首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lan L  Hu B  Yu C 《Journal of chromatography. A》2010,1217(45):7003-7009
An organic-inorganic hybrid titania-hydroxy-terminated silicone oil (titania-OH-TSO) stir bar coating was prepared by sol-gel method. The extraction performance of titania-OH-TSO coated stir bar was evaluated and compared with poly(dimethysiloxane) (PDMS), poly(dimethysiloxane)-divinylbenzene (PDMS-DVB), poly(dimethysiloxane)-β-cyclodextrin (PDMS-β-CD) and C(18) coated stir bar with five polar drugs of abuse including amphetamine (PA), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and ketamine (Ke) as the model analytes. The experimental results revealed that the titania-OH-TSO coated stir bar exhibited highly pH-resistant ability, good preparation reproducibility, superior selectivity and high extraction efficiency for the target compounds. Based on this fact, a new method of titania-OH-TSO coated stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet visible (UV) detection was developed for the analysis of five drugs of abuse in urine samples. The factors affecting the extraction efficiency of SBSE such as sample pH, desorption solvent, sample volume, extraction time, desorption time, stirring rate and ionic strength were investigated and the optimal extraction conditions were established. Under the optimized conditions, the limits of detection (LODs) for titania-OH-TSO coated SBSE-HPLC-UV determination of five polar drugs of abuse were in the range of 2.3-9.1 μg/L with relative standard deviations (RSDs) ranging from 7.3 to 8.9% (c=300 μg/L, n=6), and all of the target compounds exhibited good linearity over a concentration range of 30-3000 μg/L. The developed method was applied to the determination of amphetamines and Ke in urine samples of drug abusers with satisfactory results.  相似文献   

2.
This study describes the development of a new method for determining p-hydroxybenzoic esters (parabens) in house dust. This optimised method was based on the pressurised hot water extraction (PHWE) of house dust, followed by the acetylation of the extracted parabens, stir bar sorptive extraction (SBSE) with a polydimethylsiloxane stir bar, and finally analysis using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The combination of SBSE and PHWE allows the analytes to be preconcentrated and extracted from the aqueous extract in a single step with minimal manipulation of the sample. Furthermore the in situ acetylation of parabens prior to SBSE improved their extraction efficiency and their GC-MS signal. The method showed recoveries of between 40 and 80%, good linearity, repeatability and reproducibility (<10% RSD, at 100 ng g(-1), n=5), low limits of detection (from 1.0 ng g(-1) for propyl paraben to 2.1 ng g(-1) for methyl paraben) and quantification (from 3.3 ng g(-1) for propyl paraben to 8.5 ng g(-1) for methyl paraben). The proposed method was applied to the analysis of house dust samples. All the target parabens were found in the samples. Methyl and propyl parabens were the most abundant, with concentrations up to 2440 ng g(-1) and 910 ng g(-1), respectively. The high levels of parabens found in the samples confirm the importance of determining organic contaminants in indoor environments.  相似文献   

3.
Yuling Hu 《Talanta》2010,82(2):464-4294
A novel stir bar coated with molecularly imprinted polymer (MIP) as selective extraction phase for sorptive extraction of triazine herbicides was developed. The stir bar was prepared by chemically bonding the MIP to the glass bar to improve its stability. A homogeneous and porous structure was observed on the stir bar surface. Extraction performance shows that the MIP-coated stir bar has stronger affinity to the template molecule terbuthylazine as compared with that of the reference stir bar without addition of template. Owning to the shape and structural compatibility, the obtained stir bar also demonstrated specific selectivity to the structural related-compounds of nine triazines, and thus can be applied to simultaneous determination of these compounds from complex samples coupled with high performance liquid chromatography. Four complex samples with different matrix, including rice, apple, lettuce and soil were used to evaluate this proposed method. The limits of detection obtained are in the range of 0.04-0.12 μg L−1, and the recoveries for the spiked rice, apple, lettuce and soil samples were 80.8-107.7%, 80.6-107.8%, 72.0-109.8% and 89.0-114.8% with RSD from 1.2 to 7.9%, respectively. Moreover, this MIP-coated stir bar was firm, durable and can be prepared simply and reproducibly. The developed coating method would be useful to prepare a range of selective stir bars in order to extend the applicability of stir bar sorptive extraction (SBSE) in complex sample analysis.  相似文献   

