首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of this study was a performance comparison of two clean‐up procedures (dilutions versus immunoaffinity columns) in the simultaneous determination of eight mycotoxins (aflatoxin B1, deoxynivalenol, fumonisin B1 & B2, ochratoxin A, toxin T‐2 & HT‐2 and zearalenone) in the animal feed. After extraction the analytes were separated on a Kinetex Biphenyl column with a gradient elution using methanol/0.01 M ammonium acetate as a mobile phase and analyzed with the LC‐MS/MS technique. Both of the procedures were validated by analysis of a series of spiked feed samples (n = 6) at three different concentration levels. Better signal to noise ratios were observed for immunoaffinity clean‐up. The recoveries of analyses were in the range 88–110% for the dilution procedure and 78–120% for the immunoaffinity clean‐up. The dilution procedure was more precise (coefficient of variation of the within‐laboratory reproducibility for it was 7.8–22.4% in comparison to 12–35.5% for the immunoaffinity clean‐up. The results show that both procedures fulfilled the requirements for mycotoxin analysis and can be used successfully in multi‐analyte determination. Although the dilution procedure shows better precision and trueness, the immunoaffinity clean‐up procedure can have advantages in more complex feed samples thanks to lower matrix effect and limits of detections.  相似文献   

2.
Fusarium langsethiae, formally described as a new species over a decade ago, has been identified as the main producer of HT‐2 (HT2) and T‐2 (T2) toxins in Europe in small cereal grains. Mycotoxin contamination caused by this Fusarium species can represent a food safety hazard that deserves further attention. In the present work, the mycotoxin profile in wheat cultures of F. langsethiae is presented with particular reference to the production of major type‐A trichothecenes and their glucosyl derivatives. F. langsethiae isolates, representative of the major Italian wheat cultivation areas, were tested for the production of T2, HT2, diacetoxyscirpenol (DAS) and neosolaniol (NEO), and relevant glucosyl derivatives. Liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) was used for the identification and chemical characterization of these metabolites. F. langsethiae isolates under investigation resulted to be potent producers of T2, HT2 and NEO. Furthermore, a well‐defined set of isolates, all originating from Central Italy, produced also DAS. All isolates were found to be able to produce HT2 glucosyl derivatives, whereas only traces of T2 glucoside were detected in one sample. Furthermore, two mono‐glucosyl derivatives of NEO and one mono‐glucoside derivative of DAS were identified and characterized. The screening for the presence/absence of glucosylated trichothecenes in analyzed fungal extracts revealed a general co‐occurrence of these derivatives with the parent toxin at levels that could be roughly estimated to account up to 37% of the relevant unconjugated toxin. This is the first report of the production of glucosylated trichothecenes by F. langsethiae cultured on small grains. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
The purpose of the present work was to evaluate the synergistic effect of ionization type, sample preparation technique, and bio-fluid on the presence of matrix effect in quantitative liquid chromatography (LC)-MS/MS analysis of illicit drugs by post-column infusion experiments with morphine (10-microg/mL solution). Three bio-fluids (urine, oral fluid, and plasma) were pretreated with four sample preparation procedures [direct injection, dilution, protein precipitation, solid-phase extraction (SPE)] and analyzed by both LC-electrospray ionization (ESI)-MS/MS and LC-atmospheric pressure chemical ionization (APCI)-MS/MS. Our results indicated that both ionization types showed matrix effect, but ESI was more susceptible than APCI. Sample preparation could reduce (clean up) or magnify (pre-concentrate) matrix effect. Residual matrix components were specific to each bio-fluid and interfered at different time points in the chromatogram. We evaluated matrix effect in an early stage of method development and combined optimal ionization type and sample preparation technique for each bio-fluid. Simple dilution of urine was sufficient to allow for the analysis of the analytes of interest by LC-APCI-MS/MS. Acetonitrile protein precipitation provided both sample clean up and concentration for oral fluid analysis, while SPE was necessary for extensive clean up of plasma prior to LC-APCI-MS/MS.  相似文献   

4.
In the present study, we report the application of LC‐MS based on two different LC‐MS systems to mycotoxin analysis. The mycotoxins were extracted with an ACN/water/acetic acid mixture and directly injected into a LC‐MS/MS system without any dilution procedure. First, a sensitive and reliable HPLC‐ESI‐MS/MS method using selected reaction monitoring on a triple quadrupole mass spectrometer (TSQ Quantum Ultra AM) has been developed for determining 32 mycotoxins in crude extracts of wheat and maize. This method was operated both in positive and in negative ionization modes in two separate chromatographic runs. The method was validated by studies of spiked recoveries, linearity, matrix effect, intra‐assay precision and sensitivity. Further, we have developed and evaluated a method based on accurate mass measurements of extracted target ions in full scan mode using micro‐LC‐LTQ‐Orbitrap as a tool for fast quantitative analysis. Both instruments exhibited very high sensitivity and repeatability in positive ionization mode. Coupling of micro‐LC to Orbitrap technology was not applicable to the negatively ionizable compounds. The LC triple quadrupole MS method has proved to be stable in quantitation, as it is with respect to the matrix effects of grain samples.  相似文献   

