as position and depth of vessel in an ultrasonic bath, diameter and shape of a vessel, frequency and input power which affect the extraction yield have been studied in detail. Maximum yield of mangiferin obtained was approximately 31 mg/g at optimized parameters: distance of 2.54 cm above the bottom of the bath, 7 cm diameter of vessel, flat bottom vessel, 6.35 cm liquid height, 122 W input power and 25 kHz frequency. The present work indicates that the position and depth of vessel in an ultrasonic bath, diameter and shape of a vessel, frequency and input power have significant effect on the extraction yield. This work can be used as a base for all ultrasonic baths to obtain maximum efficiency for ultrasound assisted extraction.  相似文献   

17.
Unattended background speech is a known source of cognitive and subjective distraction in open-plan offices. This study investigated whether the deleterious effects of background speech can be affected by room acoustic design that decreases speech intelligibility, as measured by the Speech Transmission Index (STI). The experiment was conducted in an open-plan office laboratory (84 m2) in which four acoustic conditions were physically built. Three conditions contained background speech. A quiet condition was included for comparison. The speech conditions differed in terms of the degree of absorption, screen height, desk isolation, and the level of masking sound. The speech sounds simulated an environment where phone conversations are heard from different locations varying in distance. Ninety-eight volunteers were tested. The presence of background speech had detrimental effects on the subjective perceptions of noise effects and on cognitive performance in short-term memory and working memory tasks. These effects were not attenuated nor amplified within a three-hour working period. The reduction of the STI by room acoustic means decreased subjective disturbance, whereas the effects on cognitive performance were somewhat smaller than expected. The effects of room acoustic design on subjective distraction were stronger among noise-sensitive subjects, suggesting that they benefited more from acoustic improvements than non-sensitive subjects. The results imply that reducing the STI is beneficial for performance and acoustic satisfaction especially regarding speech coming from more distant desks. However, acoustic design does not sufficiently decrease the distraction caused by speech from adjacent desks.  相似文献   

18.
Windows are the weakest part of a façade in terms of acoustic performance: the weighted sound insulation index (Rw), measured according to ISO 140-3, is the fundamental parameter to evaluate the façade acoustic insulation.The paper aims at developing an artificial neural network (ANN) model to estimate the Rw value of wooden windows based on a limited number of windows parameters; this is a new approach because acoustic phenomena are non-linear and affected by a plurality of factors and, therefore, usually investigated through experimentation.Data set is taken from experimental campaigns carried out at the Laboratory of Acoustics, University of Perugia. A multilayer feed-forward approach was chosen and the model was implemented in MATLAB. On the basis of the results obtained by means of a preliminary training and test campaign of several ANN architectures, five main parameters were selected as network inputs: window typology, frame and shutters thickness, number of gaskets, Rw of glazing; Rw value of the window is the network output. Different ANN configurations were trained and a root mean-square error less than 3% was obtained, comparable to measurement uncertainty.This approach allows to develop a model which, with input parameters varying within appropriate ranges, can easily estimate the acoustic performance of wooden windows without experimental campaign on prototypes, saving both money and time. If the training data set is large enough, the presented approach could be very useful for design and optimization of acoustic performance of new products.  相似文献   

19.
《Current Applied Physics》2010,10(4):1053-1058
Effect of temperature on ultrasonic attenuation in BCC structured (CsCl-type) thallium halides (TlCl and TlBr) have been investigated in a wide temperature range 50–500 K for longitudinal and shear modes along [1 0 0], [1 1 0] and [1 1 1] directions of propagation. Starting with nearest neighbour distance and repulsive parameter and taking interactions up to next nearest neighbours, second and third order elastic moduli have been evaluated, which in turn have been used for evaluating thermal relaxation time, Gruneisen numbers, acoustic coupling constants, ultrasonic velocity and ultrasonic attenuation. Ultrasonic attenuation in these bcc structured crystalline materials has been found less than the fcc crystalline materials. The results have been discussed and compared with available data.  相似文献   

20.
We present to our knowledge the first application of Raman microscopic imaging to cementitious materials. This technique yielded the composition and phase distribution (spatial resolution ≈ 500 nm) in samples of cement stone taken from façade elements of four Swiss buildings covering the period of 1892–1924. Raman maps of Roman cement, a predecessor of modern Portland cement, reveal the chemical heterogeneity of clinker remnants consisting of various crystalline, polymorphic, and amorphous phases and visualize different crystal orientations. Our findings include the observation of the γ‐polymorph of Ca2SiO4 – previously, only detected in Portland cement – and Raman spectra of calcium aluminate (ferrite) interstitial phases in Roman cement showing significant differences to the corresponding phases in Portland cement clinker. Furthermore, calcite, vaterite, gypsum, and ettringite were identified in the rim of a nonhydrated residual nodule. Beyond binder remnants, aggregates in the form of spherical (≤500 µm diameter) slag and irregularly shaped pigment particles were analyzed. Here, we focused on the unambiguous identification of compounds in complex matrices by comparing sample spectra with database and own reference spectra. A Raman map collected on blast furnace slag in cement stone shows the spatial distribution of calcite, quartz glass and pyrite. Furthermore, several Fe‐containing, Si‐containing, and Pb‐containing phases were identified. The analysis of pigments partly confirmed and partly contradicted the bequeathed historic recipe of a cement stone façade. These results have direct implications in the field of conservation and restoration and generally demonstrate the potential of Raman imaging to provide deeper understanding of (historic) building materials. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号