4.
A spiral stir bar was proposed by using stainless steel spring as the extraction phase carrier to avoid the extraction phase friction and increase the amount of extraction phase for improving extraction efficiency. The extraction phase is filled in the cavity of the spring, resulting in a larger amount of the extraction phase than that conventionally coated on glass stir bar or stainless steel wire. Polyaniline‐polydimethylsiloxane sol‐gel packed spiral stir bar was prepared and evaluated for the extraction of five estrogens. The prepared spiral stir bar presented good extraction efficiency/preparation reproducibility and long lifetime (more than 150 reused times) for target estrogens. Based on it, a method of spiral stir bar sorptive extraction combined with high performance liquid chromatography coupled with ultra‐violet detection was developed for the analysis of trace estrogens in environmental and food samples. The detection limit for five estrogens was 0.11–.31 µg/L, with the enrichment factors of 83.0–118‐fold (maximal enrichment factor: 200‐fold). The reproducibility evaluated with each estrogen of 5 µg/L (n = 5) was 5.8–8.9%. The method was successfully applied for the determination of estrogens in environmental water and animal‐derived food samples.  相似文献   

5.
A method for mercury analysis and speciation in drinking water was developed, which involved stir bar sorptive extraction (SBSE) with in situ propyl derivatization and thermal desorption (TD)-GC-MS. Ten millilitre of tap water or bottled water was used. After a stir bar, pH adjustment agent and derivatization reagent were added, SBSE was performed. Then, the stir bar was subjected to TD-GC-MS. The detection limits were 0.01 ng mL(-1) (ethylmercury; EtHg), 0.02 ng mL(-1) (methylmercury; MeHg), and 0.2 ng mL(-1) (Hg(II) and diethylmercury (DiEtHg)). The method showed good linearity and correlation coefficients. The average recoveries of mercury species (n=5) in water samples spiked with 0.5, 2.0, and 6.0 ng mL(-1) mercury species were 93.1-131.1% (RSD<11.5%), 90.1-106.4% (RSD<7.8%), and 94.2-109.6% (RSD<8.8%), respectively. The method enables the precise determination of standards and can be applied to the determination of mercury species in water samples.  相似文献   

6.
A new monolithic coating based on vinylpyrrolidone‐ethylene glycol dimethacrylate polymer was introduced for stir bar sorptive extraction. The polymerization step was performed using different contents of monomer, cross‐linker and porogenic solvent, and the best formulation was selected. The quality of the prepared vinylpyrrolidone‐ethylene glycol dimethacrylate stir bars was satisfactory, demonstrating good repeatability within batch (relative standard deviation < 3.5%) and acceptable reproducibility between batches (relative standard deviation < 6.0%). The prepared stir bar was utilized in combination with ultrasound‐assisted liquid desorption, followed by high‐performance liquid chromatography with ultraviolet detection for the simultaneous determination of diazepam and nordazepam in human plasma samples. To optimize the extraction step, a three‐level, four‐factor, three‐block Box–Behnken design was applied. Under the optimum conditions, the analytical performance of the proposed method displayed excellent linear dynamic ranges for diazepam (36–1200 ng/mL) and nordazepam (25–1200 ng/mL), with correlation coefficients of 0.9986 and 0.9968 and detection limits of 12 and 10 ng/mL, respectively. The intra‐ and interday recovery ranged from 93 to 106%, and the relative standard deviations were less than 6%. Finally, the proposed method was successfully applied to the analysis of diazepam and nordazepam at their therapeutic levels in human plasma. The novelty of this study is the improved polarity of the stir bar coating and its application for the simultaneous extraction of diazepam and its active metabolite, nordazepam in human plasma sample. The method was more rapid than previously reported stir bar sorptive extraction techniques based on monolithic coatings, and exhibited lower detection limits in comparison with similar methods for the determination of diazepam and nordazepam in biological fluids.  相似文献   

7.
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction (SBSE) for the analysis of 51 persistent organic pollutants including organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and polybrominated diphenylethers (PBDEs) in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, solvent volume, mass of soil, and extraction time, and the partitioning from the solvent/water mixture to the PDMS were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of SBSE for 14 h at 900 rpm. The stir bars were analyzed by thermal desorption-GC-mass spectometry (TD-GC-MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials (CRMs). The main advantage of this method resides in the fact that a small amount of a nontoxic solvent (methanol) is needed for the extraction of only 1 g of solid sample allowing LODs ranging from 0.01 to 2.0 microg/kg. Repeatability and reproducibility variations were lower than 20% for all investigated compounds. Results of the CRMs verify the high accuracy of this method.  相似文献   

