首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
In selected ion flow tube mass spectrometry, SIFT‐MS, analyses of humid air and breath, it is essential to consider and account for the influence of water vapour in the media, which can be profound for the analysis of some compounds, including H2CO, H2S and notably CO2. To date, the analysis of methane has not been considered, since it is known to be unreactive with H3O+ and NO+, the most important precursor ions for SIFT‐MS analyses, and it reacts only slowly with the other available precursor ion, O. However, we have now experimentally investigated methane analysis and report that it can be quantified in both air and exhaled breath by exploiting the slow O/CH4 reaction that produces CH3O ions. We show that the ion chemistry is significantly influenced by the presence of water vapour in the sample, which must be quantified if accurate analyses are to be performed. Thus, we have carried out a study of the loss rate of the CH3O analytical ion as a function of sample humidity and deduced an appropriate kinetics library entry that provides an accurate analysis of methane in air and breath by SIFT‐MS. However, the associated limit of detection is rather high, at 0.2 parts‐per‐million, ppm. We then measured the methane levels, together with acetone levels, in the exhaled breath of 75 volunteers, all within a period of 3 h, which shows the remarkable sample throughput rate possible with SIFT‐MS. The mean methane level in ambient air is seen to be 2 ppm with little spread and that in exhaled breath is 6 ppm, ranging from near‐ambient levels to 30 ppm, with no significant variation with age and gender. Methane can now be included in the wide ranging analyses of exhaled breath that are currently being carried out using SIFT‐MS. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
The reactions of carbon dioxide, CO2, with the precursor ions used for selected ion flow tube mass spectrometry, SIFT‐MS, analyses, viz. H3O+, NO+ and O, are so slow that the presence of CO2 in exhaled breath has, until recently, not had to be accounted for in SIFT‐MS analyses of breath. This has, however, to be accounted for in the analysis of acetaldehyde in breath, because an overlap occurs of the monohydrate of protonated acetaldehyde and the weakly bound adduct ion, H3O+CO2, formed by the slow association reaction of the precursor ion H3O+ with CO2 molecules. The understanding of the kinetics of formation and the loss rates of the relevant ions gained from experimentation using the new generation of more sensitive SIFT‐MS instruments now allows accurate quantification of CO2 in breath using the level of the H3O+CO2 adduct ion. However, this is complicated by the rapid reaction of H3O+CO2 with water vapour molecules, H2O, that are in abundance in exhaled breath. Thus, a study has been carried out of the formation of this adduct ion by the slow three‐body association reaction of H3O+ with CO2 and its rapid loss in the two‐body reaction with H2O molecules. It is seen that the signal level of the H3O+CO2 adduct ion is sensitively dependent on the humidity (H2O concentration) of the sample to be analysed and a functional form of this dependence has been obtained. This has resulted in an appropriate extension of the SIFT‐MS software and kinetics library that allows accurate measurement of CO2 levels in air samples, ranging from very low percentage levels (0.03% typical of tropospheric air) to the 6% level that is about the upper limit in exhaled breath. Thus, the level of CO2 can be traced through single time exhalation cycles along with that of water vapour, also close to the 6% level, and of trace gas metabolites that are present at only a few parts‐per‐billion. This has added a further dimension to the analysis of major and trace compounds in breath using SIFT‐MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
4.
We describe how selected ion flow tube mass spectrometry (SIFT-MS) can be used to determine the absolute humidity of air, breath and liquid headspace samples. This involves the determination of the relative count rates of the H3O+ ions and those H3O+.(H2O)(1,2,3) hydrate ions that inevitably form in the helium carrier gas when humid samples are being analysed by SIFT-MS using H3O+ precursor ions. This requires an understanding of the kinetics of hydrated hydronium ion formation, the involvement of mass discrimination in the analytical quadrupole mass spectrometer and the decreased diffusive loss of the heavier hydrates along the flow tube. Thus, we show that the humidity of breath and liquid headspace samples, typically at the few percent level, can be directly obtained on-line to the SIFT-MS instrument along with the concentrations of trace gases, which are present at much lower levels. We emphasise the value of parallel humidity measurements in ensuring good real-time sampling of breath and liquid headspace and the value of such measurements to trace gas analysis using SIFT-MS.  相似文献   

