1.
Behar V  Adam D 《Ultrasonics》2004,42(10):1101-1109
A linear array imaging system with coded excitation is considered, where the proposed excitation/compression scheme maximizes the signal-to-noise ratio (SNR) and minimizes sidelobes at the output of the compression filter. A pulse with linear frequency modulation (LFM) is used for coded excitation. The excitation/compression scheme is based on the fast digital mismatched filtering. The parameter optimization of the excitation/compression scheme includes (i) choice of an optimal filtering function for the mismatched filtering; (ii) choice of an optimal window function for tapering of the chirp amplitude; (iii) optimization of a chirp-to-transducer bandwidth ratio; (iv) choice of an appropriate n-bit quantizer. The simulation results show that the excitation/compression scheme can be implemented as a Dolph–Chebyshev filter including amplitude tapering of the chirp with a Lanczos window. An example of such an optimized system is given where the chirp bandwidth is chosen to be 2.5 times the transducer bandwidth and equals 6 MHz: The sidelobes are suppressed to −80 dB, for a central frequency of 4 MHz, and to −94 dB, for a central frequency of 8 MHz. The corresponding improvement of the SNR is 18 and 21 dB, respectively, when compared to a conventional short pulse imaging system. Simulation of B-mode images demonstrates the advantage of coded excitation systems of detecting regions with low contrast.  相似文献   

2.
Current medical diagnostic echo systems are mostly using harmonic imaging. This means that a fundamental frequency (e.g., 2 MHz) is transmitted and the reflected and scattered higher harmonics (e.g., 4 and 6 MHz), produced by nonlinear propagation, are recorded. The signal level of these harmonics is usually low and a well-defined transfer function of the receiving transducer is required. Studying the acoustic response of a single contrast bubble, which has an amplitude in the order of a few Pascal, is another area where an optimal receive transfer function is important.

We have developed three methods to determine the absolute transfer function of a transducer. The first is based on a well-defined wave generated by a calibrated source in the far field. The receiving transducer receives the calibrated wave and from this the transfer functions can be calculated. The second and third methods are based on the reciprocity of the transducer. The second utilizes a calibrated hydrophone to measure the transmitted field. In the third method, a pulse is transmitted by the transducer, which impinges on a reflector and is received again by the same transducer. In both methods, the response combined with the transducer impedance and beam profiles enables the calculation of the transfer function.

The proposed methods are useful to select the optimal piezoelectric material (PZT, single crystal) for transducers used in reception only, such as in certain 3D scanning designs and superharmonic imaging, and for selected experiments like single bubble behavior.

We tested and compared these methods on two unfocused single element transducers, one commercially available (radius 6.35 mm, centre frequency 2.25 MHz) the other custom built (radius 0.75 mm, centre frequency 4.3 MHz). The methods were accurate to within 15%.  相似文献   


3.
Potential of coded excitation in medical ultrasound imaging   总被引:6,自引:0,他引:6  
Improvement in signal-to-noise ratio (SNR) and/or penetration depth can be achieved in medical ultrasound by using long coded waveforms, in a similar manner as in radars or sonars. However, the time-bandwidth product (TB) improvement, and thereby SNR improvement is considerably lower in medical ultrasound, due to the lower available bandwidth. There is still space for about 20 dB improvement in the SNR, which will yield a penetration depth up to 20 cm at 5 MHz [M. O'Donnell, IEEE Trans. Ultrason. Ferroelectr. Freq. Contr., 39(3) (1992) 341]. The limited TB additionally yields unacceptably high range sidelobes. However, the frequency weighting from the ultrasonic transducer's bandwidth, although suboptimal, can be beneficial in sidelobe reduction. The purpose of this study is an experimental evaluation of the above considerations in a coded excitation ultrasound system. A coded excitation system based on a modified commercial scanner is presented. A predistorted FM signal is proposed in order to keep the resulting range sidelobes at acceptably low levels. The effect of the transducer is taken into account in the design of the compression filter. Intensity levels have been considered and simulations on the expected improvement in SNR are also presented. Images of a wire phantom and clinical images have been taken with the coded system. The images show a significant improvement in penetration depth and they preserve both axial resolution and contrast.  相似文献   

