首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple and efficient method, based on ultrasound-enhanced surfactant-assisted dispersive liquid–liquid microextraction (UESA-DLLME) followed by high-performance liquid chromatography (HPLC) has been developed for extraction and determination of ketoconazole and econazole nitrate in human blood samples. In this method, a common cationic surfactant, cetyltrimethylammonium bromide (CTAB), was used as dispersant. Chloroform (40 μL) as extraction solvent was added rapidly to 5 mL blood containing 0.068 mg mL−1 CTAB. The mixture was then sonicated for 2 min to disperse the organic chloroform phase. After the extraction procedure, the mixture was centrifuged to sediment the organic chloroform phase, which was collected for HPLC analysis. Several conditions, including type and volume of extraction solvent, type and concentration of the surfactant, ultrasound time, extraction temperature, pH, and ionic strength were studied and optimized. Under the optimum conditions, linear calibration curves were obtained in the ranges 4–5000 μg L−1 for ketoconazole and 8–5000 μg L−1 for econazole nitrate, with linear correlation coefficients for both >0.99. The limits of detection (LODs, S/N = 3) and enrichment factors (EFs) were 1.1 and 2.3 μg L−1, and 129 and 140 for ketoconazole and econazole nitrate, respectively. Reproducibility and recovery were good. The method was successfully applied to the determination of ketoconazole and econazole nitrate in human blood samples.  相似文献   

2.
The possibilities of different media formed by lecithin/n-butanol (n-BuOH)/water ternary mixtures for the analysis of all-trans-retinol by fluorescence have been studied. Fluorescence intensity of retinol increases in the presence of different types of aggregates formed in these media. Analytical features are good, the detection limit and quantification limit have micrograms per liter levels, and the linear range and sensitivity are appropriate to determine retinol in cosmetic samples. The analysis of retinol in anti-wrinkle creams can be achieved directly without any pretreatment of the sample. The vesicles built up from a biocompatible surfactant (lecithin) in aqueous solution with a low amount of n-BuOH permit an appropriated media for a simple, rapid, and sensitive analytical method. This method has a linear range between 64.1 and 800 μg L−1, a sensitivity of 202.3 L mg−1, and a low detection and quantification limit at 19.2 and 64.1 μg L−1, respectively.  相似文献   

3.
A specific, sensitive and robust liquid chromatography tandem mass spectrometry method for determining oxytetracycline, tetracycline, chlortetracycline and doxycycline in royal jelly and honey samples is presented. Extraction of drug residues was performed by ammonium acetate buffer as extractant followed by a clean-up with metal chelate affinity chromatography and solid-phase extraction. Tetracycline analysis was performed using liquid chromatography–electrospray ionisation–tandem mass spectrometry. The presented method is the first validated for royal jelly and in accordance with the requirements set by Commission Decision 2002/657/EC. Recoveries of the methods, calculated spiking the samples at 5.0, 10.0, 20.0 and 30.0 μg kg−1, were 79% to 90% for honey and 77% to 90% for royal jelly. The intra-day precision (RSD) ranged between 8.1% and 15.0% for honey and from 9.1% to 16.3% for royal jelly, while inter-day precision values were from 10.2% to 17.6% and from 10.6% to 18.4% respectively for honey and royal jelly. Linearity for the four analytes was calculated from 5.0 to 50.0 μg kg−1. The decision limits (CCα) ranged from 6.2 to 6.4 μg kg−1 and from 6.1 to 6.5 μg kg−1 for honey and royal jelly, respectively. Detection capabilities values (CCβ) ranged between 7.2 and 7.7 μg kg−1 and from 7.3 to 7.9 μg kg−1 respectively for honey and royal jelly. The developed method is currently in use for confirmation of the official control analysis of honey and royal jelly samples.  相似文献   

