首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 125 毫秒
1.
The up-take of Gd(III) complexes of BOPTA, DTPA, DOTA, EDTP, HPDO3A, and DOTP in HRBC has been evaluated by measuring the lanthanide induced shift (LIS) produced by the corresponding dysprosium complexes (DC) on the MAS-NMR resonances of water protons and free sodium ions. These complexes are important in their use as MRI contrast agents (MRI-CA) in diagnostics. 1H and 23Na MAS-NMR spectra of HRBC suspension, collected at 9.395T, show only one signal due to extra- and intra-cellular water (or sodium). In MAS spectra, the presence of DC in a cellular compartment produces the LIS of only the nuclei (water proton or sodium) in that cellular compartment and this LIS can be related to the DC concentrations (by the experimental curves of LIS vs. DC concentrations) collected in the physiological solution. To obtain correct results about LIS, the use of MAS technique is mandatory, because it guarantees the only the nuclei staying in the same cellular compartment where the LC is present show the LIS. In all the cases considered, the addition of the DC to HRBC (100% hematocrit) produced a shift of only the extra-cellular water (or sodium) signal and the gradient of concentration (GC) between extra- and intra-cellular compartments resulted greater than 100:1, when calculated by means of sodium signals. These high values of GC are direct proofs that none of the tested dysprosium complexes crosses the HRBC membrane. Since the DC are iso-structural to the gadolinium complexes the corresponding gadolinium ones (MRI-CA) do not cross the HRBC membrane and, consequently, they are not up-taken in HRBC. The GC values calculated by means of water proton signals resulted much lower than those obtained by sodium signals. This proves that the choice of the isotope is a crucial step in order to use this method in the best way. In fact, GC value depends on the lowest detectable LIS which, in turn, depends on the nature of the LC (lanthanide complex) and the observed isotopes.  相似文献   

2.
NMR signals from samples that rotate uniformly about the central conductor of a TCD (toroid cavity detector) exhibit frequency shifts that are directly proportional to the sample's angular velocity. This newly observed effect is based on the unique radiofrequency field inside TCDs, which is variable in direction. If a liquid sample is pumped through a capillary tube wound about the central conductor, the frequency shift is proportional to the flow rate. A mathematical relationship between a volumetric flow rate and the frequency shift is established and experimentally verified to high precision. Additionally, two-dimensional flow-resolved NMR spectroscopy for discrimination between components with different flow velocities yet retaining chemical shift information for structural analysis is presented. The application of the two-dimensional method in chromatographic NMR is suggested. Furthermore, utilization of the frequency-shift effect for rheologic studies if combined with toroid-cavity rotating-frame imaging is proposed.  相似文献   

3.
The paramagnetic metallocenes and decamethylmetallocenes (C(5)H(5))(2)M and (C(5)Me(5))(2)M with M=V (S=3/2), Mn (S=5/2 or 1/2), Co (S=1/2), and Ni (S=1) were studied by (1)H and (13)C solid-state MAS NMR spectroscopy. Near room temperature spinning sideband manifolds cover ranges of up to 1100 and 3500 ppm, and isotropic signal shifts appear between -260 and 300 ppm and between -600 and 1640 ppm for (1)H and (13)C NMR spectra, respectively. The isotropic paramagnetic signal shifts, which are related to the spin densities in the s orbital of ligand atoms, were discussed. A Herzfeld--Berger spinning sideband analysis of the ring carbon signals yielded the principal values of the paramagnetic shift tensors, and for metallocenes with a small g-factor anisotropy the electron spin density in the ligand pi system was determined from the chemical shift anisotropy. The unusual features of the (1)H and (13)C solid-state NMR spectra of manganocene were related to its chain structure while temperature-dependent (1)H MAS NMR studies reflected antiferromagnetic interaction between the spin centers.  相似文献   

4.
Free induction decay (FID) signals in solid state NMR measurements performed with magic angle spinning can often be extended in time by factors on the order of 10 by a simple pulsed spin locking technique. The sensitivity of a structural measurement in which the structural information is contained in the dependence of the integrated FID amplitude on a preceding evolution period can therefore be enhanced substantially by pulsed spin locking in the signal detection period. We demonstrate sensitivity enhancements in a variety of solid state NMR techniques that are applicable to selectively isotopically labeled samples, including 13C-15N rotational echo double resonance (REDOR), 13C-13C dipolar recoupling measurements using the constant-time finite-pulse radio-frequency-driven recoupling (fpRFDR-CT) and constant-time double-quantum-filtered dipolar recoupling (CTDQFD) techniques, and torsion angle measurements using the double quantum chemical shift anisotropy (DQCSA) technique. Further, we demonstrate that the structural information in the solid state NMR data is not distorted by pulsed spin locking in the detection period.  相似文献   

5.
In this study, a 267-microm-diameter solenoid transceiver is used to acquire localized (1)H NMR spectra and the measured signal-to-noise ratio (SNR) at 500 MHz is shown to be within 20--30% of theoretical limits formulated by considering only its resistive losses. This is illustrated using a 100-microm-diameter globule of triacylglycerols (approximately 900mM) that may be an oocyte precursor in young Xenopus laevis frogs and a water sample containing choline at a concentration often found in live mammalian cells (approximately 33 mM). In chemical shift imaging (CSI) experiments performed using a few thousand total scans, the choline methyl line is shown to have an acceptable SNR in resolved volume elements containing only 50 pL of sample, and localized spectra are resolved from just 5 pL in the Xenopus globule. These findings demonstrate the feasibility of performing (1)H NMR on picoliter-scale sample volumes in biological cells and tissues and illustrate how the achieved SNR in spectroscopic images can be predicted with reasonable accuracy at microscopic spatial resolutions.  相似文献   

