首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The kinetics of the thermal decompositions of CaC2O4, SrC2O4 and BaC2O4 to their carbonates were studied by thermogravimetry at constant and at linearly increasing temperatures. Isothermally, the three oxalates decompose according to A1.43, R1.54 and R1 laws, respectively. Dynamically, the decompositions of the first two oxalates proceed in a similar way as under the isothermal conditions, whereas BaC2O4 decomposes according to a different law.Kinetic compensation laws were established for the decomposition of CaC2O4 and SrC2O4 under both isothermal and non-isothermal conditions. Such a compensation law is considered to result if correct kinetic model functionsF () are used when the isothermal and non-isothermal decompositions are regulated by the sameF().
Zusammenfassung Die Kinetik der thermischen Zersetzung von CaC2O4, SrC2O4 und BaC2O4 zu den entsprechenden Carbonaten wurde durch Thermogravimetrie bei konstanter und linear ansteigender Temperatur untersucht. Isotherm werden die drei Oxalate entsprechend A1.43, R1.54 bzw. R1 zersetzt. Dynamisch verläuft die Zersetzung der ersten zwei Oxalate auf ähnlichem Wege, während BaC2O4 nach einem davon verschiedenem Gesetz abgebaut wird. Kinetische Kompensationsgesetze wurden sowohl unter isothermen als auch unter nicht-isothermen Bedingungen für die Zersetzung von CaC2O4 und SrC2O4 ermittelt. Ein solches Kompensationsgesetz wird als Ergebnis eines solchen Vorgehens angesehen, bei dem richtige kinetische ModellfunktionenF() benutzt werden, wenn die nicht-isothermen Zersetzungen durch die gleichenF() bestimmt sind.

- , . , , A1.43, R1.54 · R1- , . , . F() «» , F().
  相似文献   

2.
Summary A simple and fast determination of trace amounts of commercially used cationic surfactants is described. After extraction from water cationic surfactants are separated by HPLC and detected by conductometry. The detection limit is 3 g/l for distearyldimethylammonium chloride, 16 g/l for ditallowimidazolinium methosulphate, and 6 g/l for dodecylpyridinium chloride.  相似文献   

3.
The interference contributions of uranium and thorium to the determination of cerium based on radionuclides141Ce and143Ce produced by irradiation in a reactor core was determined. The values of the interference contributions for141Ce were 0.28±0.01 g Ce/g U and /2.01±0.05/x10–3 g Ce/g Th, and for143Ce 1.33±0.03 g Ce/g U and /9.0±0.2/x10–3 g Ce/g Th.  相似文献   

4.
Zusammenfassung Pentachlorphenol (PCP) wurde im Plasma und Harn mittels Capillar-Gas-Chromatographie und ECD-Detektion erfaßt. Die parallele Analyse mit einem massenselektiven Detektor erbrachte nahezu identische Werte (r=0,9978). Die Nachweisgrenzen lagen bei ca. 5 g PCP/l Harn bzw. ca. 10 g PCP/l Plasma. Die Untersuchung von 27 Personen ohne beruflichen bzw. besonderen usuellen Kontakt mit Pentachlorphenol ergab mediane PCP-Konzentrationen im Plasma von 28 g/l (95.0 Perzentil 149 g/l) bzw. im Harn von 10 g/l (95.0 Perzentil 55 g/l).
Determination of pentachlorophenol in human plasma and urine samples by capillary gas chromatography with ECD- and MS-detection
Summary Pentachlorophenol (PCP) levels in plasma and urine samples were determined by capillary gaschromatography and EC-detection. The results of the parallel analysis of samples with a selective mass detector correlated well (r=0.9978). The detection limits were around 5 g PCP/l urine and around 10 g PCP/l plasma respectively. A study on 27 persons occupationally not exposed to PCP or without a known special ecological intake of PCP showed median PCP levels of 28 g/l plasma (95.0 percentile: 149 g/l plasma) and 10 g/l urine (95.0 percentile: 55 g/l).
  相似文献   

