首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive, simple method for quantification of chloroquine (CQ) and desethylchloroquine (MCQ) in whole blood and plasma from Plasmodium vivax patients has been developed using HPLC with diode array detection (DAD). Solid‐phase extraction on Isolute‐96‐CBA was employed to process 100 μL of plasma/whole blood samples. CQ, MCQ and quinine were separated using a mobile phase of phosphate buffer 25 mm , pH 2.60–acetonitrile (88:12, v/v) with 2 mm sodium perchlorate on a Zorbax SB‐CN 150 × 4.6 mm, 5 μm column at a flow rate of 1.2 mL/min, at ambient temperature in 10 min, with the DAD wavelength of 343 nm. The method was linear over the range of 10–5000 ng/mL for both CQ and MCQ in plasma and whole blood. The limit of detection was 4 ng/mL and limit of quantification was 10 ng/mL in both plasma and blood for CQ and MCQ. The intra‐, inter‐ and total assay precision were <10% for CQ and MCQ in plasma and whole blood. In plasma, the accuracies varied between 101 and 103%, whereas in whole blood, the accuracies ranged from 97.0 to 102% for CQ and MCQ. The method is an ideal technique with simple facilities and instruments, bringing about good separation in comparison with previous methods. © 2016 The Authors Biomedical Chromatography Published by John Wiley & Sons Ltd  相似文献   

2.
《Electrophoresis》2017,38(7):1075-1082
In this study, novel, fast, and simple methods based on RP‐HPLC and MEKC with DAD are developed and validated for the qualitative and quantitative determination of five cyclic sulfur mustard (HD) degradation products (1,4‐thioxane, 1,3‐dithiolane, 1,4‐dithiane, 1,2,5‐trithiepane, and 1,4,5‐oxadithiepane) in water samples. The HPLC method employs a C18 column and an isocratic water‐ACN (55:45, v/v) mobile phase. This method enables separation of all five cyclic compounds within 8 min. With the CE method, the baseline separation of five compounds was achieved in less than 11 min by applying a simple BGE composed of a 10 mM borate buffer and 90 mM SDS (pH 9.15). Both methods showed good linear correlation (R 2 > 0.9904). The detection limits were in the range of 0.08–0.1 μM for the HPLC method and 10–20 μM for MEKC. The precision tests resulted in RSDs for migration times and peak areas less than 0.9 and 5.5%, respectively, for the HPLC method, and less than 1.1 and 7.7% for the MEKC method, respectively. The developed methods were successfully applied to the analysis of five cyclic HD degradation products in water samples. With the HPLC method, the LODs were lowered using the SPE for sample purification and concentration.  相似文献   

3.
A fully valid UHPLC–MS/MS method was developed for the determination of etoposide, gemcitabine, vinorelbine and their metabolites (etoposide catechol, 2′,2′‐difluorodeoxyuridine and 4‐O ‐deacetylvinorelbine) in human plasma. The multiple reaction monitoring mode was performed with an electrospray ionization interface operating in both the positive and negative ion modes per compound. The method required only 100 μL plasma with a one‐step simple de‐proteinization procedure, and a short run time of 7.5 min per sample. A Waters ACQUITY UPLC HSS T3 column (2.1 × 100 mm, 1.8 μm) provided chromatographic separation of analytes using a binary mobile phase gradient (A, 0.1% formic acid in acetonitrile, v /v; B, 0.1% formic acid in water, v /v). Linear coefficients of correlation were >0.995 for all analytes. The relative deviation of this method was <10% for intra‐ and inter‐day assays and the accuracy ranged between 86.35% and 113.44%. The mean extraction recovery and matrix effect of all the analytes were 62.07–105.46% and 93.67–105.87%, respectively. This method was successfully applied to clinical samples from patients with lung cancer.  相似文献   

