首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In order to develop a robust and easy-to-use technique for characterization of bacterial polysaccharides, a pseudo-hydrolysis strategy was investigated. Based on in-source collision-induced dissociation, polysaccharide molecular ions were fragmented within the orifice-skimmer region of an electrospray ionization (ESI) mass spectrometer. The fragment ions thus generated were then analyzed similarly to the conventional ESI mass spectrometry approach. MS/MS scanning was applied to obtain product-ion spectra of the primary fragments for sequencing. To further improve the sensitivity and separation of polysaccharides from other components in the samples, a pressure-assisted capillary electrophoresis/mass spectrometry (CE/MS) system was employed. Using bacterial polysaccharides as model compounds, the mass spectra obtained for polysaccharide repeating units generated through chemical hydrolysis and in-source fragmentation were directly compared, both in positive and negative ion modes. With the additional separation of impurities provided by CE, the success of this technique has been demonstrated for structural analysis of O-chain polysaccharides (O-PS) and capsular polysaccharides (CPS). In-source fragmentation was applied to promote the formation of structurally relevant repeating units of heterogeneous CPS that would remain undetected using conventional ESI conditions. This approach was proven to be particularly useful for probing the subtle structural differences in monosaccharide composition and functionalities arising across bacterial serotypes.  相似文献   

2.
The analytical hyphenation of micro-flow high-performance liquid chromatography (LC), with post-column liquid mixing and mass spectrometric detection (MS) was established to detect partially oxidized polycyclic aromatic hydrocarbons (oxy-PAHs) for low quantity samples. 100pmol injections of 30 reference standards could be detected in good sensitivity using either atmospheric pressure chemical ionization (APCI) and/or atmospheric pressure photoionization (APPI). The connected mass spectrometer was a single quadrupol analyzer realizing simultaneous registration of positive and negative ions in scan range width of 200 - 300Da. The ionization efficiency was compared using three ionization sources (incl. electrospray ionization (ESI)) for several oxy-PAHs. According to the mass spectra, the analytes behave differently in ionization properties. Ionization mechanism (e.g. deprotonated ions and electron captured ions) could be discussed with new inside views. Finally, the hyphenated system was applied to an exemplary aerosol extract and thus highlighting the expedient utilization of this downscaled method for real samples.  相似文献   

3.
A novel method for analysing polysaccharide materials is described which employs size-exclusion chromatography (SEC) followed by detection by on-line electrospray ionisation mass spectrometry (ESI-MS) and off-line matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). It is demonstrated through SEC/ESI ion trap mass spectrometry that the formation of multiply charged oligomer ions, which bind up to five sodium cations, allows the rapid analysis of polysaccharide ions with molecular weights in excess of 9 kDa. MALDI spectra generated from fractionation of the effluent collected from the same SEC separation are shown to be in good agreement with the ESI spectra with respect to molecular weight distributions and types of ions generated. ESI and MALDI mass spectra of samples obtained from sequential graded ethanol precipitation and SEC fractionation of acid and enzymatically digested arabinoxylan polysaccharides show important structural differences between polysaccharide fragments. In addition, a comparison is made between the mass spectra of native and permethylated SEC-separated fragments of acid and enzymatically treated arabinogalactan. Linkage information of the permethylated arabinogalactan oligomers can be rapidly established through the use of on-line SEC/ESI-MS( n) experiments.  相似文献   