8.
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction for the analysis of phenolic organic pollutants including chlorophenols, bisphenol-A, 4-tert-octylphenol and 4-nonylphenol in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, extraction time, and the partitioning from the solvent/water mix to poly(dimethylsiloxane) (PDMS) were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of stir bar sorptive extraction with in situ derivatisation. The stir bars were analyzed by thermal desorption–gas chromatography–mass spectrometry (TD–GC–MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials and by comparing the analysis of real samples with the proposed method and a classical method using pressurized solvent extraction (PSE)–GC–MS. The main advantage of this method is a substantial solvent reduction. For the extraction of only 1 g of solid sample allowing limits of detection ranging from 0.2 to 1.7 μg kg−1 dw. Repeatability and reproducibility variation were lower than 20% for all investigated compounds. Results of the certified reference materials and the real samples verify the high accuracy of this method.  相似文献   

9.
A novel poly(phthalazine ether sulfone ketone) (PPESK) film prepared by immersion precipitation technique was coated on stir bars for sorptive extraction. Scanning electron micrographs showed that the coating has a denser porous surface (about 1 microm in thickness) with a sponge-like sublayer, and the thickness of the coating was 250 microm. The PPESK coated stir bar has high thermostability (290 degrees C) and long lifetime (50 times). The extraction properties of this stir bar were evaluated for the extraction of both polar and semi-polar analytes, including organochlorine compounds and organophosphorus pesticides. The PPESK stir bar was proved to show higher affinity towards polar compounds than that of PDMS coated stir bar and higher sample load compared with corresponding PPESK fiber. It was applied to the determination of organochlorine compounds in seawater samples and organophosphorus pesticides in juices by gas chromatographic analysis. The effect of sample matrix was evaluated at optimized condition of extraction temperature, extraction time and salt concentration. Limits of detection were in the range of 0.05-2.53 ng L(-1) for organochlorine compounds in seawater samples using electron capture detector (ECD), with precisions of less than 11% RSD. Limits of detection for organophosphorus pesticides were in the range of 0.17-2.25 ng L(-1) and 2.47-10.3 ng L(-1) in grape and peach juice, respectively, using thermionic specified detector (TSD), with precisions of less than 12% RSD and 20% RSD, respectively.  相似文献   

10.
A PDMS/poly(vinylalcohol) (PDMS/PVA) film prepared through a sol–gel process was coated on stir bars for sorptive extraction, followed by liquid desorption and large volume injection–GC–flame photometric detector (LVI–GC–FPD) for the determination of five organophosphorus pesticides (OPPs) (phorate, fenitrothion, malathion, parathion, and quinalphos) in honey. The preparation reproducibility of PDMS/PVA‐coated stir bar ranged from 4.3 to 13.4% (n = 4) in one batch, and from 6.0 to 12.6% (n = 4) in batch to batch. And one prepared stir bar can be used for more than 50 times without apparent coating loss. The significant parameters affecting stir bar sorptive extraction (SBSE) were investigated and optimized. The LODs for five OPPs ranged from 0.013 (parathion) to 0.081 μg/L (phorate) with the RSDs ranging from 5.3 to 14.2% (c = 1 μg/L, n = 6). The proposed method was successfully applied to the analysis of five OPPs in honey.  相似文献   

11.
A simple and highly sensitive method called stir bar sorptive extraction (SBSE) and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of 5-chloro-2-(2,4-dichlorophenoxy)phenol (triclosan) in river water samples, is described. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 10mL water sample and stirring is carried out for 120min at room temperature (25 degrees C) in a vial. Then, the PDMS stir bar is subjected to TD-GC-MS. The detection limit of triclosan is 5ngL(-1) (ppt). The method shows linearity over the calibration range (0.02-20mugL(-1)) and the correlation coefficient is higher than 0.997 for triclosan standard solution. The recovery of triclosan in river water samples ranges from 91.9 to 108.3% (RSD: 4.0-7.0%). This simple, accurate, sensitive, and selective analytical method may be used in the determination of trace amounts of triclosan in river water samples.  相似文献   