4.
Carbamazepine is an antiepileptic drug widely used for the treatment of epilepsy. In the National Institute of Neurology, monitoring has been performed using the technique chemiluminescent microparticle immunoassay (CMIA) in an automated way during the last five years. The aim of this study was to develop a simple and rapid HPLC analytical method coupled to DAD‐UV detection for the determination of plasma concentrations of carbamazepine and compare its feasibility with those used in routine analysis. The developed HPLC method was fully validated and the applicability of the proposed method was verified through the analysis of plasma samples of patients and later compared with the quantification of the same plasma samples with the CMIA method. The limit of quantification obtained was 0.5 μg/mL. The mean value for recovery was 99.05% and the coefficient of variation (CV) was 5.6%. The precision and accuracy of this method were within the acceptable limits; inter‐ and intraday CV values were <10%. The correlation between the CMIA method and the developed HPLC method was very good (r ≈ 0.999). A Bland–Altman plot showed no significant bias between the results. The HPLC‐DAD method may be an alternative to determine and monitoring the carbamazepine levels in human plasma or serum. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
A simple, sensitive, selective, and reproducible RP‐HPLC method with DAD detection at 240 nm was developed for the determination of six 1,4‐benzodiazepines: bromazepam (BRZ), clonazepam (CLZ), diazepam (DZP), flunitrazepam (FNZ), lorazepam (LRZ), alprazolam (APZ); and two metabolites: α‐hydroxyalprazolam (HALZ) and α‐hydroxytriazolam (HTZL) in human plasma, urine, and saliva, using colchicine as internal standard, after SPE using Nexus Varian cartridges. Separation was performed on a Kromasil C8 (250 mm×5 mm, 5 μm) analytical column with a gradient mobile phase containing methanol, ACN and 0.05 M ammonium acetate. Linearity was held within the range 0.3–20.0 ng/μL, with coefficients of determination (r2) better than 0.997. The within‐ and between‐day assay RSD at 2, 4, 8 ng/μL ranged from 0.03 to 4.7% and 0.5 to 7.0%, respectively in standards, from 1.3 to 7.9% and 3.3 to 7.3%, respectively in plasma, from 2.1 to 6.0% and 2.1 to 7.8%, respectively in urine and at 0.5, 1.0, 2.0 ng/μL ranged from 2.22 to 5.8% and 2.2 to 8.1%, respectively, in saliva. The mean relative recoveries were 96.3–108.6, 96.0–108.2, 94.3–107.1, 97.0–107.0% in within‐day assay and 96.8–107.7, 94.6–107.6, 93.2–105.8, 96.0–108.6 in between‐day assay for standard, plasma, urine, and saliva, respectively. The LOD and LOQ were 0.02–0.47 and 0.07–1.57 ng/μL, respectively.  相似文献   

6.
A simple, rapid, and sensitive method based on dispersive liquid–liquid microextraction combined with HPLC‐UV detection applied for the quantification of chlordiazepoxide in some real samples. The effect of different extraction conditions on the extraction efficiency of the chlordiazepoxide drug was investigated and optimized using central composite design as a conventional efficient tool. Optimum extraction condition values of variables were set as 210 μL chloroform, 1.8 mL methanol, 1.0 min extraction time, 5.0 min centrifugation at 5000 rpm min?1, neutral pH, 7.0% w/v NaCl. The separation was reached in less than 8.0 min using a C18 column using isocratic binary mobile phase (acetonitrile/water (60:40, v/v)) with flow rate of 1.0 mL min?1. The linear response (r2 > 0.998) was achieved in the range of 0.005–10 μg mL?1 with detection limit 0.0005 μg mL?1. The applicability of this method for simultaneous extraction and determination of chlordiazepoxide in four different matrices (water, urine, plasma, and chlordiazepoxide tablet) were investigated using standard addition method. Average recoveries at two spiking levels were over the range of 91.3–102.5% with RSD < 5.0% (n = 3). The obtained results show that dispersive liquid–liquid microextraction combined with HPLC‐UV is a fast and simple method for the determination of chlordiazepoxide in real samples.  相似文献   

