首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sonic spray ionization is shown to create a supersonic cloud of charged droplets able to promote efficient desorption and ionization of drugs directly from the surfaces of commercial drug tablets at ambient conditions. Compared with desorption electrospray ionization (DESI), desorption sonic spray ionization (DeSSI) is advantageous since it uses neither heating nor high voltages at the spray capillary. DeSSI therefore provides a more friendly environment in which to perform ambient mass spectrometry (MS). DeSSI-MS is herein evaluated for the analysis of drug tablets, and found to be, in general, as sensitive as DESI-MS. The (high) voltage-free DeSSI method provides, however, cleaner mass spectra with less abundant solvent cluster ions and with enough abundant analyte signal for tandem mass spectrometry (MS/MS). These features may therefore facilitate the DeSSI-MS detection of low molar mass components or impurities, or both. The higher-velocity supersonic DeSSI spray also facilitates matrix penetration thus providing more homogenous sampling and longer lasting ion signals.  相似文献   

2.
The detection and identification of proteins adsorbed onto biomaterial surfaces under ambient conditions has significant experimental advantages but has proven to be difficult to achieve with conventional measuring technologies. In this study, we present an adaptation of desorption electrospray ionization (DESI) and liquid extraction surface analysis (LESA) mass spectrometry (MS) coupled with in-situ surface tryptic digestion to identify protein species from a biomaterial surface. Cytochrome c, myoglobin, and BSA in a combination of single and mixture spots were printed in an array format onto Permanox slides, followed by in-situ surface digestion and detection via MS. Automated tandem MS performed on surface peptides was able to identify the proteins via MASCOT. Limits of detection were determined for DESI-MS and a comparison of DESI and LESA-MS peptide spectra characteristics and sensitivity was made. DESI-MS images of the arrays were produced and analyzed with imaging multivariate analysis to automatically separate peptide peaks for each of the proteins within a mixture into distinct components. This is the first time that DESI and LESA-MS have been used for the in-situ detection of surface digested proteins on biomaterial surfaces and presents a promising proof of concept for the use of ambient MS in the rapid and automated analysis of surface proteins.
Graphical abstract
?  相似文献   

3.
基于常压质谱的直接、快速、无需样品预处理检测的优势,该文拓展了其在药物质检领域的应用。采用自行搭建的解析电喷雾(DESI)装置,对常用感冒药对乙酰氨基酚片进行快速质谱检测,无需样品预处理,直接获得药片中有效成分的分子结构信息。为克服基质差异对定量分析的影响,以淀粉为基质构建对乙酰氨基酚模拟药片,在优化的基础上进行定量实验。针对实际药片中高浓度对乙酰氨基酚检测的需要,研究了其在较高浓度范围的定量关系,结果显示,方法对0.35~4.52 mg/mm^2范围内的对乙酰氨基酚具有较好的线性关系(r^2=0.9982),定量下限为1.903 ng/mm^2,检出限为0.237 ng/mm^2,加标回收率为102%~114%。对3种市售的对乙酰氨基酚片进行直接检测,与厂家提供的标准数据相比,相对标准偏差(RSD)为7.2%~12%,表明方法具有较好准确度。该工作很好地证明了DESI-MS在药品快检中的优势,从而为药品质检提供了潜在的高效、可靠的检测手段。  相似文献   

4.
The recently developed technique of desorption electrospray ionization (DESI) has been applied to the rapid analysis of controlled substances. Experiments have been performed using a commercial ThermoFinnigan LCQ Advantage MAX ion-trap mass spectrometer with limited modifications. Results from the ambient sampling of licit and illicit tablets demonstrate the ability of the DESI technique to detect the main active ingredient(s) or controlled substance(s), even in the presence of other higher-concentration components. Full-scan mass spectrometry data provide preliminary identification by molecular weight determination, while rapid analysis using the tandem mass spectrometry (MS/MS) mode provides fragmentation data which, when compared to the laboratory-generated ESI-MS/MS spectral library, provide structural information and final identification of the active ingredient(s). The consecutive analysis of tablets containing different active components indicates there is no cross-contamination or interference from tablet to tablet, demonstrating the reliability of the DESI technique for rapid sampling (one tablet/min or better). Active ingredients have been detected for tablets in which the active component represents less than 1% of the total tablet weight, demonstrating the sensitivity of the technique. The real-time sampling of cannabis plant material is also presented.  相似文献   

