首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
A simple liquid-liquid-liquid microextraction with automated movement of the acceptor and the donor phase (LLLME/AMADP) technique is described for the quantitative determination of five phenoxyacetic acids in water using a disposable and ready to use hollow fiber. The target compounds were extracted from the acidified sample solution (donor phase) into the organic solvent residing in the pores of the hollow fiber and then back extracted into the alkaline solution (acceptor phase) inside the lumen of the hollow fiber. The fiber was held by a conventional 10-microl syringe. The acceptor phase was sandwiched between the plunger and a small volume of the organic solvent (microcap). The acceptor solution was repeatedly moved in and out of the hollow fiber assisted by a programmable syringe pump. This repeated movement provides a fresh acceptor phase to come in-contact with the organic phase and thus enhancing extraction kinetics leading to high enrichment of the analytes. The microcap separates the aqueous acceptor phase and the donor phase in addition of being partially responsible for mass transfer of the analytes from donor solution (moving in and out of the hollow fiber from the open end of the fiber) to the acceptor solution. Separation and quantitative analyses were then performed using liquid chromatography (LC) with ultraviolet (UV) detection at 280 nm. Various parameters affecting the extraction efficiency viz. type of organic solvent used for immobilization in the pores of the hollow fiber, extraction time, stirring speed, effect of sodium chloride, and concentration of donor and acceptor phases were studied. Repeatability (RSD, 3.2-7.4%), correlation coefficient (0.996-0.999), detection limit (0.2-2.8 ng ml(-1)) and enrichment factors (129-240) were also investigated. Relative recovery (87-101%) and absolute recoveries (4.6-13%) have also been calculated. The developed method was applied for the analysis of river water.  相似文献   

2.
Automated dynamic liquid-liquid-liquid microextraction (D-LLLME) controlled by a programmable syringe pump and combined with HPLC-UV was investigated for the extraction and determination of 5 phenoxy acid herbicides in aqueous samples. In the extraction procedure, the acceptor phase was repeatedly withdrawn into and discharged from the hollow fiber by the syringe pump. The repetitive movement of acceptor phase into and out of the hollow fiber channel facilitated the transfer of analytes into donor phase, from the organic phase held in the pore of the fiber. Parameters such as the organic solvent, concentrations of the donor and acceptor phases, plunger movement pattern, speed of agitation and ionic strength of donor phase were evaluated. Good linearity of analytes was achieved in the range of 0.5-500 ng/ml with coefficients of determination, r2 > 0.9994. Good repeatabilities of extraction performance were obtained with relative standard deviations lower than 7.5%. The method provided up-to 490-fold enrichment within 13 min. In addition, the limits of detection (LODs) ranged from 0.1 to 0.4 ng/mL (S/N = 3). D-LLLME was successfully applied for the analysis of phenoxy acid herbicides from real environmental water samples.  相似文献   

3.
A liquid‐phase microextraction coupled with LC method has been developed for the determination of organophosphorus pesticides (methidation, quinalphos and profenofos) in drinking water samples. In this method, a small amount (3 μL) of isooctane as the acceptor phase was introduced continually to fill‐up the channel of a 1.5 cm polypropylene hollow fiber using a microsyringe while the hollow fiber was immersed in an aqueous donor solution. A portion of the acceptor phase (ca. 0.4 μL) was first introduced into the hollow fiber and additional amounts (ca. 0.2 μL) of the acceptor phase were introduced to replenish at intervals of 3 min until set end of extraction (40 min). After extraction, the acceptor phase was withdrawn and transferred into a 2 mL vial for a drying step prior to injection into a LC system. Parameters that affect the extraction efficiency were studied including the organic solvent, length of fiber, volume of acceptor and donor phase, stirring rate, extraction time, and effect of salting out. The proposed method provided good enrichment factors of up to 189.50, with RSD ranging from 0.10 to 0.29%, analyte recoveries of over 79.80% and good linearity ranging from 10.0 to 1.25 mg/L. The LOD ranged from 2.86 to 82.66 μg/L. This method was applied successfully to the determination of organophosphorus pesticides in selected drinking water samples.  相似文献   