4.
张健  李成林 《应用声学》1996,15(6):21-25
本文介绍一种中心工作频率在4.5kHz发射电功率8kW的16基元线列阵发射系统,并介绍了使用DSP56001数字信号处理产生线性调频扫描波束发射信号及接收信号的频域处理和和一些测试结果。  相似文献   

5.
Correlations between acoustic properties and bone density were investigated in the 12 defatted bovine cancellous bone specimens in vitro. Speed of sound (SOS) and broadband ultrasonic attenuation (BUA) were measured in three different frequency bandwidths from 0.5 to 2 MHz using three matched pairs of transducers with the center frequencies of 1, 2.25, and 3.5 MHz. The relative orientation between ultrasonic beam and bone specimen was the mediolateral (ML) direction of the bovine tibia. SOS shows significant linear positive correlation with apparent density for all three pairs of transducers. However, BUA shows relatively weak correlation with apparent density. SOS and BUA are only weakly correlated with each other. The linear combination of SOS and BUA in a multiple regression model leads to a significant improvement in predicting apparent density. The correlations among SOS, BUA, and bone density can be effectively and clearly represented in the three-dimensional space by the multiple regression model. These results suggest that the frequency range up to 1.5 MHz and the multiple regression model in the three-dimensional space can be useful in the osteoporosis diagnosis.  相似文献   

6.
In contrast to previously published papers [A. Nowicki, Z. Klimonda, M. Lewandowski, J. Litniewski, P.A. Lewin, I. Trots, Comparison of sound fields generated by different coded excitations – Experimental results, Ultrasonics 44 (1) (2006) 121–129; J. Litniewski, A. Nowicki, Z. Klimonda, M. Lewandowski, Sound fields for coded excitations in water and tissue: experimental approach, Ultrasound Med. Biol. 33 (4) (2007) 601–607], which examined the factors influencing the spatial resolution of coded complementary Golay sequences (CGS), this paper investigates the effect of ultrasound imaging transducer’s fractional bandwidth on the gain of the compressed echo signal for different spectral widths of the CGS. Two different bit lengths were considered, specifically one and two cycles. Three transducers having fractional bandwidth of 25%, 58% and 80% and operating at frequencies 6, 4.4 and 6 MHz, respectively were examined (one of the 6 MHz sources was focused and made of composite material). The experimental results have shown that by increasing the code length, i.e. decreasing the bandwidth, the compressed echo amplitude could be enhanced. The smaller the bandwidth was the larger was the gain; the pulse-echo sensitivity of the echo amplitude increased by 1.88, 1.62 and 1.47, for 25%, 58% and 80% bandwidths, respectively. These results indicate that two cycles bit length excitation is more suitable for use with bandwidth limited commercially available imaging transducers. Further, the time resolution is retained for transducers with two cycles excitation providing the fractional bandwidth is lower than approximately 90%. The results of this work also show that adjusting the code length allows signal-to-noise-ratio (SNR) to be enhanced while using limited (less that 80%) bandwidth imaging transducers. Also, for such bandwidth limited transducers two cycles excitation would not decrease the time resolution, obtained with “conventional” spike excitation. Hence, CGS excitation could be successfully implemented with the existing, relatively narrow band imaging transducers without the need to use usually more expensive wideband, composite ones.  相似文献   

7.
为增加超声穿透高声衰减介质的能力,提出了一种衰减匹配的超声Barker码激励方法。基于换能器高斯响应与材料非频散线性衰减的假设,得到了Barker码激励的信号模型,求解旁瓣抑制滤波后脉冲压缩的信噪比表达式可知,该方法仅需要根据材料衰减特性与轴向分辨率的要求,分别调整Barker码的中心频率与时长,便可以获得更高的信噪比。取衰减系数为1.4 Np/(MHz·cm)、厚度为5 cm的橡胶为试样进行验证。当与方波激励方法的轴向分辨率相近时,衰减匹配的Barker码激励方法比传统Barker码激励方法的信噪比增益提高接近5 dB;当牺牲一定轴向分辨率时,信噪比增益提高接近11 dB。结果表明,衰减匹配的Barker码激励方法可以降低依频率衰减对脉冲压缩的影响,有效提高衰减回波的信噪比。   相似文献   

8.