4.
The worldwide contamination of winery by-products by mycotoxins may present a serious hazard to human and animal health. Mycotoxins are secondary metabolites of fungi with possible adverse effects on humans, animals, and crops that result in illnesses and economic losses. Mycotoxins are under continuous survey in Europe, but the regulatory aspects still need to be set up for winery by-products, which may be used in animal feed. The aim of this study was to implement a simple but reliable analytical methodology for ochratoxin A (OTA) quantification in grape pomaces in order to perform a survey of samples from the Douro Demarcated Region, Portugal. The method involved a unique preparation step, solvent extraction, followed by high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A comparative study was performed with two extraction solvents (ethyl acetate and methanol) as well as using extraction on an immunoaffinity column. The linearity range for OTA analysis was 0.05–23.5 μg L−1 with a detection limit of 0.05 μg L−1 and a precision (expressed by the coefficient of variation under repeatability conditions) of 0.4–14.7%. The percentage of recovery was on average 23.5 ± 3.6% (extraction with ethyl acetate) or 70.1 ± 2.5% (extraction with 70% methanol). Accounting for the recovery factor and the chromatographic detection limit, as well as the preconcentration factor, the limit of detection in grape pomaces is 0.04 μg kg−1 (ethyl acetate extraction) and 0.33 μg kg−1 (methanol extraction). Samples from 12 out of 13 sites in the Douro Demarcated Region showed OTA presence with concentrations not exceeding 0.4 μg kg−1. Both developed methods for evaluation of OTA in grape pomace are simple but efficient. Figure Extraction of ochratoxin A (OTA) from grape pomaces allows simple but efficient quantification of OTA in winery by-products by HPLC-FL  相似文献   

5.
A novel method was developed for the determination of captan, folpet, and captafol in apples by dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–electron capture detection (GC–ECD). Some experimental parameters that influence the extraction efficiency, such as the type and volume of the disperser solvents and extraction solvents, extraction time, and addition of salt, were studied and optimized to obtain the best extraction results. Under the optimum conditions, high enrichment factors for the compounds were achieved ranging from 824 to 912. The recoveries of fungicides in apples at spiking levels of 20.0 μg kg−1 and 70.0 μg kg−1 were 93.0–109.5% and 95.4–107.7%, respectively. The relative standard deviations (RSDs) for the apple samples at 30.0 μg kg−1 of each fungicide were in the range from 3.8 to 4.9%. The limits of detection were between 3.0 and 8.0 μg kg−1. The linearity of the method ranged from 10 to 100 μg kg−1 for the three fungicides, with correlation coefficients (r 2) varying from 0.9982 to 0.9997. The obtained results show that the DLLME combined with GC–ECD can satisfy the requirements for the determination of fungicides in apple samples. Figure Dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–electron capture detection (GC–ECD) allows satisfactory determination of fungicides in apple samples  相似文献   

6.
A rapid, sensitive and environmentally friendly method for the analysis of 14 anilines in water samples by dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO) prior to gas chromatography–mass spectrometry (GC-MS) was developed and optimized. In the proposed method, cyclohexane was used as the extraction solvent as its toxicity was much lower than that of the solvent usually used in dispersive liquid–liquid microextraction (DLLME). In the optimized conditions, the method exhibited good analytical performance. Based on a signal-to-noise ratio of 3, limits of detection for anilines were in the range of 0.07 to 0.29 μg L−1, and the linear range was 0.5–200 μg L−1 with regression coefficients (r 2) higher than 0.9977. It was efficient for qualitative and quantitative analysis of anilines in water samples. The relative standard deviations varied from 2.9 to 8.6 % depending on different compounds indicating good precision. Tap water and river water were selected for evaluating the application to real water samples. The relative recoveries of anilines for the two real samples spiked with 10 μg L−1 anilines were in the scope of 78.2–114.6 % and 77.3–115.6 %, respectively.  相似文献   

7.
A flow injection on-line determination of uranium(VI) after preconcentration in a minicolumn having amberlite XAD-4 resin impregnated with dibenzoylmethane (DBM) is described. Uranium(VI) is selectively adsorbed from aqueous solution of pH 5.5 in the minicolumn (5.5 cm long with 5.0 mm i.d.) at a flow rate of 13.6 mL min−1. The uranium(VI) complex was desorbed from the resin by 0.1 mol dm−3 HCl at a flow rate of 4.2 mL min−1 and mixed with arsenazo-III solution (0.05% solution in 0.1 mol dm−3 HCl, 4.2 mL min−1), and taken to the flow through cell of spectrophotometer where its absorbance was measured at 651 nm. Various parameters affecting the complex formation and its elution were optimized. Peak height (absorbance) was used for data analyses. The preconcentration factors of 36 and 143, detection limits of 0.9 and 0.232 μg L−1, sample throughputs of 40 and 10 were obtained for preconcentration time of 60 and 300 s, respectively. The tolerance limits of many interfering cations like Th(IV) and rare-earth elements were improved. The proposed method was applied on different water (spiked tap, well and sea water) and biological samples and good recovery was obtained. The method was also validated on mocked uranium ore sample and the results were in good agreement with the reported value.  相似文献   