4.
A simple liquid–liquid–liquid microextraction device of new design was used to pre-concentrate phenols from water samples before liquid chromatographic (LC) analysis. Extraction was induced by the pH difference inside and outside an organic phase located at the interface. The pH of the donor phase outside the organic phase was adjusted to 1 with HCl whereas the acceptor phase was a basic solution at pH 13. On stirring neutral phenols were extracted into the organic solvent then back-extracted into 1 μL of basic acceptor solution suspended from the tip of a micro syringe. The acceptor phase was then withdrawn into the micro syringe and injected directly into the LC. The technique uses a low-cost disposable extraction ‘device’ and is very convenient to operate. Up to 230-fold enrichment of analytes could be achieved. This procedure could also serve as a sample clean-up step because neutral and basic compounds were not extracted into the acceptor phase. The RSD (n = 5) was better than 6.2% and the linear calibration range was from 1 to 1000 µg–L−1 with r 2 ≥ 0.992.Optimization of experimental conditions (rate of stirring, ionic strength of the sample solution, concentration of reagents, time of extraction, and organic solvent volume) were also examined. The method was applied to the determination of phenols in tap and well waters.Revised: 14 February and 29 March 2005  相似文献   

5.
In this article, a simple new solvent microextraction technique is described for the extraction of ionizable organic compounds. This involves performing simultaneous forward- and back-extraction across an organic film immobilized in the pores of a porous polypropylene hollow fiber. Four chlorophenoxyacetic acid herbicides were chosen as model compounds. The target compounds are extracted from the stirred acidic aqueous sample (adjusted to 0.5 M HCl; donor phase) through a thin film of an organic solvent residing in the pores of a polypropylene hollow fiber; they are then finally extracted into another alkaline aqueous phase (1 M NaOH; acceptor phase). Both ends of the fiber are pressure-sealed. The acceptor phase was analyzed by liquid chromatography (LC). This method gave good enrichment (by a factor of 438-553) of the analytes in 40 min extraction time with reasonably good reproducibility. The analytical potential of the method was demonstrated by applying the method to spiked river water sample.  相似文献   

6.
Three-phase hollow fiber-mediated liquid-phase microextraction followed by HPLC was used for the determination of three synthetic estrogens, namely diethylstilbestrol, dienestrol, and hexestrol, in wastewater. Extraction conditions including organic solvent, volume ratio between donor solution and acceptor phase, extraction time, stirring rate, donor phase and acceptor phase were optimized. The target compounds were extracted from a 10 mL aqueous sample at pH 1.5 (donor solution) through a 45 mm in length hollow polypropylene fiber that was immersed in 1-octanol in advance, and then the hollow fiber was filled with 10 microL 0.5 mol/L sodium hydroxide solution (acceptor phase). After a 40 min extraction, the acceptor phase was directly injected into an HPLC system for detection. Under the optimized extraction conditions, a large enrichment factor (more than 300-fold) was achieved for the three estrogens. The determination limit at an S/N of 3 ranged from 0.25 to 0.5 microg/L for the estrogens. The recovery ratio was more than 86% in the determination of these estrogens in wastewater.  相似文献   

7.
Dynamic three-phase hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) based on two immiscible organic solvents, with automated movement of organic acceptor phase to facilitate mass transfer was introduced for the first time. Polycyclic aromatic hydrocarbons were used as model compounds and extracted from water and soil samples. The extraction involved filling an 8 cm length of hollow fiber with 25 μL of organic acceptor solvent using a microsyringe, followed by impregnation of the pores in the fiber wall with n-dodecane. The fiber was then immersed in 20 mL of aqueous sample solution. During extraction, the organic acceptor phase was repeatedly moved in the lumen of the hollow fiber by movement of the syringe plunger controlled by programmable syringe pump. Following this microextraction, 2 μL of organic acceptor phase was injected into gas chromatography-flame ionization detector. This new technique provided up to 554-fold preconcentration of the analytes under the optimized conditions. Good repeatabilities (with RSDs ≤8.4%) were obtained. Detection limits were in the range of 0.2-0.5 μg/L. The utilization of the proposed method for extraction of the polycyclic aromatic hydrocarbons from different real samples (such as water and soil samples) also gave good precision and recovery.  相似文献   

8.
Three-phase solvent bar microextraction (TPSBME) technique is described for the quantitative determination of trace amounts of clenbuterol (CB) in urine samples using liquid chromatography (LC) and electrospray tandem mass spectrometry (ES-TMS). CB was extracted from a basified urine sample (donor phase) into the organic solvent residing in the pores of a freely moving hollow fiber and then back extracted into an acidic solution (acceptor phase) inside the lumen of the hollow fiber. The ends of the fiber were pressure-sealed. Here, forward and back extraction took place spontaneously. We studied various parameters affecting the extraction efficiency viz. type of organic solvent (octanol, nonanol and dihexyl ether) used for immobilization in the pores of the hollow fiber, i.e. extraction time (10-40 min), stirring speed (0-1000 rpm), effect of sodium chloride (0-25%, w/v) and concentration of the donor (0.25-3 M NaOH) and the acceptor (0.5-5 M formic acid) phases. After extraction, CB was analyzed by injecting the analyte enriched acceptor phase into LC combined with ES-TMS. Enrichment factor (79), repeatability (R.S.D. = 5.1%), correlation coefficient (0.9972, for the range of 0.1-4 ng mL−1), detection limit (7 pg mL−1) were also investigated. The present technique is compared with the reported solid phase microextraction techniques in terms of selectivity, analysis time per extraction, cost of analysis per extraction, and precision. Among all microextraction techniques reported, this technique is the most economical sample preparation/preconcentration technique to our knowledge. The method was applied for the analysis of CB in human urine.  相似文献   