5.
Selected ion flow tube mass spectrometry (SIFT-MS) has been used to carry out a pilot parallel study on five volunteers to determine changes occurring in several trace compounds present in exhaled breath and emitted from skin into a collection bag surrounding part of the arm, before and after ingesting 75 g of glucose in the fasting state. SIFT-MS enabled real-time quantification of ammonia, methanol, ethanol, propanol, formaldehyde, acetaldehyde, isoprene and acetone. Following glucose ingestion, blood glucose and trace compound levels were measured every 30 min for 2 h. All the above compounds, except formaldehyde, were detected at the expected levels in exhaled breath of all volunteers; all the above compounds, except isoprene, were detected in the collection bag. Ammonia, methanol and ethanol were present at lower levels in the bag than in the breath. The aldehydes were present at higher levels in the bag than in breath. The blood glucose increased to a peak about 1 h post-ingestion, but this change was not obviously correlated with temporal changes in any of the compounds in breath or emitted by skin, except for acetone. The decrease in breath acetone was closely mirrored by skin-emitted acetone in three volunteers. Breath and skin acetone also clearly change with blood glucose and further work may ultimately enable inferences to be drawn of the blood glucose concentration from skin or breath measurements in type 1 diabetes.  相似文献   

6.
Selected ion flow tube mass spectrometry, SIFT-MS, has been used to determine the repeatability of the analysis of volatile metabolites within the breath of healthy volunteers, with emphasis on the influence of sampling methodology. Baseline instrument specific coefficients of variability for examined metabolites were as follows: acetone (1%), ammonia (1%), isoprene (2%), propanol (6%), ethanol (7%), acetic acid (7%), and hydrogen cyanide (19%). Metabolite concentration and related product ion count rate were identified as strong determinants of measurement variation. With the exception of ammonia, an orally released metabolite, variability in repeated on-line breath analysis tended to be lower for metabolites of systemic origin. Standardization of sampling technique improved the repeatability of the analysis of selected metabolites. Off-line (bag) alveolar breath sampling, as opposed to mixed (whole) breath sampling, likewise improved the repeatability of the analysis of all metabolites investigated, with the exception of acetic acid. We conclude that SIFT-MS analysis of common volatile metabolites within the breath of healthy volunteers is both reliable and repeatable. For selected metabolites, the finding that repeatability is improved through modification of sampling methodology may have implications in terms of future recommended practices.  相似文献   

7.
Selected ion flow tube mass spectrometry, (SIFT-MS), is a technique for simultaneous real-time quantification of several trace gases in air and exhaled breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas, using H(3)O(+), NO(+) and O(2)(+) reagent (precursor ions). Reactions between the precursor ions and the trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream mass spectrometer. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT-MS down to parts-per-billion (ppb) levels, obviating sample collection into bags or onto traps. Calibration using chemical standards is not required, as the concentrations are calculated using the known reaction rate constants and measured flow rates and pressures. SIFT-MS has been used for many pilot investigations in several areas of research, especially as a non-invasive breath analysis tool to investigate physiological processes in humans and animals, for clinical diagnosis and for therapeutic monitoring. Examples of the results obtained from several such studies are outlined to demonstrate the potential of SIFT-MS for trace gas analysis of air, exhaled breath and the headspace above liquids.  相似文献   

8.
We describe a method by which the concentrations of volatile compounds in the headspace of their dilute aqueous solutions in sealed containers can be determined using on-line selected ion flow tube mass spectrometry (SIFT-MS). Thus, the changing number density of the molecules of the volatile compound in the carrier gas of the SIFT-MS instrument is described in terms of its changing flow rate as the pressure in the sealed container decreases during the sampling procedure. It is shown that the best analytical procedure is to determine the mean concentration of the trace gas in the liquid headspace over a given sampling time and relate this to the required concentration, which is the initial equilibrium concentration established before the pressure in the sealed container reduces significantly. To test the validity of this analytical approach, the headspace concentrations of acetaldehyde, ethanol and acetone above aqueous solutions of known concentrations have been determined. Hence, the Henry's Law constants for these compounds have been determined and found to agree with the published values. The confirmation of the quality of this sampling methodology combined with SIFT-MS for the analysis of volatile compounds in liquid headspace paves the way for the rapid analyses of biological liquids such as urine and serum for clinical diagnosis and physiological monitoring.  相似文献   