7.
Rapid, simple and reliable HPLC/DAD and LC‐ESI‐MS methods for the simultaneous determination of baicalin and forsythin in the traditional Chinese medicinal preparation Shuanghuanglian oral liquid were described and validated. The separation condition for HPLC/DAD was optimized using a BDS hypersil C18 column (Thermo, 2.1 × 150 mm, particle size 5 μm) by gradient elution using methanol‐0.2 % ammonium acetate as the mobile phase. The suitable detection wavelength was set at 277 nm for the quantitative analysis of baicalin and forsythin in this method. Some operational parameters of the ESI interface were optimized, negative m/z 445[M?H]? for baicalin and negative m/z 593[M+CH3COO]? for forsythin, positive m/z 447[M+H]+ for baicalin and positive m/z 552[M+NH 4]+ for forsythin, respectively. These HPLC/DAD and LC‐ESI‐MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). These methods can be used as a complementary method for the commercial quality control of Shuanghuanglian oral liquid and its pharmaceutical preparations.  相似文献   

8.
In this article, an efficient method was developed to screen, isolate and identify the major radical scavengers in the leaves of Olea europaea L. by DPPH‐HPLC‐DAD, HSCCC and NMR. The method of DPPH‐HPLC‐DAD was used to screen the major radical scavengers. It was found that three major constituents (A, B, C) in the extract of the leaves of O. europaea L. possessed potential antioxidant activities. In order to identify the chemical structures of those compounds, the HSCCC method with a two‐phase solvent system composed of petroleum ether–ethyl acetate–water at an optimized volume ratio of 6:600:700 (v/v/v) together with column chromatography was developed to isolate and purify the active compounds. Pure compounds A (225 mg), B (10 mg) and C (12 mg) with purities 92.6, 95.1 and 96.4%, respectively, were obtained from the crude sample (500 mg). Their structures were identified as oleuropein (A), luteolin‐7‐O‐glucoside (B) and verbascoside (C) by 1H‐NMR and 13C‐NMR. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
A new cetyl‐alcohol‐reinforced hollow fiber solid/liquid‐phase microextraction (CA–HF–SLPME) followed by high‐performance liquid chromatography–diode array detection (HPLC–DAD) method was developed for simultaneous determination of ezetimibe and simvastatin in human plasma and urine samples. To prepare the CA–HF–SLPME device, the cetyl‐alcohol was immobilized into the pores of a 2.5 cm hollow fiber micro‐tube and the lumen of the micro‐tube was filled with 1‐octanol with the two ends sealed. Afterwards, the prepared device was introduced into 10 mL of the sample solution containing the analytes with agitation. Under optimized conditions, calibration curves plotted in spiked plasma and urine samples were linear in the ranges of 0.363–25/0.49–25 μg L?1 for ezetimibe/simvastatin and 0.193–25/0.312–25 μg L?1 for ezetimibe/simvastatin in plasma and urine samples, respectively. The limit of detection was 0.109/0.174 μg L?1 for ezetimibe/simvastatin in plasma and 0.058/0.093 μg L?1 for ezetimibe/simvastatin in urine. As a potential application, the proposed method was applied to determine the concentration of selected analytes in patient plasma and urine samples after medication and satisfactory results were achieved. In comparison with reference methods, the CA–HF–SLPME–HPLC–DAD method demonstrates considerable potential in the biopharmaceutical analysis of selected drugs.  相似文献   

10.
This study aims to develop and validate a simple and sensitive liquid chromatography with tandem mass spectrometry (LC–MS/MS) method for investigating the pharmacokinetic characteristics of bavachalcone. Liquid–liquid extraction was used to prepare plasma sample. Chromatographic separation of bavachalcone and IS was achieved using a Venusil ASB C18 (2.1 × 50 mm, 5 μm) column with a mobile phase of methanol (A)–water (B) (70:30, v /v). The detection and quantification of analytes was performed in selected‐reaction monitoring mode using precursor → product ion combinations of m/z 323.1 → 203.2 for bavachalcone, and m/z 373.0 → 179.0 for IS. Linear calibration plots were achieved in the range of 1–1000 ng/mL for bavachalcone (r 2 > 0.99) in rat plasma. The recovery of bavachalcone ranged from 84.1 to 87.0%. The method was precise, accurate and reliable. It was fully validated and successfully applied to pharmacokinetic study of bavachalcone.  相似文献   