5.
In this study, we investigated the performance of several commercial sorbents (Sep‐pack® C18, tC18, C8 and tC2, Oasis® HLB, Isolute® ENV+, Strata?‐X and Oasis® MCX) for the determination of opioid peptides by solid‐phase extraction coupled on‐line to capillary electrophoresis (SPE‐CE). First, standard solutions were analyzed in order to achieve the lowest LOD and the best electrophoretic separations using UV detection. The best results were obtained using C18, C8 and tC2 sorbents, which were examined for the analysis of spiked human plasma samples. A double‐step sample clean‐up pretreatment, which consisted of precipitation with acetonitrile and filtration, was needed to prevent saturation of the on‐line SPE microcartridge. The filtration step was critical to obtain optimum analyte recovery and to clean up the sample matrix. A range of centrifugal filters and filtration conditions were tested and the recoveries of the sample pretreatment were evaluated by CE‐ESI‐MS. The LODs attained through SPE‐CE‐UV were approximately ten‐fold better with C18 than with C8 and tC2. The 0.1 μg/mL LODs achieved by C18‐SPE‐CE‐UV were further improved until we could detect 1 ng/mL concentrations of opioid peptides in plasma samples by C18‐SPE‐CE‐ESI‐MS, due to the outstanding selectivity of the MS detection.  相似文献   

6.
A novel design for a rapid clean‐up method was developed for the analysis of pesticide residues in fruit and vegetables followed by LC–ESI‐MS/MS. The acetonitrile‐based sample extraction technique was used to obtain the extracts, and further clean‐up was carried out by applying the streamlined procedure on a multiplug filtration clean‐up column coupled with a syringe. The sorbent used for clean‐up in this research is multiwalled carbon nanotubes, which was mixed with anhydrous magnesium sulfate to remove water from the extracts. This method was validated on 40 representative pesticides and apple, cabbage, and potato sample matrices spiked at two concentration levels of 10 and 100 μg/kg. It exhibited recoveries between 71 and 117% for most pesticides with RSDs < 15%. Matrix‐matched calibrations were performed with the coefficients of determination >0.995 for most studied pesticides between concentration levels of 10–500 μg/L. The LOQs for 40 pesticides ranged from 2 to 50 μg/kg. The developed method was successfully applied to the determination of pesticide residues in market fruit and vegetable samples.  相似文献   

7.
We report a cyclic sample pooling technique devised in two‐dimensional liquid chromatography–electrospray ionization mass spectrometry (LC‐ESI‐MS) shotgun proteomics that renders deeper proteome coverage; we combined low pH reversed‐phase (RP) LC in trifluoroacetic acid in the first dimension, followed by cyclic sample pooling of the eluate and low‐pH RP‐LC in formic acid in the second dimension. The new protocol has a significantly higher resolving power suitable for LC‐ESI‐MS/MS shotgun proteomics. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A sensitive and specific method based on liquid chromatography‐tandem mass spectrometry using electrospray ionization (LC‐ESI‐MS/MS) has been developed for the determination of Schisandrin and Schisandrin B in rat plasma. A 100 μL plasma sample was extracted by methyl tert‐butyl ether after spiking the samples with nimodipine (internal standard) and performed on an XTerra®MS‐C18 column (150 mm × 2.1 mm, 3.5 μm) with the mobile phase of acetonitrile–water–formic acid (80:20:0.2, v/v) at a flow rate of 0.2 mL/min in a run time of 8.5 min. The lower limit of quantification of the method was 40 ng/mL for Schisandrin and 20 ng/mL for Schisandrin B. The method showed reproducibility with intra‐day and inter‐day precision of less than 13.8% RSD, as well as accuracy, with inter‐ and intra‐assay accuracies between 93.5 and 107.2%. Finally, the LC‐ESI‐MS/MS method was successfully applied to study the pharmacokinetics of Schisandrin and Schisandrin B in rats after administration of Wurenchun commercial formulations to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Matrix effects in determination of three β‐receptor agonists including salbutamol (SAL), clenbuterol, and terbutaline in animal‐derived foodstuffs were studied by ultra‐performance LC‐MS/MS with cleanup of immunoaffinity SPE column (IAC). Some animal tissue samples including pig liver, swine muscle, and fish muscle were hydrolyzed by the mixed enzyme solution or HCl solution, and the cleanup efficiencies with SAL IAC, MCX SPE column, and C18‐SCX tandem columns were examined and compared by using spiked experiments. The results showed that the matrix effects in the determination of SAL and terbutaline can be eliminated with SAL IAC cleanup, and the average recoveries of SAL were 77.4~81.5%, 79.0~80.3%, and 85.0~87.2% in pig liver, swine muscle, and fish muscle, respectively. The decision limit (ccα) and detection capability (ccβ) for SAL in pig liver were 0.02 and 0.05 μg/kg, respectively.  相似文献   