8.
A sensitive and effective method for simultaneous determination of triazolopyrimidine sulfonamide herbicide residues in soil, water, and wheat was developed using ultra-performance liquid chromatography coupled with tandem mass spectrometry. The four herbicides (pyroxsulam, flumetsulam, metosulam, and diclosulam) were cleaned up with an off-line C18 SPE cartridge and detected by tandem mass spectrometry using an electrospray ionization source in positive mode (ESI+). The determination of the target compounds was achieved in <2.0 min. The limits of detection were below 1 μg kg−1, while the limits of quantification did not exceed 3 μg kg−1 in different matrices. Quantitation was determined from calibration curves of standards containing 0.05–100 μg L−1 with r 2 > 0.997. Recovery studies were conducted at three spiked levels (0.2, 1, and 5 μg kg−1 for water; 5, 10, and 100 μg kg−1 for soil and wheat). The overall average recoveries for this method in water, soil, wheat plants, and seeds at three levels ranged from 75.4% to 106.0%, with relative standard deviations in the range of 2.1–12.5% (n = 5) for all analytes.  相似文献   

9.
An anodic stripping voltammetric procedure for the determination of Cu(II) at an in situ-plated stannum film electrode (SnFE) was described. The results indicated that the SnFE had an attractive electroanalytical performance, with two distinct voltammetric stripping signals for copper and stannum, and showed the superior advantage for the determination of copper compared with the bismuth film electrode. Several experimental parameters were optimized. The SnFE exhibited highly linear behavior in the concentration range from 1.0 to 100.0 μg L−1 of Cu(II) (r = 0.994) with the detection limit of 0.61 μg L−1 (S/N = 3), and the relative standard deviation for a solution containing 40.0 μg L−1 Cu(II) was 2.2% (n = 8). The procedure has been successfully applied for the determination of Cu(II) in lake water sample.  相似文献   

10.
A new adsorbent is proposed for the solid-phase extraction of phenol and 1-naphthol from polluted water. The adsorbent (TX-SiO2) is an organosilica composite made from a bifunctional immobilized layer comprising a major fraction (91%) of hydrophilic diol groups and minor fraction (9%) of the amphiphilic long-chain nonionic surfactant Triton X-100 (polyoxyethylated isooctylphenol) (TX). Under static conditions phenol was quantitatively extracted onto TX-SiO2 in the form of a 4-nitrophenylazophenolate ion associate with cetyltrimethylammonium bromide. The capacity of TX-SiO2 for phenol is 2.4 mg g−1 with distribution coefficients up to 3.4 × 104 mL g−1; corresponding data for 1-naphthol are 1.5 mg g−1 and 3 × 103 mL g−1. The distribution coefficient does not change significantly for solution volumes of 0.025–0.5 L and adsorbent mass less than 0.03 g; 1–90 μg analyte can be easily eluted by 1–3 mL acetonitrile with an overall recovery of 98.2% and 78.3% for phenol and 1-naphthol, respectively. Linear correlation between acetonitrile solution absorbance (A 540) and phenol concentration (C) in water was found according to the equation A 540 = (6 ± 1) × 10−2 + (0.9 ± 0.1)C (μmol L−1) with a detection range from 1 × 10−8 mol L−1 (0.9 μL g−1) to 2 × 10−7 mol L−1 (19 μL g−1), a limit of quantification of 1 μL g−1 (preconcentration factor 125), correlation coefficient of 0.936, and relative standard deviation of 2.5%. A solid-phase colorimetric method was developed for quantitative determination of 1-naphthol on adsorbent phase using scanner technology and RGB numerical analysis. The detection limit of 1-naphthol with this method is 6 μL g−1 while the quantification limit is 20 μL g−1. A test system was developed for naked eye monitoring of 1-naphthol impurities in water. The proposed test kit allows one to observe changes in the adsorbent color when 1-naphthol concentration in water is 0.08–3.2 mL g−1.  相似文献   