5.
Summary A method for the determination of traces of cobalt in plasma is described. The sample is digested in a test tube using a mixture of nitric and perchloric acid. Ammonium-pyrrolidine dithiocarbamate is added as chelating agent, and after pH-adjustment to pH 9±0.1, cobalt is extracted into methyl-isobutyl ketone.Recovery studies using Co-60 showed that losses of cobalt during the procedure, including digestion and extraction are less than 3%. Possible contamination from the steel needle used is tested and discussed. The coefficient of variation for the method is 9.5% at the 0.20 g/l level. A realistic determination limit following this procedure is estimated to be 0.06 g/l. Using this method, the cobalt concentration in plasma from 32 control persons was determined to 0.15 ±0.07 g/l. For 10 refinery workers daily exposed to aerosols of CoCl2 the determined average was 9.7±7.1 g/l.
Analyse von Kobalt in Plasma mit Hilfe der elektrothermischen AAS
Zusammenfassung Bei dem beschriebenen Verfahren wird die Probe mit Hilfe von Salpetersäure/Perchlorsäure aufgeschlossen. Als Komplexierungs-Reagens wird Ammonium-pyrrolidindithiocarbamat zugefügt und nach pH-Einstellung auf 9±0,1 wird Co mit Methylisobutylketon extrahiert.Mit Hilfe von Co-60 wurde festgestellt, daß die durch Aufschluß und Extraktion verursachten Verluste weniger als 3% betragen. Eine mögliche Verunreinigung durch die benutzten Stahlnadeln wurde untersucht und diskutiert. Der Variationskoeffizient beträgt 9,5% bei 0,2 g Co/l. Die Bestimmungsgrenze nach diesem Verfahren liegt bei 0,06 g Co/l. Die Kobaltkonzentration im Plasma von 32 Kontrollpersonen wurde zu 0,15±0,07 g Co/l bestimmt. Für 10 Raffineriearbeiter, die täglich CoCl2-Aerosolen ausgesetzt waren, wurde ein Durchschnitt von 9,7±7,1 g Co/l gefunden.
  相似文献   

6.
A procedure was developed for the gas-chromatographic determination of promedol (trimeperidine) and ketamine in whole blood with mass-selective detection. The detection limit for trimeperidine and ketamine in blood is 0.05 g/mL. The analytical range is 0.1–5.0 g/mL. The maximum within-series errors in the determination of the studied compounds are no higher than 14.1% for concentrations of 0.10 g/mL and 7.47% for concentrations of 1.0 g/mL. The maximum between-series relative errors are 5.75% for concentrations of 0.10 g/mL and 2.7% for concentrations of 1.0 g/mL. The procedure can be used in toxicological and clinical analyses.  相似文献   

7.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

8.
Summary The hydrocarbon composition of the particle and gas phases in the urban atmosphere has been studied by filtration and parallel adsorption on active charcoal and polyurethane foam (PUF). Gas chromatography (GC) and GC coupled to mass spectrometry (GC-MS) have been used for the analysis of the organic matter extracts obtained with each system. In the case of the particle and PUF samples these extracts were fractionated into aliphatic and aromatic compounds. This approach has allowed to identify up to 247 hydrocarbon molecules showing that C0–C5 alkylbenzenes are the major compounds in the charcoal extracts whereas C14–C23 n-alkanes, C0–C4 alkylnaphthalenes, C0–C4 alkylbiphenyls and C3–C5 alkylbenzenes are those predominantly found in the PUF materials. The particles essentially contain C17–C38 n-alkanes and parent polycyclic aromatic hydrocarbons (PAH). These qualitative differences are paralleled by a progressive concentration decrease from the more to the less volatile hydrocarbons. Thus, the total charcoal extracts average 80 g/m3, the PUF compounds represent 4 /m3 and the particle hydrocarbons 0.7 g/m3. These latter airborne materials are essentially composed of petrogenic residues 0.6 g/m3 (aliphatic fraction) whereas the pyrolytic PAH only involve 0.08 g/m3.  相似文献   

9.
Summary The quantitative determination of trace elements in human blood serum by Total Reflection X-Ray Fluorescence Analysis (TXRF) is influenced by absorption- and reflection-effects caused by the organic (proteins) and inorganic (P, S, Na, K, Ca, Cl) matrices. To minimize these effects we have developed a sample preparation technique based on the decomposition of the organic matrix and followed by the separation of the trace elements from the organic matrix by ion-exchange. The described method enables the simultaneous determination of K (1584 g), Ca (666 g), Fe (22 g), Cu (9.6 g), Zn (8.8 g), Se (0.97 g), Sn (1.3 g), Pb (0.12 g) and Rb (1.6 g) (obtained values in parentheses).