9.
This paper presents a novel and simple cleanup procedure based on hollow fiber liquid-phase microextraction (HF-LPME) for the determination of trace estradiol in environmental. Estradiol was extracted from a 140-mL water sample (the donor phase) into the pores of the hollow fiber wall organic solvent, then into the organic solvent (the acceptor phase) in the lumen of the hollow fiber. Afterwards, the hollow fiber was eluted with methanol to capture estradiol from the acceptor phase. Different experimental parameters, including the organic phase type and its volume, compositions of the donor phases, ionic strength, stirring rate, temperature, and the extraction times were controlled and optimized based on the response of the HPLC instrument. Under the optimized experimental conditions, the proposed method was found to be linear in the concentration of 1-1000 ng/mL for estradiol, and the limit of detection was 0.1 ng/mL. Furthermore, the method provided a good enrichment factor of 300, and repeatability (relative standard deviation = 5.5). Finally, the proposed method was applied for the analysis of real environmental samples.  相似文献   

10.
A simple liquid-liquid-liquid microextraction device utilizing a 2 cm x 0.6 mm I.D. hollow fiber membrane was used to preconcentrate nitrophenols from water sample prior to capillary liquid chromatography (cLC) analysis. The extraction procedure was induced by the pH difference inside and outside the hollow fiber. The donor phase outside the hollow fiber was adjusted to pH approximately 1 with HCl; the acceptor phase was NaOH solution used at various concentrations. Organic solvent was immobilized into the pores of the hollow fiber. With stirring, the neutral nitrophenols outside the fiber were extracted into the organic solvent, then back extracted into 2 microl of basic acceptor solution inside the fiber. The acceptor phase was then withdrawn into a microsyringe and injected into the cLC system directly. This technique used a low-cost disposable extraction "device" and is very convenient to operate. Up to 380-fold enrichment of analytes could be achieved. This procedure could also serve as a sample clean-up step because large molecules and basic compounds were not extracted into the acceptor phase. The RSD (n=6) was less than 6.2%, while the linear calibration range was from 1 to 200 microg/ml with r>0.998. The procedure was applied to the analysis of seawater.  相似文献   

11.
三相中空纤维式液相微萃取用于快速富集血浆中的尼古丁   总被引:8,自引:0,他引:8  
杨新磊  罗明标  唐毓萍 《色谱》2006,24(6):555-559
建立了一种以三相中空纤维式液相微萃取(TP-HF-LPME)进行样品前处理,采用高效液相色谱快速、准确测定血浆中尼古丁含量的方法。研究表明该方法集萃取、富集、净化为一步,极大地简化了传统血浆成分测定的前处理过程,是一种快速、有效、绿色的前处理方法。方法的线性范围为0.1~50 mg/L,相关系数(r2)为0.9996,检测限为0.05 mg/L (信噪比为3),相对标准偏差小于5%。  相似文献   

12.
Hollow fiber-based liquid-liquid-liquid microextraction (HF-LLLME) followed by flow injection analysis and diode array detection (FIA-DAD) was applied as a simple and sensitive quantitative method for the determination of phenazopyridine in urine and plasma samples. Flow injection system included a conventional HPLC system (without a chromatographic column) and a diode array detector. The extraction of phenazopyridine was carried out using diphenyl ether as the organic phase for filling the pores of the hollow fiber wall, and 0.1 M H(2)SO(4) solution as acceptor phase in the lumen of the fiber. The factors affecting the HF-LLLME and flow injection analysis including type of organic solvent, pH of donor phase, extraction temperature, extraction time, stirring rate, and pH of mobile phase were investigated and the optimal extraction conditions were established. With the consumption of 5 mL of sample solution, the enrichment factor was about 230. The limit of detection was 0.5 μg/L with inter- and intra-day precision being (RSD%) 6.9 and 4.9, respectively. Excellent linearity was found between 5 and 200 μg/L.  相似文献   

