首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
ABSTRACT

In this study, a simple and efficient solid phase extraction procedure was developed for simultaneous separation and preconcentration of Ba, Cd, Co, Cu, Mn and Ni. The methodology was based on preconcentration of the target analytes on N,N’-bis(4-methoxysalicylidene)-1,3-propanediamine modified silica gel prior to inductively coupled plasma optic emission spectrometry detection. The experimental conditions were as follows: pH of sample 5.00; sample and eluent flow rates 3 mL min?1; sample volume 25 mL; eluent 0.5 mol L?1 HNO3; eluent volume 3.0 mL. Preconcentration factor was achieved as 33.3 for Ba, Co, Mn; 83.3 for Cd, Ni; 166.7 for Cu. Limits of detection were found as 0.33, 0.26, 0.27, 0.36, 0.27 and 0.19 µg L?1 for Ba, Cd, Co, Cu, Mn and Ni, respectively. The relative standard deviations of 2.6–3.8% were obtained via nine parallel analyses. The suggested procedure was successfully validated by the analysis of TMDA-53.3 Lake Ontario water and ERM-CA022a soft drinking water certified reference materials and applied to various natural water samples.  相似文献   

2.
A study on the simultaneous determination of Ni(II) and Co(II) dimethylglyoximates (Ni‐DMG and Co‐DMG) through adsorptive cathodic stripping voltammetry at an in situ bismuth‐modified gold electrode (Bi‐AuE) is reported. The key operational parameters, such as Bi(III) concentration, accumulation potential and accumulation time were optimized and the morphology of the Bi‐microcrystals deposited on the Au‐electrode was studied. The Bi‐AuE allowed convenient analysis of trace concentrations of solely Ni(II) or of Ni(II) and Co(II) together, with cathodic stripping voltammograms characterized by well‐separated stripping peaks. The calculated limit of detection (LOD) was 40 ng L?1 for Ni(II) alone, whereas the LOD was 98 ng L?1 for Ni(II) and 58 ng L?1 for Co(II), when both metal ions were measured together. The optimized method was finally applied to the analysis of certified spring water (NIST1640a) and of natural water sampled in the Lagoon of Venice. The results obtained with the Bi‐AuE were in satisfactory agreement with the certified values and with those provided by complementary techniques, i.e., ICP‐OES and ICP‐MS.  相似文献   

3.
This article the first reports on a fabrication and application of an electrochemical three electrode micro‐set containing: in situ plated lead film on carbon fiber working microelectrode, Ag/AgCl reference electrode and a platinum wire counter electrode placed in one casing for simultaneous Ni(II) and Co(II) traces determination by square wave adsorptive stripping voltammetry (SW AdSV). Ni(II) and Co(II) in forms of their complexes with nioxime were accumulated on the lead film plated on a carbon fibers microelectrode during standard procedure of measurement. Thanks to the fact that measurements were performed in micro‐vessel of a volume of 200 μl small amounts of reagents were used to prepare samples for measurements. In addition, because of the use of microelectrode, sample solutions were not mixed during accumulation step of measurements. This fact creates the possibility of conducting fields analysis. The experimental parameters (composition of the supporting electrolyte, potential and time of accumulation) and possible interference effects were investigated. The linear calibration graphs for Ni(II) and Co(II) were in the range from 2×10?9 to 1×10?7 mol L?1 and from 2×10?10 to 1×10?8 mol L?1 for Ni(II) and Co(II), respectively. The correctness of the proposed method was checked by determining Ni(II) and Co(II) in the certified reference material (SPS‐SW1) with satisfactory results.  相似文献   

