首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
在预混甲烷/空气燃烧的平面火焰炉上,采用脉冲式光腔衰荡光谱技术(cavity ring-down spectroscopy, CRDS)实现了对OH分子浓度的定量测量。根据光腔衰荡吸收光谱理论,选取OH的A2Σ+-X2Π(0,0)电子跃迁带中的P1(2)吸收谱线构搭建了一套激光波长在308.6 nm的脉冲CRDS实验装置。脉冲CRDS装置中的衰荡光腔是由一对反射率为99.7%的高反射镜组成且其衰荡腔的腔长为270 cm,并测量空腔(光腔中无火焰)的衰荡时间为2.33μs。通过理论分析影响浓度精确测量的实验参数,分别采用平面激光诱导荧光(planar laser induced fluorescence, PLIF)、相干反斯托克斯拉曼散射(coherent anti-stokes Raman scattering, CARS)和脉冲CRDS三种技术精确测量OH的有效吸收长度、高温火焰的温度和有效的光腔衰荡时间。当在平面火焰炉上燃烧预混的甲烷(1.1 L·min-1)和空气(15...  相似文献   

2.
搭建了基于近红外连续激光器的高灵敏度快速扫描光腔衰荡光谱仪(SC-CRDS)。通过压电陶瓷(PZT)快速扫描腔长,并用跟踪电路使腔长自动跟踪激光波长变化,实现衰荡光谱的快速测量。利用CH4在1653.73 nm(6046.95 cm-1)附近的光谱吸收峰,用该装置对CH4气体含量进行测量。通过测量多个光谱点确定吸收线中心吸收峰值和激光波长,并反馈补偿激光中心波长使其稳定在吸收线,成功解决了由于激光器波长/频率严重漂移导致的不能持续准确测量问题。利用标准浓度的CH4样品校准其1653.73 nm吸收峰谱线强度。该光腔衰荡光谱仪装置结构简单,性能稳定,CH4浓度检测限达到1.0×10-9,可用于长时间监测室外空气中的CH4浓度。  相似文献   

3.
几乎所有小的气相分子(如H2O,CO2等)均具有独特的近红外吸收光谱,在负压条件下,每种微小的气相分子都拥有一对一的特征光谱线,基于这一原理人们开始使用激光光谱(IRIS)技术来准确分析气体样品中的同位素组成。该方法克服了传统同位素比质谱(isotope ratio mass spectrometry, IRMS)方法的局限性,已经成为公认的高精度、高灵敏度和高准确度的痕量气体检测方法。以大气水汽稳定同位素研究为例,大气水汽稳定同位素组成对水汽源区及其通道上的输送过程等水循环研究有着重要的指示意义。激光光谱技术使得大气水汽氢氧稳定同位素(δ18O和δD)野外原位连续高分辨率观测成为可能。但是,其观测精度和准确度受仪器运作特点、不同浓度大气水汽对特定光谱吸收性的敏感性差异等因素的影响,通常观测结果具有明显的非线性响应问题。因此,有必要对仪器观测过程中出现的各种偏差进行校正,但现阶段许多用户对新观测技术的国际校正方法尚不清楚。因此,基于波长扫描-光腔衰荡光谱(WS-CRDS)技术的大气水汽同位素观测系统(Picarro L2120-i),通过可调谐二极管激光器(Tunable Diode Laser, TDL)发射可被待测气体分子所吸收的不同波长的激光,测量不同波长下的衰荡时间(即有样品吸收的衰荡时间);TDL发射不能被待测气体吸收的不同波长的激光,测量每个波长下的衰荡时间(相当于无样品吸收的衰荡时间)。通过分析有无样品吸收的衰荡时间差,高精度计算待测气体的分子浓度,进而计算水汽稳定同位素组成。从记忆效应、漂移效应、浓度效应等方面,系统建立了一套准确可靠的大气水汽稳定同位素观测流程与校正方法,为正在使用或将要使用此类设备的研究人员提供参考,以获得高精度和高可靠性的大气水汽稳定同位素观测数据。  相似文献   