12.
Stir bar sorptive extraction (SBSE) in combination with thermodesorption-gas chromatography-mass spectrometry (TD-GC-MS) was applied for the determination of eight insect repellents and synergists in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 20 mL of water sample with 4 g NaCl and stirred at 1000 rpm for 180 min. Then, the stir bar was subjected to TD-GC-MS. SBSE parameters (ionic strength, presence of organic solvent and time) were optimised. Blank contamination and carryover problems were also studied. The method affords detection limits between 0.5 and 30 ng/L, except for dimethyl phthalate (DMP) (150 ng/L) due to blank contamination problems. It shows good linearity with correlation coefficients over 0.997 and reproducibility (RSD) below 20%. The extraction efficiencies were between 29% for DMP and 80% for di-n-propyl isocinchomeronate (R-326). The feasibility of the method was tested by analysing real samples such as lake water, river water and wastewater.  相似文献   

13.
Stir bar sorptive extraction (SBSE) in combination with thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) was applied for the determination of 9 UV filters in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 20 mL of water sample at pH 2 (10% MeOH) and stirred at 1000 rpm for 180 min. Then, the stir bar was subjected to TD-GC-MS. The desorption conditions (desorption temperature and desorption time) and SBSE parameters (ionic strength, pH, presence of organic solvent and time) were optimised using a full factorial design and a Box-Behnken design, respectively. The method shows good linearity (correlation coefficients >0.994) and reproducibility (RSD<16%). The extraction efficiencies were above 63% for all the compounds. Detection limits were between 0.2 and 63 ng/L. The developed method offers the ability to detect several UV filters at ultra-low concentration levels with only 20 mL of sample volume. The effectiveness of the method was tested by analysing real samples such as lake water, river water and treated wastewater. The application of the method allowed reporting the levels of UV filters in environmental water samples.  相似文献   

14.
A novel method called thermal desorption (TD) with in tube silylation followed by gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of alkylphenols (APs) in river water samples, is described. APs are extracted from river water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. The stir bar coated with polydimethylsiloxane (PDMS) is added to 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 degrees C) in the vial. Then, the PDMS stir bar is subjected to TD with in tube silylation followed by GC-MS. The detection limit is of the sub pg ml(-1) (ppt) level. The method shows good linearity and the correlation coefficients are higher than 0.99 for all analytes. The average recoveries of APs are higher than 90% (R.S.D.: 3.6-14.8%, n=6). This simple and sensitive analytical method may be used in the determination of trace amounts of APs in river water samples.  相似文献   

15.
In the present study, a stir bar coated with hydrophilic polymer based on poly(N-vinylpyrrolidone-co-divinylbenzene) was prepared for the sorptive extraction of polar compounds. The main parameters affecting the polymerisation of the coating were investigated.The new stir bar was applied successfully in stir bar sorptive extraction with liquid desorption followed by liquid chromatography–mass spectrometry in tandem with a triple quadrupole for the determination of a group of polar pharmaceuticals and personal care products (PPCPs) in environmental water matrices. Different variables affecting extraction and desorption such as agitation speed, temperature, ionic strength and extraction time were optimised. The results showed that the stir bar is able to enrich the selected analytes effectively.The developed method was applied to determine a group of PPCPs in different complex environmental samples, including river, effluent and influent waste water.  相似文献   

16.
Hu Y  Li J  Li G 《Journal of separation science》2011,34(10):1190-1197
The preparation, characteristics and application of a sorptive stir bar coated with molecularly imprinted polymer (MIP) using triadimefon as the template molecule are described here. Raw glass capillary was coated with MIP through chemical bonding. The synthesis method was effective and reproducible with the batch-to-batch RSD within 7.8%. Scanning electron micrographs of the stir bar revealed a highly porous coating with average thickness of 15 μm. The synthesized stir bar was proved to be highly stable in most of the solvent for use. Extraction performance showed the fabricated stir bar has excellent molecular recognition abilities for triadimefon and the structure-related compounds, such as triadimenol, diniconazole, flutriafol, hexaconazole, tebuconazole, paclobutrazol and uniconazole, and thus can be applied for simultaneous determination of these triazole fungicides from complex samples by coupling with high-performance liquid chromatography. The variables that influence extraction were optimized with 10.0 μg/L standard solutions of triazole fungicides, and the analytical method was established for the determination of triazole fungicides in soil. The detection limits were in the range of 0.14-0.34 μg/L, and the recoveries were from 86.7 to 114.6% for spiked soil sample.  相似文献   

