1.
报道了基于光阴极S波段电子直线加速器建成的9 MeV高能微焦点射线成像系统“精卫”,X射线束横向尺寸小于100 μm,7 h剂量波动低至1.6%。初步开展成像实验结果表明:双丝像质计清晰分辨13D号丝,丝直径0.05 mm,CT测试卡测得空间分辨率优于10 lp/mm,装置同时兼容电子束能量6~18 MeV可调。  相似文献   

2.
倍频腔法测BEPCⅡ直线加速器的束团长度   总被引:1,自引:1,他引:1       下载免费PDF全文
 阐述了利用倍频腔束团长度监测器测量北京正负电子对撞机二期工程电子直线加速器束团长度的原理,通过两个月的测试和数据采集,测得的束团长度集中在1.4~2.0 mm之间,与理论值1.5 mm基本相符。根据不同时刻的记录,基频腔峰值电压与束流流强探测器BCT3所测流强值近似成正比关系;当大幅改变预聚束器和聚束器参数而束流流强不变时,反映聚束质量的五倍频腔信号也随之大幅改变,而反映流强信号的基频腔信号则变化不大,这些试验结果与理论分析完全一致。  相似文献   

3.
强流低发射度光阴极微波电子枪的优化设计   总被引:2,自引:2,他引:0       下载免费PDF全文
为了实现高增益 FEL,对其关键部件光阴极微波电子枪进行了优化设计 ,还就发射度补偿技术进行了较详细的考虑 ,并用 PARMELA程序进行了粒子动力学的模拟 ,初步给出了为降低初始电子束团横向发射度的优化参数。  相似文献   

4.
光阴极微波电子枪优化设计的考虑   总被引:1,自引:0,他引:1  
对光阴极微波电子枪进行了优化设计 ,给出了光阳极微波腔的形状、电参数和电场分布 .电子束团初始参数对束流横向发射度的影响 ,用 Parmela程序对其进行了优化 ,得到了一组最优参数 .考虑了补偿线圈对束流发射度的影响 ,对线圈的位置和电流的大小做了优化 .经过优化后得到腔出口处的横向发射度为 1 .39πmm.mrad,达到了设计时的要求. A 1.3 GHz photocathode RF gun is under study in peking University. The photocathode RF gun, composed of gun cavity, photocathode and Laser system, is expected to deliver a electron beam with a normalized transverse rms emittance of 1π mm·mrad at a charge of 1nC. Its performance has been studied by the space-charge tracking code PARMELA. The influences of the initialized electron beam were also studied. The emittance compensation technique is employed. After optimization of the parameters was...  相似文献   

5.
为了实现高增益FEL,对其关键部件光阴极微波电子枪进行了优化设计,还就发射度补偿技术进行了较详细的考虑,并用PARMELA程序进行了粒子动力学的模拟,初步给出了为了降低初始电子束团横向发射度的的优化参数。  相似文献   

6.
介绍了清华大学加速器实验室近年来关于汤姆逊散射超短X射线源的研究工作;研究了在任意散射角度下电子束参数和激光束参数对散射光子参数的影响,给出了散射光子的参数如光子产额、脉冲长度、时间抖动等与电子束参数、激光束参数和散射角度的关系;利用实验室已有的16 MeV反波行波加速器与中国工程物理研究院激光聚变研究中心提供的ns调Q激光搭建了汤姆逊散射初步实验平台并开展了实验研究;加工了1.6-cell光阴极微波电子枪,搭建了高功率实验平台,对产生的电子束参数进行了初步测量;对汤姆逊散射超短X射线源进行了设计并开展了相关的平台建设工作,对产生的X射线脉冲参数进行了模拟。  相似文献   