4.
腔衰荡光谱技术是一种高灵敏的腔增强分子吸收光谱测量技术,由于激光频率噪声大,导致激光到腔耦合效率低,严重限制了其对痕量气体的探测灵敏度.光学反馈可以有效压窄半导体激光器的线宽,提高激光到外部谐振腔的耦合效率.本文基于精细度为7800的Fabry-Pérot腔,发展了光学反馈线性腔衰荡光谱技术.首先从光场相位的角度给出了线性腔光学反馈的原理,然后分析了影响测量不确定性的因素,包括光学反馈率、衰荡信号触发阈值、探测器相对透射汇聚光斑位置等.实验结果表明,通过设置低反馈率(3%自由光谱区间)、高衰荡信号触发阈值(90%腔模幅度)以及将光斑聚焦到探测器有效面中心等措施,结合光学反馈效应,可将空腔衰荡时间的相对不确定度提升至0.026%,远优于传统腔衰荡技术获得的典型值.系统在积分时间为180 s时,获得探测灵敏度为1.3×10–10 cm–1,对应甲烷的最小可探测吸收体积浓度为0.35×10–9,从而满足了碳监测的要求.  相似文献   

5.
建立了一套脉冲激光腔衰荡光谱实验装置,并将光腔衰荡光谱技术用于原子束吸收光谱的测量,得到了Ba原子的6s6p^1P1←6s6s^1S0吸收线,进一步得出Ba原子在553.548nm附近的吸收系数,同时对吸收系数与原子炉温度的关系进行了分析,得到了较好的实验结果。  相似文献   

6.
基于通讯波段的分布式反馈半导体激光器(DFB),搭建了一套光腔衰荡光谱仪(CRDS)。衰荡光腔由一对反射率高于99.997%的高反镜组成,衰荡腔长约为130 cm,空腔衰荡时间约为150 μs。当光谱平均次数达到1 000次时,光谱仪灵敏度(最小可探测吸收系数)达到5×10-12 cm-1。利用热隔绝的方式稳定衰荡腔长,并使用衰荡光腔自身作为光学标准具,来标定光谱的频率:利用反馈式光谱扫描程序步进改变激光器频率,使之与衰荡腔的纵模频率逐一匹配,从而实现所测得光谱的自动标定。通过测量一氧化碳分子在1.565 μm附近的吸收光谱,测定气体中一氧化碳的含量。将光谱测量结果和标准样品中的一氧化碳含量进行对比,对装置的定量精度进行了检验,表明其对一氧化碳的探测极限达4 ppbv。利用该装置对实际大气中一氧化碳的含量进行了实时监测。  相似文献   

7.
介绍了在409 nm处采用二极管激光腔衰荡光谱(CRDS)技术探测大气中NO2的浓度(体积分数,下同)。通过调制二极管激光器参数,优化其输出光谱,获得NO2的有效吸收截面。探讨水蒸气、臭氧及其他痕量气体可能引起的测量干扰。时间分辨率为1 s时,系统探测限为6.6×10-11。考虑到NO2气体吸收截面和系统RL(衰荡腔长与腔内气体单次吸收光程长的比值)的不确定性,该系统的测量误差为±4.5%(1σ)。在实验室条件下,该系统和非相干宽带腔增强(IBBCEAS)系统同时测量NO2样气,将二者测量结果进行了对比,测量结果具有很好的一致性,线性拟合斜率为0.988±0.005,相关性为0.99。同时该系统被应用于实际环境大气中NO2浓度的测量,测得NO2浓度在1×10-8~5×10-8范围内,平均浓度为3.5×10-8。为了证实CRDS系统的测量结果,将其与长光程差分吸收光谱(LP-DOAS)系统测量NO2浓度的结果进行对比,二者获得了较好的一致性。实验结果表明,CRDS技术可实现大气中NO2高灵敏度、高时间分辨率的在线探测。  相似文献   

8.
腔衰荡光谱技术(cavity ring-down spectroscopy, CRDS)是一种高灵敏的激光吸收光谱技术,被广泛应用于镜片反射率测量、光谱分析以及痕量气体检测等研究领域。首先从理论上描述了CRDS技术的实验原理,然后基于555定时器自行设计了一种可应用于CRDS技术的阈值电路,并通过实验进行了验证。为了优化阈值电路的性能,研究了不同输入阻抗及容抗下阈值电路对衰荡事件测量的影响。通过直接接入不同值的电容与电阻,发现输入电容越大,输入阻抗越小,对衰荡事件的测量影响越大,尤其当阈值电路输入电阻小于50 Ω时,衰荡事件的线型严重扭曲。对不同输入电阻与输入电容时C2H2气体在6 531.780 5 cm-1处的吸收信号进行了采集与分析,发现输入电容与输入电阻的改变对测量结果有很大的影响,得到的吸收信号会失真,甚至无法进行拟合。最终给出了阈值电路的最佳设计方案,在阈值电路的设计中选取的输入阻抗越大越好,最小要在100 Ω以上,选取的容抗越小越好,最好低于1 nF,同时要保证阈值电路的时间常数远小于衰荡时间。该研究对于CRDS技术应用过程中阈值电路的设计具有重要的参考价值。  相似文献   

