首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Performance of a 241Am-Be neutron source-based and 2.8 MeV neutrons-based moisture measurement setups have been compared using Monte Carlo simulation. In the setup fast neutrons transmitted through the sample were detected by a fast neutron detector, which was placed behind a massive long double truncated collimator. The setup geometry was optimized to detect maximum effect of 1–7 wt.% moisture on the neutron intensity transmitted through the sample. The yield of neutrons transmitted through concrete, coal, wood and soil samples containing 1–7 wt.% moisture was calculated for 2.8 MeV neutrons and neutrons from an 241Am-Be source. The slopes of the fast neutron intensities transmitted through the samples vs. their moisture contents are very sensitive to the neutron energy and the sample composition. Higher slopes have been observed for the samples with larger bulk density. The slopes of fast neutron yield show dependence on the incident neutron energy. Larger slopes have been observed for neutrons with samller energy. Due to the overall large slopes of the transmitted intensity data of the samples for 2.8 MeV neutrons, it is expected to achieve better sensitivity in moisture measurements for a 2.8 MeV neutrons based moisture setup.  相似文献   

2.
Effect of neutron source-moderator geometry has been studied on the performance of a thermal neutron capture-based prompt gamma neutron activation analysis (PGNAA) setup. In the study prompt gamma-ray and thermal neutron yield was calculated for various positions of the neutron source inside 3–10 cm long high density polyethylene moderators. The study has been carried out for a Portland cement sample using Monte Carlo calculations. The maximum yields of the thermal neutrons and prompt gamma-rays have been observed for a neutron source at a distance of 1 cm from the sample. The maximum yield of the 1.94 and 6.42 MeV prompt gamma-ray from a Portland cement sample has been observed for moderators having length equal to or greater than 7 cm. The yield of both gamma rays is 2.57 times higher than the previously reported value for a PGNAA setup with the source placed outside a 5 cm thick moderator. The higher yield of gamma rays will result in higher sensitivity of the PGNAA setup.  相似文献   

3.
A Prompt Gamma Ray Neutron Activation Analysis (PGNAA) system, incorporating an isotopic neutron source has been simulated using the MCNPX Monte Carlo code. In order to improve the signal to noise ratio different collimators and a filter were placed between the neutron source and the object. The effect of the positioning of the neutron beam and the detector relative to the object has been studied. In this work the optimisation procedure is demonstrated for boron. Monte Carlo calculations were carried out to compare the performance of the proposed PGNAA system using four different neutron sources (241Am/Be, 252Cf, 241Am/B, and DT neutron generator). Among the different systems the 252Cf neutron based PGNAA system has the best performance.  相似文献   

4.
Journal of Radioanalytical and Nuclear Chemistry - A PGNAA set-up consisting of a 241Am-Be neutron source and a HPGe detector was proposed to determine rare-earth elements in leachate during...  相似文献   

5.
A thermal neutron capture-based Prompt Gamma ray Activation Analysis setup has been designed to analyze the elemental concentration of environmental bulk samples using a D(d,n) reaction-based portable neutron generator. The performance of the setup was tested through mercury concentration measurements in Hg-contaminated water samples using a large volume cylindrical bismuth germinate (BGO) gamma ray detector. Excellent agreement of experimental count rate of 2.64, 3.19 + 3.29 and 4.67–5.05 MeV Hg prompt gamma rays with theoretical count rate obtained through Monte Carlo simulations, indicates excellent performance of the newly designed portable neutron generator-based PGNAA setup.  相似文献   

6.
Material analysis with prompt gamma neutron activation analysis (PGNAA) requires a proper geometrical arrangement for equipments in laboratory. Application of PGNAA in analysis of biological samples, due to small size of sample, needs attention to the dimension of neutron beam. In our work, neutron source has been made of 241Am–Be type. Activity of 241Am was 20 Ci which lead to neutron source strength of 4.4 × 107 neutrons per second. Water has been considered as the basic shielding material for the neutron source. The effect of various concentration of boric acid in the reduction of intensity of fast and thermal components of the neutron beam and gamma ray has been investigated. Gamma ray is produced by (α, n) reaction in Am–Be source (4.483 MeV), neutron capture by hydrogen (2.224 MeV), and neutron capture by boron (0.483 MeV). Various types of neutron and gamma ray dosimeters have been employed including BF3 and NE-213 detectors to detect fast and thermal neutrons. BGO scintillation detector has been used for gamma ray spectroscopy. It is shown that the gamma and neutron radiation dose due to direct beam is of the same magnitude as the dose due to radiation scattered in the laboratory ambient. It is concluded that 14 kg boric acid dissolved in 1,000 kg water is the optimum solution to surround the neutron source. The experimental results have been compared with Monte Carlo simulation.  相似文献   