5.
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the direct analysis of liquid samples. Several interesting results were found. First, in contrast to the previous DESI analysis of dried solid samples that was limited to proteins with MW ≤25 kDa (Anal. Chem. 2007, 79, 3514), bovine serum albumin (BSA, 66 kDa) was successfully ionized from solutions by DESI with observation of corresponding multiply charged ions. Second, direct DESI analysis of protein tryptic digest solutions without chromatographic separation, sample clean-up, and the sample drying step was demonstrated, providing reasonably good sequence coverage of 52% to 97%. Third, direct analysis of biofluids such as an undiluted urine sample without sample pretreatment is possible, emphasizing the high tolerance of DESI with salt. These results suggest that a charged droplet pick-up mechanism is responsible for desorption and ionization of liquid samples by DESI. Also, unlike in electrospray ionization (ESI), inhibition of electrochemical reduction in the negative ion mode was observed for liquid sample DESI. In addition, reactive DESI can be performed with ion/ion reactions of Zn(II) complexes for the selective binding of phosphoserine in the presence of serine. DESI experiment can also be carried out directly to liquid samples flowing out of a pumped syringe needle tip, allowing rapid analysis. Furthermore, on-line coupling of electrochemical cell with DESI-MS was demonstrated, in which perylene radical cations generated in the cell were successfully transferred to the gas-phase for MS detection by DESI. This study extended the scope of DESI-MS applications, which could have potentials in bioanalytical and forensic analysis.  相似文献   

6.
Desorption electrospray ionization mass spectrometry (DESI-MS) and nuclear magnetic resonance (NMR) spectroscopy are used to provide data on urine examined without sample preparation to allow differentiation between diseased (lung cancer) and healthy mice. Principal component analysis (PCA) is used to shortlist compounds with potential for biomarker screening which are responsible for significant differences between control urine samples and samples from diseased animals. Similar PCA score plots have been achieved by DESI-MS and NMR, using a subset of common detected metabolites. The common compounds detected by DESI and NMR have the same changes in sign of their concentrations thereby indicating the usefulness of corroborative analytical methods. The effects of different solvents and surfaces on the DESI mass spectra are also evaluated and optimized. Over 80 different metabolites were successfully identified by DESI-MS and tandem mass spectrometry experiments, with no prior sample preparation.  相似文献   

7.
This paper reports use of a combination of Fourier-transform infrared (FTIR) spectroscopic imaging and desorption electrospray ionization linear ion-trap mass spectrometry (DESI MS) for characterization of counterfeit pharmaceutical tablets. The counterfeit artesunate antimalarial tablets were analyzed by both techniques. The results obtained revealed the ability of FTIR imaging in non-destructive micro-attenuated total reflection (ATR) mode to detect the distribution of all components in the tablet, the identities of which were confirmed by DESI MS. Chemical images of the tablets were obtained with high spatial resolution. The FTIR spectroscopic imaging method affords inherent chemical specificity with rapid acquisition of data. DESI MS enables high-sensitivity detection of trace organic compounds. Combination of these two orthogonal surface-characterization methods has great potential for detection and analysis of counterfeit tablets in the open air and without sample preparation.  相似文献   

8.
Serine,one of the nonessential amino acids,is of principal interest because of its capability to form magic-number ionic clusters,which provide a remarkable preference for homochirality.With L-aspartic acid as the precursor,this study provides experimental evidence for serine formation in weak acidified aqueous solutions in the presence of iron,with exposure to sunlight,which simulates the natural conditions of the prebiotic aqueous environment.The resultant mixture is directly analyzed via desorption electrospray ionization mass spectrometry(DESI-MS),without any sample preseparation.The serine monomer is successfully detected as protonated molecules,giving a peak at m/z 106,which is confirmed by the MS/MS fragments.Protonated serine octamer(m/z 841)is also observed with significant abundance in the MS spectra and is confirmed by the MS/MS data,which shows the formation of the serine octamer by a synthesized serine in the resultant mixture.It is also found that the serine octamer yielded equivalent abundance in the DESI mass spectra in a wide pH range(pH=1-5),and that existence of ferrous salt and sunshine are essential for the conversion of aspartic acid to serine in the acidic water solution.  相似文献   

