首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Multidimensional mass spectrometry interfaces a suitable ionization technique and mass analysis (MS) with fragmentation by tandem mass spectrometry (MS2) and an orthogonal online separation method. Separation choices include liquid chromatography (LC) and ion‐mobility spectrometry (IMS), in which separation takes place pre‐ionization in the solution state or post‐ionization in the gas phase, respectively. The MS step provides elemental composition information, while MS2 exploits differences in the bond stabilities of a polymer, yielding connectivity and sequence information. LC conditions can be tuned to separate by polarity, end‐group functionality, or hydrodynamic volume, whereas IMS adds selectivity by macromolecular shape and architecture. This Minireview discusses how selected combinations of the MS, MS2, LC, and IMS dimensions can be applied, together with the appropriate ionization method, to determine the constituents, structures, end groups, sequences, and architectures of a wide variety of homo‐ and copolymeric materials, including multicomponent blends, supramolecular assemblies, novel hybrid materials, and large cross‐linked or nonionizable polymers.  相似文献   

2.
The atmospheric pressure solids analysis probe (ASAP), in conjunction with ion mobility time-of-flight mass spectrometry (IM-ToF-MS), has been applied to the impurity profiling study of ten 2-naphthalenamines. The impurity profiles achieved by ASAP-IM-MS were compared with those obtained by liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS). All the impurities at the level of 0.1 area % and above, except for one, detected by LC-ESI-MS, were also found by ASAP-IMS analyses. In addition, one non-polar compound was detected by ASAP-IM-MS alone. The IM-MS plot of ion drift time versus m/z values offered sufficient separation between the impurities with different m/z. Therefore, instead of LC as a separation tool, IM-MS is able to provide fingerprint profiling for the ten samples analysed. The time of each analysis has been reduced from 25 min by LC-MS to less than 3 min by ASAP-IM-MS. When collision energy was applied for the selected precursor ion in the transfer T-wave, a clean MS/MS spectrum was obtained for structural elucidation of unknown impurities. The hyphenation of ASAP and IM-MS techniques represents a highly efficient approach for rapid detection and identification of impurities generated in complex reactions involved in pharmaceutical development.  相似文献   

3.
High-performance polymers are complex mixtures of materials of different size and chemical composition and with different end groups and architecture. To determine the molecular heterogeneity of such systems, hyphenation of several techniques is required. The value of coupling mass spectrometry (MS) with separation techniques has already been recognized - such methods have proved to be among the most powerful for molecular characterization of complex polymer systems.The review focuses on matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) MS coupled with liquid chromatography (LC). Such hyphenation has been used for most polymer analysis by mass spectrometry coupled with separation techniques. The advantages and/or limitations of these techniques for polymer characterization are discussed. Future prospects are briefly outlined.  相似文献   

4.
An integrated differential approach to the characterization of complex mixtures is presented which includes the targeting of liquid chromatography (LC) peaks for identification using characteristic UV adsorption of the LC peak, subsequent molecular weight and formula determination using accurate mass LC mass spectrometry (MS), and structure characterization using accurate mass LC-tandem mass spectrometry. The use of differential UV adsorption aids in narrowing the scope of the study to only specific peaks of interest. Accurate mass measurement of the molecular ion species provides molecular weight information as well as atomic composition information. The tandem MS (MS/MS) spectra provide fragmentation information which allows for structural characterization of each component. Accurate mass assignment of each of the fragment ions in the MS/MS spectrum provides atomic composition for each of the fragment ions and thus further aids in the structural characterization. These experiments are facilitated through the use of on-line LC-MS and LC-MS/MS with in-line UV detection. A synthetic toxic oil (STO) related to Toxic Oil Syndrome is studied with a focus on possible contaminants resulting from the interaction of aniline, used as a denaturant, with the normal components of the oil. A differential analysis between the STO and a control oil is performed. LC peaks were targeted using UV absorbance to indicate the possible presence of the aniline moiety. Further differential analysis was performed through the determination of the MS signals associated with each component separated on the LC. Finally, the MS/MS data was also used to determine if the fragmentation of the targeted components indicated the presence of aniline. The MS/MS and accurate mass data were used to assign the structures for the targeted components.  相似文献   