10.
A method coupling liquid chromatography with tandem mass spectrometry (LC/MS/MS) was developed for the simultaneous quantitative determination of trichothecenes, nivalenol, deoxynivalenol, deoxynivalenol‐3‐glucoside, fusarenon‐X, 3‐acetyldeoxynivalenol, 15‐acetyldeoxynivalenol, isotrichodermin, calonectrin, 3‐deacetylcalonectrin, 15‐deacetylcalonectrin, 3,15‐diacetylnivalenol, 4,15‐diacetylnivalenol, 3,15‐diacetyldeoxynivalenol, and 3,4,15‐triacetylnivalenol. The analytical parameters of trichothecenes and their derivatives were optimized to enable their highly sensitive detection. Evaluation of clean‐up procedures using Multisep #226 and #227 indicated that Multisep #227 was more suitable for their simultaneous detection in wheat. In performance validation studies using the LC/MS/MS method with Multisep #227 cleanup, good recoveries ranging from 84% to 115% with relative standard deviations from 0.4% to 7.2% were measured. The limits of detection and quantification ranged from 0.03 to 1.4 ng·g?1 and from 0.1 to 4.7 ng·g?1, respectively. The effect of matrices using matrix‐matched calibration was estimated to range from 80% to 117% after Multisep #227 cleanup. Multisep #227 clean‐up procedure with matrix‐free standard calibration achieved accurate quantification without having a considerable effect on matrix compounds. Using the developed method, several trichothecene derivatives and precursors were detected in fungally inoculated wheat samples. The developed LC/MS/MS method is a practical technique that can be used for the quantification of trichothecenes in wheat. This study is the first report of an analytical method used for the simultaneous quantification of major trichothecenes, their derivatives and precursors. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
Increases in the study of protein‐metal complexes, as well as in metal displacement in protein‐metal complexes under native conditions for optimum catalytic properties in drug research and catalyst design, demands a separation/detection technology that can accurately measure metal displacement and stoichiometry in protein‐metal complexes. Both nuclear magnetic resonance (NMR) and X‐ray diffraction techniques have been used for this purpose; however, these techniques lack sensitivity. Electrospray ionization mass spectrometry (ESI‐MS) using direct infusion offers higher sensitivity than the former techniques and provides molecular distribution of various protein‐metal complexes. However, since protein‐metal complexes under native conditions usually are dissolved in salt solutions, their direct ESI‐MS analysis requires off‐line sample clean‐up prior to MS analysis to avoid sample suppression during ESI. Moreover, direct infusion of the salty solution promotes non‐specific salt adduct formation by the protein‐metal complexes under ESI‐MS, which complicates the identification and stoichiometry measurements of the protein‐metal complexes. Because of the high mass of protein‐metal complexes and lack of sufficient resolution by most mass spectrometers to separate non‐specific from specific metal‐protein complexes, accurate protein‐metal stoichiometry measurements require some form of sample clean up prior to ESI‐MS analysis. In this study, we demonstrate that capillary electrophoresis/electrospray ionization in conjunction with a medium‐resolution (~10 000) mass spectrometer is an efficient and fast method for the measurement of the stoichiometry of the protein‐metal complexes under physiological conditions (pH ~7). The metal displacement of Co2+ to Cd2+, two metal ions necessary for activation in the monomeric AHL lactonase produced by B. thuringiensis, has been used as a proof of concept. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
The presence of glucoside derivatives of T‐2 and HT‐2 toxins (type A trichothecene mycotoxins) in naturally contaminated wheat and oats is reported for the first time. The use of advanced high‐resolution mass spectrometry based on Orbitrap technology allowed to obtain molecular structure details by measuring exact masses of main characteristic fragments, with mass accuracy lower than 2.8 ppm (absolute value). A monoglucoside derivative of T‐2 toxin and two monoglucoside derivatives of HT‐2 toxin were identified and characterized. The analysis of their fragmentation patterns provided evidence for glucosylation at C‐3 position for T‐2 toxin and at C‐3 or C‐4 position for HT‐2 toxin. A screening for the presence of these new masked forms of mycotoxins was carried out on a set of naturally contaminated wheat and oats samples. On the basis of peak area ratio between glucoside derivatives and free T‐2 and HT‐2 toxins, the presence of glucoside derivatives was more likely in wheat than in oats samples. The present work confirms the widespread occurrence of trichothecene glucosides in cereal grains naturally contaminated with the relevant unconjugated toxins, thus suggesting the importance of developing suitable analytical methods for their detection. Besides toxicity studies, tracking down these new masked forms of trichothecenes along the food/feed chain would enable to collect information on their relevance in human/animal exposure to mycotoxin risk. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
A highly sensitive and selective method using LC‐ESI‐MS/MS and tandem‐SPE was developed to detect trace amounts of avoparcin (AV) antibiotics in animal tissues and milk. Data acquisition using MS/MS was achieved by applying multiple reaction monitoring of the product ions of [M + 3H]3+ and the major product ions of AV‐α and ‐β at m/z 637 → 86/113/130 and m/z 649 → 86/113/130 in ESI(+) mode. The calculated instrumental LODs were 3 ng/mL. The sample preparation was described that the extraction using 5% TFA and the tandem‐SPE with an ion‐exchange (SAX) and InertSep C18‐A cartridge clean‐up enable us to determine AV in samples. Ion suppression was decreased by concentration rates of each sample solution. These SPE concentration levels could be used to detect quantities of 5 ppb (milk), 10 ppb (beef), and 25 ppb (chicken muscle and liver). The matrix matching calibration graphs obtained for both AV‐α (r >0.996) and ‐β (r >0.998) from animal tissues and milk were linear over the calibration ranges. AV recovery from samples was higher than 73.3% and the RSD was less than 12.0% (n = 5).  相似文献   

