首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A simple stability-indicating reversed-phase liquid chromatographic method with diode-array detection was developed and validated for the quantitative determination of ebastine in tablets and syrup. The LC method was carried out on a C18 column with acetonitrile:phosphoric acid 0.1% pH 3.0 (55:45, v/v) as mobile phase, at a flow rate of 1.2 mL min−1. Ultraviolet detection of ebastine was at 254 nm. A linear response (r = 0.9999) was observed in the range of 10–80 μg mL−1. The RSD values for intra- and inter-day precision studies showed good results (RSD < 2%) and accuracy was greater than 98%. Validation parameters such as specificity and robustness were also determined. The method was found to be stability-indicating and can be applied to quantitative determination of ebastine in tablets and syrup.  相似文献   

2.
A simple, isocratic, stability-indicating liquid chromatographic method for quantitative determination of curcumin was successfully developed. The chromatographic separations were achieved using a Hi-Q-Sil C18; 4.6 mm × 250 mm and 10 μm particle size column employing acetonitrile and acetate buffer (pH 3.0; 60: 40, v/v) as the mobile phase. The analyte was subjected to acidic, basic, oxidative, thermal and photo degradation. The method was validated with respect to linearity, precision, accuracy, limit of detection and limit of quantification. Curcumin was detected by UV-Vis detector at 425 nm whereas the degradation products were detected at 280 nm. The method was linear over the concentration range of 1–10 μg mL?1. The limit of detection was found to be 0.06 μg mL?1 and the quantification limit was 0.21 μg mL?1. Considerable degradation of the analyte was observed when it was subjected to alkaline conditions. Accuracy, evaluated as recovery, was in the range of 97–103%. Intra-day precision and intermediate precision showed relative standard deviations <1% and <2% respectively.  相似文献   

3.

A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of rupatadine in pharmaceutical dosage forms. The LC method was carried out on a Gemini C18 column (150 mm × 4.6 mm I.D.), maintained at 30 °C. The mobile phase consisted of ammonium acetate buffer (pH 3.0; 0.01 M) with 0.05% of 1-heptanesulfonic acid–acetonitrile (71.5:28.5, v/v), run at a flow rate of 1.0 mL min−1 and using photodiode array (PDA) detection at 242 nm. The chromatographic separation was obtained with retention time of 5.15 min, and was linear in the range of 0.5–400 μg mL−1 (r = 0.9999). The specificity and stability-indicating capability of the method was proven through the degradation studies and showing also, that there was no interference of the excipients. The accuracy was 100.39% with bias lower than 0.58%. The limits of detection and quantitation were 0.01 and 0.5 μg mL−1, respectively. Moreover, method validation demonstrated acceptable results for precision, sensitivity and robustness. The proposed method was applied for the analysis of pharmaceutical dosage forms assuring the therapeutic efficacy.

  相似文献   

4.
A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of rupatadine in pharmaceutical dosage forms. The LC method was carried out on a Gemini C18 column (150 mm × 4.6 mm I.D.), maintained at 30 °C. The mobile phase consisted of ammonium acetate buffer (pH 3.0; 0.01 M) with 0.05% of 1-heptanesulfonic acid–acetonitrile (71.5:28.5, v/v), run at a flow rate of 1.0 mL min?1 and using photodiode array (PDA) detection at 242 nm. The chromatographic separation was obtained with retention time of 5.15 min, and was linear in the range of 0.5–400 μg mL?1 (r = 0.9999). The specificity and stability-indicating capability of the method was proven through the degradation studies and showing also, that there was no interference of the excipients. The accuracy was 100.39% with bias lower than 0.58%. The limits of detection and quantitation were 0.01 and 0.5 μg mL?1, respectively. Moreover, method validation demonstrated acceptable results for precision, sensitivity and robustness. The proposed method was applied for the analysis of pharmaceutical dosage forms assuring the therapeutic efficacy.  相似文献   

5.
This study focuses on a novel liquid chromatographic approach that has been developed and approved for the quantitative determination of bexarotene (BXT), its potential impurities in drug substances and drug products. Chromatographic separation was developed on a Symmetry C8 (150 × 4.6) mm 5-µm column with a mobile phase containing an isocratic mixture of acetonitrile:DI water:glacial acetic acid (650:350:7.5) v/v/v at a flow rate of 1.2 mL min?1, and quantitation was carried out using ultraviolet detection at 262 nm for BXT and 290 nm for BHA with a column temperature of 35 °C. The resolution among butylated hydroxyanisole (BHA), BXT and its process-related impurity-A was found to be greater than 5. Regression analysis confers an R value (correlation coefficient) higher than 0.998 for BHA, BXT and impurity-A. The detection level for BXT impurities was found at a level below 0.03% (0.18 µg mL?1). The inter- and intra-day precisions for BHA, BXT and impurities were evaluated and found to have a %RSD of less than 3.0.  相似文献   

6.