5.
The combination of liquid chromatography with mass spectrometry (LC-MS) allows non-volatile and thermally sensitive compounds to be handled. The key feature, regarding LC flowrate and MS vacuum requirements, is the LC-MS interface system. Atmospheric pressure chemical ionization (APcI) is a sensitive and widely applicable method which gives primarily molecular weight information with the ability to provide structural information if required. Applications concerning the characterization of natural antioxidants from rosemary, sage and barley are reported: the main functional groups of diterpenes (rosmanol and derivatives), the aglycone part of glycosylated flavones and the different units of polymers of flavan-3-ols (procyanidins, prodelphinidins) are shown.  相似文献   

6.
Quantification of F(2)-isoprostanes is considered a reliable index of the oxidative stress status in vivo. Several immunoassays and chromatography/mass spectrometry-based assays are available for 15-F(2t)-isoprostane quantification. However, it remains unclear if results of immunoassays using different assays can be compared with those of liquid chromatography/mass spectrometry (LC/MS) assays. Previous studies comparing enzyme-linked immunosorbent assay (ELISA) and more specific gas chromatography/mass spectrometry assays have already indicated that ELISAs may overestimate 15-F(2t)-isoprostane concentrations in human plasma. Concentrations of 15-F(2t)-isoprostane in 25 human plasma and urine samples were measured by three commercially available ELISA assays (Assay Designs, Cayman Chemical and Oxford Biomedical Research) and compared with the concentrations measured with a validated, semi-automated high-throughput HPLC tandem mass spectrometry assay (LC/LC-MS/MS). All three ELISAs measured substantially higher 15-F(2t)-isoprostane concentrations (2.1-182.2-fold higher in plasma; 0.4-61.9-fold higher in urine) than LC/LC-MS/MS. Utilization of solid-phase extraction (SPE) columns, especially isoprostane affinity purification columns, brought ELISA isoprostane urine concentrations closer to the LC/LC-MS/MS results. However, SPE did not have much of an effect on ELISA plasma concentrations which remained significantly higher than corresponding LC/LC-MS/MS results. A poor correlation not only between LC/LC-MS/MS and immunoassay results, but also among the immunoassays was found. Especially in plasma, ELISAs grossly overestimate 15-F(2t)-isoprostane concentrations and are not comparable with each other or with LC/LC-MS/MS. It is most disturbing that a sample with relatively high concentrations measured with one ELISA may show low concentrations with another ELISA, and vice versa, potentially affecting the conclusions drawn from such data. The use of specific mass spectrometry-based assays seems advisable.  相似文献   

7.
Peptide mass fingerprinting by matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry (MS) is one of the standard high-throughput methods for protein identification today. Traditionally this method has been based on spotting peptide mixtures onto MALDI targets. While this method works well for more abundant proteins, low-abundance proteins mixed with high-abundance proteins tend to go undetected due to ion suppression effects, instrumental dynamic range limitations and chemical noise interference. We present an alternative approach where liquid chromatography (LC) effluent is continuously collected as linear tracks on a MALDI target. In this manner the chromatographic separation is spatially preserved on the target, which enables generation of off-line LC-MS and LC-MS/MS data by MALDI. LC-MALDI sample collection provides improved sensitivity and dynamic range, spatial resolution of peptides along the sample track, and permits peptide mass mapping of low-abundance proteins in mixtures containing high-abundance proteins. In this work, standard and ribosomal protein digests are resolved and captured using LC-MALDI sample collection and analyzed by MALDI-TOF-MS.  相似文献   

8.
Matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) and liquid secondary ion-tandem mass spectrometry (LSI-MS/MS) have been applied to the analysis of synthetic polymers to generate values for the average mass and the mass of the end groups. The average mass values were calculated for polymethylmethacrylate and polystyrene standards from the MALDI-MS data. Abundant fragment ions of the polymers, generated by means of LSI-MS/MS, were consistent with the known structures of the end groups of the polymers. Furthermore, losses from the side chains of the polymers were also observed in the LSI-MS/MS spectra.  相似文献   