4.
Metal salen complexes are one of the most frequently used catalysts in enantioselective organic synthesis. In the present work, we compare a series of ionization methods that can be used for the mass spectral analysis of two types of metalosalens: ionic complexes (abbreviated as Com+X?) and neutral complexes (NCom). These methods include electron ionization and field desorption (FD) which can be applied to pure samples and atmospheric pressure ionization techniques: electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) which are suitable for solutions. We found that FD is a method of choice for recording molecular ions of the complexes containing even loosely bonded ligands. The results obtained using atmospheric pressure ionization methods show that the results depend mainly on the structure of metal salen complex and the ionization method. In ESI spectra, Com+ ions were observed, while in APCI and APPI spectra both Com+ and [Com + H]+ ions are observed in the ratio depending on the structure of the metal salen complex and the solvent used in the analysis. For complexes with tetrafluoroborate counterion, an elimination of BF3 took place, and ions corresponding to complexes with fluoride counterion were observed. Experiments comparing the relative sensitivity of ESI, APCI and APPI (with and without a dopant) methods showed that for the majority of the studied complexes ESI is the most sensitive one; however, the sensitivity of APCI is usually less than two times lower and for some compounds is even higher than the sensitivity of ESI. Both methods show very high linearity of the calibration curve in a range of about 3 orders of magnitude of the sample concentration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
A sonic spray ionization liquid chromatography/mass spectrometry (LC/SSI-MS) procedure combined with off-line solid-phase extraction was optimized for the analysis of 20 endocrine-disrupting chemicals (EDCs) in water samples. Method development included a comparison of the novel sonic spray ionization (SSI) with more traditional ion sources, i.e. pneumatically assisted electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). It was demonstrated that SSI and ESI spectra were very similar, but were more prone to the formation of solvent cluster ions as compared with APCI spectra. This phenomenon was most prominent for SSI and resulted in an increased chemical background in full-scan mass spectra. However, this chemical noise did not affect the overall sensitivity of SSI and ESI. After optimization of LC and MS parameters, the LC/SSI-MS method was validated. Recoveries ranged from 76.3 up to 113.4% for all compounds. Limits of detection (LOD) and quantitation (LOQ) were established between 3.0 and 11.5 ng/L and 9.9 and 38.0 ng/L, respectively. Within-day (n = 5) and between-day (n = 5) reproducibility were investigated at three levels and ranged from 3.3-16.5% and 7.6-19.2%, respectively. Eight-point calibration curves were established and showed linearity for all compounds (r(2) > 0.987) over a linear dynamic range of 10-10 000 ng/L.  相似文献   

6.
The capabilities of atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) methods for quantitative analysis of polar and ionic compounds in petroleum fractions have been examined. The requirements of the analysis for sensitivity, linear dynamic range, and structural characterization have been discussed. ESI was found to be approximately two orders of magnitude more sensitive than APCI and is most suitable for the detection of analytes in weak concentrations. Equivalent relative linear dynamic ranges were observed by the two methods (at least three orders of magnitude). For the relatively high analyte concentrations examined here (e.g., 1-100 ppm or higher), the absolute area counts increased linearly with the analyte amount only in APCI, making this method more attractive for quantitative liquid chromatography/mass spectrometry (LC/MS) applications. Nevertheless, a wider range of ionic compounds can be detected by ESI than by APCI.  相似文献   

7.
Factors affecting the sensitivity and selectivity of the determination of diuretics, anabolic steroids, central nervous system stimulants, and narcotics in the analysis of human urine extracts by high-performance liquid chromatography-tandem mass spectrometry with atmospheric pressure electrospray ionization and recording of positive ions were investigated. Mass spectra were obtained for all of the test compounds; the characteristic ions, retention times, detection limits, degree of ionization suppression by the matrix, the extraction of the analytes from human biological fluids were determined for all analytes; the selectivity and specificity of determination were evaluated.  相似文献   

8.
Electrospray ionization mass spectrometry (ESI‐MS) is a useful technique for solving organometallic and coordination chemistry characterization problems that are difficult to address using traditional methods. However, assigning the ESI mass spectra of such compounds can be challenging, and the considerations involved in doing so are quite different from assigning the mass spectra of purely organic samples. This is a tutorial article for organometallic/coordination chemists using ESI‐MS to analyze pure compounds or reaction mixtures. The fundamentals of assigning ESI mass spectra are discussed within the context of organometallic and coordination systems. The types of ions commonly observed by ESI‐MS are categorized and described. Finally, a step‐by‐step guide for the assignment of organometallic and coordination chemistry ESI mass spectra is provided along with two case studies.  相似文献   

9.
We describe the use of electrospray-assisted pyrolysis ionization/mass spectrometry (ESA-Py/MS) to selectively ionize trace polar compounds that coexist with large amounts of nonpolar hydrocarbons in crude oil, amber, humic substances, and rubber samples. Samples of different origins are distinguished rapidly by their positive ion ESA-Py mass spectra without prior separation or chemical pretreatment. During ESA-Py analysis, the samples in their solid or liquid states were pyrolyzed at 590, 630 or 940 degrees C using a commercial Curie-point pyrolysis probe. The gaseous pyrolysates were transferred into a glass reaction cell. The polar compounds (M) in the pyrolysates were then ionized by electrospray ionization (ESI), yielding protonated molecules (MH+). Although the major components of the pyrolysates are nonpolar hydrocarbons, their lack of functional groups that can receive a proton in the ESA-Py source results in no hydrocarbon ion signals being produced; thus, the positive ions detected in ESA-Py mass spectra all result from trace polar components in the pyrolysates.  相似文献   

