首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 999 毫秒
1.
Frequency modulation detection limens (FMDLs) were measured for five hearing-impaired (HI) subjects for carrier frequencies f(c) = 1000, 4000, and 6000 Hz, using modulation frequencies f(m) = 2 and 10 Hz and levels of 20 dB sensation level and 90 dB SPL. FMDLs were smaller for f(m) = 10 than for f(m) = 2 Hz for the two higher f(c), but not for f(c) = 1000 Hz. FMDLs were also determined with additional random amplitude modulation (AM), to disrupt excitation-pattern cues. The disruptive effect was larger for f(m) = 10 than for f(m) = 2 Hz. The smallest disruption occurred for f(m) = 2 Hz and f(c) = 1000 Hz. AM detection thresholds for normal-hearing and HI subjects were measured for the same f(c) and f(m) values. Performance was better for the HI subjects for both f(m). AM detection was much better for f(m) = 10 than for f(m) = 2 Hz. Additional tests showed that most HI subjects could discriminate temporal fine structure (TFS) at 800 Hz. The results are consistent with the idea that, for f(m) = 2 Hz and f(c) = 1000 Hz, frequency modulation (FM) detection was partly based on the use of TFS information. For higher carrier frequencies and for all carrier frequencies with f(m) = 10 Hz, FM detection was probably based on place cues.  相似文献   

2.
An experiment was conducted to measure observers' ability to detect time-varying interaural intensity differences (IIDs). In a two-interval forced-choice task, observers discriminated a binaural amplitude modulated (AM) noise in which the modulating sinusoid was interaurally in-phase from the same AM noise in which the modulator was interaurally phase-reversed. The latter stimulus produces a sinusoidally varying IID whose rate and peak IID depend on the frequency (fm) and depth (m) of modulation. The carrier was a narrow-band noise, interaurally uncorrelated, centered at 500, 1000, or 4000 Hz. Presentation level was 75 dB SPL; duration was 1.0 s. For a given fm, m was varied in an adaptive procedure to estimate the depth required for 71% discriminability (mthr). Three of the four observers displayed "low-pass" modulation functions: at 500 Hz, as fm increased from 0-50 Hz, mthr increased from 0.08 (IID = 1.3 dB) to 0.50 (peak IID = 9.5 dB). At 1000 and 4000 Hz observers were more sensitive to IID and the functions (mthr vs fm) were flatter than at 500 Hz. Comparison of these data to previously published data indicates that the binaural system can follow fluctuations in IID more efficiently than it can follow fluctuations in interaural time difference, although there are large individual differences in subjects' capacity to process these two types of binaural cues.  相似文献   

3.
This study compared the ability of 5 listeners with normal hearing and 12 listeners with moderate to moderately severe sensorineural hearing loss to discriminate complementary two-component complex tones (TCCTs). The TCCTs consist of two pure tone components (f1 and f2) which differ in frequency by delta f (Hz) and in level by delta L (dB). In one of the complementary tones, the level of the component f1 is greater than the level of component f2 by the increment delta L; in the other tone, the level of component f2 exceeds that of component f1 by delta L. Five stimulus conditions were included in this study: fc = 1000 Hz, delta L = 3 dB; fc = 1000 Hz, delta L = 1 dB; fc = 2000 Hz, delta L = 3 dB; fc = 2000 Hz, delta L = 1 dB; and fc = 4000 Hz, delta L = 3 dB. In listeners with normal hearing, discrimination of complementary TCCTs (with a fixed delta L and a variable delta f) is described by an inverted U-shaped psychometric function in which discrimination improves as delta f increases, is (nearly) perfect for a range of delta f's, and then decreases again as delta f increases. In contrast, group psychometric functions for listeners with hearing loss are shifted to the right such that above chance performance occurs at larger values of delta f than in listeners with normal hearing. Group psychometric functions for listeners with hearing loss do not show a decrease in performance at the largest values of delta f included in this study. Decreased TCCT discrimination is evident when listeners with hearing loss are compared to listeners with normal hearing at both equal SPLs and at equal sensation levels. In both groups of listeners, TCCT discrimination is significantly worse at high center frequencies. Results from normal-hearing listeners are generally consistent with a temporal model of TCCT discrimination. Listeners with hearing loss may have deficits in using phase locking in the TCCT discrimination task and so may rely more on place cues in TCCT discrimination.  相似文献   

