首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 125 毫秒
1.
介绍了中能X光机装置触发系统研制和相关实验结果,触发系统包括主机6个支路激光开关的触发和主机放电的触发。其中6个支路的触发由6台YAG四倍频激光器完成,主机放电电触发系统由1台YAG四倍频激光器来触发。实验结果表明:每台激光器出光时间抖动σ小于等于0.3 ns,激光开关导通延迟时间约25 ns,抖动σ小于等于1.2 ns,电触发系统中激光与触发器输出电压之间的时间抖动σ为0.5 ns,匹配负载上电压大于120 kV,前沿约28 ns,脉宽150 ns。中能X光机在杆箍缩二极管负载上获得最大输出为4.2 MV/100 kA的电脉冲,电压脉冲半高宽约55 ns,输出的X射线时间抖动σ为3.4 ns。实验结果表明触发系统具备对6个支路精确调节和控制的能力,确保了中能X光机装置的高可靠性。  相似文献   

2.
 建立了精确的激光触发沿面闪络试验系统,用波长1 064/532 nm,调Q开关的Nd:YAG固体激光器来触发绝缘试品的沿面闪络。分别测量了Marx发生器的触发器输入电压和输出电压、Marx发生器的触发脉冲和Marx发生器输出电压、激光器的Q开关控制信号和输出激光脉冲之间的时延和抖动。应用自制的数字脉冲发生器控制Marx发生器的触发器及激光器的氙灯信号触发,用Marx发生器输出电压控制激光器的Q开关;根据所测时延和激光器的控制时序,调整数字脉冲发生器各通道的时延。实验结果显示:Marx输出电压与激光脉冲时延516.1 ns,抖动4.5 ns,达到激光脉冲与脉冲电压的精确同步。  相似文献   

3.
何安  丁瑜  康军军  任济  王贵林  张朝辉  夏明鹤  计策 《强激光与粒子束》2018,30(3):035003-1-035003-5
介绍了Z箍缩初级实验平台“聚龙一号”装置24路模块的精确控制技术和实验结果, 通过采用24个激光触发开关来控制24路模块的精确导通, 实现了对“聚龙一号”装置输出电流波形的精确控制和调节。24个激光触发开关由12台Nd: YAG四倍频脉冲激光器来触发, 每台激光器分光后触发2路激光开关。实验结果表明: 24路激光之间的抖动小于1.0 ns, 激光开关的抖动小于1.5 ns,“聚龙一号”装置在主Marx充电电压为65 kV时, 当24路模块同步导通时,获得负载电流9.8 MA, 电流前沿上升时间(10%~90%)为75 ns;在24路模块分时放电时,实现了对电流波形的精确调节,电流前沿上升时间(10%~90%)可以拓展到600 ns, 对应的负载电流峰值为5.5 MA,电流波形的模拟值与实验测量结果基本一致,在相同负载和实验条件下,获得的电流波形具有很好的重复性。  相似文献   

4.
电子束泵浦KrF激光MOPA系统的同步控制   总被引:2,自引:1,他引:1       下载免费PDF全文
 介绍研究出的MOPA系统完整的同步控制时间关联逻辑、各单元启动方式及同步系统的硬件。由Fe-Nb-Cu超微晶薄膜材料做成的同轴单匝磁开关及脉冲变压器产生大约150kV、上升时间小于200ns的高压,触发MOPA系统中的Marx发生器,当火花隙欠压比为90%时,Marx发生器中电压建立的时间抖动分别小于13ns和23ns。采用激光触发主开关时,泵浦功率系统总体抖动时间小于10ns,保证了整个电子束泵浦KrF激光MOPA系统的正常运行。  相似文献   

5.
冷阴极闸流管的同步特性   总被引:1,自引:1,他引:0       下载免费PDF全文
对TPI1-10k/50型冷阴极闸流管应用的同步特性开展了研究,通过对闸流管触发参数包括储氢加热电压、直流预电离电流、辅助触发脉冲电流、以及主触发脉冲电流的实验研究,实现了该闸流管在工作电压40 kV、工作电流16 kA、脉冲宽度200 ns、重复频率20 Hz条件下,延时抖动约2 ns。另外通过实验研究发现,通过调节触发参数,可以实现开关延时的调节,达到40 ns范围内精确到±1 ns。  相似文献   

6.
介绍了4支路并联快前沿直线脉冲变压器驱动源(FLTD)模块的初步实验结果,在工作电压160 kV时,次级短路放电电流幅值达到103.4 kA,电流前沿为78 ns(10%~90%)。利用微分环测量了4只开关在工作电压120 kV时的同步情况,研究分析了开关同步对放电电流幅值和波形的影响。开关同步小于15ns时,放电电流幅值变化不明显,电流幅值的标准偏差约3.62 kA,电流波形没有明显畸变;开关同步15~25ns时,放电电流幅值略有下降,电流幅值的标准偏差约8.59 kA,电流波形有一定程度畸变;开关同步大于25ns时,放电电流幅值明显降低,电流的标准偏差显著增大,电流波形发生严重畸变。  相似文献   