10.
Six synthesized 6-nitroquipazine derivatives were examined by electron ionization (EI) and electrospray ionization (ESI) mass spectrometry in positive and negative ion mode. The compounds exhibit high affinity for the serotonin transporter (SERT) and belong to a new class of SERT inhibitors. The EI mass spectra registered in negative ion mode showed prominent molecular ions for all the compounds studied. All EI mass spectra and all ESI mass spectra showed similar fragmentation pathways of molecular ions, but the pathways differed between EI and ESI. The differences were explained with the aid of theoretical evaluation of the stability of the respective radical ions (EI MS) and protonated ions (ESI MS).  相似文献   

11.
In this study, a polarization‐induced electrospray ionization mass spectrometry (ESI‐MS) was developed. A micro‐sized sample droplet was deposited on a naturally available dielectric substrate such as a fruit or a stone, and then placed close to (~2 mm) the orifice of a mass spectrometer applied with a high voltage. Taylor cone was observed from the sample droplet, and a spray emitted from the cone apex was generated. The analyte ion signals derived from the droplet were obtained by the mass spectrometer. The ionization process is similar to that in ESI although no direct electric contact was applied on the sample site. The sample droplet polarized by the high electric field provided by the mass spectrometer initiated the ionization process. The dielectric sample loading substrate facilitated further the polarization process, resulting in the formation of Taylor cone. The mass spectral profiles obtained via this approach resembled those obtained using ESI‐MS. Multiply charged ions dominated the mass spectra of peptides and proteins, whereas singly charged ions dominated the mass spectra of small molecules such as amino acids and small organic molecules. In addition to liquid samples, this approach can be used for the analysis of solid and viscous samples. A small droplet containing suitable solvent (5–10 µl) was directly deposited on the surface of the solid (or viscous) sample, placed close the orifice of mass spectrometer applied with a high voltage. Taylor cone derived from the droplet was immediately formed followed by electrospray processes to generate gas‐phase ions for MS analysis. Analyte ions derived from the main ingredients of pharmaceutical tablets and viscous ointment can be extracted into the solvent droplet in situ and observed using a mass spectrometer. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
A novel strategy was developed to extend the application of electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) to the analysis of long-chain polysaccharides. High molecular weight polydisperse maltodextrins (poly-alpha(1-4) glucose) and dextrans (poly-alpha(1-6) glucose) were chosen as model compounds in the present study. Increased ionization efficiency of these mixtures in the positive ion mode was achieved upon modification of their reducing end with nitrogen-containing groups. The derivatization method is based on the formation of a new C--N bond between 1,6-hexamethylenediamine (HMD) and the reducing end of the polysaccharide, which exists in solution as an equilibrium between the hemiacetal and the open-ring aldehyde form. To achieve the chemical modification of the reducing end, two synthetic pathways were developed: (i) coupling of HMD by reductive amination and (ii) oxidation of the hemiacetal to lactone, followed by ring opening by HMD to yield the maltodextrin lactonamide of 1,6-hexanediamine (HMMD). Amino-functionalized polysaccharides were analyzed by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FTICR-MS) in the positive ion mode by direct flow injection. The hexamethylenediamine (HMD) and maltodextrin lactonamide of 1,6-hexanediamine (HMMD) moieties provide increased proton affinities which dramatically improve the detection of the long-chain polysaccharides by FTICR-MS. The present approach allowed for identification of single components in mixtures with prominent heterogeneity in the degree of polymerization (DP), without the need for chromatographic separation prior to MS. The high mass accuracy was essential for the unambiguous characterization of the species observed in the analyzed mixtures. Furthermore, molecular components containing up to 42 glucose residues were detected, representing the largest polysaccharide chains analyzed so far by ESI FTICR-MS.  相似文献   