7.
Monte Carlo calculations were carried out to study the dependence of γ-ray yield on the bulk density and moisture content of a sample in a thermal-neutron capture-based prompt gamma neutron activation analysis (PGNAA) setup. The results of the study showed a strong dependence of the γ-ray yield upon the sample bulk density. An order of magnitude increase in yield of 1.94 and 6.42 MeV prompt γ-rays from calcium in a Portland cement sample was observed for a corresponding order of magnitude increase in the sample bulk density. On the contrary the γ-ray yield has a weak dependence on sample moisture content and an increase of only 20% in yield of 1.94 and 6.42 MeV prompt γ-rays from calcium in the Portland cement sample was observed for an order of magnitude increase in the moisture content of the Portland cement sample. A similar effect of moisture content has been observed on the yield of 1.167 MeV prompt γ-rays from chlorine contaminants in Portland cement samples. For an order of magnitude increase in the moisture content of the sample, a 7 to 12% increase in the yield of the 1.167 MeV chlorine γ-ray was observed for the Portland cement samples containing 1 to 5 wt.% chlorine contaminants. This study has shown that effects of sample moisture content on prompt γ-ray yield from constituents of a Portland cement sample are insignificant in a thermal-neutrons capture-based PGNAA setup.  相似文献   

8.
An activation analysis facility based on an isotopic neutron source (185 GBq 241Am/Be) which can perform both prompt and cyclic activation analysis on bulk samples, has been used for more than 20 years in many applications including 'in vivo' activation analysis and the determination of the composition of bio-environmental samples, such as, landfill waste and coal. Although the comparator method is often employed, because of the variety in shape, size and elemental composition of these bulk samples, it is often difficult and time consuming to construct appropriate comparator samples for reference. One of the obvious problems is the distribution and energy of the neutron flux in these bulk and comparator samples. In recent years, we have attempted to adopt the absolute method based on a monostandard and to make calculations using a Monte Carlo code (MCNP4C2) to explore this further. In particular, a model of the irradiation facility has been made using the MCNP4C2 code in order to investigate the factors contributing to the quantitative determination of the elemental concentrations through prompt gamma neutron activation analysis (PGNAA) and most importantly, to estimate how the neutron energy spectrum and neutron dose vary with penetration depth into the sample. This simulation is compared against the scattered and transmitted neutron energy spectra that are experimentally and empirically determined using a portable neutron spectrometry system. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

9.
The element content in rock sample can be determined by prompt gamma ray activation analysis technology. The neutron distributions under the conditions with different moderating materials, moderator size and distance from neutron source to lead-out hole were simulated using Monte Carlo method, and then the optimal structure parameters to get the highest thermal neutron flux was obtained. The PGNAA system with optimal parameters based on 252Cf neutron source was founded. In addition, the rock and element standard samples were irradiated by thermal neutron in this system. Moreover, the element content was calculated by processing gamma ray spectroscopy recorded, and it is in agreement with result of XRF method.  相似文献   

10.
An instrumental thermal neutron activation analysis facility based, on a 16 Ci241 Am–Be source, a high resolution -ray spectrometry setup and a PC-based data acquisition system at KFUPM is described. The thermal neutron flux distribution was determined from the induced activities of high purity indium foils. The absolute thermal neutron flux was calculated from the activities of bare and cadmium-covered gold foils at a position of 3 cm from the soource at which the flux reaches a maximum. The facility tests were carried out with the determination of manganese concentrations in six types of industrially important steel samples. The result of 1.33% manganese in SS-304 steel sample was in excellent agreement with the literature value. The method is nondestructive, economical and ideal for bulk analysis.  相似文献   