13.
A new and fast hollow fiber based liquid phase microextraction (HF-LPME) method using volatile organic solvents coupled with high-performance liquid chromatography (HPLC) was developed for determination of aromatic amines in the environmental water samples. Analytes including 3-nitroaniline, 3-chloroaniline and 4-bromoaniline were extracted from 6 mL basic aqueous sample solution (donor phase, NaOH 1 mol L−1) into the thin film of organic solvent that surrounded and impregnated the pores of the polypropylene hollow fiber wall (toluene, 20 μL), then back-extracted into the 6 μL acidified aqueous solution (acceptor phase, HCl 0.5 mol L−1) in the lumen of the two-end sealed hollow fiber. After the extraction, 5 μL of the acceptor phase was withdrawn into the syringe and injected directly into the HPLC system for the analysis. The parameters influencing the extraction efficiency including the kind of organic solvent and its volume, composition of donor and acceptor phases and the volume ratio between them, extraction time, stirring rate, salt addition and the effect of the analyte complexation with 18-crown-6 ether were investigated and optimized. Under the optimal conditions (donor phase: 6 mL of 1 mol L−1 NaOH with 10% NaCl; organic phase: 20 μL of toluene; acceptor phase: 6 μL of 0.5 mol L−1 HCl and 600 m mol L−1 18-crown-6 ether; pre-extraction and back-extraction times: 75 s and 10 min, respectively; stirring rate: 800 rpm), the obtained EFs were between 259 and 674, dynamic linear ranges were 0.1-1000 μg L−1 (R > 0.9991), and also the limits of detection were in the range of 0.01-0.1 μg L−1. The proposed procedure worked very well for real environmental water samples with microgram per liter level of the analytes, and good relative recoveries (91-102%) were obtained for the spiked sample solutions.  相似文献   

14.
A hollow fiber‐based liquid phase microextraction strategy combined with high‐performance liquid chromatography was evaluated for the quantitative determination of trimetazidine in human plasma. Trimetazidine was extracted from a 2.1 mL basified plasma sample (donor phase) into the organic solvent (n‐octanol) impregnated in the pores of a hollow fiber and then extracted into an acidic solution (acceptor phase) inside the lumen of the hollow fiber. The result showed that transport of drugs from alkaline sample solution into 0.5 m HCl occurred efficiently when 25 μL of 250 mm sodium 1‐octanesulfonate was added into the donor phase. Several parameters influencing the efficiency of the method, such as the nature of organic solvent used to impregnate the membrane, compositions of donor phase and acceptor phase, type and concentration of carrier, extraction time, stirring rate and salt concentration, were investigated and optimized. Under the optimal conditions, the calibration curves were obtained in the range of 5–200 ng/mL with reasonable linearity (r > 0.9980). The method was successfully applied to determine the concentration of trimetazidine in human plasma. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
建立了中空纤维液相微萃取-高效液相色谱法测定纺织品中10种含氯苯酚类化合物的方法。系统地优化了影响萃取效率的因素,得到的最佳萃取条件为:萃取溶剂为正己烷,接受相NaOH溶液的浓度为0.10 mol/L,萃取时间为60 min,搅拌速度为600 r/min。在最佳萃取条件下,10种含氯苯酚在0.01~1.00 mg/L范围内线性关系良好(r>0.999),10种含氯苯酚的检出限(信噪比为3)为0.01 mg/kg,富集倍数为95~101。在空白样品中添加0.01、0.05和0.1 mg/kg 3个不同水平的10种含氯苯酚类化合物,其平均回收率为78.8%~105.1%,相对标准偏差为0.3%~7.3%。研究结果表明该方法灵敏度高、简便、准确,可用于纺织品中含氯苯酚类化合物的测定。  相似文献   

16.
魏超  卢珩俊  陈梅兰  朱岩 《色谱》2011,29(1):54-58
建立了中空纤维液-液-液三相微萃取-高效液相色谱法测定水中4种酚类化合物的方法.实验系统地优化了影响萃取效率的因素(包括有机溶剂种类、接收相浓度、分散相pH值、加盐量、转速及萃取时间).得到的最佳萃取条件为:萃取剂为正辛醇,接收相NaOH溶液的浓度为0.09 mol/L,分散相的pH为4,萃取时间为40 min,搅拌速...  相似文献   