4.
The present study investigated the hypothesis that the cues for modulation rate discrimination for unresolved spectral components differ as a function of the spectral region occupied by the stimuli. Specifically, it was hypothesized that when components occupy relatively low spectral regions, phase locking both to the fine structure and to the envelope are useful cues. However, as the spectral region occupied by the components increases, phase locking to the fine structure becomes less robust, whereas phase locking to the envelope remains as a potentially strong cue. Observers were asked to detect a decrease in modulation rate for carrier frequencies between 1500 and 6000 Hz. Both amplitude-modulated (AM) and quasifrequency-modulated (QFM) tones were used in order to produce stimuli having strong and weak envelope cues, respectively. Although there were marked individual differences, the results showed an interaction between modulation type and spectral region, with AM and QFM performance being relatively similar at low spectral region, but with QFM showing a steeper reduction in performance as the spectral region of the carrier frequency increased. Overall, the data are consistent with an interpretation that pitch perception for unresolved components depends upon both fine structure and envelope cues, and that the relative importance of these cues depends upon the spectral region occupied by the stimuli.  相似文献   

5.
The improvement in amplitude modulation (AM) detection thresholds with increasing level of a sinusoidal carrier has been attributed to listening on the high-frequency side of the excitation pattern, where the growth of excitation is more linear, or to an increase in the number of "channels" via spread of excitation. In the present study, AM detection thresholds were measured using a 1000-Hz sinusoidal carrier. Thresholds for modulation frequencies of 4-64 Hz improved by about 10-20 dB as the carrier level increased from 10 dB SL (14.5 dB SPL on average) to 80 dB SPL. To minimize the use of spread of excitation with an 80-dB carrier, tonal "restrictors" with frequencies of 501, 801, 1210, and 1510 Hz were used alone and in combination. High-frequency restrictors elevated AM detection thresholds, whereas low-frequency restrictors did not, indicating that excitation on the high side is more important for detecting AM. Results of modeling suggest that the improvement in AM detection thresholds at high levels is likely due to the use of a relatively linear growth of response on the high-frequency side of the excitation pattern.  相似文献   

6.
Auditory steady-state responses (ASSRs) were elicited by simultaneously presenting multiple AM (amplitude-modulated) tones with carrier frequencies of 500, 1000, 2000, and 4000 Hz and modulation frequencies of 77, 85, 93, and 102 Hz, respectively. Responses were also evoked by separately presenting single 500- or 2000-Hz AM tones. The objectives of this study were (i) to determine the cochlear place specificity of single and multiple ASSRs using high-pass noise masking and derived-band responses, and (ii) to determine if there were any differences between single- and multiple-stimulus conditions. For all carrier frequencies, derived-band ASSRs for 1-octave-wide derived bands ranging in center frequency from 0.25 to 8 kHz had maximum amplitudes within a 1/2 octave of the carrier frequency. For simultaneously presented AM tones of 500, 1000, 2000, and 4000 Hz, bandwidths for the function of derived-band ASSR amplitude by derived-band center frequency were 476, 737, 1177, and 3039 Hz, respectively. There were no significant differences when compared to bandwidths of 486 and 1371 for ASSRs to AM tones of 500 or 2000 Hz presented separately. Results indicate that ASSRs to moderately intense stimuli (60 dB SPL) reflect activation of reasonably narrow cochlear regions, regardless of presenting AM tones simultaneously or separately.  相似文献   

7.
The ratios between the modulation index (eta) for just noticeable FM of a sinusoidally modulated pure tone and the degree of modulation (m) for just noticeable AM at the same carrier and the same modulation frequency were measured at carrier frequencies of 0.125, 0.25, 0.5, 1, 2, 4, and 8 kHz. Signal levels were 20 dB SL and 50 dB SPL or 80 dB SPL. At low modulation frequencies, for example, 8 Hz, AM and FM elicit very different auditory sensations (i.e., a fluctuation in loudness or pitch, respectively). In this case, eta and m show different values for just noticeable modulation. Since both stimuli have almost equal amplitude spectra if eta equals m (m less than 0.3), the difference in detection thresholds reflects differences in the phase relation between carrier and sidebands in AM and FM. With increasing modulation frequency, the eta-m ratio decreases and reaches unity at a modulation frequency called the "critical modulation frequency" (CMF). At modulation frequencies above the CMF, the same modulation thresholds are obtained for AM and FM. Therefore, it can be concluded that the difference in phase between the two types of stimuli is not perceived in this range. At center frequencies below 1 kHz, where phase errors caused by headphones and ear canal presumably are small, the CMF is useful in estimating critical bandwidth.  相似文献   