6.
A subspace time-domain algorithm for automated NMR spectral normalization   总被引:2,自引:0,他引:2  
Recently, two methods have been proposed for quantitatively comparing NMR spectra of control and treated samples, in order to examine the possible occurring variations in cell metabolism and/or structure in response to numerous physical, chemical, and biological agents. These methods are the maximum superposition normalization algorithm (MaSNAl) and the minimum rank normalization algorithm (MiRaNAl). In this paper a new subspace-based time-domain normalization algorithm, denoted by SuTdNAl (subspace time-domain normalization algorithm), is presented. By the determination of the intersection of the column spaces of two Hankel matrices, the common signal poles and further on the components having proportionally varying amplitudes are detected. The method has the advantage that it is computationally less intensive than the MaSNAl and the MiRaNAl. Furthermore, no approximate estimate of the normalization factor is required. The algorithm was tested by Monte Carlo simulations on a set of simulation signals. It was shown that the SuTdNAl has a statistical performance similar to that of the MiRaNAl, which itself is an improvement over the MaSNAl. Furthermore, two samples of known contents are compared with the MiRaNAl, the SuTdNAl, and an older method using a standard. Finally, the SuTdNAl is tested on a realistic simulation example derived from an in vitro measurement on cells.  相似文献   

7.
Kaolin clay samples were mixed with various amounts of Fe2O3 powder. The influence of this magnetic impurity on NMR relaxation and diffusion measurements on the water in this porous material was investigated. The NMR relaxation measurements showed a nearly mono-exponential decay, leading to the conclusion that the pore size distribution of the clay samples is either narrow and/or that the pores are interconnected very well. Both the longitudinal and the transverse relaxation rate depend linearly on the concentration of the Fe2O3 impurity. The NMR diffusion measurements revealed that the Fe2O3 causes internal magnetic field gradients that largely exceed the maximum external gradient that could be applied by our NMR apparatus (0.3 T/m). Additional SQUID measurements yielded the magnetization and magnetic susceptibility of the samples at the magnetic field strength used in the NMR measurements (0.8 T). A theoretical estimate of the internal magnetic field gradients leads to the conclusion that the water in the porous clay samples cannot be described by the commonly observed motional averaging regime. Probably an intermediate or a localization regime is induced by the large internal gradients, which are estimated to be on the order of 1 to 10 T/m in the pore volume and may exceed 1000 T/m at the pore surface.  相似文献   

8.
We describe imaging experiments in which the pattern of the dipolar field generated by spatially modulated nuclear magnetization is directly visualized in simply structured phantoms. Two types of experiment have been carried out at 11.7 T using (1)H NMR signals. In the first, the field from a single spin species is imaged via its own NMR signal. In the second, the NMR signal from one spin species is used to image the field generated by a second species. The field patterns measured in these experiments correspond well with those calculated using simple theoretical expressions for the dipolar field. The results also directly demonstrate the spatial sensitivity of the signal generated using dipolar field effects, indicating that the range of the field depends upon the inverse of the spatial frequency with which the magnetization is modulated.  相似文献   

9.
A stray field (STRAFI) module has been added to the GAMMA magnetic resonance simulation platform in order to facilitate computational investigations of NMR experiments in large static field gradients that are on the order of 50 T/m. The package has been used to examine system response during echo trains generated by the application of shaped pulses. The associated echo amplitude maxima and effective slice thickness are presented. A new accurate method for STRAFI pulse calibration based on relative echo amplitudes is proposed.  相似文献   

10.
This study investigates the effects of developmental stage and muscle type on the mobility and distribution of water within skeletal muscles, using low-field 1H-NMR transverse relaxation measurements in vitro on four different porcine muscles (M. longissimus dorsi, M. semitendinosus, M. biceps femoris, M. vastus intermedius) from a total of 48 pigs slaughtered at various weight classes between 25 kg and 150 kg. Principal component analysis (PCA) revealed effects of both slaughter weight and muscle type on the transverse relaxation decay. Independent of developmental stage and muscle type, distributed exponential analysis of the NMR T2 relaxation data imparted the existence of three distinct water populations, T2b, T21, and T22, with relaxation times of approximately 1–10, 45–120, and 200–500 ms, respectively. The most profound change during muscle growth was a shift toward faster relaxation in the intermediate time constant, T21. It decreased by approx. 24% in all four muscle types during the period from 25 to 150 kg live weight. Determination of dry matter, fat, and protein content in the muscles showed that the changes in relaxation time of the intermediate time constant, T21, during growth should be ascribed mainly to a change in protein content, as the protein content explained 77% of the variation in the T21 time constant. Partial least squares (PLS) regression revealed validated correlations in the region of 0.58 to 0.77 between NMR transverse relaxation data and muscle development for all the four muscle types, which indicates that NMR relaxation measurements may be used in the prediction of muscle developmental stage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号