Herrn Prof. Dr. G. Tölg zum 60. Geburtstag gewidmet  相似文献   

10.
Summary Cadmium and copper at the g/g to ng/g level in plant and animal tissue reference materials, and at the g/l level in urine were determined by flame atomic absorption spectrometry using on-line sorbent extraction preconcentration based on flow injection techniques. Bonded silica reversed phase sorbent with octadecyl functional groups (RP-C 18), packed in a 100 l column, was used to collect the diethylammonium-N,N-diethyldithiocarbamate (DDTC) complex formed on-line in the sample digests at low pH. Methanol was used to elute the analyte chelates directly into the nebulizer-burner system of the spectrometer. Small air segments introduced before and after elution prevented the eluent from mixing with the sample solution and increased the sensitivity. A sampling frequency of 85/h could be obtained with a sample loading time of 30 s at a flow rate of 4.0 ml/min. The enrichment factor for both elements was 20 and the enhancement factors, including the effect of the organic solvent and with the flow spoiler removed, were 126 and 114 for cadmium and copper, respectively. The detection limits (3) were 0.15 g/l for cadmium and 0.2 g/l for copper. The precision was 2.3% and 1.4% r.s.d. for 10 g/l Cd and 45 g/l Cu, respectively (n=11). Results for the determination of cadmium and copper in various biological reference materials were typically in good agreement with certified values. Low recoveries were observed, however, for cadmium in samples containing high levels of copper and/or iron, such as bovine liver.On leave from Flow Injection Analysis Research Center, Institute of Applied Ecology, Academia Sinica, Shenyang, China  相似文献   

11.
Summary For the trace determination of sodium alkylbenzenesulphonate (ABS) by HPLC the following conditions were employed: Shimadzu ZORBAX SIL Column (5 m, 4.6 mm i.d. x 150 mm) as stationary phase, 0.2% ammoniaethanol (v/v) as mobile phase, UV detector at 225 nm, injection volume 12 l. The chromatograms of ABS were simple and sharp (detection limit of ABS 0.02 g in 12 l of ethanol). The calibration curves of ABS were linear in a concentration range of 0.03 0.3 g in 12 l of ethanol. In the case of linear sodium dodecylbenzenesulphonate positive errors of 1 4% were caused by non-ionic surfactants or laurylsulphate (6 times excess), 10 50% positive errors were caused by 2 6 times excess of household detergents.Standard water samples containing ABS were treated with a weak base anion-exchange resin, the adsorbed ABS were eluted, and then determined either by HPLC or by the methylene blue spectrophotometric method. Recoveries of ABS in water were about 92 107% by HPLC.
Bestimmung von Spuren Natriumalkylbenzolsulfonat mit Hilfe der HPLC. Anwendung auf Wasser
Zusammenfassung Für die Spurenbestimmung von Natriumalkylbenzolsulfonat (ABS) durch HPLC werden die folgenden Bedingungen empfohlen:Shimadzu ZORBAX SIL (5 m, 4,6 mm x 150 mm) als stationäre Phase, 0,2% Ammoniak/Ethanol als mobile Phase, UV-Detektor bei 225 nm, Injektionsvolumen 12 l. Die erhaltenen Chromatogramme sind einfach und scharf (Nachweisgrenze 0,02 g in 12 ml Ethanol). Die Eichkurven sind im Konzentrationsbereich von 0,03–0,3 g in 12 l Ethanol linear. Im Falle des linearen Natriumdodecylbenzolsulfonats werden bei Anwesenheit von nicht-ionischen oberflächenaktiven Substanzen oder von Laurylsulfat in 6fachem Überschuß positiver Fehler von 1–4% erhalten; bei 2–6fachem Überschuß von Haushaltswaschmitteln ergeben sich positive Fehler von 10–50%.Standard-Wasserproben werden zunächst einer Behandlung mit einem Anionenaustauscher unterzogen, die adsorbierten ABS eluiert und durch HPLC oder nach der Methylenblaumethode analysiert. Wiederfindungsraten liegen bei 92–107%.
  相似文献   

12.
Sulfur dioxide fluorescence and phosphorescence are quenched by a magnetic field. A model is suggested for the qualitative interpretation of the results.
. , - .
  相似文献   