13.
Purines and pyrimidines are of interest owing to their significance in processes in living organisms. Mass spectrometry is a promising analytical tool utilized in their analysis. Two atmospheric pressure ionization (API) methods (electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI)) in both negative and positive modes applied to selected purine and pyrimidine metabolites (markers of inherited metabolic disorders) were studied. APCI is less sensitive to alkali metal cations present in a sample and offers higher response than ESI for studied compounds. Both of the techniques afford quasi-molecular ions, but fragmentation also occurs to a certain extent. However, the application of collision-induced dissociation of quasi-molecular ions is essential to confirm a certain metabolite in a sample. Fragmentation of both positive and negative ions was evaluated using multi-stage mass spectrometric experiments. Typical neutral losses correspond to molecules NH(3), H(2)O, HCN, CO, H(2)NCN, HNCO and CO(2). The ion [NCO](-) arises in the negative mode. The cleavage of the glycosidic C-N bond is characteristic for relevant metabolites. Other neutral losses (CH(2)O, C(2)H(4)O(2) and C(3)H(6)O(3)) originate from fragmentation of the glycosidic part of the molecules. In addition to fragmentation, the formation of adducts of some ions with applied solvents (H(2)O, CH(3)OH) was observed. The composition of the solution infused into the ion source affects the appearance of the mass spectra. Tandem mass spectra allow one to distinguish compounds with the same molecular mass (uridine-pseudouridine and adenosine-2'-deoxyguanosine). Flow injection analysis APCI-MS/MS was tested on model samples of human urines corresponding to adenosine deaminase deficiency and xanthine oxidase deficiency. In both cases, the results showed potential diagnostic usefulness.  相似文献   

14.
We have studied the behavior of ferrocene CpFeCp (FcH), ferrocenium triiodide [FcH]+I3, dimethylaminomethylferrocene FcCH2NMe2 and its trimethylammonium salt [FcCH2NMe3]+I under the conventional conditions of electrospray ionization (ESI), when the substance solution is subjected to spraying, and in two versions of desorption electrospray ionization (DESI), when the sprayed solvent bombards the surface of solid or liquid samples. In addition to these techniques, the behavior of neutral compounds under conditions of electrospray ionization of vapors of the studied compounds in a gas phase (ESI_V) has been investigated. It has been shown using the examples of ferrocene and its dimethylaminomethyl derivative that the detection limits for these compounds occurring in a gas phase are comparable within an order of magnitude with their detection limits under the ESI and DESI conditions of solid and liquid samples. The high effectiveness of ionization of analyte vapors makes it possible to use the ESI method not only in combination with liquid (conventional ESI technology) and thin layer chromatography (DESI), but also with gas liquid chromatography (ESI_V). Thus, the electrospray ionization becomes a universal method allowing studies of a compound under the natural conditions in any state of aggregation, that is, solid, liquid, and gas. With the help of statistical methods for designing experiments (complete factorial experiment), quantitative evaluation of the influence of experimental parameters on the ion-formation processes under different ESI conditions has been carried out, which makes it possible to purposefully select the optimal conditions to record the ESI mass spectra with a minimum number of experiments. Moreover, analysis of the dependences of the mass spectra on the experimental parameters can serve as an instrument for studying the details of the ion-formation mechanisms depending upon different ways of ionization.  相似文献   

15.
Mass spectra of transition metal carbonyl cluster anions were recorded using laser desorption ionization time-of-flight (LDI-TOF) and electrospray ionization (ESI) techniques. The LDI spectra generally contain peaks corresponding the intact cluster together with extensive CO loss fragments ions whereas the ESI spectra exhibit peaks corresponding the intact cluster together with few (if any) CO loss fragment ions. The parameters of both techniques can be modified to vary the extent of fragmentation. In all cases no fragmentation of the metal core is observed. Overall, ESI is a more informative method for the analysis of these types of cluster anions.  相似文献   

16.
Electrospray ionization (ESI) and liquid secondary ionization (LSI) mass spectrometry were applied for characterization of glycosphingolipids (GSLs) isolated in their peracetylated form from four Agelas marine sponge species. Since peracetylated glycosphingolipids are not soluble in solvents traditionally used for ESI, lithium chloride was added to the samples in order to obtain lithium cationized molecules. Although the preferred fragmentation seems to be the sequential loss of acetic acid molecules, it was found that tandem mass spectra obtained from peracetylated diglycosyl ceramides might provide direct information about the structure of the long-chain base (formation of W'/Z0 fragments). The utility of ESI and LSI in the analysis of these compounds has also been compared. It was found that the tandem mass spectra obtained by LSI-MS/MS experiments could provide information about the chain-length (carbon atom number) variations within a certain ceramide mass. Thus, from one of our samples, 25 different ceramide compositions have been identified from 8 precursor (Z0) ions. Comparison of the two ionization modes (LSI and ESI) highlights the fact that molecular mass distributions obtained by LSI-MS, especially the presence of unsaturated species, have to be interpreted carefully. For the first time a direct high-performance liquid chromatography (HPLC)/ESI-MS method was used for characterization of complex mixtures of peracetylated GSLs. The results demonstrate that HPLC/ESI-MS is able to analyze mono- and diglycosylated GSLs, and other kinds of glycolipids that are actually present in the sample.  相似文献   