9.
Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionization (DESI) mass spectrometry (MS). In this work the feasibility of DESI application for the rapid screening of intact esters of anabolic steroids in bovine hair has been studied. Using a linear ion trap both full scan and data-dependent collision induced dissociation MS(n) spectra were acquired in minutes for testosterone cypionate, testosterone decanoate and estradiol benzoate standard solutions deposited on a glass or PTFE surface. However direct analysis of incurred hair failed due to inefficient desorption ionization and the minute quantities of steroid esters present. Therefore a simplified ultrasonic liquid extraction procedure was developed, allowing rapid DESI analysis of a few microliters of the concentrate and a total analysis time of 2-4h per batch instead of 3 days. The potential of this DESI approach is clearly demonstrated by MS(3) data from hair samples incurred with high levels (300-800 μg kg(-1)) of steroid esters, levels which do occur in samples from controlled- and illegally treated animals. For much lower levels state-of-the-art ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) screening methods remain the method of choice and might benefit from the proposed simplified extraction as well.  相似文献   

10.
Implementation of desorption electrospray ionization (DESI) technique on a 9.4 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer is described. Desorption electrospray technique is capable of the direct investigation of natural samples without any need for sample preparation or chromatographic separation. Since the DESI mass spectra of natural samples are very complex owing to the lack of preseparation or cleanup, the ideal mass spectrometric analyzer for these applications is a high-resolution instrument such as FTICR mass spectrometer. DESI was implemented by constructing an electronically controlled source framework comprising six linear moving stages and one rotating stage. A three-dimensional linear stage was used to accommodate samples, while another 3D linear stage equipped with rotating stage was used as a spray mount. A modified electrosonic sprayer was used as a primary electrospray device. DESI-FTICR setup was characterized with regard to geometrical, electrical and flow conditions using deposited peptide samples in range of 1-100 pmol gross deposited amount on glass and polymer surfaces. Optimized conditions enabled the routine acquisition of DESI-MS spectra on the instrument at 130 000 resolution in the broadband mode and with comparable sensitivity to data reported in the literature. Since the main significance of DESI-FTICR MS is the combination of intact tissue analysis, the capabilities of the technique were demonstrated by analyzing murine liver samples. Presence of lysophospholipids in the liver tissue was tentatively associated with the lipid metabolism taking place in liver. DESI-FTICR is also a promising technique in the field of peptide analysis due to capability of top-down sequencing using electron capture dissociation. As a proof-of-principle experiment, a small synthetic polypeptide containing 36 amino acids was ionized using DESI and was sequenced in the FTICR by means of ECD (electron capture dissociation) fragmentation. Spectra gave almost full sequence information in agreement with the known amino acid sequence of the species.  相似文献   

11.
12.
The position of the surface to be analyzed relative to the sampling orifice or capillary into the mass spectrometer has been known to dramatically affect the observed signal levels in desorption electrospray ionization mass spectrometry (DESI‐MS). In analyses of sample spots on planar surfaces, DESI‐MS signal intensities as much as five times greater were routinely observed when the bottom of the sampling capillary was appropriately positioned beneath the surface plane (‘edge sampling’) compared with when the capillary just touched the surface. To take advantage of the optimum ‘edge sampling’ geometry and to maximize the number of samples that could be analyzed in this configuration, a rotational sample stage was integrated into a typical DESI‐MS setup. The rapid quantitative determination of caffeine in two diet sport drinks spiked with an isotopically labeled internal standard demonstrated the utility of this approach. Published in 2008 by John Wiley & Sons, Ltd.  相似文献   

13.
A source that couples the desorption ionization by charge exchange (DICE) and desorption electrospray ionization (DESI) techniques together was demonstrated to broaden the range of compounds that can be analyzed in a single mass spectrometric experiment under ambient conditions. A tee union was used to mix the spray reagents into a partially immiscible blend before this mixture was passed through a conventional electrospray (ES) probe capillary. Using this technique, compounds that are ionized more efficiently by the DICE method and those that are ionized better with the DESI procedure could be analyzed simultaneously. For example, hydroquinone, which is not detected when subjected to DESI-MS in the positive-ion generation mode, or the sodium adduct of guaifenesin, which is not detected when examined by DICE-MS, could both be detected in one experiment when the two techniques were combined. The combined technique was able to generate the molecular ion, proton and metal adduct from the same compound. When coupled to a tandem mass spectrometer, the combined source enabled the generation of product ion spectra from the molecular ion and the [M + H]+ or [M + metal]+ ions of the same compound without the need to physically change the source from DICE to DESI. The ability to record CID spectra of both the molecular ion and adduct ions in a single mass spectrometric experiment adds a new dimension to the array of mass spectrometric methods available for structural studies.  相似文献   