11.
A 740 GBq 241Am-Be neutron source based prompt gamma-ray activation analysis (PGAA) setup in combination with a typical coaxial n-type HPGe detector (REGe) system was used to analyze light elements like H, B, C, N, etc. The absolute full energy peak (FEP) efficiencies of the shielded REGe detector for irradiation and counting geometries and for sources with different sizes (point, ampoule and cylindrical) were measured in the 0.1–2.5 MeV energy range by utilizing calibrated sources (point, liquid and solid). 4th order polynomials were fitted to the experimental data. Efficiencies in far irradiation and counting geometries are compared.  相似文献   

12.
The CITATION code based on neutron diffusion theory is used for flux calculation inside voluminous sample in prompt gamma activation analysis with an isotopic neutron source (241Am-Be). The code used the specific parameters related to energy spectrum source, irradiation system materials (shielding, reflector, etc.), geometry and elemental composition of the sample. The flux distribution (thermal and fast) was calculated on three-dimensional geometry for the system: source, air, and polyethylene and water cylindrical sample of 125 liters. The thermal flux was calculated in series of points inside the sample, and agreed with the results obtained by measurements with good statistical uncertainty. The maximum thermal flux was measured at distance of 4.1 cm and calculated at 4.3 cm by the CITATION code. Beyond a depth of 7.2 cm, the ratio of thermal flux to fast flux increases up to twice and allows us the optimization of the detection system in the scope of in-situ PGNAA.  相似文献   

13.
Summary A setup was developed in order to determine the bitumen content in asphalt concrete by neutron reflection. The main parts of this setup are an Am-Be neutron source of 37 GBq and a 3He neutron detector. To avoid geometrical effects of the measurements, the optimum volume of the samples was determined by plotting the reflected neutron response versus the sample volume. For the calibration of the system, the American Standard Method (ASTM) was used when preparing aggregate and asphalt concrete samples. The method was then compared to the conventional chemical method by analyzing unknown samples taken from an asphalt comcrete producing plant and finally the method was assessed in terms of reproducibility, sensitivity and precision.  相似文献   

14.
The elemental analysis of Pt-Re/alumina catalysts was carried out by nondestructive and bulk neutron activation analysis. Samples were irradiated with a241Am-Be source-based as well as accelerator-based thermal neutrons and induced activities were measured by a HPGe detector with a PC-based data acquisition and analysis system. An appropriate calibration technique was established for the determination of the respective ratios of each element present in the catalysts. The technique proved to be useful for the determination of low concentrations of Pt and Re in the catalyst samples.  相似文献   

15.
Simulations show that significant improvement in imaging performance can be achieved through collimator design for thermal and fast neutron radiography with a laboratory neutron generator. The radiography facility used in the measurements and simulations employs a fully high-voltage-shielded, axial D–D neutron generator with a radio frequency driven ion source. The maximum yield of such generators is about 1010 fast neutrons per seconds (E = 2.45 MeV). Both fast and thermal neutron images were acquired with the generator and a Charge Coupled Devices camera. To shorten the imaging time and decrease the noise from gamma radiation, various collimator designs were proposed and simulated using Monte Carlo N-Particle Transport Code (MCNPX 2.7.0). Design considerations included the choice of material, thickness, position and aperture for the collimator. The simulation results and optimal configurations are presented.  相似文献   