13.
The principles of benzene hydrogenation have been studied with sulfide catalysts NI/MS2, Ni/SiO2, M/SiO2 and (Ni, M)/SiO2 (M=Mo, W) obtained via metal complex precursors or by impregnation. In bimetallic catalysts active sites of benzene hydrogenation are formed upon reduction of the active component for thiophene hydrogenolysis.
Ni/MS2, Ni/SiO2, M/SiO2, (Ni,M)/SiO2, M=Mo W, , . , .
  相似文献   

14.
Differential thermal analysis and differential scanning calorimetry techniques have been used to study the kinetics of phase transitions. The aragonite/calcite transformation was chosen as test reaction.Marked discrepancies were observed between the DTA kinetic results and those obtained from isothermal kinetic measurements. This disagreement is associated with the difficulty of determining accurately the reaction rate of the process from a DTA curve.In contrast, in DSC measurements, where the reaction rate is given by the height of the peak from the base-line, it is possible to get a satisfactory fit of the data, and the kinetic results obtained with this technique are in good agreement with the isothermal ones.
Zusammenfassung Die Differentialthermoanalyse und DSC wurden zur Untersuchung der Kinetik von Phasenübergängen eingesetzt. Die Umwandlung Aragonit/Calcit wurde als Testreaktion gewählt.Bedeutende Diskrepanzen wurden zwischen den kinetischen Ergebnissen der DTA und den durch isotherme kinetische Messungen erhaltenen Ergebnissen beobachtet. Diese Abweichungen sind damit verbunden, daß es schwierig ist, die Reaktionsgeschwindigkeit des Vorgangs aus einer DTA-Kurve genau zu ermitteln.Bei DSC-Messungen,wo die Reaktionsgeschwindigkeit durch die Höhe des Peaks von der Grundlinie gegeben ist, kann eine befriedigende Anpassung der Daten erhalten werden, und die durch diese Technik erhaltenen kinetischen Ergebnisse sind in guter Übereinstimmung mit den isothermen Ergebnissen.

. /. , . -. , , , , , .
  相似文献   

15.
Summary Spots of citrinin, ochratoxin A, aflatoxin M1 and penicillic acid on thin-layer chromatograms can be semi-quantitatively estimated by using a grey scale, commonly used in photo laboratories. The detection limits are 0.01 g for citrinin, 0.006 g for ochratoxin A, 0.002 g for aflatoxin M1 and 0.01 g for penicillic acid. Standard curves for these mycotoxins are given.
Halbquantitative Bestimmung der Mycotoxine Citrinin, Ochratoxin A, Aflatoxin M1 und Penicillinsäure auf Dünnschicht-Chromatogrammen mit Hilfe eines Graukeils
Zusammenfassung Mit Hilfe eines in Photolabors gebräuchlichen Graukeils können dünnschicht-chromatographische Flecke der obengenannten Mycotoxine halbquantitativ bestimmt werden. Die Nachweisgrenzen betragen 0,01 g für Citrinin, 0,006 g für Ochratoxin A, 0,002 g für Aflatoxin M1 und 0,01 g für Penicillinsäure. Eichkurven werden angegeben.
  相似文献   

16.
Zusammenfassung Das Verbrennen von Mischungen der exothermen Systeme Al-NaF-NaNO3 und Al-CaF2-NaNO3 wurde durch Röntgenanalyse ergänzte DTA untersucht. Um den Einfluß des durch Dissoziation von NaNO3 gebildeten Sauerstoffs zu bestimmen wurden auch Mischungen, welche anstatt NaNO3 NaNO2 oder Na2O2 enthielten, geprüft.Zwei, bei 310° bzw. 850° einsetzende exotherme Reaktionen wurden in den Gemischen vom Typ Al-NaF-NaNO3 gefunden. Die erste ist der Dissoziation von NaNO3 zuzuschreiben, die zweite ist der Anwesenheit von Luft zuzuordnen.Beide exothermen Reaktionen wurden im System Al-CaF2-NaNO3 in Richtung höherer Temperaturen verschoben. Die Untersuchung der NaNO2- oder Na2O2-haltigen Gemische anstatt NaNO3 zeigte, daß die Dissoziation von NaNO3 den zum Verbrennen benötigten Sauerstoff liefert, andererseits würde letztere Reaktion sonst nur in begrenztem Ausmaß stattfinden.
Combustion of exothermic mixtures belonging to the system Al-NaF-NaNO3 and Al-CaF2-NaNO3 was investigated by DTA and X-ray analysis. In order to determine the influence of the oxygen generated by dissociation of NaNO3, the mixtures containing NaNO2 or Na2O2 instead of NaNO3 were also examined.Two exothermic reactions starting at 310° and 850° rsp. were found in the mixtures of the Al-NaF-NaNO3 type. The first is due to the dissociation of NaNO3 and the second proceeds independence of the availability of air.Both exothermic reactions were shifted to higher temperatures in the system Al-CaF2-NaNO3. Investigation of the mixtures containing NaNO2 or Na2O2 instead of NaNO3 has proved that the dissociation of NaNO3 supplies the oxygen required for combustion which should otherwise proceed only in a limited extent.

