首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
采用原子滤光器的新型激光信标方案研究   总被引:8,自引:1,他引:7  
段明浩  孔建坤  汤俊雄 《光学学报》1997,17(10):362-1367
提出了采用法拉第反常色散滤光器(FADOF)的光电双反馈激光信标新方案。该方案通过数字控制系统和光反馈系统的共同作用,使激光信标系统的稳定性、抗干扰性和可靠性大大提高,并实现了上电自动工作。这种新型激光信标的频率稳定度优于5×10-9,在30ms内可将半导体激光频率稳定在法拉第反常色散滤光器任一透射峰上。该方案可与采用法拉第反常色散滤光器的新型跟瞄系统匹配使用,对建立卫星激光通信链路有重要意义。  相似文献   

2.
强磁场中Rb D2线法拉第反常色散滤光器特性研究   总被引:3,自引:2,他引:1  
彭玉峰  胡志林 《光学学报》1993,13(5):19-424
报道强磁场中RbD_2线反常色散光学滤波器的理论模型与实验研究,讨论了强磁场中RbD-2线法拉第反常色散秀射谱及其磁场,温度调谐特性.  相似文献   

3.
吴学健  尉昊赟  朱敏昊  张继涛  李岩 《物理学报》2012,61(18):180601-180601
利用光纤飞秒光频梳和外腔可调谐半导体激光器, 建立了一套双频He-Ne激光器频率测量系统. 选用铷钟作为系统的频率基准, 通过将外腔半导体激光锁定至光频梳使得其频率溯源至铷钟, 再利用外腔可调谐半导体激光与双频He-Ne激光器输出的正交偏振激光拍频, 同时测量两路正交偏振激光频率. 将可调谐半导体激光器锁定至光频梳第1894449个梳齿, 其绝对频率为473612190000.0±2.7 kHz, 相对不确定度为5.7×10-12. 对商品双频He-Ne激光器进行频率测量实验, 双频He-Ne激光器水平方向偏振激光频率均值为473612229934 kHz, 竖直方向偏振激光频率均值为473612232111 kHz, 平均时间为1024 s的相对Allan标准差为5.2×10-11, 频差均值为2.177 MHz, 标准偏差为2 kHz.  相似文献   

4.
原子稳频半导体激光器的微处理器智能控制   总被引:1,自引:0,他引:1  
在Cs原子法拉第反常色散滤光器(FADOF)光反馈半导体稳频激光器的基础上,引入以微处理器为核心的数字补偿控制技术,对稳频半导体激光器的工作实行智能化控制,大大提高了原子稳频半导体激光器的稳定性、可靠性和抗干扰能力,使之更具有实用价值。  相似文献   

5.
在采用磁光阱实现单个铯原子俘获的实验中, 运用无调制偏振光谱方法将光栅外腔半导体激光器(提供冷却/俘获光)的频率锁定在铯原子6S1/2 F=4→6P3/2 F′=5的超精细跃迁线上.采用偏振光谱技术得到的类色散曲线作为鉴频信号, 并同时对光栅外腔半导体激光器的电流调制端口和光栅外腔的压电陶瓷电压调制端口进行反馈, 以拓展反馈环路的带宽, 实现激光器的频率锁定.与通常的饱和吸收光谱稳频技术相比, 激光频率锁定之后的频率稳定度得到了明显改善.在取样时间τ=300 s时, 阿仑方差σy(τ)=4.6×10-12.  相似文献   

6.
将频率调制加在声光调制器上 ,用三次谐波探测法获得了铯原子D2 线的三阶微分饱和光谱。采用这种激光器无调制扰动方案结合三次谐波锁频技术 ,实现了 85 2nm的分布布拉格反射器半导体激光器相对于 6S1/2 F =4- 6P3 /2 F′ =5超精细跃线的频率锁定。由锁定后的频率误差信号估算 ,10s内激光频率起伏小于± 35 0kHz ,相对频率稳定度约 1× 10 -9。这种无调制扰动方案可以消除一般的饱和吸收稳频方法中由于直接对激光器进行频率调制而带来的额外频率噪声 ;三次谐波锁频技术的应用 ,还可有效地降低铯原子饱和吸收谱中剩余多普勒背景的影响  相似文献   