4.
A new method that utilizes microcrystalline anthracene modified with 8‐hydroxyquinoline as an adsorbent has been developed for the preconcentration of trace Zinc(II). The possible reaction mechanism is discussed in detail. The influences of different parameters, such as acidity, other metal ions, the amounts of 8‐hydroxyquinoline and anthracene, etc. on the enrichment yield of Zn(II) have been studied to optimize the experimental conditions. The experimental data were fitted well with the pseudo‐second‐order kinetic model and Langmuir model at all studied temperatures and the maximum adsorption capacity was 32.58 mg·g?1 (300 K). The thermodynamic parameters (ΔGθ, ΔHθ and ΔSθ) showed the feasibility, exothermic and spontaneous nature of the adsorption at 280~320 K. Experiments indicate that Zn(II) can be completely separated from Cu(II), Co(II), Cd(II), Mn(II), Ni(II) in the eluent. The recovery of this method is in the range of 96.0%~105.0% with preconcentration factor of 100 and the limit of detection after preconcentration is 0.068 μg·L?1. The proposed method has been successfully applied to the determination of trace Zn(II) in effluents and synthetic water sample having a composition similar to certified water sample SLRS‐4 (NRC, Canada). Analytical results obtained by this recommended method were very satisfactory.  相似文献   

5.
In this study, a simple, fast and eco-friendly ultrasound-assisted-cloud point extraction method for extraction and pre-concentration of zinc, nickel and cobalt from vegetables and foods prior to their determination by flame atomic absorption spectrometry (FAAS) was proposed. Ultrasound energy was used to shorten extraction time and reduce steps needed or to improve selectivity. The method is based on complex formation of metal ions with carmine in presence of cationic surfactant at pH 5.0, and then extraction of their hydrophobic complexes into the micellar phase of Igepal CO-630 as extractant. After optimisation, calibration curves for Zn, Co and Ni were linear in the range of 2–120, 2–220 and 2–180 μg kg?1, respectively. Limits of detection, which is described as ratio of 3×standard deviation of 12 replicate measurements of blank analysis to slope of calibration curves, were 0.5, 0.6 and 0.6 μg kg?1 for Zn, Ni and Co, respectively. Relative standard deviations (RSDs%, n: 5) for 25 μg kg?1 of each analyte were less than 3.1%. The recovery rate was higher than 94% with a lower RSD than 3.1% for five replicate measurements of 25 μg kg?1 of each analyte. The accuracy was verified using two different standard reference materials (SRM 1570a-Trace elements in spinach leaves and SRM 1548a-Typical diet), and the results were in good agreement with the certified values. The method was applied to the determinations of Zn, Ni and Co in vegetables and foods by FAAS.  相似文献   

6.
A simple, fast, sensitive and greener voltammetric procedure for simultaneous analysis of nickel (Ni) and cobalt (Co) by square wave adsorptive cathodic stripping voltammetry (SW‐AdCSV) using a solid bismuth vibrating electrode is presented for the first time. The procedure enables to determine Ni together with Co, in ammonia buffer 0.1 M (pH 9.2) and in the presence of oxygen, and involves an adsorptive accumulation of metal‐dimethylglyoxime (Ni‐DMG and Co‐DMG) complexes on the electrode surface. For Ni and Co, the detection limits, obtained with 30 s of accumulation time, were 0.6 and 1.0 µg L?1, respectively. The method was free of metals (Cd2+, Cr3+, Cr6+, Cu2+, Fe3+ and Pb2+ up to 50 µg L?1, Al3+ and Mn2+ up to 500 µg L?1; Zn2+ up to 300 µg L?1) interferences up to the concentrations mentioned in brackets. The proposed method was validated for simultaneous determination of Ni and Co in a certified reference surface and river waters with good results.  相似文献   

7.
A liquid‐phase microextraction technique was developed using dispersive liquid‐liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry, for the extraction and determination of trace amounts of cobalt in water samples. Microextraction efficiency factors, such as the type and volume of extraction and dispersive solvents, pH, extraction time, the chelating agent amount, and ionic strength were investigated and optimized. Under optimum conditions, an enrichment factor of 160 was obtained from 10.0 mL of water sample. The calibration graph was linearin the range of 1.15‐110 μg L?1 with a detection limit of 0.35 μg L?1. The relative standard deviation for ten replicate measurements of 10 and 100 μg L?1 of cobalt were 3.26% and 2.57%, respectively. The proposed method was assessed through the analysis of certified reference water or recovery experiments.  相似文献   