9.
The objective of this study is the measurement of leukotriene B7 (LTB4), a potent inflammatory mediator, in exhaled breath condensate by using liquid chromatography/mass spectrometry (LC/MS and LC/MS/MS). Condensation of exhaled breath is a non-invasive method to collect airway secretions. Deuterated (d4)-LTB4 was used as internal standard. The MS and MS/MS behavior of LTB4 and LTB4-d4 was studied by electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in both positive and negative ion polarity mode. Preliminary results show that monitoring negative ions in ESI mode has the best sensitivity for both LTB4 and LTB4-d4. Therefore, negative ESI was chosen, and the [M-H]- ions at m/z 335 and 339 were selected for quantification. The lower limit of quantification for LTB4, expressed as the lowest point of the calibration curve, was 100 pg/mL. Using this technique, we measured LTB4 in exhaled breath condensate in two healthy subjects, four asthmatic patients on anti-inflammatory treatment, and four asthmatic patients who were not on anti-inflammatory drugs. Exhaled LTB4 concentrations were detected only in asthmatic patients who were not on anti-inflammatory therapy. This method is potentially useful for non-invasive assessment of airway inflammation, but the sensitivity of the technique needs to be improved.  相似文献   

10.
11.
Selected ion flow tube mass spectrometry, SIFT-MS, has been used to investigate if absolute levels of trace compounds in the headspace of ethanol/water vapour mixture can be quantified. This case study was directed towards the analysis of methylamine in distilled ethanol of agricultural origin because of its relevance to quality control legislation in the distillery industry. This has required a detailed study of the ion chemistry occurring – initiated by H3O+ precursor ions – when ethanol/water vapour mixtures are introduced into the H3O+/helium carrier gas swarm and has resulted in the construction of a full scheme of the complex ionic reactions that occur. It has been found that under the SIFT-MS flow reactor conditions (He pressure 130 Pa and temperature 299 K) the terminating ions of the several parallel and sequential reactions that occur are the proton bound ethanol clusters ions, C2H5OH2+(C2H5OH)n, with n = 1,2,3, proton bound trimer (n = 2) being the dominant species. These ethanol cluster ions can be used as precursor (reagent) ions for the chemical ionisation of the methylamine present in the ethanol/water vapour, which produces two characteristic product ions CH3NH2H+(C2H5OH)1,2 that are used for the methylamine analysis. The ratio of the product ion count rate to the precursor ion count rate is used in an analogous way to the routinely used for SIFT-MS analyses to quantify the methylamine concentration. The results of calibration experiments show that using SIFT-MS it is possible to quantify methylamine in liquid ethanol/water mixtures at levels of 0.1 mg/L or greater.  相似文献   

12.
Infection by Pseudomonas aeruginosa (PA) is a major cause of morbidity and mortality in patients with cystic fibrosis (CF). Breath analysis could potentially be a useful diagnostic of such infection, and analyses of volatile organic compounds (VOCs) emitted from PA cultures are an important part of the search for volatile breath markers of PA lung infection. Our pilot experiments using solid‐phase microextraction, SPME and gas chromatography/mass spectrometric (GC/MS) analyses of volatile compounds produced by PA strains indicated a clear presence of methyl thiocyanate. This provided a motivation to develop a method for real‐time online quantification of this compound by selected ion flow tube mass spectrometry, SIFT‐MS. The kinetics of reactions of H3O+, NO+ and O2+? with methyl thiocyanate at 300 K were characterized and the characteristic product ions determined (proton transfer for H3O+, rate constant 4.6 × 10–9 cm3 s–1; association for NO+, 1.7 × 10–9 cm3 s–1 and nondissociative charge transfer for O2+?, 4.3 × 10–9 cm3 s–1). The kinetics library was extended by a new entry for methyl thiocyanate accounting for overlaps with isotopologues of hydrated hydronium ions. Solubility of methyl thiocyanate in water (Henry's law constant) was determined using standard reference solutions and the linearity and limits of detection of both SIFT‐MS and SPME‐GC/MS methods were characterized. Thirty‐six strains of PA with distinct genotype were cultivated under identical conditions and 28 of them (all also producing HCN) were found to release methyl thiocyanate in headspace concentrations greater than 6 parts per billion by volume (ppbv). SIFT‐MS was also used to analyze the breath of 28 children with CF and the concentrations of methyl thiocyanate were found to be in the range 2–21 ppbv (median 7 ppbv). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
14.
A selected ion flow tube mass spectrometry (SIFT-MS) study of the reactions of H3O+, NO+ and O2+* ions with the ketones (M) 2-heptanone, 2-octanone, 2-nonanone, 2-undecanone and 2-aminoacetophenone has been conducted in preparation for studies of volatile emissions from bacteria. The H3O+ reactions all proceed rapidly via exothermic proton transfer, producing only MH+ ions that form their monohydrates when water vapour is present in the helium carrier gas. The O2+* reactions proceed rapidly via dissociative charge transfer producing parent cations M+* and some fragment ions. The NO+ reactions form the NO+M adduct ions at rates which are dependent on the pressure of the helium carrier gas. Combining the present NO+ kinetic data with those available from previous SIFT studies, the phenomenon of charge transfer complexing is clearly demonstrated. This results in adduct formation in these NO+/ketone reactions at or near the collisional rate. SIFT-MS spectra are presented to illustrate the simplicity of SIFT-MS analysis of ketones using both H3O+ and NO+ precursor ions.  相似文献   