11.
A sensitive and non chromatographic analytical procedure for the separation of inorganic selenium species in natural water has been performed. A combination of APDC coprecipitation and determination by an absolute thin layer Energy dispersive X-ray fluorescence spectrometry method was used. The influence of various analytical parameters such as element concentration, oxidation states and pH on the recoveries of Se (IV) was examined. The presence of organic matter and bicarbonate anions, typical components in Cuban groundwater samples, was also tested. Negligible matrix effects were observed. At pH 4 a 100% recovery was found for Se (IV). The coprecipitation recovery of the oxidized selenium species (Se (VI)) was null for the selected concentration range (5–100 μg L−1). When the Se (VI) was reduced by heating the solution with 4 mol L−1 HCl, quantitative recovery was also obtained. The determination of total selenium was conducted by the application of the oxidation–reduction process and the analytical procedure for Se (IV). Se (VI) content was calculated as the difference between total selenium and Se (IV). The detection limit was 0.13 μg L−1. The relative standard deviation was lower than 3.5% for 5 μg L−1 of Se (IV). The trueness of the method was verified by using standardized hydride generation-atomic absorption spectrometry technique. The results obtained using the EDXRF technique were in good agreement with the ones determined by HG-AAS. The proposed method was applied to the determination of Se (IV) in surface water and groundwater samples.  相似文献   

12.
A confirmatory and quantitative method based on liquid chromatography–electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) has been developed for simultaneous determination of seven photoinitiator residues: benzophenone, (1-hydroxycyclohexyl)phenylketone (Irgacure 184), isopropylthioxanthone (ITX), 2-ethylhexyl-(4-dimethylamino)benzoate (EHA or EHDAB), 2-methyl-1-[4-(methylthio)phenyl]-2-(4-morpholinyl)-1-propanone (Irgacure 907), (2,4,6-trimethylbenzoyl)diphenylphosphine oxide (TPO) and 2-benzyl-2-(dimethylamino)-1-(4-morpholinophenyl)-1-butanone (Irgacure 369) in packaged milk and related packaging materials. Residues of photoinitiators were extracted from milk using acetonitrile, and further enriched and purified on HLB solid-phase extraction cartridges prior to being analyzed by LC-ESI/MS/MS with selected reaction monitoring mode, while photoinitiators in packaging materials were extracted using the same solvent. Satisfactory recovery (from 80 to 111%), intra- and inter-day precision (below 12%), and low limits of quantification (from 0.1 to 5.0 μg kg−1) were evaluated from spiked samples at three concentration levels (5.0, 10.0 and 25.0 μg kg−1 for Irgacure 184 and 2.5, 5.0 and 25.0 μg kg−1 for others). These excellent validation data suggested the possibility of using the LC-ESI/MS/MS method for simultaneous determination of low-level photoinitiator residues migrating from printed food-packaging materials into milk. The method has been successfully applied to the analysis of real samples of different fat contents ranging from 8 to 30 g L−1. The photoinitiator residues were revealed to be higher in milk with higher fat content and the most important contaminations were benzophenone and ITX in concentration ranges of 2.84–18.35 and 0.83–8.87 μg kg−1, respectively.  相似文献   

13.
Neopterin is a valuable biomarker of cellular immunity associated with various pathological situations such as viral and bacterial infections, autoimmune, cardiovascular, neurodegenerative and malignant disorders. To produce specific antibodies against neopterin for a rapid multi-biomarker-based diagnosis, a novel hapten derivative was synthesized and attached to carrier proteins. The thoroughly characterized conjugates were used for immunization of BALB/c mice and rabbits. The produced monoclonal antibody reached in both direct and indirect enzyme-linked immunosorbent assay (ELISA) format LoD of 0.18 and 0.45 μg L−1, respectively, and was a superior immunoreagent for further biosensor developments with regard to assay sensitivity and material availability. The best polyclonal antibody was somewhat more sensitive in direct ELISA with LoD of 0.05 μg L−1. The optimized ELISA method was evaluated with blood samples collected from patients with renal insufficiency, patients with sepsis, patients without confirmed clinical diagnosis, and healthy volunteers. In plasma samples, neopterin concentrations ranging from 3.2 to 103 μg L−1 could be determined with the monoclonal ELISA whereas twofold lower results were obtained with the polyclonal ELISA. A satisfactory correlation of results was found between the polyclonal ELISA and IBL Neopterin ELISA kit within the concentration range 0.5–16 μg L−1 (R = 0.874; n = 40), and slightly lower correlation was found for monoclonal-based ELISA (R = 0.819; n = 40). These data show that the generated antibodies may be used as functional analytical reagents for the integration into multianalyte biochip detection systems.  相似文献   