9.
为精确测量氮气中痕量甲烷(CH_4)浓度,设计并搭建了基于三角环形腔的连续波光腔衰荡光谱(CW-CRDS)测量装置。衰荡腔为自主加工设计,由一片曲率半径为1 m直径为25 mm的凹面镜和两片直径为12.7 mm的平面镜围成,腔内光路总长为410 mm,腔体材料为殷钢。首先,对系统的基线损耗进行了测量,随后利用氮气作为混合气配置了五种不同浓度的CH_4与N_2的混合气,利用CH_4在1 653.7 nm的吸收峰(CH_42ν3带R5支)对气体进行检测,并根据吸收谱线特性,利用洛伦兹线型函数通过最小二乘法拟合出衰荡时间常数τ并计算CH_4浓度,所搭建装置对甲烷浓度(体积分数)的检测灵敏度可达54×10~(-9)(五点四亿分之一)。最后对浓度为510×10~(-9)(五千一百万分之一)的CH_4在6 046.7~6 047.2cm~(-1)范围内的吸收光谱进行了测量,并将测得数据依照腔自由光谱范围(FSR)分组后分别拟合出τ和吸收系数,将所得CH_4吸收系数与数据库中数据相比,其最大误差低于1.2×10~(-9) cm~(-1),最高精度达8.8×10~(-11) cm~(-1)。  相似文献   

10.
压强是工业生产过程中的一个重要参数,其准确测量是过程控制的关键。气体分子光谱线型和线宽取决于分子间相互作用和温度、气压等因素,利用窄线宽气体吸收光谱的压力展宽效应,可通过高分辨地测量气体吸收谱线得到压强信息,实现压力计校准。提出了一种基于光腔衰荡光谱技术和气体吸收谱线压力展宽效应的压力计校准方法。采用5.2 μm可调谐量子级联激光器,基于连续光腔衰荡光谱技术建立了压力计校准实验装置。室温下,测量水汽在1 877 cm-1附近的一吸收谱线,线宽为0.084 21 cm-1,重复性测量误差小于1.53×10-4 cm-1,对应的压强大小为98.12 kPa,检测灵敏度优于0.18 kPa,与高精度压力计读数98.14 kPa一致。利用测试谱线线宽与压强的关系得到压力展宽系数(0.087 12±0.000 965) cm-1·atm-1,与HITARN数据库参考值0.087 1 cm-1·atm-1一致。实验校准了一小量程压力计。结果表明基于光腔衰荡光谱的高分辨吸收谱线测量在压强检测和压力计校准领域具有很好的应用前景。  相似文献   

11.
四丁基溴化铵(TBAB)半笼型水合物在二氧化碳(CO2)捕集和封存技术中具有巨大的发展与应用潜力。由于晶体结构的复杂性,TBAB半笼型水合物的动力学过程尚未得到充分的研究。为了解TBAB半笼型水合物在储气方面的动力学特性,实验采用原位激光拉曼技术和多晶粉末X射线衍射仪(PXRD)对nCO2·TBAB·26H2O和nCO2·TBAB·38H2O水合物的光谱特征进行了鉴别与分析,利用原位激光拉曼技术考察了CO2分子分别进入2种晶体结构的动力学过程。研究结果表明,2种晶体结构的拉曼光谱具有较高的相似性,值得注意的是nCO2·TBAB·26H2O中位于1 309.5和1 326.9 cm-1的拉曼峰为TBA+阳离子中C-C键的变形振动峰,在nCO2·TBAB·38H2O水合物中峰基本不发生改变,但半峰宽降低,峰形也变得相对清晰;同时,nCO2·TBAB·26H2O中位于1 446.6和1 458 cm-1的拉曼峰为TBA+阳离子中C-H键的剪切振动峰,在nCO2·TBAB·38H2O水合物中分别向左、右两边发生了位移,峰形的重叠度也随之下降。依据上述2处拉曼光谱特征可以对2种晶体结构进行辨别。通过PXRD图谱可以发现2种晶体结构的衍射图谱存在着比较明显的差距。nCO2·TBAB·26H2O晶体属于四方晶系,空间群(P4/m),而nCO2·TBAB·38H2O属于正交晶系,空间群(Pmma)。图谱中2θ=8.406°和10.941°分别为nCO2·TBAB·38H2O的(200)和(220)晶面的特征峰,而2θ=5.976°和6.969°分别为nCO2·TBAB·26H2O的(012)和(003)晶面特征峰,可以用来判别样品中水合物的晶体结构。在原位拉曼测量过程中,nCO2·TBAB·26H2O和nCO2·TBAB·38H2O分别在已经合成好的TBAB·26H2O和TBAB·38H2O水合物表面形成。在276 K,2 MPa条件下,气相中的CO2分子分别进入2种晶体结构中用于储气的512笼形结构,在1 275.4和1 379.3 cm-1处形成特征峰并逐渐增长。实验以2种TBAB水合物位于1 110.3 cm-1的拉曼峰作为参考,比较了CO2在水合物中的增长速率。研究发现在反应初期的75 min内CO2在2种水合物中的含量基本保持线性增长且上升速率的差别不大。由于测量点位于水合物表面,受气体在水合物中扩散的阻力较小同时2种TBAB水合物均采用512笼形结构储气导致了储气速率相近。以上的微观晶体结构研究结果对TBAB水合物法捕集和封存CO2技术应用具有重要的意义。  相似文献   