8.
Frequency difference limens (FDLs) were estimated for 3-, 6-, and 12-month-old infants and for adults using pure tones at 500, 1000, and 4000 Hz. Each listener provided an FDL at 40 dB and at a higher (80 dB, in most cases) sensation level (SL). An observer-based behavioral testing technique was used. The FDLs of 3-month-olds were worse than those of adults at all three frequencies, and increased with increasing frequency. The FDLs of 6- and 12-month-olds were worse than those of adults at 500 and 1000 Hz, but not at 4000 Hz. Decreasing the SL led to an increase in the FDL of about the same magnitude at all ages, and the same age differences were found at both SLs. Thus infant-adult differences in FDL are not a simple consequence of differences in absolute sensitivity. Infant FDLs at one SL were also found to be significantly correlated with the FDL at the other SL. The FDLs at one age were, in general, predictive of the FDL at a later age in a longitudinal sample of infants. Models that might account for these age-related differences are discussed.  相似文献   

9.
This article is concerned with the detection of mixed modulation (MM), i.e., simultaneously occurring amplitude modulation (AM) and frequency modulation (FM). In experiment 1, an adaptive two-alternative forced-choice task was used to determine thresholds for detecting AM alone. Then, thresholds for detecting FM were determined for stimuli which had a fixed amount of AM in the signal interval only. The amount of AM was always less than the threshold for detecting AM alone. The FM thresholds depended significantly on the magnitude of the coexisting AM. For low modulation rates (4, 16, and 64 Hz), the FM thresholds did not depend significantly on the relative phase of modulation for the FM and AM. For a high modulation rate (256 Hz) strong effects of modulator phase were observed. These phase effects are as predicted by the model proposed by Hartmann and Hnath [Acustica 50, 297-312 (1982)], which assumes that detection of modulation at modulation frequencies higher than the critical modulation frequency is based on detection of the lower sideband in the modulated signal's spectrum. In the second experiment, psychometric functions were measured for the detection of AM alone and FM alone, using modulation rates of 4 and 16 Hz. Results showed that, for each type of modulation, d' is approximately a linear function of the square of the modulation index. Application of this finding to the results of experiment 1 suggested that, at low modulation rates, FM and AM are not detected by completely independent mechanisms. In the third experiment, psychometric functions were again measured for the detection of AM alone and FM alone, using a 10-Hz modulation rate. Detectability was then measured for combined AM and FM, with modulation depths selected so that each type of modulation would be equally detectable if presented alone. Significant effects of relative modulator phase were found when detectability was relatively high. These effects were not correctly predicted by either a single-band excitation-pattern model or a multiple-band excitation-pattern model. However, the detectability of the combined AM and FM was better than would be predicted if the two types of modulation were coded completely independently.  相似文献   

10.
Psychophysical results using double vowels imply that subjects are able to use the temporal aspects of neural discharge patterns. To investigate the possible temporal cues available, the responses of fibers in the cochlear nerve of the anesthetized guinea pig to synthetic vowels were recorded at a range of sound levels up to 95 dB SPL. The stimuli were the single vowels /i/ [fundamental frequency (f0) 125 Hz], /a/ (f0, 100 Hz), and /c/ (f0, 100 Hz) and the double vowels were /a(100),i(125)/ and /c(100),i(125)/. Histograms synchronized to the period of the double vowels were constructed, and locking of the discharge to individual harmonics was estimated from them by Fourier transformation. One possible cue for identifying the f0's of the constituents of a double vowel is modulation of the neural discharge with a period of 1/f0. Such modulation was found at frequencies between the formant peaks of the double vowel, with modulation at the periods of 100 and 125 Hz occurring at different places in the fiber array. Generation of a population response based on synchronized responses [average localized synchronized rate (ALSR): see Young and Sachs [J. Acoust. Soc. Am. 66, 1381-1403 (1979)] allowed estimation of the f0's by a variety of methods and subsampling the population response at the harmonics of the f0 of the constituent vowel achieved a good reconstruction of its spectrum. Other analyses using interval histograms and autocorrelation, which overcome some problems associated with the ALSR approach, also allowed f0 identification and vowel segregation. The present study has demonstrated unequivocally that the timing of the impulses in auditory-nerve fibers provides copious possible cues for the identification of the fundamental frequencies and spectra associated with each of the constituents of double vowels.  相似文献   