7.
清华大学汤姆逊散射超短脉冲X射线源研究   总被引:1,自引:1,他引:0       下载免费PDF全文
 介绍了清华大学加速器实验室近年来关于汤姆逊散射超短X射线源的研究工作;研究了在任意散射角度下电子束参数和激光束参数对散射光子参数的影响,给出了散射光子的参数如光子产额、脉冲长度、时间抖动等与电子束参数、激光束参数和散射角度的关系;利用实验室已有的16 MeV反波行波加速器与中国工程物理研究院激光聚变研究中心提供的ns调Q激光搭建了汤姆逊散射初步实验平台并开展了实验研究;加工了1.6-cell光阴极微波电子枪,搭建了高功率实验平台,对产生的电子束参数进行了初步测量;对汤姆逊散射超短X射线源进行了设计并开展了相关的平台建设工作,对产生的X射线脉冲参数进行了模拟。  相似文献   

8.
 为了提高并且采用双束加速技术以进一步提高BEPCII正电子从直线加速器注入到储存环的速率,BEPCII(Beijing Electron Positron Collider Upgrade Project) 正在建造带有两个次谐波聚束腔的新预注入器。提出了使用光阴极注入器作为BEPCII预注入器的新方案,其性能优于次谐波聚束系统:发射度和能散至多为次谐波聚束系统的1/4,100%的传输效率,没有卫星束团的干扰,等。此外,还分别对光阴极注入器在高电荷量和低电荷量两种情况下的束流动力学进行了模拟计算和优化研究,并将其性能与正在建造的次谐波聚束系统和旧聚束系统的性能进行了比较和讨论。由此光阴极注入器产生的电子束还可以在将来用作激光-等离子体或激光-非传导性加速结构的尾场加速研究。  相似文献   

9.
提出了一种利用单个谐振腔测量直线加速器束团长度的新方法。不同于传统的双谐振腔束团长度监测器,该方法仅需要使用单个谐振腔,省去了用于辅助测量的参考腔,从而简化了装置结构,节省了空间。针对国家同步辐射实验室基于可调谐红外激光的能源化学研究大型实验装置进行了监测器的物理设计。通过设定同轴探针的插入位置,解决了双模信号互相干扰的问题,利用微扰金属改变调节工作频率,克服了双模难以同时谐振的困难。利用CST软件进行建模和仿真。仿真结果表明,该监测器可实现2~5 ps束团长度的诊断,测量误差小于5%。  相似文献   

10.
刘慰仁  张士琛 《光子学报》1997,26(8):742-751
本文描述了一台基于皮秒扫描机机的电子束团纵向分布(电子束团长度)测试系统,报道了应用这套系统在中科院高能物理所北京自由电子激光装置(BFFL)S波段射频直线加速器、正负电子对撞机(BEPC)和中国原子能科学研究院L波段注入器(LBINJ)上开展的测量工作.  相似文献   

11.
The length of electron beam from a photocathode RF gun is determined by a spectrometer, according to the relative energy spread induced by the bunch length during the acceleration in a linac. For a photocathode RF gun, different laser injected phase and beam charge are studied. The compression is changed for the different laser phases, as from 10° to 30°, and the bunch length is lengthened due to the strong longitudinal space charge force, caused by the increased charge.  相似文献   

12.
An RF deflecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source.The cavity is a 2856 MHz,π-mode,3-cell standing-wave cavity,to diagnose the 3.5 MeV beam produced by photocathode electron gun.With a larger power source,the same cavity will again be used to measure the accelerated beam with energy of 50 MeV before colliding with the laser pulse.The RF design using MAFIA for both the cavity shape and the power coupler is reviewed,followed by presenting the fabrication procedure and bench measurement results of two cavities.  相似文献   

13.
RF deflecting cavity can be used for bunch length measurement and is designed to diagnose the beam produced by the photocathode electron gun which was built at Tsinghua University for the Thomson scattering experiment.Detailed discussion and calculation for measuring the 3.5 MeV bunch and another with further acceleration to 50 MeV,which is under development,are presented.A standing-wave deflecting cavity working at 2856 MHz is designed and the power feeding system has been planned.  相似文献   