Résumé On a étudié, par ATD et par analyse aux rayons X, la combustion des mélanges exothermiques appartenant aux systèmes Al-NaF-NaNO3 et Al-CaF2-NaNO3. Afin de déterminer l'influence de l'oxygène engendré par la dissociation de NaNO3, on a étudié de même des mélanges contenant NaNO2 ou Na2O2 au lieu de NaNO3.On a trouvé, dans les mélanges du type Al-NaF-NaNO3, des réactions exothermiques à partir des temperatures respectives de 310° et 850°. La première est due à la dissociation de NaNO3 et la seconde dépend de l'air disponible.Dans le système Al-CaF2-NaNO3 les deux réactions sont déplacées vers les températures plus élevées. L'examen de mélanges contenant NaNO2 ou Na2O2 au lieu de NaNO3 à montré que c'est la dissociation de NaNO3 qui fournit l'oxygène nécessaire pour la combustion. Celleci n'aurait lieu, autrement, que d'une manière limitée.

, l-NaF-NaNO3 Al-CaF2-NaNO3. , NaNO3, , NaNO3, , NaNO2 Na2. , Al-NaF-NaNO3 , 310° 850°. , . Al-CaF2-NaNO3 . , NaNO2 Na2O2, , , , , .
  相似文献   

17.
This paper presents a new method for the determination of Hg(II) in waters, using indirect spectrophotometric measurements of the Hg(II) dithizone complex. The reagent is a mixture of dithizone, CDTA (1,2-cyclohexylene-dinitrilo-tetraacetic acid), thiourea, ethylic alcohol and glycine. Sensitivity and working range are 0.4 g · l–1 and 2–100 g · l–1, respectively. A comparison of the results with those of the cold-vapor atomic absorption spectrometry shows a good correlation for different samples revealing only small interferences. The new method is well suited for on-line measurements, easy to run and has low cost equipment.  相似文献   

18.
A radiochemical neutron activation analysis (RNAA) combustion method coupled with a neutron exposure normalization technique was used to determine low g/kg mercury levels in three National Institute of Standards and Technology (NIST) Standard Reference Materials (SRMs). Two coals (sub-bituminous and bituminous) and a diet material were analyzed. The results obtained provided recommended values of approximately 5 g/kg for SRM 1548a Typical Diet, 24 g/kg for SRM 1635 Trace Elements in Coal (sub-bituminous), and 100 g/kg for SRM 1632b Trace Elements in Coal (bituminous).  相似文献   

19.
Summary Surface active properties of dithizone and mercury(II) dithizonate have been analyzed by means of a laboratory apparatus for bubble extraction in view of utilizing it as a preconcentration device. Dependence of extraction efficiency on various parameters has been analyzed. Particularly, the dependence on concentration has been discussed in terms of adsorption isotherm and compared with that of a typical surface-active dye (crystal violet). It has been found that quantitative recovery ( 90%) of mercury, as mercury(II) dithizonate, is obtained from solutions of sufficiently low concentration ( 0.3 g/l).
Fraktionierextraktion als Anreicherungsstufe in der Spurenelementanalyse. Eine vorläufige Untersuchung
  相似文献   

20.
A method for the determination of trace amounts of Mo, Cd, Co and Cr in biological materials by neutron activation analysis with radiochemical separation is presented. The method is based on the ion-exchange scheme developed by SAMSAHL, where Co and Cr are trapped on BioRad Chelex-100 and Cd and Mo on BioRad AG2X8. The elements Mo, Cd and Co can be determined without systematic errors. For the element chromium the situation is less clear, partially due to lack of sufficient certified reference materials for Cr. The method has been used in the characterization of candidate reference materials. Detection limits in these materials range from 1.5 g/kg for Co to 10 g/kg for Cr. Actual levels as low as 8 g/kg for Cd and 7 g/kg for Co were measured.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号