12.
Michael A Henderson   《Surface science》1998,400(1-3):203-219
The reaction of CO2 and H2O to form bicarbonate (HCO3) was examined on the nearly perfect and vacuum annealed surfaces of TiO2(110) with temperature programmed desorption (TPD), static secondary ion mass spectrometry (SSIMS) and high resolution electron energy loss spectrometry (HREELS). The vacuum annealed TiO2(110) surface possesses oxygen vacancy sites that are manifested in electronic EELS by a loss feature at 0.75 V. These oxygen vacancy sites bind CO2 only slightly more strongly (TPD peak at 166 K) than do the five-coordinated Ti4+ sites (TPD peak at 137 K) typical of the nearly perfect TiO2(110) surface. Vibrational HREELS indicates that CO2 is linearly bound at the latter sites with a νa(OCO) frequency similar to the gas phase value. In contrast, oxygen vacancies dissociate H2O to bridging OH groups which recombine to liberate H2O in TPD at 490 K. No evidence for a reaction between CO2 and H2O is detected on the nearly perfect surface. In sequentially dosed experiments on the vacuum annealed surface at 110 K, CO2 adsorption is blocked by the presence of preadsorbed H2O, adsorbed CO2 is displaced by postdosed H2O, and there is little or no evidence for bicarbonate formation in either case. However, when CO2 and H2O are simultaneously dosed, a new CO2 TPD state is observed at 213 K, and the 166 K state associated with CO2 at the vacancies is absent. SSIMS was used to tentatively assign the 213 K CO2 TPD state to a bicarbonate species. The 213 K CO2 TPD state is not formed if the vacancy sites are filled with OH groups prior to simultaneous CO2+H2O exposure. Sticking coefficient measurements suggest that CO2 adsorption at 110 K is precursor-mediated, as is known to be the case for H2O adsorption on TiO2(110). A model explaining the circumstances under which the proposed bicarbonate species is formed involves the surface catalyzed conversion of a precursor-bound H2O–CO2 van der Waals complex to carbonic acid, which then reacts at unoccupied oxygen vacancies to generate bicarbonate, but falls apart to CO2 and H2O in the absence of these sites. This model is consistent with the conditions under which bicarbonate is formed on powdered TiO2, and is similar to the mechanism by which water catalyzes carbonic acid formation in aqueous solution.  相似文献   