9.
The number and wide dynamic range of components found in biological matrixes present several challenges for global proteomics. In this perspective, we will examine the potential of zero-dimensional (0D), one-dimensional (1D), and two-dimensional (2D) separations coupled with Fourier-transform ion cyclotron resonance (FT-ICR) and time-of-flight (TOF) mass spectrometry (MS) for the analysis of complex mixtures. We describe and further develop previous reports on the space occupied by peptides, to calculate the theoretical peak capacity available to each separations-mass spectrometry method examined. Briefly, the peak capacity attainable by each of the mass analyzers was determined from the mass resolving power (RP) and the m/z space occupied by peptides considered from the mass distribution of tryptic peptides from National Center for Biotechnology Information's (NCBI's) nonredundant database. Our results indicate that reverse-phase-nanoHPLC (RP-nHPLC) separation coupled with FT-ICR MS offers an order of magnitude improvement in peak capacity over RP-nHPLC separation coupled with TOF MS. The addition of an orthogonal separation method, strong cation exchange (SCX), for 2D LC-MS demonstrates an additional 10-fold improvement in peak capacity over 1D LC-MS methods. Peak capacity calculations for 0D LC, two different 1D RP-HPLC methods, and 2D LC (with various numbers of SCX fractions) for both RP-HPLC methods coupled to FT-ICR and TOF MS are examined in detail. Peak capacity production rates, which take into account the total analysis time, are also considered for each of the methods. Furthermore, the significance of the space occupied by peptides is discussed.  相似文献   

10.
Functionally selective lanthanide-based ion mobility shift reagents are presented as a method to elucidate protein or peptide structural information as well as relative quantitation of protein expression profiles. Sequence information and site localization of primary amines (n-terminus and lysine), phosphorylation sites, and cysteine residues can be obtained in a data dependent manner using ion mobility-mass spectrometry (IM-MS). The high mass of the incorporated lanthanide ensures a significant shift of where the signal occurs in IM-MS conformation space. Peptide sequence information provided by the use of IM-MS shift reagents allows for both a more confident identification of peptides from complex mixtures and site localization following tandem MS experiments. Stable isotopes of the lanthanide series may also be used as relative quantitation labels since several lanthanides can be utilized in differential sample analyses.  相似文献   

11.
Quantitative analysis of liquid chromatography (LC)-mass spectrometry (MS) and tandem mass spectrometry (MS/MS) data is essential to many proteomics studies. We have developed MASIC(2) to accurately measure peptide abundances and LC elution times in LC-MS/MS analyses. This software program uses an efficient processing algorithm to quickly generate mass specific selected ion chromatograms from a dataset and provides an interactive browser that allows users to examine individual chromatograms with a variety of options.  相似文献   

12.
We have designed a semi‐online liquid chromatography/matrix‐assisted laser desorption/ionization mass spectrometry (LC/MALDI‐MS) system to introduce eluent from a octadecylsilyl (ODS) group modified monolithic silica capillary chromatographic column directly onto a sample plate for MALDI‐MS analysis. Our novel semi‐online system is useful for rapidly and sensitively examining the performance of a monolithic capillary column. An additional advantage is the small elution volume of a monolithic capillary column, which allows delicate eluents, such as 1,1,1,3,3,3,‐hexafluoroisopropyl alcohol (HFIP), to be used to achieve cost‐effective analysis. Using the semi‐online LC/MALDI‐MS system, chromatographic separation of polymers by the monolithic column with different eluents was studied. Separation of poly(methyl methacrylate) and Nylon 6/6 showed that the column functioned via size‐exclusion separation when tetrahydrofuran or HFIP eluent was used. On the other hand, the separation behavior of Nylon 11 indicated a reversed‐phase mode owing to the interaction of the polymer with the modified ODS group in the column. Using tetrahydrofuran/methanol (1:1, v/v) as the eluent, the LC/MALDI‐MS spectra of poly(lactic acid), which contains both linear and cyclic polymer structures, showed that the column could separate the hydrophobic cyclic polymer and elute it out relatively slowly. The monolithic column functions basically via size‐exclusion separation; the reversed‐phase separation by interaction with the ODS functions may have less influence on column separation. The semi‐online monolithic capillary LC/MALDI‐MS method we have developed should provide a means of effectively analyzing synthetic polymers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
A perfluorinated co-polyether was characterised in terms of the number and type of functional end groups present on the molecule. The polymer was separated chromatographically according to the polarity of the polymer end groups and the separation was coupled on-line to an electrospray ionisation time-of-flight mass spectrometer. Negative-mode electrospray ionisation of the relatively non-polar polymer was achieved by post-column addition of a polar constituent to the mobile phase. LC-MS analysis of polydisperse analytes is a highly data intensive technique and manual interpretation of the resulting data can be extremely complicated, especially for the characterisation of copolymers or polymers with end-group distributions. In order to overcome this problem, an automated data-analysis program was developed that allows the user to quickly determine the probability of the presence of a certain molecular compound. The program evaluated data in terms of the possible combinations of monomeric units and end groups that could be combined to make up the mass values present in the mass spectra. Using the program, the polymer can be characterised according to its molar-mass, chemical-composition and functionality-type distributions. A graphical representation of the LC-MS analyses is presented to give a clear overview of the two-dimensional separation. The identification of various end groups on the polymer is also presented graphically, as (a) a histogram (frequency of matches versus time), (b) a two-dimensional plot (masses that match the particular end group combination versus LC retention time) and (c) a plot of average chemical composition versus LC retention time.  相似文献   