11.
Loudness matches were obtained between unmodulated carriers and carriers that were amplitude modulated either periodically (rates between 2 and 32 Hz, modulation sinusoidal either on a linear amplitude scale or on a dB scale; the latter is called dB modulation) or with the envelope of the speech of a single talker. The carrier was a 4-kHz sinusoid, white noise, or speech-shaped noise. Both normally hearing subjects and subjects with cochlear hearing loss were tested. Results were expressed as the root-mean-square (rms) level of the modulated carrier minus the level of the unmodulated carrier at the point of equal loudness. If this difference is positive, this indicates that the modulated carrier has a higher rms level at the point of equal loudness. For normally hearing subjects, the results show: (1) For a 4000-Hz sinusoidal carrier, the difference was slightly positive (averaging about 0.7 dB). There was no significant effect of modulation rate or level over the range 20-80 dB SL. (2) For a speech-shaped noise or white noise carrier, the difference was close to zero, although for large modulation depths it tended to be negative. There was no clear effect of level (over the range 35-75 dB SPL) or modulation rate. For the hearing-impaired subjects, the differences were small, but tended to be slightly negative for both the 4000-Hz carrier and the noise carriers, when the modulation rate was above 2 Hz. Again, there was no clear effect of overall level. However, for dB modulation, the differences became more negative with increasing modulation depth. For modulation rates in the range 4-32 Hz, the results could be fitted reasonably well using the assumption that the loudness of modulated sounds is based on the rms value of the time-varying intensity of the response of the basilar membrane (taking into account the compression that occurs in the normal cochlea). The implications of the results for the fitting of multi-band compression hearing aids and for the design of loudness meters are discussed.  相似文献   

12.
A maximum auditory steady-state response (ASSR) amplitude is yielded when the ASSR is elicited by an amplitude-modulated tone (f(c)) with a fixed modulation frequency (f(m) = 40 Hz), whereas the maximum distortion product otoacoustic emission (DPOAE) level is yielded when the DPOAE is elicited using a fixed frequency ratio of the primary tones (f2/f1 = 1.2). When eliciting the DPOAE and ASSR by the same tone pair, optimal stimulation is present for either DPOAE or ASSR and thus adequate simultaneous DPOAE/ASSR measurement is not possible across test frequency f2 or f(c), respectively. The purpose of the present study was to determine whether the ASSR and DPOAE can be measured simultaneously without notable restrictions using a DPOAE stimulus setting in which one primary tone is amplitude modulated. A DPOAE of frequency 2f1-f2 and ASSR of modulation frequency 41 Hz were measured in ten normal hearing subjects at a test frequency between 0.5 and 8 kHz (f2 = f(c)). The decrease in the DPOAE level and the loss in ASSR amplitude during hybrid mode stimulation amounted, on average, to only 2.60 dB [standard deviation (SD) = 1.38 dB] and 1.83 dB (SD = 2.38 dB), respectively. These findings suggest simultaneous DPOAE and ASSR measurements to be feasible across all test frequencies when using a DPOAE stimulus setting where the primary tone f2 is amplitude modulated.  相似文献   

13.
To better represent fine structure cues in cochlear implants (CIs), recent research has proposed varying the stimulation rate based on slowly varying frequency modulation (FM) information. The present study investigated the abilities of CI users to detect FM with simultaneous amplitude modulation (AM). FM detection thresholds (FMDTs) for 10-Hz sinusoidal FM and upward frequency sweeps were measured as a function of standard frequency (75-1000 Hz). Three AM conditions were tested, including (1) No AM, (2) 20-Hz Sinusoidal AM (SAM) with modulation depths of 10%, 20%, or 30%, and (3) Noise AM (NAM), in which the amplitude was randomly and uniformly varied over a range of 1, 2, or 3 dB, relative to the reference amplitude. Results showed that FMDTs worsened with increasing standard frequencies, and were lower for sinusoidal FM than for upward frequency sweeps. Simultaneous AM significantly interfered with FM detection; FMDTs were significantly poorer with simultaneous NAM than with SAM. Besides, sinusoidal FMDTs significantly worsened when the starting phase of simultaneous SAM was randomized. These results suggest that FM and AM in CI partly share a common loudness-based coding mechanism and the feasibility of "FM+AM" strategies for CI speech processing may be limited.  相似文献   

