首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 125 毫秒
1.
Single clouds of cavitation bubbles, driven by 254 kHz focused ultrasound at pressure amplitudes in the range of 0.48–1.22 MPa, have been observed via high-speed shadowgraphic imaging at 1 × 106 frames per second. Clouds underwent repetitive growth, oscillation and collapse (GOC) cycles, with shock-waves emitted periodically at the instant of collapse during each cycle. The frequency of cloud collapse, and coincident shock-emission, was primarily dependent on the intensity of the focused ultrasound driving the activity. The lowest peak-to-peak pressure amplitude of 0.48 MPa generated shock-waves with an average period of 7.9 ± 0.5 μs, corresponding to a frequency of f0/2, half-harmonic to the fundamental driving. Increasing the intensity gave rise to GOC cycles and shock-emission periods of 11.8 ± 0.3, 15.8 ± 0.3, 19.8 ± 0.2 μs, at pressure amplitudes of 0.64, 0.92 and 1.22 MPa, corresponding to the higher-order subharmonics of f0/3, f0/4 and f0/5, respectively. Parallel passive acoustic detection, filtered for the fundamental driving, revealed features that correlated temporally to the shock-emissions observed via high-speed imaging, p(two-tailed) < 0.01 (r = 0.996, taken over all data). Subtracting the isolated acoustic shock profiles from the raw signal collected from the detector, demonstrated the removal of subharmonic spectral peaks, in the frequency domain. The larger cavitation clouds (>200 μm diameter, at maximum inflation), that developed under insonations of peak-to-peak pressure amplitudes >1.0 MPa, emitted shock-waves with two or more fronts suggesting non-uniform collapse of the cloud. The observations indicate that periodic shock-emissions from acoustically driven cavitation clouds provide a source for the cavitation subharmonic signal, and that shock structure may be used to study intra-cloud dynamics at sub-microsecond timescales.  相似文献   

2.
This paper describes the application of continuous-wave (CW) and tone-burst (TB) vibro-acoustography (VA) experiments for imaging a flawed composite plate. For both modes, the ultrasound frequency is set at f1 = 3 MHz and f2 = 3 MHz + ∣Δf∣. The plate was placed at the focus of the transducer and scanned point-by-point over an area of 60 mm by 50 mm on its frontal face with an increment step equal to 0.25 mm/pixel. The resulting acoustic emission amplitude at ∣Δ f∣ is recorded. For the CW mode the difference frequency was set at ∣Δf∣ = 12.9 kHz. For the TB mode, the burst-emitted signal was 100 μs long at a pulse repetition frequency (PRF) of 100 Hz corresponding to bursts of 300 cycles at 3 MHz, and the difference frequency was set at ∣Δf∣ = 44 kHz. The resulting VA images readily show the shape of the flaws. The images also reveal considerable detail of internal substructures such as the fibers used to reinforce the plate. However, the CW VA image shows an artifact caused by the effect of ultrasound standing waves established between the plate and the concave surface of the transducer, resulting in masking some of the flaws. On the other hand, the TB-VA image is free from such artifact. Despite some advantages of using TB-VA, there are some limitations related to this mode. Advantages and limitations of using the two modes are discussed.  相似文献   

3.
A capillary wave was created on a surface by vibrating from the bottom of a container. When the amplitude of the container vibration approached the critical point, called the onset state, the surface broke up and bursted into very small drops on the air. The numerical analysis was used to determine the amplitude of the onset. The onset point was found to be 0.349 μm at f = 500 kHz. The critical amplitude hcr was determined by using a multi-Fourier horn nozzle (MFHN) device. The onset point was measured to be 0.37 μm using a laser Doppler vibrometer (LDV) with the MFHN at f = 486 kHz. These drops indicate that particle size distributions of 10.8 μm and 7.0 μm were produced by the MFHN at f = 289 kHz and f = 486 kHz, respectively. These results agreed with those obtained using Kelvin’s equation, which predicted D = 0.34λ.  相似文献   

4.
Europium doped BaAl12O19 powder phosphors have been synthesized by combustion process within few minutes. The phosphors have been characterized by XRD, SEM, FT-IR, EPR and PL techniques. The EPR spectrum exhibits an intense resonance signal at g=1.96 characteristic of Eu2+ ions. In addition to this two weak resonance signals have been observed at g=2.28 and g=4.86. The population of the spin levels (N) for the resonance signal at g=1.96 is calculated as a function of temperature. By post-treating the phosphor at 1350 °C under a reducing atmosphere, it is observed that the population of spin levels has been increased five times. The excitation spectrum shows a peak at 326 nm with a shoulder at 290 nm. Upon excitation at 326 nm, the emission spectrum exhibits a well defined broad band with maximum at 444 nm emitting a blue light corresponding to 4f65d→4f7 transition. The luminescence intensity also has been enhanced to 60% by post-treating the phosphor at 1350 °C under a reducing atmosphere.  相似文献   

5.
Dual-perspective high-speed imaging and acoustic detection is used to characterise cavitation activity at the tip of a commercial 20 kHz (f0) ultrasonic horn, over 2 s sonications across the range of input powers available (20 – 100%). Imaging at 1 × 105 frames per second (fps) captures cavitation-bubble cluster oscillation at the horn-tip for the duration of the sonication. Shadowgraphic imaging at 2 Mfps, from an orthogonal perspective, probes cluster collapse and shock wave generation at higher temporal resolution, facilitating direct correlation of features within the acoustic emission data generated by the bubble activity. f0/m subharmonic collapses of the primary cavitation cluster directly beneath the tip, with m increasing through integer values at increasing input powers, are studied. Shock waves generated by periodic primary cluster collapses dominate the non-linear emissions of the cavitation noise spectra. Transitional input powers for which the value of m is indistinct, are identified. Overall shock wave content within the emission signals collected during sonications at transitional input powers are reduced, relative to input powers with distinct m. The findings are relevant for the optimisation of applications such as sonochemistry, known to be mediated by bubble collapse phenomena.  相似文献   

6.
Shen CC  Su SY  Cheng CH  Yeh CK 《Ultrasonics》2012,52(1):25-32

Objective

The goal of this work is to examine the effects of pulse-inversion (PI) technique in combination with dual-frequency (DF) excitation method to separate the high-order nonlinear responses from microbubble contrast agents for improvement of image contrast. DF excitation method has been previously developed to induce the low-frequency ultrasound nonlinear responses from bubbles by using the composition of two high-frequency sinusoids (f1 and f2).