14.
Anatoxin-a is a potent alkaloid neurotoxin produced by a number of cyanobacterial species and released in freshwaters during cyanobacterial blooms. Its high toxicity is responsible for several incidents of lethal intoxications of birds and mammals around the world; therefore anatoxin-a has to be regarded as a health risk and its concentration in lakes and water reservoirs should be monitored. Phenylalanine is a natural amino acid, also present in freshwaters, isobaric to anatoxin-a, with a very similar fragmentation pattern and LC retention. Since misidentification of phenylalanine as anatoxin-a has been reported in forensic investigations, special care must be taken in order to selectively determine traces of anatoxin-a in the presence of naturally occurring phenylalanine. A fast LC tandem MS method was developed by using a 1.8 μm 50 × 2.1 mm C18 column for the separation of anatoxin-a and phenylalanine, achieving a 3-min analysis time. Isotopically labelled phenylalanine-d 5 was employed as internal standard to compensate for electrospray ion suppression and sample preconcentration losses. Both compounds were preconcentrated 1,000-fold on a porous graphitic carbon solid-phase extraction (SPE) cartridge after adjustment of sample pH to 10.5. The method was validated by using lake water spiked at four different levels from 0.01 to 1 μg L−1. Anatoxin-a recovery ranged from 73 to 97%, intra-day precision (RSD%) ranged from 4.2 to 5.9, while inter-day precision (RSD%) ranged from 4.2 to 9.1%. Limits of detection and quantification were 0.65 and 1.96 ng L−1 respectively. The method was successfully applied for the detection of anatoxin-a in Greek lakes at concentrations ranging from less than 0.6 to 9.1 ng L−1.  相似文献   

15.
A mixed anionic–cationic surfactant cloud point extraction (CPE) has been developed using sodium dodecyl sulfate (SDS) and tetrabutylammonium bromide (TBABr) for the extraction and preconcentration of organophosphorus pesticides (OPPs) at ambient temperature before analysis by high-performance liquid chromatography. The studied OPPs were azinphos-methyl, parathion-methyl, fenitrothion, diazinon, chlorpyrifos, and prothiophos. The optimum conditions of the mixed anionic–cationic CPE were 50 mmol L−1 SDS, 100 mmol L−1 TBABr, and 10% (w/v) NaCl. The extracted OPPs were successfully separated within 11 min using the conditions of a Waters Symmetry C8 column, a flow rate of 0.8 mL min−1, a gradient elution of methanol and water, and detection at 210 nm. Linearity was found over the range 0.05–5 μg mL−1, with the correlation coefficients higher than 0.996. The enrichment factor of the target analytes was in the range 6–11, which corresponds to their limits of detection from 1 to 30 ng mL−1. High precisions (intra-day and inter-day) were obtained with relative standard deviation <1.5% (t R) and 10% (peak area). Accuracies (% recovery) of the different spiked OPP concentrations were 82.7–109.1% (water samples) and 80.3–113.3% (fruit juice samples). No contamination by the OPPs was observed in any studied samples.  相似文献   

16.
A sensitive and selective solid phase extraction procedure for the determination of trace of uranium(VI) has been developed. An alumina-sodium dodecyl sulfate coated on with pyrocatechol violet was used for preconcentration and determination of uranyl ions by spectrophotometry method using Arsenazo III reagent. Sorbed ions were quantitatively eluted using 5 mL of 0.25 mol L−1 HNO3. The effects of parameters such as pH, amount of alumina, amount of ligand, flow rate, type and concentration of elution agent were examined. The capacity of the sorbent for U(VI) was found to be 0.92 mmol g−1. The relative standard deviation was 1.28% for 10 replicate determinations of U(VI) ion in a solution with a concentration of 1.0 μg mL−1. The practical applicability of the developed sorbent was examined using synthetic and real samples such as standard reference material 2709 (San Joaquin Soil) and 2711 (Montana Soil).  相似文献   