13.
H2O和CH4在气候变化过程中起着关键作用,实时在线测量H2O和CH4浓度一直都是国内外学者研究的热点问题之一。利用1.653 μm可调谐半导体激光器作光源,结合反射率为99.997 6%的两片高反射镜组成离轴腔增强吸收光谱装置,开展了H2O和CH4的高灵敏度测量研究。离轴腔增强系统的有效吸收光程通过吸收面积-浓度关系法来标定,吸收面积-浓度关系法的可行性首先通过已知光程的光学吸收池进行验证,确定有效后用于标定离轴腔增强系统的有效光程。结果表明,基长为21 cm的离轴腔增强系统的有效吸收光程达到了8 626.3 m。当谐振腔内压力为5.06 kPa时,利用7组不同浓度的CH4标准气体(0.2~1.4 μmol·mol-1)对系统进行了线性响应标定测试,得到了CH4吸收的积分面积与浓度拟合关系曲线。系统的稳定性、可实现的最小探测灵敏度等信息通过Allan方差进行分析,结果表明系统对探测CH4的最佳平均时间为100 s,最小可探测浓度极限为7.5 nmol·mol-1;系统对探测H2O的最佳平均时间为200 s,最小可探测浓度极限为55 μmol·mol-1。对提高系统测量精度的数据处理方法也进行了分析研究,结果表明相比于多次平均方法,Kalman滤波能显著的提高测量精度,而且缩短了系统的响应时间。最后,利用搭建的离轴腔增强实验系统结合Kalman滤波数据处理方法对实际大气中CH4和H2O浓度进行了连续两天的测量,CH4每天平均的浓度分别为2.1和2.08 μmol·mol-1,H2O每天平均的浓度分别为11 515.6和11 628.6 μmol·mol-1,由此可知建立的离轴腔增强吸收光谱装置能够用于大气CH4和H2O的测量,另外建立的系统也可用于相关工业领域的高灵敏度CH4和H2O监测。  相似文献   

14.
CS2在当今化工等领域占据了重要地位,而CS2火灾污染事故危害性极大。通过研究CS2燃烧火焰光谱辐射以探究其火灾污染特性极为必要。搭建了CS2燃烧火焰光谱测试平台,采用黑体辐射源对VSR仪器进行了标定,通过多用途傅里叶变换(VSR)红外光谱辐射仪测试了5,10和20 cm三种燃烧尺度下CS2燃烧的火焰光谱,并通过热电偶测试了整个燃烧时间段内不同燃烧时刻下的火焰温度,以及在火焰上方安装了烟气分析仪对火焰中的燃烧产物浓度进行监测。测量了CS2整个燃烧时间段内火焰温度,以及不同燃烧时间、不同燃烧尺度下的火焰光谱、燃烧产物组分信息。测试结果表明,CS2火焰中主要含有高温SO2,CO2,CO气体和空气中卷入的H2O分子,并获取了特征污染产物SO2的浓度。由于现有光谱仪测量分辨率有限,室内实验测量的火焰尺度有限,为了能实现火灾在线监测需要建立一个火焰光谱辐射模型来反演CS2火灾时的污染物浓度相关信息。基于HITRAN数据库可知在2.7 μm附近为高温水蒸气的发射峰,4.2 μm附近特征峰为高温CO2气体的发射峰,4.7 μm附近有CO微弱的发射峰,在7.4 μm附近特征峰为高温SO2气体的发射峰,并获得了CS2燃烧时产生的SO2,CO2,CO和H2O气体在火焰燃烧相同温度下的吸收系数,通过计算得到了CS2燃烧时产生的SO2,CO2,CO和H2O混合气体的透过率与发射率,并结合气体辐射传输方程、气体吸收系数等方程,创建了CS2燃烧的火焰光谱辐射模型。利用该光谱辐射模型反演了不同燃烧时间下特征污染产物SO2的浓度,并与实验测得的数据进行了对比分析。结果表明,该模型精度高,可用于燃烧产物浓度的定量化反演,SO2分子含量在燃烧时间20,40,60和80 s时的反演精度分别是89.5%,82.5%,85.6%和86.5%。为遥感反演CS2型大尺度火灾中燃烧产物的浓度奠定基础。  相似文献   

15.
The stability of SiC coating in helium with a low concentration of O2, CO2, and H2O is a key factor for their application in improvement of oxidation resistance of graphite for high temperature gas-cooled reactors (HTGRs). Through thermodynamic analysis, it is found that the influence factor controlling the critical temperature of passive oxidation for SiC is partial pressure of active gas in helium; the critical temperature of passive oxidation for SiC increases with the partial pressure of O2, CO2, and H2O, SiC is prone to undergo active oxidation in He–CO2 and He–H2O system. SiO2/SiC multilayer coating can improve the oxidation resistance of graphite at higher temperature than SiC coating does under normal operation condition for HTGRs.  相似文献   