15.
16.
Polyamines are a class of aliphatic compounds which include putrescine, cadaverine, spermine and spermidine. They are involved in a variety of cellular processes and have been implicated in a number of different pathophysiological mechanisms. Polyamines are volatile compounds having a distinctive odour normally perceived as being unpleasant. The measurement of their abundance has, however, been restricted to compounds present in the aqueous phase. Using selected ion flow tube mass spectrometry (SIFT‐MS) we have shown that the polyamines react with the ions H3O+, NO+ and O to form distinctive product ions allowing their levels to be quantified in the vapour phase. The low volatility of spermine did not allow extensive analysis of this compound by SIFT‐MS while the adherent properties of cadaverine and putrescine required the use of PTFE transfer lines and couplers. Our data suggested the presence of cadaverine and putrescine in both oral air and the headspace of putrefying bovine muscle, while product ions corresponding to putrescine and spermidine were found in the headspace of human semen. SIFT‐MS therefore appears to be a practical means of measuring vapour‐phase polyamine levels, having applications in biology, medicine and dentistry, and food science. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A study has been carried out, involving three healthy volunteers, of the ammonia levels in breath exhaled via the mouth and via the nose and in the static oral cavity using on-line, selected ion flow tube mass spectrometry (SIFT-MS), obviating the problems associated with sample collection of ammonia. The unequivocal conclusion drawn is that the ammonia appearing in the mouth-exhaled breath of the three volunteers is largely generated in the oral cavity and that the ammonia originating at the alveolar interface in the lungs is typically at levels less than about 100 parts-per-billion, which is a small fraction of the total breath ammonia. This leads to the recommendation that exhaled breath analyses should focus on nose-exhaled breath if the objective is to use breath analysis to investigate systemic, metabolic disease.  相似文献   

18.
We report a fast, sensitive, real-time method to measure monobromamine, monochloramine and dichloramine using selected ion flow tube mass spectrometry (SIFT-MS). Relative rate coefficients and product distributions are reported for the reagent ions H3O+ and O2 +. Rapid reactions with the haloamines were observed with H3O+ and O2 + but no fast reaction was found with NO+. A slow reaction between NO+ and dichloramine was observed. We demonstrate the feasibility of determining these compounds in a single human breath for which the limit of detection is approaching 10 parts per billion (ppb). We also report preliminary measurements of these compounds in the breath of individuals where the concentrations of bromamine and chloramine ranged from 10 to 150 ppb.  相似文献   

19.
In this paper we compare the amounts of ethanol in breath and in blood after ingestion of whisky using analysis by selected ion flow tube mass spectrometry (SIFT-MS). Blood ethanol concentrations were also obtained using standard hospital forensic procedures for blood alcohol analyses. We demonstrate the quantitative nature of SIFT-MS analysis by correlating the observed alcohol content of the headspace above 5-mL amounts of venous blood and aqueous solution to which known trace amounts of alcohol have been added. This procedure provides a Henry's Law coefficient for ethanol in aqueous solution at 298 +/- 3 K of 209 +/- 7 mol/kg*bar. We also demonstrate that measurement of the ethanol concentration in the alveolar portion of a single breath using the SIFT-MS technique gives an accurate measure of blood alcohol and could obviate the need for blood samples in forensic processing. The storage performance of breath samples in Mylar bags with a volume greater than 1 L has been shown to maintain the mixture integrity for ethanol but not for some other species.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号