16.
This work deals with the absolute measurement of the neutron emission rate from a 241Am–Be source by means of the manganese sulphate bath technique, which is the principal method for the absolute determination of the neutron emission rate from radionuclide neutron sources. The facility consists of a spherical container filled with an aqueous solution of manganese sulphate with a 241Am–Be neutron source placed at the center. As well known, neutrons from the source, after having been thermalized by the aqueous solution, undergo neutron capture by hydrogen, manganese, sulphur, and oxygen nuclei, thus inducing a certain activity to the solution. Subsequent gamma spectrometry measurements of 56Mn activity generated by 55Mn neutron activation allows to determine the neutron emission rate of the source, The experimental activity has involved a variety of measurement techniques and calculation procedures, ranging from neutron reactor activation to liquid scintillation counting and Monte Carlo calculations. Neutron activations of 55Mn samples has been carried out with the TRIGA reactor of the ENEA-Casaccia Research Centre, and 56Mn activated samples were subsequently characterized by liquid scintillation counting, in order to obtain reference standards for the calibration of the NaI(Tl) scintillation detectors utilized to record gamma-ray emission from 56Mn. Monte Carlo calculations, carried out by the MCNPX code, were required to calculate neutron transport within the sulphate manganese bath, in particular to determine 55Mn neutron capture probability, and (n, α) and (n, p) concurrent reactions, as well as the neutron leakage. Such a procedure has allowed to maintaining the neutron emission rate uncertainty well below 1 %. All the measurements have been carried out at the ENEA-Casaccia Research Centre by the Italian National Institute of Ionizing Radiation Metrology.  相似文献   

17.

A novel approach to estimation of neutron energy spectrum by LaBr3:Ce detector which was usually used for gamma rays measurement was presented. In this approach, energy distribution of the neutron flux was devided into several bins, and simultaneous equations of these bins were setup based on the net counts of gamma peaks induced by neutron inelastic scattering with LaBr3:Ce detector. With these equations, the neutron energy spectrum was derived by a deconvolution algorithm. This approach was tested using a 3 in.?×?3 in. LaBr3:Ce detector exposured to an 241Am-Be neutron source and proved practicable.

  相似文献   

18.
The potential for using a small, sealed tube, DT neutron generator for neutron activation analysis has been well documented but not well demonstrated, except for 14 MeV activation analysis. This paper describes the design, construction and characterization of a neutron irradiation facility incorporating a small sealed tube DT neutron generator producing 14 MeV neutrons with fluence rates of 2·108 s−1 in 4π (steady state) and 1011 s−1 in 4π (pulsed). Monte Carlo modeling using MCNP4c and McBend9 has been used to optimize the design of this facility, including the location of a thermal irradiation facility for conventional neutron activation analysis. A significant factor in designing the facility has been the requirement to conform with Ionising Radiation Regulations and the design has been optimized to keep potential radiation doses to less that 1 μSv/h at the external walls of the facility. Activation of gold foils has been used for flux characterization and the experimental results agree well with the modeling.  相似文献   

19.
A prompt gamma-ray neutron activation analysis (PGNAA) system was used to calibrate and validate a Monte Carlo model as a proof of principle for the quantification of chlorine in soil. First, the response of an n-type HPGe detector to point sources of 60Co and 152Eu was determined experimentally and used to calibrate an MCNP4a model of the detector. The refined MCNP4a detector model can predict the absolute peak detection efficiency within 12% in the energy range of 120–1400 keV. Second, a PGNAA system consisting of a light-water moderated 252Cf (1.06 g) neutron source, and the shielded and collimated HPGe detector was used to collect prompt gamma-ray spectra from Savannah River Site (SRS) soil spiked with chlorine. The spectra were used to calculate the minimum detectable concentration (MDC) of chlorine and the prompt gamma-ray detection probability. Using the 252Cf based PGNAA system, the MDC for Cl in the SRS soil is 4400 g/g for an 1800-second irradiation based on the analysis of the 6110 keV prompt gamma-ray. MCNP4a was used to predict the PGNAA detection probability, which was accomplished by modeling the neutron and gamma-ray transport components separately. In the energy range of 788 to 6110 keV, the MCNP4a predictions of the prompt gamma-ray detection probability were generally within 60% of the experimental value, thus validating the Monte Carlo model.  相似文献   

20.
A prompt gamma neutron activation analysis (PGAA) setup installed at ANRTC has been used to analyze boron. It consists of a 22.6% REGe detector and a 740 GBq 241Am-Be neutron source moderated with water and paraffin. At the sample irradiation position, the thermal neutron fluence rate measured was 2.36·104 n·m–2· s–1 and the corresponding Cd-ratio was 22 for gold monitor. The absolute detection efficiency in the range of 120–1500 keV was determined using 152Eu standard solution. The sensitivity and detection limit for standard boric acid samples has been determined. The boron content in boric acid prepared from Turkish borate ores is measured to be 15.91±0.46% wt.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号