8.
In this study, a simple and efficient method of ligandless-ultrasound-assisted emulsification microextraction (LL-USAEME) followed by inductively coupled plasma-optical emission spectrometry (ICP-OES) has been developed for simultaneous extraction, preconcentration and determination of manganese, cadmium, cobalt and nickel in water samples. In the proposed approach, tetrachloroethylene was selected as extraction solvent. The effect of important experimental factors such as volume of extraction solvent, pH, sonication time, salt concentration, and temperature was investigated by using a fractional factorial design (25?1) to identify important factors and their interactions. In the next step, a Box-Behnken design (BBD) was applied for optimisation of significant factors. The obtained optimal conditions were: 30?µL for extraction solvent, 12 for pH, 5?min for sonication time, and 5% w/v for salt concentration. The limits of detections (LODs) for Cd(II), Co(II), Mn(II) and Ni(II) were 0.20, 0.13, 0.21 and 0.28?µg?L?1, respectively. Relative standard deviations (RSD, C?=?200.0?µg?L?1, n?=?9) were between 3.4–7.5% and the calibration graphs were linear in the range of 0.25 to 1000.0?µg?L?1 for Mn, 0.5–1000.0?µg?L?1 for Co and Ni and 1.0–250.0?µg?L?1 for Cd. The determination coefficients (R 2) of the calibration curves for the analytes were in the range of 0.993 to 0.999. The proposed method was validated by using two certified reference materials, and also the method was applied successfully for the determination of heavy metals in different real water samples.  相似文献   

9.
A novel adsorbent of multi-wall carbon nanotubes (MWCNTs) chemically modified silica (MWCNTs-silica) was synthesised and employed as the adsorbent material for solid-phase extraction (SPE) of trace Zn(II), Cu(II), Cd(II), Cr(III), V(V) and As(V) in environmental water samples followed by inductively coupled plasma optical emission spectrometry detection. This material inherits the advantages of nanomaterial MWCNTs and conventional silica with dual functional groups (–NH2 and –COOH), and avoid the problem of nanomaterial in SPE, such as high pressure. The factors affecting the separation and preconcentration of target elements such as pH, sample flow rate and volume, eluent concentration and volume were investigated. Under the optimised conditions, the detection limits for Zn(II), Cu(II), Cd(II), Cr(III), V(V) and As(V) were 0.27, 0.11, 0.45, 0.91, 0.55 and 0.67 μg L?1 with the relative standard deviations of 3.1, 5.9, 4.1, 4.0, 7.3 and 8.6% (c = 10 μg L?1, n = 7), respectively. The adsorption capacity of MWCNTs-silica was 26.6, 70.0, 13.8, 58.0, 20.0 and 20.0 mg g?1 for Zn(II), Cu(II), Cd(II), Cr(III), V(V) and As(V), respectively, and the prepared adsorbent could be reused more than 100 times. In order to validate the developed method, two certified reference materials of GSBZ50009-88 and GSBZ 50029-94 environmental waters were analysed and the determined values were in good agreement with the certified values. The developed method has been applied to the determination of trace elements in environmental water samples with satisfactory results.  相似文献   

10.
A solid phase extraction system for separation and preconcentration of trace amounts of Pb(II), Ni(II), Cd(II) and Cu(II) is proposed. The procedure is based on the adsorption of Pb2+, Ni2+, Cd2+ and Cu2+ ions on a column of 1-(2-pyridylazo)-2-naphthol (PAN) immobilised on surfactant-coated clinoptilolite prior to their determinations by Flame Atomic Absorption Spectroscopy (FAAS). The effective parameters including pH, sample volume, sample flow rate and eluent flow rate were also studied. The analytes collected on the column were eluted with 5 mL of 1 mol L?1 nitric acid. A concentration factor of 180 can be achieved by passing 900 mL of sample through the column. The detection limits (3 s) for Cd, Cu, Pb and Ni were found to be 0.28, 0.12, 0.44 and 0.46 µg L?1, respectively. The relative SDs at 10 µg L?1 (n = 10) for analytes were in the range of 1.2–1.4%. The method was applied to the determination of Pb, Ni, Cd and Cu in water samples.  相似文献   