14.
Urine samples obtained from drug abusers were screened for drugs of abuse and their metabolites using DESI-MS and the results obtained were compared to results obtained from GC-MS experiments. The detected analyte classes included amphetamines, opiates, cannabinoids and benzodiazepines. The compounds detected were codeine, morphine, oxymorphone, 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol, Delta(9)-tetrahydrocannabinol, alprazolam, temazepam, oxazepam, N-desmethyldiazepam (nordiazepam) and hydroxytemazepam. Identities of all the analytes were confirmed by tandem mass spectrometry, matching MS/MS spectra with authentic standard compounds. The concentrations of the analytes in the samples were obtained from semi-quantitative GC-MS studies and were in the range of 270-22,000 ng mL(-1). The analytes could be detected by DESI even after a hundred-fold dilution indicating that the sensitivity of DESI was more than adequate for this study. Selectivity in the DESI-MS measurements for different kinds of analytes could be increased further by optimizing the spray solvent composition: the use of an entirely aqueous solvent enhanced the signal of polar analytes, such as the benzodiazepines, whereas the use of a spray solvent with a high organic content increased the signal of less polar analytes, such as codeine and morphine.  相似文献   

15.
Negative ion desorption electrospray ionization (DESI) was used for the analysis of an ex vivo tissue sample set comprising primary colorectal adenocarcinoma samples and colorectal adenocarcinoma liver metastasis samples. Frozen sections (12 μm thick) were analyzed by means of DESI imaging mass spectrometry (IMS) with spatial resolution of 100 μm using a computer-controlled DESI imaging stage mounted on a high resolution Orbitrap mass spectrometer. DESI-IMS data were found to predominantly feature complex lipids, including phosphatidyl-inositols, phophatidyl-ethanolamines, phosphatidyl-serines, phosphatidyl-ethanolamine plasmalogens, phosphatidic acids, phosphatidyl-glycerols, ceramides, sphingolipids, and sulfatides among others. Molecular constituents were identified based on their exact mass and MS/MS fragmentation spectra. An identified set of molecules was found to be in good agreement with previously reported DESI imaging data. Different histological tissue types were found to yield characteristic mass spectrometric data in each individual section. Histological features were identified by comparison to hematoxylin-eosin stained neighboring sections. Ions specific to certain histological tissue types (connective tissue, smooth muscle, healthy mucosa, healthy liver parenchyma, and adenocarcinoma) were identified by semi-automated screening of data. While each section featured a number of tissue-specific species, no potential global biomarker was found in the full sample set for any of the tissue types. As an alternative approach, data were analyzed by principal component analysis (PCA) and linear discriminant analysis (LDA) which resulted in efficient separation of data points based on their histological types. A pixel-by-pixel tissue identification method was developed, featuring the PCA/LDA analysis of authentic data set, and localization of unknowns in the resulting 60D, histologically assigned LDA space. Novel approach was found to yield results which are in 95% agreement with the results of classical histology. KRAS mutation status was determined for each sample by standard molecular biology methods and a similar PCA/LDA approach was developed to assess the feasibility of the determination of this important parameter using solely DESI imaging data. Results showed that the mutant and wild-type samples fully separated. DESI-MS and molecular biology results were in agreement in 90% of the cases.  相似文献   

16.
Desorption electrospray ionization mass spectrometry of intact bacteria   总被引:1,自引:0,他引:1  
Desorption electrospray ionization (DESI) mass spectrometry (MS) was used to differentiate seven bacteria species on the basis of their measured DESI-mass spectral profile. Both gram-positive and gram-negative bacteria were tested and included Escherichia coli, Staphyloccocus aureus, Enterococcus sp., Bordetella bronchiseptica, Bacillus thuringiensis, Bacillus subtilis and Salmonella typhimurium. Distinct DESI-mass spectra, in the mass range of 50-500 u, were obtained from whole bacteria in either positive or negative ion modes in less than 2 mins analysis time. Positive ion DESI-mass spectral fingerprints were compared using principal components analysis (PCA) to investigate reproducibility for the intraday and the day-to-day measurements and the method selectivity to differentiate the bacteria studied. Detailed study of variances in the assay revealed that a large contribution to the DESI-mass spectral fingerprint variation was the growth media preparation procedure. Specifically, experiments conducted with the growth media prepared using the same batch yielded highly reproducible DESI-mass spectra, both in intraday and in day-to-day analyses (i.e. one batch of growth media used over a 3-day period versus a new batch every day over the same 3-day period). Conclusions are drawn from our findings in terms of strategies for rapid biodetection with DESI-MS.  相似文献   