7.
Marx发生器建立时间及抖动实验研究   总被引:5,自引:4,他引:1       下载免费PDF全文
 Marx发生器建立时间及抖动与Marx发生器中球隙开关的工作状态有关,同时与开关的触发电压幅值及极性有关。通过实验获得了Marx发生器建立时间及抖动最小时最佳工作状态的相关参数。天光一号电子束加速器从同步机发出指令信号至主Marx输出,总的延时及抖动为(1629±8.4)ns,满足MOPA系统建立时间抖动小于20ns的要求。  相似文献   

8.
开关抖动对直线变压器驱动源波形叠加的影响   总被引:1,自引:1,他引:0       下载免费PDF全文
以正态分布作为开关延时的数学模型,讨论了多路开关同步工作时,开关抖动、单路输出波形前沿对直线变压器驱动源多路波形叠加的影响。模拟研究结果表明:开关抖动对输出波形前沿的影响与单路输出波形的质量有关,单路波形前沿越小,开关抖动对感应叠加后输出波形前沿影响越明显。考虑4路同步工作的开关抖动为5 ns,单路波形前沿由10 ns增大到80 ns,感应叠加后输出波形前沿平均增量由6.7 ns减小为1.7 ns,因此当单路输出波形前沿较大时追求开关抖动小的意义不大。  相似文献   

9.
叶明天  王真  龙天骏  周林  李正宏 《强激光与粒子束》2022,34(9):095009-1-095009-4
为研究电脉冲触发真空沿面闪络开关在中、小通流条件下的适用性,基于直接镀铜基板工艺制作了真空沿面闪络开关样件并搭建了开关工作特性测试实验平台。通过实验手段初步研究了开关耐压特性、触发工作特性(触发延时、抖动、工作范围)和寿命特性。实验结果表明:有效间隙7.2 mm的真空沿面闪络开关直流耐压约40 kV;开关在18 kV工作电压下触发导通延时89.9 ns,抖动13.1 ns,开关在1~18 kV工作电压范围内均能可靠触发导通;连续考核约2300次后开关各项特性无明显变化。  相似文献   

10.
 DPF-300脉冲X射线源的同步触发系统采用三级触发:第一级由初级脉冲产生器触发氢闸流管;第二级由氢闸流管输出脉冲触发多路触发开关;第三级由多路触发开关和触发箱组成,触发主放电场畸变开关。该触发系统中多路触发开关产生负极性脉冲信号,通过耦合电容,到达开关的触发脉冲上升沿,约为40 ns,脉冲半高宽约60 ns,上升陡度大于0.67 kV/ns。能够同时触发40个同轴型场畸变开关,电压工作范围20~40 kV,不同发次触发箱输出的触发脉冲信号时间分散性小于4 ns,同一发次不同开关的放电时间分散性小于20 ns。在工作电压20 kV,主放电开关充0.115 MPa氮气时,整机负载电流达到约1 MA。  相似文献   

11.
One kind of instantaneous electron beam emittance measurement system based on the optical transition radiation principle and double imaging optical method has been set up. It is mainly adopted in the test for the intense electron-beam produced by a linear induction accelerator. The system features two characteristics. The first one concerns the system synchronization signal triggered by the following edge of the main output waveform from a Blumlein switch. The synchronous precision of about 1 ns between the electron beam and the image capture time can be reached in this way so that the electron beam emittance at the desired time point can be obtained. The other advantage of the system is the ability to obtain the beam spot and beam divergence in one measurement so that the calculated result is the true beam emittance at that time, which can explain the electron beam condition. It provides to be a powerful beam diagnostic method for a 2.5 kA, 18.5 MeV, 90 ns (FWHM) electron beam pulse produced by Dragon I. The ability of the instantaneous measurement is about 3 ns and it can measure the beam emittance at any time point during one beam pulse. A series of beam emittances have been obtained for Dragon I. The typical beam spot is 9.0 mm (FWHM) in diameter and the corresponding beam divergence is about 10.5 mrad.  相似文献   

12.
 针对在阳加速器上进行Z箍缩实验时存在的同步精度低的问题,研究了一套同步触发信号取自加速器输出电流的技术。利用加速器工作电流波形与物理实验现象间的固有延迟时间关系来判断同步的时刻,时间关联的精度可到达ns量级。为了防止加速器对测量系统的影响,根据延迟时间长短的不同情况还研究了光电隔离方式和光纤传输方式,解决了在阳加速器平台上的电磁干扰问题,实现了在阳加速器上进行可靠物理实验的精密测量工作;本触发方式配合高速分幅相机的应用,稳定而可靠地以10 ns间隔、3 ns曝光时间拍摄到了Z箍缩的发展过程。  相似文献   