11.
A sensitive and simple method has been established for simultaneous preconcentration of trace amounts of Pb (II) and Ni (II) ions in water samples prior to their determination by flame atomic absorption spectrometry. This method was based on the using of a micro-column filled with graphene oxide as an adsorbent. The influences of various analytical parameters such as solution pH, adsorbent amount, eluent type and volume, flow rates of sample and eluent, and matrix ions on the recoveries of the metal ions were investigated. Using the optimum conditions, the calibration graphs were linear in the range of 7–260 and 5–85 μg L?1 with detection limits (3Sb) of 2.1 and 1.4 μg L?1 for lead and nickel ions, respectively. The relative standard deviation for 10 replicate determinations of 50 μg L?1 of lead and nickel ions were 4.1% and 3.8%, respectively. The preconcentration factors were 102.5 and 95 for lead and nickel ions, respectively. The adsorption capacity of the adsorbent was also determined. The method was successfully applied to determine the trace amounts of Pb (II) and Ni (II) ions in real water samples. The validation of the method was also performed by the standard reference material.  相似文献   

12.
In this work functionalised mesoporous silica spheres have been utilised for the simultaneous preconcentration of nickel and cobalt. The silica spheres (SiSPs) prepared by the sol-gel method were functionalised with sodium diethyldithiocarbamate (DDTC-SiSPs). They were characterised by SEM, TEM, XRD, FTIR, CHN and nitrogen adsorption. The adsorption efficiency of DDTC-SiSPs was examined by batch equilibrium technique. The DDTC-SiSPs showed 100% adsorption for Ni (II) and Co (II). The effect of changing variables such as pH, shaking time, sample volume, preconcentration factor, eluent type and volume were investigated so as to obtain maximum recovery with high selectivity over interfering ions. The maximum adsorption capacity was found to be 15.15 mg g?1 and 11.80 mg g?1 for Ni (II) and Co (II) respectively using DDTC-SiSPs. 100% recovery was achieved with 5 mL of 2 M HNO3. The maximum preconcentration factor was 400 and the 3σ limits of detection were 0.201 µg L?1 and 0.198 µg L?1 for Ni (II) and Co (II) respectively. Thermodynamic studies showed that adsorption of Ni (II) and Co (II) on DDTC-SiSPs is exothermic with enthalpy changes of –0.514 KJ mol?1 and –0.854 KJ mol?1 for Ni (II) and Co (II) respectively. The method was applied to the preconcentration and determination of Ni (II) and Co (II) from tap, river and sea water.  相似文献   

13.
A selective and sensitive derivative method has been proposed for the simultaneous determination of trace amounts of Co(II) and Ni(II) with morpholinedithiocarbamate (MDTC) in the presence of sodium lauryl sulphate (SLS). The molar absorption coefficients of the 1:2 complex of Co(II) and Ni(II) at 326 nm and 322 nm are 2.248 × 104 and 2.505 × 104 L mol?1 cm?1 for zero order. The analytical sensitivity for the second derivative of Co(II) and Ni(II) complexes are 0.0044 μg mL?1 and 0.0060 μg mL?1. The developed derivative procedure, using the zero‐crossing technique, has been successfully applied for the analysis of Co(II) and Ni(II) simultaneously in different alloy samples.  相似文献   