A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08–5.70 μg mL−1 (= 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 μg mL−1, respectively.

  相似文献   

7.
A novel stability indicating LC method was developed and validated for the quantitative determination of riluzole in bulk drugs and in pharmaceutical dosage forms in the presence of its isomers, related substances and degradation products. The drug was subjected to stress conditions of hydrolysis (acid, base and neutral), oxidation, photolysis and thermal degradation. Considerable degradation was observed under base hydrolysis and oxidation. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.5%. The developed method was validated with respect to linearity, accuracy, precision, specificity, ruggedness and robustness.  相似文献   

8.
9.
A simple, precise, and accurate HPLC method has been developed and validated for assay of ezetimibe in tablets and for determination of content uniformity. Reversed-phase liquid chromatographic separation was achieved by use of phosphoric acid (0.1%, v/v)–acetonitrile 50:50 (v/v) as mobile phase. The method was validated for specificity, linearity, precision, accuracy, robustness, and solution stability. The specificity of the method was determined by assessing interference from the placebo and by stress testing of the drug (forced degradation). Response was a linear function of drug concentration in the range 20–80 μg mL−1 (r = 0.9999). Intraday and interday system and method precision were determined. Accuracy was between 100.8 and 102.7%. The method was found to be robust, and was suitable for assay of ezetimibe in a tablet formulation and for determination of content uniformity. An erratum to this article can be found at  相似文献   

10.
A stability-indicating reversed-phase high-performance liquid chromatography (LC) method was developed and validated for the determination of hydrochlorothiazide in an oral suspension. Isocratic chromatography was performed on a C18 column with 0.1 M sodium phosphate buffer pH 3.0/acetonitrile (70:30 v/v) as mobile phase, at a flow rate of 1.3 mL min−1, and UV detection at 254 nm. The method was linear (r 2 = 0.9998), accurate (mean recovery = 100.3%), and precise (RSD <2%). It was also validated for specificity and robustness. The method was successfully applied for the quality control analysis of a new pharmaceutical formulation of HCTZ for pediatric use.  相似文献   

11.
JPC – Journal of Planar Chromatography – Modern TLC - A sensitive, selective, precise, and stability-indicating high-performance thin-layer chromatography (HPTLC) method for the...  相似文献   

12.
13.
A reversed-phase liquid chromatographic (LC) method was developed for the assay of nitazoxanide (NTZ) in solid dosage formulations. An isocratic LC separation was performed on a Phenomenex Synergi Fusion C18 column (250 mm × 4.6 mm, i.d., 4 μm particle size) using a mobile phase of 0.1% o-phosphoric acid solution, pH 6.0: acetonitrile (45:55, v/v) at a flow rate of 1.0 mL min−1. Detection was achieved with a photodiode array detector at 240 nm. The detector response for NTZ was linear over the concentration range from 2 to 100 μg mL−1 (r = 0.9999). The specificity and stability-indicating capability of the method were proved using stress conditions. The RSD values for intra-day precision were less than 1.0% for tablets and powder for oral suspension. The RSD values for inter-day precision were 0.6 and 0.7% for tablets and powder for oral suspension. The accuracy was 100.4% (RSD = 1.8%) for tablets and 100.9% (RSD = 0.3%) for powder for oral suspension. The limits of quantitation and detection were 0.4 and 0.1 μg mL−1. There was no interference of the excipients on the determination of the active pharmaceutical ingredient. The proposed method was precise, accurate, specific, and sensitive. It can be applied to the quantitative determination of drug in tablets and powder for oral suspension.  相似文献   

14.
15.

A simple, rapid, and precise method is developed for the quantitative determination of lumefantrine (Lume) in active pharmaceutical ingredient (API). A chromatographic separation of Lume and its degradants were achieved with an X-Terra RP18, 250 × 4.6 mm, and 5 μ analytical column using buffer–acetonitrile (30:70 v/v). The buffer used in mobile phase contains 0.1 M sodium perchlorate monohydrate in double distilled water pH adjusted to 2.1 with trifluoroacetic acid. The instrumental settings are flow rate of 0.5 mL (L), column temperature at 35 °C, and detector wavelength of 235 nm using a photodiode array detector. Lume was exposed to thermal, photolytic, hydrolytic and oxidative stress conditions, and the stressed samples were analysed by the proposed method. Peak homogeneity data of Lume obtained by photodiode array detection, in the stressed sample chromatograms, demonstrated the specificity of the method for estimation in the presence of degradants. The described method shows excellent linearity over a range of 10–200 μg L−1 for Lume. The correlation coefficient is 1. The relative standard deviation of peak area for six measurements is always less than 2% between days. The proposed method was found to be suitable and accurate for quantitative determination and stability study of Lume in API.