16.
利用分布反馈式(DFB)二极管激光器为光源, 搭建了一套2 μm波段的离轴积分腔输出光谱装置. 利用高纯甲烷气体, 测量了腔镜反射率随腔内气体压力 变化的规律. 当腔内压力为3.59 kPa 时, 标定的镜面反射率为0.99865, 在此条件下, 基长55 cm 的离轴积分腔实现了407.4 m的吸收光程. 选取CO2 在4993.7431 cm-1处的吸收谱线对实际大气中的CO2浓度进行了测量, 探测限为0.53 ppmv (1σ), 利用小波去噪对光谱信号进行了去噪处理, 信噪比提高了80%, 探测限提高到0.29 ppmv(1σ). 利用搭建的装置在实验室内测量了从上午9时到中午12时实际大气中CO2的浓度, 并与H2O/CO2分析仪进行了同时观测与对比分析, 初步验证了测量装置的可靠性.  相似文献   

17.
The electrical conductivity of Cr2O3 nominally doped with 2 mol% MgO has been studied by the four point a.c. technique as a function of the oxygen activity (O2 + Ar, CO + CO2 and H2 + H2O) in the temperature range 400–1200 °C. It is concluded that Cr2O3 doped with MgO is an extrinsic conductor and that the dissolved Mg-dopant is compensated by the formation of electron holes at near atmospheric oxygen pressures and by oxygen vacancies (or possibly interstitial chromium ions) at highly reduced oxygen activities (in CO + CO2 and H2 + H2O gas mixtures). In H2 + H2O mixtures Mg-doped chromia also dissolves hydrogen as protons and significantly affects the defect structure and electrical conductivity. The defect structure of the oxide under various conditions is discussed.  相似文献   

18.
孙远涛  张洪田 《发光学报》2015,36(3):366-369
采用紫外波段吸收光谱检测技术,实现了SO2和H2S混合气体各组分浓度的实时监测。在实验中选用氘灯为测试光源,MAYA2000Pro光谱仪用于采集数据。基于光谱的峰谷特性,选择吸收光谱上波长非常接近的两个来推导SO2气体的浓度公式,该方法可以忽略其他气体散射和吸收的影响。H2S气体的吸收光谱可以通过减去混合气体中相应的SO2气体吸收光谱获得。在常温常压下,H2S气体的浓度可以从H2S气体的吸收光谱的吸收峰获得。混合气体的测量精度约为1×10-6(1 ppm)。基于上述方法,实现了混合气体SO2和H2S浓度的实时监测。  相似文献   

19.
孙友文  谢品华  徐晋  周海金  刘诚  王杨  刘文清  司福祺  曾议 《物理学报》2013,62(13):130703-130703
采用加权函数修正的差分光学吸收光谱技术(weighting function modified differential optical absorption spectroscopy, WFM-DOAS)测量环境大气中的CO2垂直柱浓度. 以直射太阳光测量光谱为例, 演示了WFM-DOAS算法的实现过程. 将环境大气分为50层, 借助辐射传输模拟软件SCIATRAN对各个测量光谱进行了模拟计算, 获得了最小二乘法拟合所需的目标气体CO2及干扰气体H2O、CH4 的柱权重函数和太阳归一化光谱常量. 采用WFM-DOAS方法对一整天的直射太阳光测量光谱进行了反演, 得到的反演误差均小于3%. 最后比较了两种不同DOAS算法对同一条测量光谱的反演结果, 验证了WFM-DOAS算法在红外被动气体遥感的优越性. 关键词: 环境污染监测 光学测量技术 红外光谱 温室气体  相似文献   

20.
李宁  吕晓静  翁春生 《物理学报》2018,67(5):57801-057801
针对高压环境吸收谱线加宽以及波分复用技术合波透射信号分析测试难题,提出利用非线性拟合方法对激光吸收光谱测量中激光强度与吸收光谱进行耦合求解.建立激光强度非线性变化与多谱线吸收拟合函数关系,解决了特殊环境下无法获取光谱基线的难题,实现了波分复用过程合波后光谱信号的分离与诊断.通过仿真验证该方法的可行性,分析计算了激光器特性和特征谱线位置等因素对拟合结果的影响.搭建实验台实现了1—10 atm变压力环境下6330—6337 cm~(-1)波段CO_2吸收光谱叠加信号的诊断分析,对气液两相脉冲爆轰过程中7185.6 cm~(-1)与7444.35 cm~(-1)波段波分复用光谱信号进行测试与拟合,无需分光设备实现了耦合光路分离和温度计算,研究结果对激光吸收光谱技术在高压环境以及燃烧环境下波分复用技术的发展具有重要意义.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