11.
For the rational utilization and the quantitative quality control of the Stephania yunnanensis Lo, an HPLC‐DAD method was developed for the quantitative and simultaneous determination of five alkaloids in rat plasma (stepharine, sinomenine, palmatine, isocorydine and tetrahydropalmatine), which were the main active chemical constituents of this plant and belong to four kinds of isoquinoline‐type alkaloids (protoberberine, morphine, aporphine and protaporphine alkaloids). The contents of five alkaloids ranged from 0.09 to 2.32% (w/w). The method validation was tested for the linearity (r2 > 0.9975), precision (intra‐day RSD < 4.8% and inter‐day RSD < 4.9%), extraction recovery (85.49 ± 2.29% to 99.21 ± 1.48%) and stability (98.5 ± 5.3% to 101.2 ± 3.4%). We developed an HPLC‐DAD method to simultaneously measure these alkaloids in rat plasma after oral administration of the extract of this plant to rats. The results supported the hypothesis that isoquinoline alkaloids were the compounds responsible for the main pharmacological activities for anti‐inflammatory and analgesic.  相似文献   

12.
Licarbazepine is the pharmacologically active metabolite of oxcarbazepine, a drug indicated for the treatment of partial seizures and bipolar disorders. Several HPLC methods have been developed thus far but there is lack of control for interferences from antipsychotic drugs. The aim of the present study was to develop a simple, low‐cost and reliable HPLC‐UV method for the determination of licarbazepine in human serum in the presence of co‐administered antiepileptic, antipsychotic and commonly prescribed drugs. Sample preparation consisted of a single protein precipitation step with methanol. Separation lasted ~9 min on a reversed‐phase C18 column using a mobile phase composed of 50 mm sodium‐dihydrogen‐phosphate‐monohydrate/acetonitrile (70:30, v/v) delivered isocratically at 0.9 mL/min and 30°C. Wavelength was 210 nm and calibration curve was linear with r 2 0.998 over the range 0.2–50.0 μg/mL. Coefficient of variation was <5.03% and bias <−4.92%. Recovery ranged from 99.49 to 104.52% and the limit of detection was 0.0182 μg/mL. No interferences from the matrix or from antiepileptic, antipsychotic and commonly prescribed drugs were observed. The method was applied to serum samples of patients under oxcarbazepine treatment and proved to be a useful tool for the therapeutic drug monitoring of licarbazepine during monotherapy or adjunctive treatment of seizures or affective disorders.  相似文献   

13.
Ibrutinib is an oral inhibitor of Bruton tyrosine kinase, which is one of the key drugs used for the treatment of chronic lymphocytic leukemia and mantle cell lymphoma. In this study, we aimed to develop a simple method for determining plasma ibrutinib concentration. The analysis required extraction of a 200 μL plasma sample and precipitation of proteins using solid‐phase extraction. Ibrutinib and nilotinib, which was used as an internal standard, were separated using high‐performance liquid chromatography (HPLC) using a mobile phase of acetonitrile–0.5% monopotassium phosphate (KH2PO4, pH 3.0; 52:48, v/v) on a Capcell Pack C18 MG II (250 × 4.6 mm) monitored at 260 nm, at a flow rate of 1.0 mL/min. The calibration curve was linear at the plasma concentration range of 10–500 ng/mL with a coefficient of determination (r2) of 0.9999. The coefficients of intra‐day and inter‐day validation were 4.0–6.6 and 2.6–7.7%, respectively. The assay accuracy was ?4.4–8.6%, and the recovery was >84%. This HPLC method coupled with ultraviolet (UV) detection for determining ibrutinib plasma concentration has several advantages such as simplicity and applicability to routine therapeutic drug monitoring at hospital laboratories.  相似文献   