17.
Liquid chromatography with electrospray mass spectrometry (LC–ESI-MS) instrumentation equipped with a single quadrupole mass filter has been used to determine several benzoylphenylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, lufenuron and flufenoxuron). Chromatographic and MS parameters were optimised to obtain the best sensitivity and selectivity for all pesticides. Solid-phase extraction (SPE) using C18 cartridges was applied for preconcentration of pesticide trace levels in river water samples. Recoveries of benzoylphenylurea pesticides from spiked river water (0.01 and 0.025 μg L−1) were between 73 and 110% and detection limits were between 3.5 and 7.5 ng L−1. The applicability of the method to the determination of benzoylphenylurea insecticides in spiked cucumber, green beans, tomatoes and aubergines was evaluated. Samples were extracted into dichloromethane without any clean-up step. The limits of detection ranged from 1.0 to 3.2 ng mL−1 (0.68 and 2.13 μg kg−1 in the vegetable samples). Mean recoveries ranged from 79 to 114% at spiking levels of 0.01 and 0.03 mg kg−1. The method was applied to determine traces of benzoylphenylureas in both river water and vegetable samples with precision values lower than 10%. Interferences due to the matrix effect were overcome using matrix-matched standards.  相似文献   

18.
A rapid multi-analyte method has been developed for the simultaneous determination of pesticides and mycotoxins in milk by ultra high-performance liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC–QqQ–MS/MS). A variety of methodologies has been evaluated, including solid-phase extraction (SPE), “dilute-and-shoot” (liquid–liquid extraction-based procedures), and QuEChERS (quick, easy, cheap, effective, rugged, and safe)-based methods. The optimization and development process was carried out considering that the maximum residue level for aflatoxin M1 (AFM1) in milk in the European Union (EU) is set at 0.05 μg kg−1, which is the lowest tolerance in the target compounds. The selected method consisted of an extraction by SPE using C18 as sorbent and methanol as elution solvent. The final determination was performed by UHPLC–QqQ–MS/MS. Matrix-matched standard calibration was used for quantification, obtaining recoveries in the range 60–120% with relative standard deviations <25%, at three spiking levels: 0.5, 10, and 50 μg kg−1 (ten times lower for AFM1). Limits of quantification ranged from 0.20 to 0.67 μg kg−1, which were always below or equal to the established tolerance levels by the EU. Finally, the selected method was applied to different types of milk.  相似文献   

19.
The World Health Organization states that envenomation is responsible for a high number of deaths per year, especially in equatorial areas. The only effective specific treatment is the use of hyperimmune serum (antivenom). In Brazil, Crioula breed horses are used for antivenom production, with great importance in the maintenance of public health programs. A strict biochemical and metabolic control is required to attain specificity in antiserum. Inorganic elements represent only a small fraction of whole blood. Nonetheless, they play important roles in mammalian metabolism, being responsible for controlling enzymatic reactions, respiratory and cardiac functions and ageing. In this work, whole blood samples from Crioula breed horses were analyzed by EDXRF technique. The reference interval values were determined for the elements Na (1955–2013 μg g−1), Mg (51–75 μg g−1), P (523–555 μg g−1), S (1628–1730 μg g−1), Cl (2388–2574 μg g−1), K (1649–1852 μg g−1), Ca (202–213 μg g−1), Cu (4.1–4.5 μg g−1) and Zn (2.4–2.8 μg g−1) and a comparative study with NAA results was outlined. The samples were obtained from Instituto Butantan. Both techniques showed to be appropriate for whole blood sample analyses and offer a new perspective in Veterinary Medicine.  相似文献   

20.
Determination of protein surface excess is an important way of evaluating the properties of biomaterials and the characteristics of biosensors. A single-molecule counting method is presented that uses a standard fluorescence microscope to measure coverage of a liquid/solid interface by adsorbed proteins. The extremely low surface excess of lysozyme and bovine serum albumin (BSA), in a bulk concentration range from 0.3 nmol L−1 (0.02 μg mL−1) to 3 nmol L−1 (0.2 μg mL−1), were measured by recording the counts of spatially isolated single molecules on either hydrophilic (glass) or hydrophobic (polydimethylsiloxane, PDMS) surfaces at different pH. The differences observed in amounts of adsorbed proteins under different experimental conditions can be qualitatively explained by the combined interactions of electrostatic and hydrophobic forces. This, in turn, implies that single-molecule counting is an effective way of measuring surface coverage at a liquid/solid interface. Figure Adsorption fraction of proteins on different surfaces changed with pH.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号