14.
翟容容  高雯  李梦宁  杨华 《色谱》2022,40(9):782-787
离子淌度质谱(IM-MS)是一种将离子淌度分离与质谱分析相结合的新型分析技术。IM-MS的主要优势不仅是在质谱检测前提供了基于气相离子形状、大小、电荷数等因素的多一维分离,而且能够提供碰撞截面积、漂移时间等质谱信息进而辅助化合物鉴定。近年来,随着IM-MS技术的不断发展,该技术在中药化学成分分析中受到越来越多的关注。首先,IM-MS已成功应用于改善中药复杂成分尤其是同分异构体或等量异位素等成分的分离;其次,IM-MS可通过多重碎裂模式辅助高质量中药小分子质谱信息的获取;此外,IM-MS提供的高维质谱数据信息还可促进中药复杂体系多成分的整合分析。该文在对IM-MS分类和基本原理进行概述的基础上,从分离能力及分离策略、多重碎裂模式、多维质谱数据处理策略3个方面,重点综述了IM-MS在中药化学成分分析中的应用,以期为IM-MS在中药化学成分研究提供参考。  相似文献   

15.
This review covers the application of mass spectrometry (MS) and its hyphenated techniques to synthetic polymers of varying architectural complexities. The synthetic polymers are discussed as according to their architectural complexity from linear homopolymers and copolymers to stars, dendrimers, cyclic copolymers and other polymers. MS and tandem MS (MS/MS) has been extensively used for the analysis of synthetic polymers. However, the increase in structural or architectural complexity can result in analytical challenges that MS or MS/MS cannot overcome alone. Hyphenation to MS with different chromatographic techniques (2D × LC, SEC, HPLC etc.), utilization of other ionization methods (APCI, DESI etc.) and various mass analyzers (FT-ICR, quadrupole, time-of-flight, ion trap etc.) are applied to overcome these challenges and achieve more detailed structural characterizations of complex polymeric systems. In addition, computational methods (software: MassChrom2D, COCONUT, 2D maps etc.) have also reached polymer science to facilitate and accelerate data interpretation. Developments in technology and the comprehension of different polymer classes with diverse architectures have significantly improved, which allow for smart polymer designs to be examined and advanced. We present specific examples covering diverse analytical aspects as well as forthcoming prospects in polymer science.  相似文献   

16.
Benzodiazepines are among the most frequently prescribed drugs due to their sedative, hypnotic, anxiolytic, muscle relaxant and antiepileptic properties. Because of the high consumption of benzodiazepines worldwide, this class of drugs and their metabolites are frequently present in both clinical and forensic cases. For these reasons, the analysis of benzodiazepines and their metabolites in biological fluids is of great interest to clinicians and forensic toxicologists. This paper reviews procedures for multi-analyte single-stage (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) using different mass analyzers for the screening, identification and/or quantification of drugs, poisons and/or their metabolites in blood, plasma, serum or urine published since 2001. Basic information about the biosamples assayed, work-up, LC column, mobile phase, ionization type, mass spectral detection mode, matrix effects and validation data for each procedure is summarized. The feasibility of using LC-MS(/MS) techniques to identify and quantify benzodiazepines and their metabolites is also discussed.  相似文献   