Objective and motivation

The goal of this work was to test experimentally that exposing air bubbles or ultrasound contrast agents in water to amplitude modulated wave allows control of inertial cavitation affected volume and hence could limit the undesirable bioeffects.

Methods

Focused transducer operating at the center frequency of 10 MHz and having about 65% fractional bandwidth was excited by 3 μs 8.5 and 11.5 MHz tone-bursts to produce 3 MHz envelope signal. The 3 MHz frequency was selected because it corresponds to the resonance frequency of the microbubbles used in the experiment. Another 5 MHz transducer was used as a receiver to produce B-mode image. Peak negative acoustic pressure was adjusted in the range from 0.5 to 3.5 MPa. The spectrum amplitudes obtained from the imaging of SonoVueTM contrast agent when using the envelope and a separate 3 MHz transducer were compared to determine their cross-section at the - 6 dB level.

Results

The conventional 3 MHz tone-burst excitation resulted in the region of interest (ROI) cross-section of 2.47 mm while amplitude modulated, dual-frequency excitation with difference frequency of 3 MHz produced cross-section equal to 1.2 mm.

Conclusion

These results corroborate our hypothesis that, in addition to the considerably higher penetration depth of dual-frequency excitation due to the lower attenuation at 3 MHz than that at 8.5 and 11.5 MHz, the sample volume of dual-frequency excitation is also smaller than that of linear 3-MHz method for more spatially confined destruction of microbubbles.  相似文献   

9.
We are building a long-range FM/cw nonscanning imaging lidar breadboard. This lidar system achieves ranging based on a frequency modulation/continuous wave (FM/cw) technique, implemented by an amplitude modulated mid-IR diode laser transmitter with a linear frequency modulation (LFM) of the subcarrier. Firstly, various schemes of light beam modulation are analyzed. Secondly, we put forward a laser modulation scheme whose core was formed by a 1.55 μm electro-absorption modulated laser diode (EML) and an erbium-doped optical fiber amplifier (EDFA), then a corresponding experimental system architecture and components for light beam modulation and detection are established. Finally, a corresponding experiment of laser beam modulation is completed for the first time. In our experiment, the EML amplitude is modulated by a 200 MHz to 800 MHz LFM signal, whose amplitude value is 2.05 V. The average output power of the modulated laser obtained in the experiment is 10 W, peak power is 16.4 W, and the average modulation depth is 78%. The results of tests predict that this laser modulation scheme is likely to improve the imaging range of the FM/cw lidar.  相似文献   

10.
Surinder Singh  R.S. Kaler 《Optik》2008,119(7):329-339
Sufficient power margin is investigated for ten-channels WDM transmission over 68,908 km by using cascaded in-line semiconductor optical amplifier for the differential phase-shift keying (DPSK) modulation format for the first time. For this, we used the structural optimization and placement scheme of semiconductor optical amplifiers (SOAs) for long-haul WDM transmission. The SOA model for in-line amplifier has low crosstalk, ASE noise power and low noise figure with sufficient gain. The impact of noise figure, amplification factor, ASE noise power, optical gain and crosstalk with signal input power for the SOA model has been illustrated, which shows that 400 mA is the optimum bias current.

We observed that the optimized optical filter bandwidth for the 100 GHz channel spacing is 0.4 nm. We observe that as we decrease the channel spacing, the quality of signal is degraded. We show that the optimum span scheme-1 is used up to a transmission distance of 68,908 km with good quality for power margin more than 24 dB. This placement scheme of SOAs shows good power budget for long transmission distance. We show the optical spectrum and clear eye diagram at the transmission distance of 68,908 km for optimum span schemes. Finally, we investigate the maximum transmission distance with decrease in channel spacing, i.e., 20 and 50 GHz.  相似文献   