7.
声光偏频亚多普勒光谱无调制激光频率锁定   总被引:9,自引:2,他引:7  
将激光器锁定到合适的参考频率标准上 ,可以有效地改善激光器的频率稳定性。采用两个声光调制器(AOM) ,使铯原子D2 线饱和吸收光谱分别发生Ω±Δ绝对频移 ;通过改变射频压控振荡器 (RFVCO)的Vf 端口直流电压调节相对频移间隔Δ ,当相对频率间隔选择合适时两信号相减得到了类色散型鉴频曲线。实验中实现了85 2nm光栅外腔半导体激光器相对于铯原子D2 线6S1/2 F =4 6P3 /2 F′ =5超精细跃迁线 (中心频率ν0 )的无调制偏频锁定 (锁定后中心频率ν0 +Ω ,偏频量为Ω)。由闭环锁定后的误差信号估计 ,5 0s内典型的频率起伏小于± 2 70kHz ,较相同时间段内激光器自由运转时的频率起伏 14MHz有显著的改善。该方法可避免对激光器直接进行频率调制的常规饱和吸收锁频方案所引入的额外频率噪声和强度噪声。  相似文献   

8.
张继涛  吴学健  李岩  尉昊赟 《物理学报》2012,61(10):100601-100601
提出一种利用光频梳和可调谐半导体激光器提高台阶高度测量准确度的方法. 通过将可调谐激光器锁定至光频梳,可对激光器的输出波长进行精确锁定与测量.基于可调合成波长链原理,利用锁定后的半导体激光器构建了一套台阶高度测量方案,该方案可消除合成波长误差对台阶高度测量不确定度的影响. 采用一台可调谐半导体激光器和光频梳进行了5000 s的连续锁定实验, 结果表明,锁定后的可调谐半导体激光器的频率稳定度达 1.8×10-12.该方法的理论测量不确定度约为7.9 nm, 且测量结果可溯源至时间频率基准.  相似文献   

9.
对工作在铷5P1/2→10S1/2(532 nm)跃迁的法拉第反常色散滤光器的传输特性,并对中间场下激发态法拉第反常色散滤光器的理论模型进行了分析与讨论.依据量子力学微扰理论和量子跃迁理论,给予了完整地描述.理论分析结果表明,在气室温度434 K,磁场强度0.067 T,抽运光强度20 W/m2,气室长度0.1 m条件下,法拉第反常色散滤光器处于一个最佳工作状态;期望的线芯工作方式得以实现.中心透射峰适宜作滤光器的信号光通道.理论模型预测滤光器的峰值透过率接近50%,等效带宽仅为2.6 GHz.铷532 nm激发态法拉第反常色散滤光器的光谱特性可用于检测具有重要应用价值的二倍频Nd:YAG激光信号.  相似文献   

10.
掌蕴东  贾晓玲  毕勇  王骐  马祖光 《光学学报》2001,21(11):377-1380
从理论和实验两个方面对强度磁场中钾D2线法拉第反常色散滤波器的特性进行了研究,在不同工作条件下,获得线芯和线翼两种方式的法拉第反常色散滤波器,并讨论了温度对其滤波特性的影响。  相似文献   

11.
从理论和模拟两方面研究了西安质子应用装置二极铁、四极铁电源电流纹波对引出束流的影响,并根据模拟结果确定出以下单种磁铁电源电流纹波标准:对于聚焦四极铁电源,电流纹波/设定值应小于1.2×10-4;对于散焦四极铁电源,电流纹波/设定值应小于2×10-3;对于二极铁电源,电流纹波/设定值应小于4×10-4。因西安质子应用装置同步环上所有磁铁电源采用同一纹波标准,综合考虑所有磁铁电源电流纹波后,最终确定电源电流纹波/设定值应小于1×10-4。  相似文献   

