共查询到19条相似文献,搜索用时 93 毫秒
1.
2.
3.
用双计算全息图检测凹非球面 总被引:9,自引:3,他引:6
为实现对凹非球面的高精度检测,提出并设计了一种二元纯相位型双计算全息图.设计的双计算全息图由主全息和对准全息两部分组成,分别用于检测非球面和精确定位主全息.介绍了双计算全息图的工作原理及其设计方法,并给出了一个检测Φ140、F/2抛物面反射镜的双计算全息图设计实例,实验得到的均方根(RMS)误差为0.062λ.通过分析对准全息的误差,推导出主全息的条纹位置畸变误差,最后计算出其综合误差为0.06A.为验证实验结果的可靠性,将其与平面镜自准直检测结果(ERMS=0.062A)比较,结果二者吻合良好. 相似文献
4.
5.
6.
7.
8.
《中国光学与应用光学文摘》2007,(1)
O438.12007010453圆形计算全息图的设计及其参数计算=Design and pa-rameter calculation of circular computer generated holo-grams[刊,中]/齐月静(北京理工大学信息科学技术学院光电工程系.北京(100081)),王平…//北京理工大学学报.—2006,26(9).—821-823为实现非球面的高精度检测,在设计全息图时采用虚拟玻璃的概念,即用光学设计软件ZEMAX建立折射率为0的玻璃模型,实现全息片的出射波前沿非球面的法线方向入射,简化了补偿器的设计优化过程,提高了设计精度,最大光程差小于0.0007λ(λ=632.8nm)。编制了衍射面工艺参数的计算程序,利… 相似文献
9.
单光楔补偿检测法具有良好的适用性、鲁棒性和灵活性,但是在检测光路中存在多种误差耦合,误差解耦困难,影响了单光楔补偿检测的精度和可信度。针对这一问题,本文提出一种计算全息法(Computer Generation Hologram,CGH)标定单光楔补偿检测光路系统误差的新方法。文中首先分析了单光楔补偿检测法系统误差的来源,并对CGH标定光楔补偿器的可行性进行了分析。结合工程实例,对口径为150 mm的单光楔补偿器设计了CGH,经分析可得CGH的标定精度为1.98 nm RMS,CGH标定后单光楔补偿检测精度为3.43 nm RMS,该精度能够满足大口径凸非球面反射镜的高精度检测要求。结果表明:CGH可以准确标定单光楔补偿器的位姿和检测光路的系统误差,解决了检测光路中误差解耦困难的问题,提高了单光楔补偿检测的准确性和可靠性。使用CGH标定得到Tap#2和Tap#3的检测光路系统误差分别为0.023λRMS和0.011λRMS。 相似文献
10.
平场全息凹面光栅制作结构与使用结构之间误差补偿作用的数值模拟与实验验证 总被引:1,自引:0,他引:1
通过对优化计算出的平场全息凹面光栅制作结构(曝光记录结构)和使用结构(光谱仪分光结构)之间各个参数进行联合数值模拟,得出如下结论:在优化设计参数值附近一个较大范围的误差区域内,平场全息凹面光栅的制作结构参数误差和使用结构参数误差可以相互补偿,最终补偿的结果可以使光谱成像质量达到与原设计结构相当的水平,满足光谱仪器的使用要求。文章给出了数值模拟结果以及与其相符的实验验证结果。此补偿作用有利于降低平场全息凹面光栅制作中各个参数精度的调节难度,并且可以对实际使用过程中光谱仪器的设计和装调进行理论上的指导。 相似文献
11.
本文研究二值干涉型计算全息图,这种全息图最适于综合位相型波前,因此本文的讨论也只限于位相型波前的情况,对物光和参考光的选择以及全息图的抽样进行了分析,并得出相应的结论。 相似文献
12.
13.
提出一种新的基于信息光学的数字水印方法。该方法将水印信息隐藏于半色调编码的计算全息图之中。通过相位复原技术将需隐藏的水印信息编码为相位函数嵌入在复波前中,其振幅定义为宿主图像,通过计算全息记录复波前并对全息图进行半色调编码完成水印信息的嵌入。水印的提取过程只需对含有水印信息的半色调图像进行光学或数字的傅里叶变换即可完成。并给出了算法有效性的理论分析和仿真实验结果。结果证明这种水印技术对于各种数字图像处理操作具有很高的稳健性,且半色调编码图的二值特性使嵌入水印具有很强的抗打印、抗复印、抗扫描的能力。 相似文献
14.
Rahul Bhatt Sanjay K. Mishra D. Mohan A.K. Gupta 《Optics and Lasers in Engineering》2008,46(6):428-439
A fast holographic wavefront sensor is proposed using a computer-generated hologram (CGH). This CGH is a multiplexed hologram of different Zernike mode–amplitude combinations, and is designed in such a manner as to get the corresponding spots on the detector according to the presence and strength of a particular aberration. Interference between the aberrated wavefront (with a single mode–amplitude combination) and the Fourier transform of an image with single bright pixel (defined as dot image) is numerically calculated for one hologram. Different mode–amplitude combination and corresponding different positions of bright pixels (dots) are taken to compute various holograms and then all the holograms are multiplexed to get the final hologram. When the aberrated wavefront with a particular mode–amplitude combination is incident onto the multiplexed hologram, the corresponding dot is generated in the Fourier plane. A lens performs the Fourier transform in optical domain and provides the instant detection of amplitude of the respective Zernike mode. The main advantage of the scheme is to avoid the need of any computations, which makes it really fast. The simulation results are presented with the cross-talk analysis for few Zernike terms. 相似文献
15.
M.M. Talha Jun Chang Yongtian Wang Dewen Cheng Tingcheng Zhang M. Aslam A. Naeem Khan 《Optik》2010,121(24):2262-2265
A computer-generated hologram (CGH) null compensator has been designed for optical metrology of a freeform surface (FFS) with positive base radius. The CGH is being employed in the freeform testing for the first time. The basic concept of the optical metrology and the testing procedure are explained explicitly. The design results of the CGH null compensator are presented in this article. Moreover, the design method and its results are discussed in detail. 相似文献
16.
17.
18.
Shack-Hartmann波前传感器非零位在轴检测离轴非球面反射镜 总被引:1,自引:0,他引:1
在离轴非球面反射镜研磨后期和粗抛光阶段,被测反射镜面形与理想面形存在着较大的偏差,表面反射率较低,采用干涉测量会因局部区域干涉条纹过密或条纹对比度过低,造成普通干涉仪无法进行全口径测量,而普通接触式轮廓仪测量精度此时已经不能满足加工要求。鉴于Shack-Hartmann波前传感器较大的动态范围和较高的测量精度,提出了采用Shack-Hartmann波前传感器非零位在轴检测离轴非球面面形,研究了该方法的检测原理并搭建了检测系统,分析了系统误差来源,并制作了用于在轴检测离轴非球面的参考波前,对两个不同加工精度的离轴非球面反射镜进行了测量,并与干涉仪的测量结果进行了对比。对比结果表明,Shack-Hartmann波前传感器的测量结果是正确可靠的,并且可以弥补轮廓仪测量和干涉仪测量的不足,从而证明了采用Shack-Hartmann波前传感器在轴检测离轴非球面的可行性和正确性。 相似文献