17.
A simple and solvent-minimized sample preparation technique based on two-phase hollow fiber-protected liquid-phase microextraction has been developed and used for the determination of partition coefficient and analysis of selected pesticides in environmental water samples. The analysis was performed by gas chromatography–electron capture detector. Three pesticides namely hexaconazole, quinalphos, and methidathion were considered as target analytes. Extraction conditions such as solvent identity, salt concentration, stirring speed, extraction time, length of the hollow fiber, and volume of donor phase were optimized. The analytes were extracted from a donor phase (water sample) through 3 μL of an organic solvent immobilized in the pores of a porous polypropylene hollow fiber and then into the acceptor phase present inside the hollow fiber. Excellent extractions of the analytes were achieved under the optimized conditions, with relative standard deviations of 4.6–7.9%, correlation coefficients (r 2) of 0.9954–0.9986 and limits of detection of 3–7 ng L?1. The proposed method provided good average enrichment factors of up to 250-fold. The partition coefficients of the analytes determined were found to be directly correlated with the enrichment factor. The present methodology also confirms the robustness of microextraction for monitoring trace levels of pesticides in environmental water samples.  相似文献   

18.
A preconcentration technique, which involves liquid-liquid-liquid microextraction, was developed to determine phenoxy herbicides in bovine milk. A layer of organic phase was impregnated into the pores of a 3.5 cm long porous hollow fiber, while the internal volume of the fiber was filled with NaOH solution (the acceptor solution) that was connected directly to the needle of a microsyringe. The fiber was then immersed into 8 ml of acidified milk sample. When the sample solution was stirred, acidic analytes were extracted into the organic phase and back extracted simultaneously into the alkaline acceptor medium as the analytes were protonated at low pH and deprotonated at high pH. After extracting for a prescribed time, 5 microl acceptor solution was taken back into the syringe and injected directly into a HPLC system for quantification. The analytes were extracted quantitatively from the sample solution into the acceptor solution with a large enrichment factor of 900. Due to its low cost, the hollow-fiber extraction device was disposed of after a single extraction that eliminated the possibility of carry over effects. In addition, because a small volume of organic solvent was required and little waste is generated, the procedure is environmentally friendly, and is compatible with the "green chemistry" concept.  相似文献   

19.
A three‐phase hollow‐fiber liquid‐phase microextraction based on deep eutectic solvent as acceptor phase was developed and coupled with high‐performance capillary electrophoresis for the simultaneous extraction, enrichment, and determination of main active compounds (hesperidin, honokiol, shikonin, magnolol, emodin, and β,β′‐dimethylacrylshikonin) in a traditional Chinese medicinal formula. In this procedure, two hollow fibers, impregnated with n‐heptanol/n‐nonanol (7:3, v/v) mixture in wall pores as the extraction phase and a combination (9:1, v/v) of methyltrioctylammonium chloride/glycerol (1:3, n/n) and methanol in lumen as the acceptor phase, were immersed in the aqueous sample phase. The target analytes in the sample solution were first extracted through the organic phase, and further back‐extracted to the acceptor phase during the stirring process. Important extraction parameters such as types and composition of extraction solvent and deep eutectic solvent, sample phase pH, stirring rate, and extraction time were investigated and optimized. Under the optimal conditions, detection limits were 0.3–0.8 ng/mL with enrichment factors of 6–114 for the analytes and linearities of 0.001–13 μg/mL (r2 ≥ 0.9901). The developed method was successfully applied to the simultaneous extraction and concentration of the main active compounds in a formula of Zi‐Cao‐Cheng‐Qi decoction with the major advantages of convenience, effectiveness, and environmentally friendliness.  相似文献   

20.
A new design of hollow fiber solid–liquid phase microextraction (HF-SLPME) was developed for the determination of caffeic acid in medicinal plants samples as Echinacea purpure. The membrane extraction with sorbent interface used in this research is a three-phase supported liquid membrane consisting of an aqueous (donor phase), organic solvent/nano sorbent (membrane) and aqueous (acceptor phase) system operated in direct immersion sampling mode. The multi-walled carbon nanotube dispersed in the organic solvent is held in the pores of a porous membrane supported by capillary forces and sonification. It is in contact with two aqueous phases: the donor phase, which is the aqueous sample, and the acceptor phase, usually an aqueous buffer. All microextraction experiments were supported using an Accurel Q3/2 polypropylene hollow fiber membrane (600 μm I.D., 200 μm wall thicknesses, and 0.2 μm pore size). The experimental setup is very simple and highly affordable. The hollow fiber is disposable, so single use of the fiber reduces the risk of cross-contamination and carry-over problems. The proposed method allows the very effective and enriched recuperation of an acidic analyte into one single extract. In order to obtain high enrichment and extraction efficiency of the analyte using this novel technique, the main parameters were optimized. Under the optimized extraction conditions, the method showed good linearity (0.0001–50 μg/L), repeatability, low limits of detection (0.00005 μg/L) and excellent enrichment (EF = 2108).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号