14.
The purpose of this study was to compare detection of increments and decrements occurring over limited regions of time and frequency within a 500-ms broadband (0-6000 Hz) noise. Three listeners tracked detection thresholds adaptively in a two-interval, two-alternative forced-choice task. Thresholds were measured for both increments and decrements in level [delta L = 10 log10(1 + delta N0/N0) dB, where N0 is the spectral power density of the noise] as a function of signal duration (T = 30-500 ms) for a range of signal bandwidths (W = 62-6000 Hz) that were logarithmically centered around 2500 Hz. Listeners were forced to rely on temporal- and spectral-profile cues for detection due to randomization of overall presentation level from interval to interval, which rendered overall energy an inconsistent cue. Increments were detectable for all combinations of W and T, whereas decrements were not consistently detectable for W < 500 Hz. Narrow-band decrements were not detectable due to spread of excitation from the spectral edges of the noise into the decrements. Increment and decrement thresholds were similar for W > or = 1000 Hz. Temporal- and spectral-integration effects were observed for both increments and decrements. The exceptions were for random-level conditions in which the signal matched the bandwidth or duration of the standard. A multicue decision process is described qualitatively to explain how the combination of temporal- and spectral-profile cues can produce temporal- and spectral-integration effects in the absence of overall-energy cues.  相似文献   

15.
It has been proposed that the detection of frequency modulation (FM) of sinusoidal carriers can be mediated by two mechanisms; a place mechanism based on FM-induced amplitude modulation (AM) in the excitation pattern, and a temporal mechanism based on phase locking in the auditory nerve. The temporal mechanism appears to be "sluggish" and does not play a role for FM rates above about 10 Hz. It also does not play a role for high carrier frequencies (above about 5 kHz). This experiment provided a further test of the hypothesis that the effectiveness of the temporal mechanism depends upon the time spent close to frequency extremes during the modulation cycle. Psychometric functions for the detection of AM and FM were measured for two carrier frequencies, 1 and 6 kHz. The modulation waveform was quasitrapezoidal. Within each modulation period, P, a time Tss was spent at each extreme of frequency or amplitude. The transitions between the extremes, with duration Ttrans had the form of a half-cycle of a cosine function. The modulation rate was 2, 5, 10, or 20 Hz, giving values of P of 500, 200, 100, and 50 ms. TSS varied from 0 ms (sinusoidal modulation) up to 160, 80, 40, or 20 ms, for rates of 2, 5, 10, and 20 Hz, respectively. The detectability of AM was not greatly affected by modulation rate or by the value of TSS, except for a slight improvement with increasing TSS for the lowest modulation rates; this was true for both carrier frequencies. For FM of the 6-kHz carrier, the pattern of results was similar to that found for AM, which is consistent with an excitation-pattern model of FM detection. For FM of the 1-kHz carrier, performance improved markedly with increasing TSS, especially for the lower FM rates; there was no change in performance with TSS for the 20-Hz modulation rate. The results are consistent with the idea that detection of FM of a 1-kHz carrier is partly mediated by a sluggish temporal mechanism. That mechanism benefits from greater time spent at frequency extremes of the modulation cycle for rates up to 10 Hz.  相似文献   

16.
Input-output (I/O) functions for stimulus-frequency (SFOAE) and distortion-product (DPOAE) otoacoustic emissions were recorded in 30 normal-hearing adult ears using a nonlinear residual method. SFOAEs were recorded at half octaves from 500-8000 Hz in an L1=L2 paradigm with L2=0 to 85 dB SPL, and in a paradigm with L1 fixed and L2 varied. DPOAEs were elicited with primary levels of Kummer et al. [J. Acoust. Soc. Am. 103, 3431-3444 (1998)] at f2 frequencies of 2000 and 4000 Hz. Interpretable SFOAE responses were obtained from 1000-6000 Hz in the equal-level paradigm. SFOAE levels were larger than DPOAEs levels, signal-to-noise ratios were smaller, and I/O functions were less compressive. A two-slope model of SFOAE I/O functions predicted the low-level round-trip attenuation, the breakpoint between linearity and compression, and compressive slope. In ear but not coupler recordings, the noise at the SFOAE frequency increased with increasing level (above 60 dB SPL), whereas noise at adjacent frequencies did not. This suggests the existence of a source of signal-dependent noise producing cochlear variability, which is predicted to influence basilar-membrane motion and neural responses. A repeatable pattern of notched SFOAE I/O functions was present in some ears, and explained using a two-source mechanism of SFOAE generation.  相似文献   