14.
RF deflecting cavity can be used for bunch length measurement and is designed to diagnose the beam produced by the photocathode electron gun which was built at Tsinghua University for the Thomson scattering experiment. Detailed discussion and calculation for measuring the 3.5 MeV bunch and another with further acceleration to 50 MeV, which is under development, are presented. A standing-wave deflecting cavity working at 2856 MHz is designed and the power feeding system has been planned.  相似文献   

15.
A TW (Tera Watt) laser system based on Ti:sapphire mainly for the Tsinghua Thomson scattering X-ray light source (TTX) is being built. Both UV (ultraviolet) laser pulse for driving the photocathode radiofrequency (RF) gun and the IR (infrared) laser pulse as the electron-beam-scattered-light are provided by the system. Efforts have also been made in laser pulse shaping and laser beam transport to optimize the high-brightness electron beam production by the photocathode RF gun.  相似文献   

16.
A TW (Tera Watt) laser system based on Ti:sapphire mainly for the Tsinghua Thomson scattering X-ray light source (TTX) is being built. Both UV (ultraviolet) laser pulse for driving the photocathode radio-frequency (RF) gun and the IR (infrared) laser pulse as the electron-beam-scattered-light are provided by the system. Efforts have also been made in laser pulse shaping and laser beam transport to optimize the high-brightness electron beam production by the photocathode RF gun.  相似文献   

17.
RF deflectors can be used for bunch length measurement with high resolution. This paper describes a completed S-band traveling wave RF deflector and the bunch length measurement of the electron beam produced by the photocathode RF gun of the Shanghai DUV-FEL facility. This is the first time that such a transverse RF deflector has been developed and used to measure the bunch length of picosecond order in China. The deflector's VSWR is 1.06, the whole attenuation 0.5 dB, and the bandwidth 4.77 MHz for VSWR less than 1.1. With a laser pulse width of 8.5 ps, beam energy of 4.2 MeV, and bunch charge of 0.64 nC, the bunch lengths for different RF input power into the deflector were measured, and an averaged rms bunch length of 5.25 ps was obtained. A YAG crystal is used as a screen downstream of the deflector, with the calibrated value of 1 pix = 136 μm.  相似文献   

18.
RF deflectors can be used for bunch length measurement with high resolution. This paper describes a completed S-band traveling wave RF deflector and the bunch length measurement of the electron beam produced by the photocathode RF gun of the Shanghai DUV-FEL facility. This is the first time that such a transverse RF deflector has been developed and used to measure the bunch length of picosecond order in China. The deflector's VSWR is 1.06, the whole attenuation 0.5 dB, and the bandwidth 4.77 MHz for VSWR less than 1.1. With a laser pulse width of 8.5 ps, beam energy of 4.2 MeV, and bunch charge of 0.64 nC, the bunch lengths for different RF input power into the deflector were measured, and an averaged rms bunch length of 5.25 ps was obtained. A YAG crystal is used as a screen downstream of the deflector, with the calibrated value of 1 pix = 136 μm.  相似文献   

19.
An RF deflecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source. The cavity is a 2856 MHz, π-mode, 3-cell standing-wave cavity, to diagnose the 3.5 MeV beam produced by photocathode electron gun. With a larger power source, the same cavity will again be used to measure the accelerated beam with energy of 50~MeV before colliding with the laser pulse.  相似文献   

20.
An RF deffecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source. The cavity is a 2856 MHz, π-mode, 3-cell standing-wave cavity, to diagnose the 3.5 MeV beam produced by photocathode electron gun. With a larger power source, the same cavity will again be used to measure the accelerated beam with energy of 50 MeV before colliding with the laser pulse. The RF design using MAFIA for both the cavity shape and the power coupler is reviewed, followed by presenting the fabrication procedure and bench measurement results of two cavities.  相似文献   