17.
江玮  喻钢 《分析测试学报》2012,31(4):430-435
自建了简易的电喷雾解吸电离源(DESI),优化了DESI源喷口的位置和角度,并将其用于常见多肽和蛋白质的分析。多肽和小质量蛋白质(<20 kDa)可以容易地从表面解吸电离,生成清晰的质谱。而牛血清白蛋白(66.4 kDa)不能产生清晰的多电荷分布的质谱,说明当前DESI源的设计可能存在一个电离的分子量上限。通过比较不同的实验条件并对比ESI-MS,发现溶剂分子的挥发过程对电荷分布以及峰宽均有显著影响,可能是由于ESI更软引起。载样表面的性质对DESI-MS的信号强度有较大影响。金表面的自组装单分子膜(SAM)相对于纯金表面有较好的绝缘性,并有助于产生较强信号,说明来自表面的电子转移(电中和)是电喷雾解吸电离过程中的一个重要因素。该文的研究有助于对DESI-MS的实验条件和载样表面的选择,同时增进了对电喷雾解吸电离机理的了解。  相似文献   

18.
Desorption electrospray ionization (DESI) mass spectrometry (MS) was used in an imaging mode to interrogate the lipid profiles of thin tissue sections of 11 sample pairs of human papillary renal cell carcinoma (RCC) and adjacent normal tissue and nine sample pairs of clear cell RCC and adjacent normal tissue. DESI-MS images showing the spatial distributions of particular glycerophospholipids (GPs) and free fatty acids in the negative ion mode were compared to serial tissue sections stained with hematoxylin and eosin (H&E). Increased absolute intensities as well as changes in relative abundance were seen for particular compounds in the tumor regions of the samples. Multivariate statistical analysis using orthogonal projection to latent structures treated partial least square discriminate analysis (PLS-DA) was used for visualization and classification of the tissue pairs using the full mass spectra as predictors. PLS-DA successfully distinguished tumor from normal tissue for both papillary and clear cell RCC with misclassification rates obtained from the validation set of 14.3% and 7.8%, respectively. It was also used to distinguish papillary and clear cell RCC from each other and from the combined normal tissues with a reasonable misclassification rate of 23%, as determined from the validation set. Overall DESI-MS imaging combined with multivariate statistical analysis shows promise as a molecular pathology technique for diagnosing cancerous and normal tissue on the basis of GP profiles.  相似文献   

19.
The imaging resolution of desorption electrospray ionization mass spectrometry (DESI-MS) was investigated using printed patterns on paper and thin-layer chromatography (TLC) plate surfaces. Resolution approaching 40 microm was achieved with a typical DESI-MS setup, which is approximately 5 times better than the best resolution reported previously. This improvement was accomplished with careful control of operational parameters (particularly spray tip-to-surface distance, solvent flow rate, and spacing of lane scans). In addition, an appropriately strong analyte/surface interaction and uniform surface texture on the size scale no larger than the desired imaging resolution were required to achieve this resolution. Overall, conditions providing the smallest possible effective desorption/ionization area in the DESI impact plume region and minimizing the analyte redistribution on the surface during analysis led to improved DESI-MS imaging resolution.  相似文献   

20.
Desorption electrospray ionisation (DESI) has been successfully combined with a hybrid quadrupole time-of-flight mass spectrometer to provide mass spectra and product ion mass spectra of active ingredients formulated in pharmaceutical tablets, gels and ointments. Accurate mass data has been obtained from the DESI mass spectra and of the product ion fragments of selected ions, greatly enhancing the selectivity and information content of the experiment. This accurate mass information only takes seconds to acquire since the DESI technique does not require any sample preparation or extraction prior to mass analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号