12.
基于碱性条件下过氧亚硝酸根-亚硫酸钠-荧光素化学发光新体系中过氧亚硝酸根浓度与化学发光强度呈线性关系,建立了流动注射化学发光法测定过氧亚硝酸根浓度的新方法。在优化实验条件下,方法的线性范围为2.384×10-6—1.192×10-4mol/L,r2=0.9994,最低检测浓度为2.384×10-6mol/L,平行测定11次相对标准偏差为0.36%。并将该方法与鲁米诺体系进行了对比,结果满意。  相似文献   

13.
以CdTe量子点作为荧光探针,基于荧光猝灭法对铅进行了定量检测,考察了缓冲溶液体系、量子点浓度、反应时间等多种因素的影响。实验结果表明,在pH 7.5的0.2mol/L Na2HPO4-NaH2PO4缓冲液中,反应时间为10min,铅浓度为2.0×10-6—3.5×10-5mol/L范围时,其线性回归方程为ΔF=26.35+11.47C(×10-6mol/L),相关系数和检出限分别为0.9991和1.8×10-8mol/L。该方法灵敏度高,为铅的测定提供了新的方法。  相似文献   

14.
掺铥钨酸钡单晶生长和光谱研究   总被引:1,自引:0,他引:1       下载免费PDF全文
采用Czochralski 法生长出光学质量的BaWO4:Tm3+单晶,利用X粉末衍射实验确定了不同掺杂浓度晶体的晶胞参数.测定了晶体的室温吸收光谱,应用Juud-Ofelt理论,拟合了光谱的3个强度参数,其值分别为Ω2=404×10-20cm2Ω4=0509×10-20cm2Ω关键词: 4:Tm3+单晶')" href="#">BaWO4:Tm3+单晶 吸收谱 光谱参数 上转换发光  相似文献   

15.
The physiological basis of auditory frequency selectivity was investigated by recording the temporal response patterns of single cochlear-nerve fibers in the cat. The characteristic frequency and sharpness of tuning was determined for low-frequency cochlear-nerve fibers with two-tone signals whose frequency components were of equal amplitude and starting phase. The measures were compared with those obtained with sinusoidal signals. The two-tone characteristic frequency (2TCF) is defined as the arithmetic-center frequency at which the fiber is synchronized to both signal frequencies in equal measure. The 2TCF closely corresponds to the characteristic frequency as determined by the frequency threshold curve. Moreover, the 2TCF changes relatively little (2%-12%) over a 60-dB intensity range. The 2TCF generally shifts upward with increasing intensity for cochlear-nerve fibers tuned to frequencies below 1 kHz and shifts downward as a function of intensity for units with characteristic frequencies (CF's) above 1 kHz. The shifts in the 2TCF are considerably smaller than those observed with sinusoidal signals. Filter functions were derived from the synchronization pattern to the two-tone signal by varying the frequency of one of the components over the fiber's response area while maintaining the other component at the 2TCF. The frequency selectivity of the two-tone filter function was determined by dividing the vector strength to the variable frequency signal by the vector strength to the CF tone. The filter function was measured 10 dB down from the peak (2T Q 10 dB) and compared with the Q 10 dB of the frequency threshold curve. The correlation between the two measures of frequency selectivity was 0.72. The 2T Q 10 dB does change as a function of intensity. The magnitude and direction of the change is dependent on the sharpness of tuning at low and moderate sound-pressure levels (SPL's). The selectivity of the more sharply tuned fibers (2T Q 10 dB greater than 3) diminishes at intensities above 60 dB SPL. However, the broadening of selectivity is relatively small in comparison to discharge rate-based measures of selectivity. The selectivity of the more broadly tuned units remains unchanged or improves slightly at similar intensity levels. The present data indicate that the frequency selectivity and tuning of low-frequency cochlear-nerve fibers are relatively stable over a 60-dB range of SPL's when measured in terms of their temporal discharge properties.  相似文献   