13.
桂淮濛  施卫 《物理学报》2018,67(18):184207-184207
针对线性模式下GaAs光电导开关时间抖动特性的研究,对提高精密同步控制系统的输出性能具有重要意义.根据电脉冲的概率分布和时间与电脉冲波形的对应关系,结合载流子的输运过程,对光电导开关时间抖动进行了定性的理论推导.此外,通过搭建实验平台,利用正交光栅分光,将一束激光同时触发两路并联的GaAs光电导开关,改变触发激光脉冲宽度及外加偏置电压测试开关时间抖动,根据实验值的对比分析,得出在不同的外加偏置电压下,随着触发激光脉冲宽度的减小,开关时间抖动值随之减小.验证了触发激光脉冲宽度对开关时间抖动的影响及理论分析的正确性.研究结果对GaAs光电导开关时间抖动的进一步减小具有一定的指导意义.  相似文献   

14.
强流电子束二极管等离子体光学诊断   总被引:1,自引:1,他引:0       下载免费PDF全文
通过处理强流电子束加速器主开关导通之后所形成的高压电脉冲,得到了二极管等离子体光学诊断的同步时间基准。采用高压电脉冲延时结合二极管等离子体光信号延时的方案,实现了相机曝光过程与等离子体发光过程的ns级精度同步。综合采取屏蔽、滤波等措施,实现了整个系统的电磁兼容,最终稳定地拍摄到了ns时间分辨的二极管等离子体发光过程。  相似文献   

15.
周亮  张明  孙承革 《强激光与粒子束》2020,32(3):035001-1-035001-6
通过等离子体建模仿真及物理实验结合的方式验证了激光触发伪火花开关的可行性。分别使用波长266 nm和532 nm的激光,对激光触发伪火花开关的最低激光触发能量、阳极着火延迟时间和时间跳动三项参数进行测试。在非聚焦模式下,仅调整激光能量,测得开关在波长266 nm激光触发下,最低触发能量为15 mJ,该触发能量下,阳极着火延迟时间约为340 ns,时间跳动约为40 ns;在波长532 nm激光触发下,最低触发能量为83 mJ,该触发能量下,阳极着火延迟时间约为420 ns,时间跳动约为60 ns。在维持实验平台不变的情况下,仅对入射激光进行聚焦,测得波长266 nm激光触发下,最低触发能量为4 mJ,当触发能量8 mJ时,阳极着火延迟时间190 ns,开关时间跳动小于1 ns;波长532 nm激光触发下,最低触发能量为6 mJ,当激光触发能量为8 mJ时,阳极着火延迟时间240 ns,开关时间跳动小于1 ns。  相似文献   

16.
神龙二号是一台三脉冲强流脉冲电子束直线感应加速器,就其多脉冲的电子束束参数的测量而言,基本要求是单个脉冲可分辨,进一步的要求是脉冲内时间可分辨。基于光学渡越辐射原理及瞬态发射度测量系统原理,发展了一种束斑与发散角可以分开测量的光学布局结构,结合多台高速分幅相机,成功研制了一套完整的多脉冲电子束束参数的测量系统,其特点是灵活的组合测量方式,全面满足了神龙二号复杂艰难的调试及参数测量工作要求。测量系统最高时间分辨测量能力达到约2 ns的水平,单个脉冲可以获得至少8个时间分辨的束参数测量结果。  相似文献   

17.
 介绍了一种低抖动、快前沿高电压重复率触发器,输出参数为:重复率可达100 pulse/s,输出时延约225 ns,抖动约1 ns,前沿约26 ns,脉宽约70 ns,高阻负载上电脉冲的峰值可达-40 kV,重复率为50 pulse/s时,峰值可达-51 kV,单次工作时的峰值可达-60 kV。该触发器主要由控制单元、高压供电单元与脉冲形成单元构成,脉冲形成单元采用了低电感电容对负载快放电的结构,建立开关为氢闸流管。实验发现,氢闸流管存在微导通状态,开关的通道电阻及维持的时间与开关极间的电势差有关;电势差越高,通道电阻越小,微导通状态维持的时间越长。此外,氢闸流管的导通性能受灯丝加热电源的影响明显,当加热电压较低时,氢闸流管导通缓慢,延时与抖动较大,当加热电压过高时,氢闸流管易于发生自击穿。  相似文献   

18.
 在强流直线感应加速器中,电子束质心位置的控制是一项重要技术,要达到较好的控制效果,前提是对电子束质心位置进行准确的测量和定位。针对具有时间分辨的电子束质心位置的测量和确定,介绍了测量实验系统的建立和数据处理两个方面的研究工作。该处理方法在实际应用时能够将电子束质心位置的误差控制在1~2个像素内。用高速分幅相机以10 ns的时间间隔、3 ns的曝光时间获得了神龙一号加速器在漂移段出口处的电子束质心运动情况。结果表明:束的质心主要在半径为0.5 mm的区域内运动,束斑直径dFWHM值分别为8.4,8.8,8.5,9.3和7.6 mm,测量结果可以为束的调控提供准确参数。  相似文献   