17.
The detailed structural characterization of complex polymer architectures, like copolymers and polymer mixtures, by mass spectrometry presents a challenge. Even though soft ionization analyses revolutionized the characterization of large molecules and provided a means for determining the polymer’s molecular weight distribution, polydispersity, and end groups, full microstructure elucidation and monomer sequencing by soft ionization alone is not possible. The combination of high-resolution Fourier transform mass spectrometry (FTMS) and tandem mass spectrometry (MSn) provides a powerful analytical tool for addressing these challenges. This tool was used in our work to separate and identify the products of polymerization between 12-hydroxystearic acid (HSA) and stearic acid (SA), to provide precise information about the exact location of caprolactones on the Tris(2-hydroxyethyl)isocyanurate (THEIC) molecule, and to sequence a glycidyl methacrylate/methyl methacrylate (GMA/MMA) copolymer. The results highlight the value of ultrahigh resolution and tandem mass spectrometry for fine structural characterization and sequencing of polymers.  相似文献   

18.
Harry EL  Bristow AW  Wilson ID  Creaser CS 《The Analyst》2011,136(8):1728-1732
The potential of ion mobility (IM) spectrometry in combination with mass spectrometry (MS) for real-time reaction monitoring is reported. The combined IM-MS approach using electrospray ionization affords gas-phase analyte characterization based on both mass-to-charge (m/z) ratio and gas-phase ion mobility (drift time). The use of IM-MS analysis is demonstrated for the monitoring of the reaction products formed when 7-fluoro-6-hydroxy-2-methylindole is deprotonated by aqueous sodium hydroxide. Real-time reaction monitoring was carried out over a period of several hours, with the reaction mixture sampled and analysed at intervals of several minutes. Product ion relative intensity is enhanced selectively in the ion mobility-selected mass spectrum, compared to mass spectrometry alone. The combined IM-MS approach has potential as a rapid and selective technique to aid pharmaceutical process control and for the elucidation of reaction mechanism.  相似文献   

19.
A new approach to obtain fragmentation information in liquid chromatography/mass spectrometry (LC/MS) studies of small molecules in complex mixtures is presented using simultaneous acquisition of exact mass at high and low collision energy, MS(E). LC/MS-TOF and LC/MS/MS-TOF are powerful tools for the analysis of complex mixtures, especially those for biological fluids allowing the elucidation of elemental composition and fragmentation information. In this example the composition of rat urine was studied using this new approach, allowing the structures of several endogenous components to be confirmed in one analytical run by the simultaneous acquisition of exact mass precursor and fragment ion data. The spectral data obtained using this new approach are comparable to those obtained by conventional LC/MS/MS as exemplified by the identification of endogenous metabolites present in rat urine.  相似文献   

20.
Comprehensive metabolome analysis using mass spectrometry (MS) often results in a complex mass spectrum and difficult data analysis resulting from the signals of numerous small molecules in the metabolome. In addition, MS alone has difficulty measuring isobars and chiral, conformational and structural isomers. When a matrix-assisted laser desorption ionization (MALDI) source is added, the difficulty and complexity are further increased. Signal interference between analyte signals and matrix ion signals produced by MALDI in the low mass region (<1500 Da) cause detection and/or identification of metabolites difficult by MS alone. However, ion mobility spectrometry (IMS) coupled with MS (IM-MS) provides a rapid analytical tool for measuring subtle structural differences in chemicals. IMS separates gas-phase ions based on their size-to-charge ratio. This study, for the first time, reports the application of MALDI to the measurement of small molecules in a biological matrix by ion mobility-time of flight mass spectrometry (IM-TOFMS) and demonstrates the advantage of ion-signal dispersion in the second dimension. Qualitative comparisons between metabolic profiling of the Escherichia coli metabolome by MALDI-TOFMS, MALDI-IM-TOFMS and electrospray ionization (ESI)-IM-TOFMS are reported. Results demonstrate that mobility separation prior to mass analysis increases peak-capacity through added dimensionality in measurement. Mobility separation also allows detection of metabolites in the matrix-ion dominated low-mass range (m/z < 1500 Da) by separating matrix signals from non-matrix signals in mobility space.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号