14.
Fat‐soluble vitamins play a pivotal role in the progression of atherosclerosis and the development of cardiovascular disease. Therefore, plasma monitoring of their concentrations may be useful in the diagnosis of these disorders as well as in the process of treatment. The study aimed to develop and validate an HPLC–MS/MS method for determination of retinol, α‐tocopherol, 25‐hydroxyvitamin D2 and 25‐hydroxyvitamin D3 in plasma of patients with cardiovascular disease. The analytes were separated on an HPLC Kinetex F5 column via gradient elution with water and methanol, both containing 0.1% (v/v) formic acid. Detection of the analytes was performed on a triple‐quadrupole MS with multiple reaction monitoring via electrospray ionization. The analytes were isolated from plasma samples with liquid–liquid extraction using hexane. Linearity of the analyte calibration curves was confirmed in the ranges 0.02–2 μg/mL for retinol, 0.5–20 μg/mL for α‐tocopherol, 5–100 ng/mL for 25‐hydroxyvitamin D2 and 2–100 ng/mL for 25‐hydroxyvitamin D3. Intra‐ and inter‐assay precision and accuracy of the method were satisfactory. Short‐ and long‐term stabilities of the analytes were determined. The HPLC‐MS/MS method was applied for the determination of the above fat‐soluble vitamin concentrations in patient plasma as potential markers of the cardiovascular disease progression.  相似文献   

15.
A simple, selective and rapid HPLC‐MS/MS method was developed and validated for the determination of caderofloxacin in human plasma. Sparfloxacin was used as the internal standard (IS). After precipitation with methanol and dilution with the mobile phase, the samples were injected into the HPLC‐MS/MS system. The chromatographic separation was performed on a Zorbax XDB Eclipse C18 column (150 × 4.6 mm, 5 µm) with a mobile phase of ammonium acetate buffer (20 mm, pH 3.0)–methanol, 45:55 (v/v). The MS/MS analysis was done in positive mode. The multiple reaction monitoring transitions monitored were m/z 412.3 → 297.1 for caderofloxacin and m/z 393.2 → 292.2 for the IS. The calibration curve was linear over the range of 50.0–8000 ng/mL with an aliquot of 100 μL plasma. The precision of the assay was 2.0–9.4 and 6.6–11.5% for the intra‐ and inter‐run variability, respectively. The intra‐ and inter‐run accuracy (relative error) was 4.4–10.0 and ?1.2–4.0%. The total run time was 3.5 min. The assay was fully validated in accordance with the US Food and Drug Administration guidance. It was successfully applied to a pharmacokinetic study of caderofloxacin in healthy Chinese volunteers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
A rapid and sensitive reversed‐phase high‐performance liquid chromatographic (RP‐HPLC) method was developed to investigate pharmacokinetics of columbianadin, one of the main bioactive constituents in the roots of Angelica pubescens f. biserrata, in rat plasma after intravenous administration to rats at two doses of 10 and 20 mg/kg. The method involves a plasma clean‐up step using liquid–liquid extraction by diethyl ether, followed by RP‐HPLC separation and detection. Separation of columbianadin was performed on an analytical Diamonsil? ODS C18 column, with a mobile phase of MeOH–H2O (85 : 15, v/v) at a flow‐rate of 1.0 mL/min, and UV detection was set at 325 nm. The retention time of columbianadin and scoparone (internal standard) was 6.7 and 3.5 min, respectively. The calibration curve was linear over the range of 0.2–20.0 μg/mL (r2 = 0.9986) in rat plasma. The lower limits of detection and quantification were 0.05 and 0.1 μg/mL, respectively. The extraction recovery from plasma was in the range of 81.61–89.93%. The intra‐ and inter‐day precisions (relative standard deviation) were between 1.01 and 9.33%, with accuracies ranging from 89.76 to 109.22%. The results indicated that the method established was suitable for the determination and pharmacokinetic study of columbianadin in rat plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A new HPLC method was developed and validated for the determination of asymmetric and symmetric dimethylarginines and l ‐arginine in human plasma. After SPE and evaporation of the eluate, the samples were derivatised with an o‐phthaldialdehyde reagent containing 3‐mercaptopropionic acid. The derivatives formed were analysed by isocratic RP‐HPLC with electrochemical detection at +320 mV. The mobile phase consisted of 50 mM phosphate buffer (pH 6.1) containing 10% v/v acetonitrile, the flow rate was 1 mL/min. The retention times of all compounds including monomethylarginine (internal standard) were <24 min. The LODs (S/N 3:1) were 0.012 μM for both dimethylarginines and 0.013 μM for l ‐arginine; the linearity of the method was from 0.1 to 20 μM for both dimethylarginines and from 1 to 200 μM for l ‐arginine. Absolute extraction recoveries measured for all analytes ranged from 85 to 88%.  相似文献   