17.
Moore and Se?k [J. Acoust. Soc. Am. 125, 3186-3193 (2009)] measured discrimination of a harmonic complex tone and a tone in which all harmonics were shifted upwards by the same amount in Hertz. Both tones were passed through a fixed bandpass filter and a background noise was used to mask combination tones. Performance was well above chance when the fundamental frequency was 800 Hz, and all audible components were above 8000 Hz. Moore and Se?k argued that this suggested the use of temporal fine structure information at high frequencies. However, the task may have been performed using excitation-pattern cues. To test this idea, performance on a similar task was measured as a function of level. The auditory filters broaden with increasing level, so performance based on excitation-pattern cues would be expected to worsen as level increases. The results did not show such an effect, suggesting that the task was not performed using excitation-pattern cues.  相似文献   

18.
An excitation-pattern algorithm is described which provides an estimate of cancellation level and phase for the (2f1-f2) and (f2-f1) distortion products. An experiment is first conducted to demonstrate the need for such an algorithm for (f2-f1) level predictions. The results of this experiment, which employed three pairs of primaries having complementary input levels (L1 = 65, L2 = 85 dB; L1 = 85, L2 = 65 dB), do not agree with the predictions of another similar algorithm [E. Zwicker, J. Acoust. Soc. Am. 69, 1410-1413 (1981)]. A new excitation-pattern algorithm is then described. The predicted level behavior for (f2-f1) and (2f1-f2) is more accurate for the proposed algorithm. In addition, an accurate phase estimate is also provided by the new algorithm.  相似文献   

19.
When a signal is higher in frequency than a narrow-band masker, thresholds are lower when the masker envelope fluctuates than when it is constant. This article investigates the cues used to achieve the lower thresholds, and the factors that influence the amount of threshold reduction. In experiment I the masker was either a sinusoid (constant envelope) or a pair of equal-amplitude sinusoids (fluctuating envelope) centered at the same frequency as the single sinusoid (250, 1000, 3000, or 5275 Hz). The signal frequency was 1.8 times the masker frequency. At all center frequencies, thresholds were lower for the two-tone masker than for the sinusoidal masker, but the effect was smaller at the highest and lowest frequencies. The reduced effect at high frequencies is attributed to the loss of a cue related to phase locking in the auditory nerve. The reduced effect at low frequencies can be partly explained by reduced slopes of the growth-of-masking functions. In experiment II the masker was a sinusoid amplitude modulated at an 8-Hz rate. Masker and signal frequencies were the same as for the first experiment. Randomizing the modulation depth between the two halves of a forced-choice trial had no effect on thresholds, indicating that changes in modulation depth are not used as a cue for signal detection. Thresholds in the modulated masker were higher than would be predicted if they were determined only by the masker level at minima in the envelope, and the threshold reduction produced by modulating the master envelope was less at 250 Hz than at higher frequencies. Experiments III and IV reveal two factors that contribute to the reduced release from masking at low frequencies: The rate of increase of masked threshold with decreasing duration is greater at 250 Hz than at 1000 Hz; the amount of forward masking, relative to simultaneous masking, is greater at 250 Hz than at 1000 Hz. The results are discussed in terms of the relative importance of across-channel cues and within-channel cues.  相似文献   

20.
The effect on modulation detection interference (MDI) of timing of gating of the modulation of target and interferer, with synchronously gated carriers, was investigated in three experiments. In a two-interval, two-alternative forced choice adaptive procedure, listeners had to detect 15 Hz sinusoidal amplitude modulation (AM) or frequency modulation (FM) imposed for 200 ms in the temporal center of a 600 ms target sinusoidal carrier. In the first experiment, 15 Hz sinusoidal FM was imposed in phase on both target and interferer carriers. Thresholds were lower for nonoverlapping than for synchronous modulation of target and interferer, but MDI still occurred for the former. Thresholds were significantly higher when the modulators were gated synchronously than when the interferer modulator was gated on before and off after that of the target. This contrasts with the findings of Oxenham and Dau [J. Acoust. Soc. Am. 110, 402-408 (2001)], who reported no effect of modulation asynchrony on AM detection thresholds, using a narrowband noise modulator. Using FM, experiment 2 showed that for temporally overlapping modulation of target and interferer, modulator asynchrony had no significant effect when the interferer was modulated by a narrowband noise. Experiment 3 showed that, for AM, synchronous gating of modulation of the target and interferer produced lower thresholds than asynchronous gating, especially for sinusoidal modulation of the interferer. Results are discussed in terms of specific cues available for periodic modulation, and differences between perceptual grouping on the basis of common AM and FM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号