14.
A new, simple and cheap dispersive liquid–liquid microextraction (DLLME) procedure was optimized for the preconcentration of trace amounts of Ni(II) as a prior step to its determination by flame atomic absorption spectrometry (FAAS). It is based on the microextraction of nickel, where appropriate amounts of the extraction solvent (CHCl3), disperser solvent (ethanol) and chelating agent, name 5‐[(Z)‐isoxazol‐3‐yl‐diazenyl]‐2‐methyl‐quinolin‐8‐ol (MMD), were firstly synthesized/characterized and used. Various parameters that affect the extraction procedure such as pH, centrifugation rate and time, the chelating agent (MMD) concentration and sampling volume on the recovery of Ni(II) were investigated. The preconcentration of a 20 ml sample solution was thus enhanced by a factor of 80. The resulting calibration graph was linear in the range of 0.24–10 mg L−1 with a correlation coefficient of 0.9998. The limit of detection (3 s/b) obtained under optimal conditions was 1.00 μg L−1. The relative standard deviation for certified reference material determinations was 1.2%. The accuracy of the method was verified by the determination of Ni(II) in the certified reference material of wastewater (Waste water CWW TMD). The proposed procedure was successfully applied to the determination of Ni(II) in some fake jewelry and cosmetics samples.  相似文献   

15.
A green, simple, rapid and efficient solventless temperature-assisted homogeneous liquid-liquid microextraction based on 8-hydroxyquinoline as complexing agent and extractant, followed by flame atomic absorption spectrometry was developed for the extraction, enrichment, and determination of trace amounts of nickel and cobalt in aqueous samples. For this purpose, first, a specified amount of 8-hydroxyquinoline is added to the analytes solution. Then the temperature of the solution is increased to melt 8-hydroxyquinoline and form a homogeneous solution. Then, it is cooled to room temperature and a cloudy solution is formed due to decreasing 8-hydroxyquinoline solubility. The solution is then centrifuged, and 8-hydroxyquinoline particles containing the produced complexes (8-hydroxyquinoline-cation) are collected at the bottom of the tube. They are removed and dissolved in a suitable solvent and injected to the detection system. The main parameters affecting the extraction efficiency, such as the amount of 8-hydroxyquinoline, solvent nature, pH, extraction temperature and heating time were investigated. Under optimum conditions, linear ranges for Co(II) and Ni(II) were 1–100 and 0.5–75 µg L?1, respectively. Relative standard deviations for intra- and inter-day precisions calculated from six repeated determinations at three different concentrations of Co(II) and Ni(II) were ≤5.2 %. Moreover, the obtained detection limits of the analytes were 0.35 and 0.20 µg L?1 for Co(II) and Ni(II), respectively. The accuracy of the developed procedure was checked by analysing SPS-WW2 Batch 108 water as a certified reference material. Finally, the developed method was successfully applied for the determination of the selected cations in water and fruit juice samples.  相似文献   

16.
Cadmium and nickel ions have been preconcentrated on Geobacillus thermoleovorans subsp. stromboliensis, immobilized on Amberlite XAD-4, and were determined by flame atomic absorption spectrometry (FAAS). Parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of solution and the matrix interference effect on retention have been studied, and extraction conditions were optimized. Elution of Cd(II) and Ni(II) from minicolumns was carried out with 1.0 M hydrochloric acid or nitric acid with recoveries from 97 to 100%. The sorption capacity is 0.0373 and 0.0557 mmol g?1 for Cd(II) and Ni(II), respectively. The detection limits were 0.24 μg L?1 for cadmium and 0.3 μg L?1 for nickel. The relative standard deviations of the procedure were below 10%. The procedure was validated by analyzing certified reference materials and applied to the determination of Cd(II) and Ni(II) in natural water and food samples.  相似文献   

17.
A carbon paste electrode modified with 2‐aminothiazole functionalized poly(glycidylmethacrylate‐methylmethacrylate‐divinylbenzene) microspheres was used for trace determination of mercury, copper and lead ions. After the open‐circuit accumulation of the heavy metal ions onto the electrode, the sensitive anodic stripping peaks were obtained by square wave anodic stripping voltammetry (SWASV)). Many parameters such as the composition of the paste, pH, preconcentration time, effective potential scan rate and stirring rate influence the response of the measurement. The procedures were optimized for most sensitive and reliable determinations of the desired species. For a 10‐min preconcentration time in synthetic solutions at optimum instrumental and experimental conditions, the detection limit (LOD) was 12.3, 2.8 and 4.5 μg L?1 for mercury, copper and lead, respectively. The limits of detection may be enhanced by increasing the preconcentration time. For example, LOD of mercury and copper was 4.9 and 1.0 μg L?1 for fifteen minutes preconcentration time. The sensitivity may also considered to be increased by using a more suitable electrode composition targeting the more conductive electrode with lesser amount of modified polymer for sub‐μg L?1 levels of heavy metal ions. The optimized method was successfully applied to the determination of copper in tap water and waste water samples by means of standard addition procedure. The copper content found was comparable with the certified concentration of the waste water sample. The calibration plots for mercury and lead spiked real samples were also drawn.  相似文献   