Motivation

Although the simple filtering was conventionally utilized to provide signal separation, the PI approach is better in the sense that it minimizes the mutual interferences among these high-order nonlinear responses in the presence of spectral overlap. The novelty of the work is that, in addition to the common PI summation, the PI subtraction was also applied in DF excitation method.

Methods

DF excitation pulses having an envelope frequency of 3 MHz (i.e., f1 = 8.5 MHz and f2 = 11.5 MHz) with pulse lengths of 3-10 μs and the pressure amplitudes from 0.5 to 1.5 MPa were used to interrogate the nonlinear responses of SonoVue™ microbubbles in the phantom experiments. The high-order nonlinear responses in the DF excitation were extracted for contrast imaging using PI summation for even-order nonlinear components or PI subtraction for odd-order nonlinear ones.

Results

Our results indicated that, as compared to the conventional filtering technique, the PI processing effectively increases the contrast-to-tissue ratio (CTR) of the third-order nonlinear response at 5.5 MHz and the fourth-order nonlinear response at 6 MHz by 2-5 dB. For these high-order nonlinear components, the CTR increase varies with the transmission pressures from 0.5 to 1.5 MPa due to the microbubbles’ displacement induced by the radiation force of DF excitation.

Conclusions

For DF excitation technique, the PI processing can help to extract either the odd-order or the even-order nonlinear components for higher CTR estimates.  相似文献   

7.
A blue phosphor, BaMgAl10O17:Eu2+, has been synthesized in the furnace at a temperature of 500 °C by solution combustion method. The formation of the as-prepared BaMgAl10O17:Eu2+ phosphor was confirmed by the powder X-ray diffraction technique. The EPR spectrum exhibited an intense resonance signal centered at g=4.63 at 150 mT along with a number of resonances in the vicinity of g>2.0 and g<2.0. The number of spins participating in resonance (N) and the susceptibility (c) for the resonance signal at g=4.63 have been calculated as a function of temperature. The excitation spectrum of BaMgAl10O17:Eu2+ phosphor showed a strong peak near 336 nm (4f7 (8S)→5d1(t2g) transition) with a staircase like structure in the region 376-400 nm owing to crystal field splitting of the Eu2+ d-orbital. The 336 nm excitation produced a broad blue emission at 450 nm corresponding to 4f65d→4f7 transition. PL studies reveal the two emission centers one at 450 nm and the other at 490 nm in this phosphor.  相似文献   

8.
The electrodynamic method is used to measure the hysteresis losses of a dense assembly of magnetite nanoparticles with an average diameter D=25 nm in the frequency range f=10–150 kHz and for magnetic field amplitudes H0=100–300 Oe. It is found that the specific loss power is determined by a demagnetizing factor of a whole sample. It diminishes approximately 4.5 times when the sample aspect ratio decreases from L/d=11.4 to L/d≈1, where L and d are the sample length and diameter, respectively. For H0≤300 Oe the maximal specific loss power 120 W/g is obtained for the sample with L/d=11.4 at f=120 kHz. For comparison, the assembly specific absorption rate has been determined also by means of direct measurement of the temperature difference between the inner and outer surfaces of a flat cuvette containing magnetic nanoparticles. For both methods of measurement close values for the specific absorption rate are obtained for samples with similar demagnetizing factors.  相似文献   

9.
During ultrasound-induced cavitation in liquids, acoustic emissions at fundamental and harmonic frequencies can be detected. The effect of acoustic emissions at harmonic frequencies on the sonochemical and sonophysical activities has not been explored, especially in large-scale sonoreactors. In this study, the acoustic emissions in the range, 0-250 kHz in a 36 kHz sonoreactor with varying liquid heights were studied and compared with the sonochemical activities. The acoustic pressures at both fundamental and harmonics decreased drastically as the liquid height was increased due to the attenuation of sound energy. It was observed that the increase in input power resulted in only an increase in the acoustic emissions at derivative frequencies such as, harmonics and subharmonics. The sonochemical activity, evaluated in terms of sonochemiluminescence and H2O2 yield, was not significantly enhanced at higher input power levels. This suggests that at higher power levels, the “extra” acoustic energy is not effectively used to generate primary cavitation activity; rather it is converted to generate acoustic emissions at harmonic and subharmonic frequencies. This is an important observation for the design of energy efficiency large-scale sonochemical reactors.  相似文献   

10.
Femtosecond pulsed laser ablation (τ = 120 fs, λ = 800 nm, repetition rate = 1 kHz) of thin diamond-like carbon (DLC) films on silicon was conducted in air using a direct focusing technique for estimating ablation threshold and investigating the influence of ablation parameter on the morphological features of ablated regions. The single-pulse ablation threshold estimated by two different methods were ?th(1) = 2.43 and 2.51 J/cm2. The morphological changes were evaluated by means of scanning electron microscopy. A comparison with picosecond pulsed laser ablation shows lower threshold and reduced collateral thermal damage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号