17.
A new method using the extraction and preconcentration capabilities of stir bar sorptive extraction, combined with high-resolution gas chromatography and mass spectrometry, was developed for the determination of five selected endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol, and 17α-ethinylestradiol) in water. In situ derivatization to transform the phenolic compounds into lipophilic and volatile analytes was carried out with acetic anhydride. Two different methods of headspace derivatization to further improve the chromatographic properties of 17β-estradiol and 17α-ethinylestradiol were developed and compared. The optimized method provided good sensitivity (limits of quantitation 1.2–2.6 ng), repeatability (relative standard deviation 2–9%), and reproducibility (relative standard deviation 10–17%). Passive sampling by means of polar organic chemical integrative samplers was applied to monitor river waters used as supply sources for drinking water treatment plants in the Liguria region of Italy. The analytes showed a different distribution at the three sites considered; bisphenol A proved to be the most abundant, ranging from 185 to 459 ng per sampler.  相似文献   

18.
A novel extraction procedure for stir bar sorptive extraction (SBSE) termed sequential SBSE was developed. Compared to conventional SBSE, sequential SBSE provides more uniform enrichment over the entire polarity/volatility range for organic pollutants at ultra-trace levels in water. Sequential SBSE consists of a SBSE performed sequentially on a 5-mL sample first without modifier using one stir bar, then on the same sample after addition of 30% NaCl using a second stir bar. The first extraction with unmodified sample is mainly targeting solutes with high Kow (logKow>4.0), the second extraction with modified sample solution (containing 30% NaCl) is targeting solutes with low and medium Kow (logKow<4.0). After extraction the two stir bars are placed in a single glass desorption liner and are simultaneously desorbed. The desorbed compounds were analyzed by thermal desorption and gas chromatography-mass spectrometry (TD-GC-MS). Recovery of model compounds consisting of 80 pesticides (organochlorine, carbamate, organophosphorus, pyrethroid, and others) for sequential SBSE was evaluated as a function of logKow (1.70-8.35). The recovery using sequential SBSE was compared with those of conventional SBSE with or without salt addition (30% NaCl). The sequential approach provided very good recovery in the range of 82-113% for most of the solutes, and recovery less than 80% for only five solutes with low Kow (logKow<2.5), while conventional approaches (with or without salt addition) showed less than 80% recovery for 23 and 41 solutes, respectively. The method showed good linearity (r2>0.9900) and high sensitivity (limit of detection: <10ngL(-1)) for most of the model compounds even with the scan mode in the MS. The method was successfully applied to screening of pesticides at ngL(-1) level in river water samples.  相似文献   

19.
Acidified subcritical water is proposed for the continuous extraction of metals (namely, lead, copper, cadmium, arsenic, selenium and mercury) from soils prior to: (a) continuous derivatisation (by hydride formation for As and Se, and cold vapour formation for Hg) and determination by atomic fluorescence; and (b) determination by Graphite Furnace-Atomic Absorption Spectrometry for Pb, Cu and Cd. Soil samples (5 g) were subjected to 90-min dynamic extraction with water modified with 4% (v/v) HNO(3) at 200 degrees C and 30 bar. A univariate optimisation of the variables related to derivatisation (for As, Se and Hg) and detection (for all of them), and a multifactorial optimisation of the variables affecting the continuous extraction step were performed. A kinetics study of the extraction process was performed in order to control the lowering of metals in the soil. The method was compared with the EPA-3051 reference method. The good reproducibility of the method, together with its safety and low cost, make it a good alternative for the demetalisation of contaminated soil.  相似文献   

20.
Stir‐bar sorptive extraction is based on the partitioning of target analytes between the sample (mostly aqueous‐based liquid samples) and a stationary phase‐coated magnetic stir bar. Until now, only PDMS‐coated stir bars are commercially available, restricting the range of applications to the non‐selective extraction of hydrophobic compounds due to the apolar character of PDMS. In this work, a novel stir bar coated with molecularly imprinted polymer as selective extraction phase for sorptive extraction of thiabendazole (TBZ) was developed. Two different procedures, based on physical or chemical coating, were assessed for the preparation of molecularly imprinted stir bars. Under optimum conditions, recoveries achieved both in imprinted and non‐imprinted polymer stir bars obtained by physical coating were very low, whereas TBZ was favourably retained by imprinted over non‐imprinted polymer stir bars obtained by chemical coating and thus the latter approach was used in further studies. Different parameters affecting both stir‐bars preparation (i.e. cross‐linker, porogen, polymerization time) and the subsequent selective extraction of TBZ (i.e. washing, loading and elution solvents, extraction time) were properly optimized. The molecularly imprinted coated stir bars were applied to the extraction of TBZ from citrus samples (orange, lemon and citrus juices) allowing its final determination at concentrations levels according to current regulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号