17.
Characterization of triglycerides in vegetable oils was achieved by silver-ion packed-column supercritical fluid chromatography (SI-pSFC) with mass spectrometric detection. Hyphenation was made using commercially available liquid chromatography-mass spectrometry (LC-MS) interfaces without any modification. A make-up fluid was delivered through a T-piece placed before or after the SFC restrictor by means of a high pressure pump. Atmospheric pressure chemical ionization (APCI) and coordination ion spray (CIS) with silver ions were used as ionization modes. Compared to UV detection, the sensitivity was increased by a factor of 100. Both ionization modes are generating similar structural information. Molecular ions [M-H]+ or [M-Ag(-)] are observed in the mass spectra with exception of the saturated triglycerides for which only CIS gives intense molecular ions. The position at which the fatty acids are esterified to the glycerol backbone can be elucidated by pSFC-APCI although it remains speculative whether this is valid for highly unsaturated triglycerides because reference compounds are not available to proof this.  相似文献   

18.
High-performance liquid chromatography-diode array detection (HPLC-DAD), electrospray ionization time-of-flight mass spectrometry (HPLC-ESI-TOF-MS) and electrospray ionization quadrupole ion trap mass spectrometry (HPLC-ESI-MSn) were used for the isolation, identification and structural analysis of water-soluble phenolic and nonpolar diterpenoid constituents in Dan-shen (Radix Salvia miltiorrhizae) which was prepared by sonication in 70% methanol. Mass spectra were obtained by ESI-TOF-MS and electrospray ionization quadrupole ion trap mass spectrometry (ESI-QIT-MS). A formula database of known constituents in Dan-shen was established and most constituents were rapidly identified by HPLC-DAD/ESI-TOF-MS by matching their accurate molecular masses with the formulae of the compounds in the database. Compounds with the same molecular formula could not be differentiated by TOF-MS; however, QIT-MS could differentiate those compounds and elucidate their structures based on their characteristic fragmentation. HPLC-DAD, HPLC/ESI-TOF-MS and HPLC/ESI-MSn provided complementary information for the identification of the constituents in Dan-shen. Forty constituents were identified in 30 min based on their positive and negative ion ESI mass spectra and liquid chromatographic information. Thus the method described is useful for the rapid analysis of multiple constituents in Dan-shen.  相似文献   

19.
Liquid ionization mass spectrometry of some triorganotin carboxylates.   总被引:1,自引:0,他引:1  
and ESI, in which [M + H]+ were not observed or the spectra were complicated. The liquid ionization mass spectra of triorganotin carboxylates varied with solvents and sample concentrations. For instance, the fragment ions [M + (C4H9)3Sn]+ of dimeric ions were observed with chloroform used as a solvent, while the [M + H]+ were observed as the base peak using ethylene dichloride. Spectra useful for the differentiation of isomers [CgH7O3Sn(C4Hg)3] were obtained by the formation of characteristic adduct ions, such as [M + EA + H]+ and [M + 2EA + H]+, with a reagent like 2-aminoethanol. Collision-induced dissociation (CID) spectra observed by ESI and LPI mass spectrometry were similar and provided less information than adduct ions did.  相似文献   

20.
Mass spectrometric fragmentation pathways of title compounds were studied by electron ionization (EI) and electrospray ionization (ESI) as methods of ion generation. To explain the observed complex skeletal rearrangements, tandem mass spectrometry, accurate mass measurement and isotope labeling (compounds containing one 13C atom in oxadiazole ring) were used. Loss of CO, N2 and H atoms under EI conditions led to the formation of 9,10-dihydroacridine-type ions, loss of NH3 under ESI conditions yielded the 4-phenylphthalazinone-type ions and the loss of HNCO under ESI conditions produced N-arylamino-benzonitrilium ions; however, this process can be affected by the electron-donor/electron-withdrawing properties of groups substituted at the phenyl rings. The ESI was used to study the complexes of the compounds with cobalt as well as with cyclodextrin. It was found that the compounds studied tend to form inclusion complexes with cyclodextrin of stoichiometry 1:1 and complexes of different stoichiometries with cobalt, although those of stoichiometry 6:1 and 4:1 are favored and the attachment of counter ion may stabilize the complexes 3:1 and 2:1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号