18.
Polystyrene (PS) was extracted from styrofoam waste and functionalised with schiff base, N,N-bis(salicylidene)cyclohexanediamine (SCHD) through an azo spacer. The resin was characterised and used for preconcentration of Pb(II), Ni(II) and Cd(II) ions prior to their trace determinations by microsample injection system–coupled flame atomic absorption spectrometry (MIS-FAAS). The recoveries of studied metal ions were achieved ≥96.0% with relative standard deviation (RSD) ≤4.5 at optimum parameters: pH 8; resin amount 300 mg; flow rates 3.0 mL min?1 of sample solution; and 2.0 mL min?1 of eluent (2.0 mol L?1 HNO3). The limits of detection (LODs) and limits of quantification (LOQs) were found to be 0.32, 0.23 and 0.21 and 1.10, 0.78 and 0.69 μg L?1, respectively, with preconcentration factors (PFs) of 500, 800 and 1000, respectively. The linear ranges of the method were 1–40, 1–25 and 1–20 μg L?1 for Pb(II), Ni(II) and Cd(II) ions, respectively. The accuracy and validation of the method were evaluated by analysis of certified reference materials (CRMs). The method was successfully applied for preconcentration of studied metal ions in wastewater and wastewater-irrigated vegetable samples.  相似文献   

19.
In this work, a glassy carbon electrode (GCE) was modified with multiwall carbon nanotubes/ionic liquid/graphene quantum dots (MWCNTs/IL/GQDs) nanocomposite. Then, the nanocomposite was decorated with nickel‐cobalt nanoparticles (Ni?Co NPs), and it was used as a non‐enzymatic glucose sensor. Field emission scanning electron microscopy, X‐ray diffraction spectroscopy, and energy dispersive spectroscopy were employed to prove the electrodeposition of the Ni?Co NPs on the surface of MWCNTs/IL/GQDs/GCE. Also, cyclic voltammetric and amperometric methods were utilized for the investigation of the electrochemical behaviour of the Ni?Co NPs/MWCNTs/IL/GQDs/GCE for glucose oxidation. The novel amperometric sensor displayed two linear ranges from 1.0 to 190.0 μmol L?1 and 190.0 to 4910 μmol L?1 with a low detection limit of 0.3 μmol L?1 as well as fast response time (2 s) and high stability. Also, the sensor showed good selectivity for glucose determination in the presence of ascorbic acid, citric acid, dopamine, uric acid, fructose, and sucrose, as potential interference species. Finally, the performance of the proposed sensor was investigated for the glucose determination in real samples. Ni?Co NPs/MWCNTs/IL/GQDs/GCE showed good sensitivity and excellent selectivity.  相似文献   

20.
Abstract

The application of β-cyclodextrin inclusion complexes to determine trace levels of bisphenol A (BPA) in aqueous solution by spectrofluorimetry was investigated. A 1:1 stoichiometry of the host-guest complex between β-CD and BPA, as well as the association constant was determined by using the changes in the fluorescence of BPA that occur when it is included in the hydrophobic cyclodextrin cavity. A simple and sensitive spectrofluorimetric method for the determination of BPA residues is presented; the applicable concentration range was 10.0 to 200.0 μgL?1. The detection limit obtained was 0.5 μg.L?1. The accuracy of the proposed method, was checked in the analysis of water samples from different sources previously spiked with different amounts of BPA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号