16.
为了研究声光效应中声致折射率变化情况,以超声光栅实验为基础,用CCD结合光强分析软件,分析了衍射光的强度分布;通过数值计算衍射光相对强度,比较得到了在超声场频率为10.27 MHz时,介质中的声光相位延迟Δ=1.2855 rad,声致折射率变化量Δn=3.014×10-6;进而讨论了电声换能器的机电耦合效率与超声频率的关系,给出当超声频率为10.33 MHz时,耦合效率最高,介质中折射率变化量最大;结果表明,在超声光栅实验中,引入这些测量内容,不仅能丰富实验内容,更能加深学生理解声光效应,扩展学生的知识面.  相似文献   

17.
采用抗生素治疗奶牛乳腺炎是目前普遍采用的一种方法,因此牛奶中抗生素残留问题倍受国际社会关注。寻求简便可行、灵敏度高的检测技术,以适用日趋严格的残留限量要求,保障人们安全、卫生地饮用牛奶至关重要、迫在眉睫。基于固载表面溶剂毛细流的自组装环效应,采用镁敏化美他环素荧光显微成像技术检测了北京市密云县4家养殖场生鲜乳中美他环素残留量,建立了一种检测新方法。实验表明,在pH9.99NH3-NH4Cl缓冲溶液及聚乙烯醇-124存在下,镁和美他环素能形成较强荧光的1∶1配合物,并在憎水性玻片表面形成自组装环,环直径0.93mm,环线宽26.2μm。当点样体积为0.50μL时,线性范围为2.2×10-13~3.6×10-12mol.ring-1(4.4×10-7~7.2×10-6mol.L-1),检测限(3σ)为8.8×10-14mol.ring-1(1.8×10-7mol.L-1)。应用于生鲜牛奶样品中抗生素的检测,得到了满意结果,回收率为93.8%~108%,RSD小于4.3%。  相似文献   

18.
高宪成  黄亦好 《光学学报》1993,13(3):68-271
报道用两波耦合技术测量光折变晶体钛酸钡锶(Ba_(1-x)Sr_xTiO-3,BST)的电荷传输参数φμτ在激光波长λ=515nm和光功率密度I—1W/cm~2下测得光折变响应时间为0.5sec.考虑到BST晶体吸收系数的光强相关性,修改了光栅形成率的函数变量,得到BST晶体的暗电导σ_a和电荷传输参数φμτ的拟合值分别为1.0×10~(-11)(Ωcm)~(-1)和2.8×10~(-10)cm~2/V.  相似文献   

19.
提出了一种新的采用载流导线的表面双磁光阱(MOT)方案(即双U型导线磁光阱方案)。通过改变中间U型导线中的电流大小,即可将一个双磁阱连续地合并为一个单磁阱,反之亦然。详细计算和分析了上述双U型载流导线磁光阱方案的磁场及其梯度的空间分布,研究发现当导线中的电流为600 A,z方向均匀偏置磁感应强度为-4.0×10-3 T时,双U型导线方案产生的两个磁阱中心的磁场梯度约为1.5×10-3~2.5×10-3 T/cm,结合通常制备磁光阱时所用的三维粘胶(Molasses)光束即可在基底表面附近形成一双磁光阱。理论分析表明在弱光近似下,每个磁光阱中所能俘获的85Rb原子数约为106 量级,相应的磁光阱温度约为270μK。由于双磁光阱可以独立制备,所以双U型导线方案特别适用于制备双样品磁光阱,并用于研究双原子样品的冷碰撞性质。  相似文献   

20.
以CdTe量子点作为荧光探针,基于荧光猝灭法对钴(Ⅱ)进行了定量检测,考察了缓冲溶液体系、量子点浓度、反应时间等多种因素的影响。实验结果表明,在pH8.0的0.2mol/LNa2HPO4-NaH2PO4缓冲液中,反应时间为10min,钴(Ⅱ)浓度为1.6×10-5—20×10-5mol/L范围时,其线性回归方程为F0/F=1.45+0.096Q(10-5mol/L),检出限为3×10-7mol/L。该方法检测范围宽,灵敏度高,为钴的测定提供了新的方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