18.
Dimethylacetamide (DMA) is a solvent used in the preparation of intravenous busulfan, an alkylating agent used in blood or marrow transplantation. DMA may contribute to hepatic toxicity, so it is important to monitor its clearance. The aim of this study was to develop an HPLC‐UV assay for measurement of DMA in human plasma. After precipitation of plasma proteins with acetonitrile followed by dilution (1:4) with water, the extract was injected onto the HPLC and detected at 195 nm. Separation was performed using a Cogent‐HPS 5 μm C18 column (250 × 4.6 mm) preceded by a Brownlee 7 μm RP18, pre‐column (1.5 cm × 3.2 mm). The mobile phase was 25 mm sodium phosphate buffer (pH 3), containing 2.5% (v /v) acetonitrile and 0.0005% (v /v) sodium‐octyl‐sulfonate. Using a flow rate of 1 mL/min, the retention times of DMA and the internal standard (IS), 2‐chloroacetamide, were 9.5 and 3.5 min, respectively. Peak area ratio (DMA:IS) was a linear function of concentration from 1 to 1000 μg/mL. There was excellent intraday precision (<5% for 5–700 μg/mL DMA), accuracy (<3% deviation from the true concentration) and recovery (74–98%). The limits of detection and quantification were 1 and 5 μg/mL, respectively. In eight children who received intravenous busulfan, DMA concentrations ranged from 110 to 438 μg/mL.  相似文献   

19.
γ‐Tocotrienol (γ‐T3) is a member of the vitamin E family. Recently, γ‐T3 has attracted the attention of the scientific community due to its potent anticancer activity and other therapeutic benefits. The objective of this study was to develop and validate a simple and practical reversed‐phase HPLC method with satisfactory sensitivity for the routine quantification of γ‐T3 in rat and human plasma. The separation of γ‐T3 from the plasma components was achieved with a C18 reversed‐phase column with an isocratic elution using a mixture of methanol, ethanol and acetonitrile (85:7.5:7.5, v/v/v) with a UV detection at 295 nm. γ‐T3 was extracted from rat and human plasma by liquid–liquid extraction with an average recovery of 60%. The method proved linear in the range 100–5000 ng/mL. The inter‐day precision ranged from 5.8 to 12.8% and the accuracy ranged from 92.4 to 108.5%, while the intra‐day precision ranged from 0.7 to 7.9% in both rat and human plasma. This data confirm that the developed method has a satisfactory sensitivity, accuracy and precision for the quantification of γ‐T3 in plasma. To assess its applicability the method was successfully applied to the quantitative analysis for pharmacokinetic studies of γ‐T3 in rats administered a 10 mg/kg single oral dose. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive, reliable and simple HPLC method was developed for the determination of lisinopril in human plasma. The method consists of extraction and clean‐up steps based on magnetic solid‐phase extraction and pre‐column derivatization with a fluorescent reagent. The mobile phase consisted of a mixture of methanol–sodium dihydrogen phosphate (pH 3.0; 0.005 m ; 75:25, v/v). The flow rate was set at 0.7 mL/min. Fluorescence detection was performed at 470nm excitation and 530nm emission wavelengths. Total chromatography run time was 5 min. The average extraction recovery of lisinopril and fluvoxamine (internal standard) was ≥82.8%. The limits of detection and quantification were determined as 1 and 3 ng/mL respectively. The method exhibited a linear calibration line over the concentration range of 3–1000 ng/mL with coefficient of determination (r2) of ≥0.98. The within‐run and between‐run precisions were satisfactory with values of CV of 1.8–12.8% (accuracy from 99.2 to 94.7%) and 2.4–13.7% (accuracy from 99.5 to 92.2%), respectively. These developments led to considerable improvement in method sensitivity and reliability. The method was validated according to the US Food and Drug Administration guidelines. Therefore, it can be considered as a suitable method for determination of lisinopril in plasma samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号