  相似文献   

16.
A simple, inexpensive and rapid isocratic LC method has been developed for the quantative determination of Rimonabant, an anti-obesity drug. The method can also be employed for the determination of Rimonabant and its impurities in the bulk drug. Degradation studies were performed on the bulk drug by heating to 60 °C, exposure to UV light at 254 nm, acid (0.5 N hydrochloric acid), base (0.5 N sodium hydroxide) and aqueous hydrolysis and oxidation with 3.0% v/v hydrogen peroxide. Considerable degradation was observed under oxidation conditions. Good resolution between the peaks corresponding to impurities produced during synthesis, degradation products and the analyte was achieved on a Phenomenex Gemini C18 LC column using a mobile phase consisting of a mixture of aqueous potassium dihydrogen phosphate (pH 3.0) and acetonitrile. The degradation samples were assayed against the reference standard of Rimonabant and the mass balance in each case was close to 99.5%. Validation of the method was carried out as per ICH requirements.  相似文献   

17.
A stability-indicating reversed-phase LC method for analysis of aceclofenac and paracetamol in tablets and in microsphere formulations has been developed and validated. The mobile phase was 80:20 (v/v) methanol–phosphate buffer (10 mM at pH 2.5 ± 0.02). UV detection was at 276 nm. The method was linear over the concentration ranges 16–24 and 80–120 μg mL?1 for aceclofenac and paracetamol, respectively, with recovery in the range 100.9–102.22%. The limits of detection and quantitation for ACF were 0.0369 and 0.1120 μg mL?1, respectively; those for PCM were 0.0631 and 0.1911 μg mL?1, respectively.  相似文献   

18.

This paper discusses the development of a stability-indicating reversed-phase LC method for analysis of cholecalciferol as the bulk drug and in formulations. The mobile phase was acetonitrile–methanol–water 50:50:2 (v/v). The calibration plot for the drug was linear in the range 0.4–10 μg mL−1. The method was accurate and precise with limits of detection and quantitation of 64 and 215 ng, respectively. Mean recovery was 100.71%. The method was used for analysis of cholecalciferol in pharmaceutical formulations in the presence of its degradation products and commonly used excipients.

  相似文献   

19.
A simple, isocratic, rapid, and accurate reversed-phase high-performance liquid chromatographic method has been established for quantitative determination of zonisamide. The method is also applicable to determination of related substances in the bulk drug. Chromatographic separation was achieved on a 250 mm × 4.6 mm, 5-μm particle, C18 column; the mobile phase was a 70:30 (v/v) mixture of 0.1% (v/v) aqueous triethylamine, adjusted to pH 2.5 with dilute orthophosphoric acid, and acetonitrile. Chromatographic resolution of zonisamide from its potential impurity, A, was found to be >2. The limits of detection and quantification of zonisamide and impurity A were 0.04 and 0.12 μg mL?1, respectively, for 20 μL injection volume. Recovery of zonisamide ranged from 98.5 to 101.2% and recovery of impurity A from a sample of zonisamide ranged from 97.4 to 102.7%. The method was validated for linearity, accuracy, precision, and robustness.  相似文献   

20.
A stability-indicating HPLC method for the quantitative determination of Bicalutamide is described. Bicalutamide is a nonsteroidal antiandrogen and is an oral medication that is used for treating prostate cancer. Separation was achieved on a Waters Symmetry shield RP18 HPLC column using a mobile phase consists of a mixture of phosphate buffer (Solvent A) and organic modifier acetonitrile (Solvent B). Degradation studies were performed on bulk samples of bicalutamide using acid (0.5 N methanolic hydrochloric acid), base (0.5 N methanolic sodium hydroxide), oxidation (10% v/v methanolic hydrogen peroxide), heat (60 °C) and UV light (254 nm). Degradation was observed under base hydrolysis to give the starting material used during the synthesis of bicalutamide. The degraded samples were assayed and gave a mass balance greater than 99.5%, thus proving the stability-indicating power of the developed method. The method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号