14.
A multi‐mycotoxin method was developed for the simultaneous determination of trichothecenes (nivalenol, deoxynivalenol, 3‐acetyldeoxynivalenol, 15‐acetyldeoxynivalenol, neosolaniol, fusarenon‐X, diacetoxyscirpenol, HT‐2 toxin, T‐2 toxin), aflatoxins (aflatoxin‐B1, aflatoxin‐B2, aflatoxin‐G1 and aflatoxin‐G2), Alternaria toxins (alternariol, alternariol methyl ether and altenuene), fumonisins (fumonisin‐B1, fumonisin‐B2 and fumonisin‐B3), ochratoxin A, zearalenone, beauvericin and sterigmatocystin in sweet pepper. Sweet pepper was extracted with ethyl acetate/formic acid (99:1, v/v). After splitting up the extract, two‐thirds of the extract was cleaned up using an aminopropyl column followed by an octadecyl column. The remaining part was cleaned up using a strong anion‐exchange column. After recombination of both cleaned parts of the sample extract, the combined solvents were evaporated and the residue was dissolved in mobile phase; 20 µL was injected into the chromatographic system, so only one run was used to separate and detect the mycotoxins in positive electrospray ionization using selected reaction monitoring. The samples were analyzed with a Micromass Quattro Micro triple quadrupole mass spectrometer (Waters, Milford, MA, USA). The mobile phase consisted of variable mixtures of water and methanol, 1% acetic acid and 5 mM ammonium acetate. The limits of detection of the multi‐mycotoxin method varied from 0.32 µg.kg?1 to 42.48 µg.kg?1. The multi‐mycotoxin liquid chromatography/tandem mass spectrometry (LC/MS/MS) method fulfilled the method performance criteria required by the Commission Regulation (EC) No 401/2006. Sweet peppers inoculated by Fusarium species were analyzed using the developed method. Beauvericin (9–484 µg.kg?1) and fumonisins (fumonisin‐B1 up to 4330 µg.kg?1, fumonisin‐B2 up to 4900 µg.kg?1, and fumonisin‐B3 up to 299 µg.kg?1) were detected. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
Aptamers are single‐stranded oligonucleotides with high affinity and specificity and are widely used in targets separation and enrichment. Here, an aptamer‐affinity column (AAC) was firstly prepared in‐house through a covalent immobilization strategy. Then, ochratoxin A (OTA) in ginger powder was absorbed and enriched using the new aptamer‐based clean‐up technology for the first time, and was further analyzed by ultra high performance liquid chromatography with fluorescence detection. After optimization, the average recoveries for blank samples spiked with OTA at 5, 15, and 45 μg/kg ranged from 85.36 to 96.83%. Furthermore, the AAC exhibited a similar accuracy as an immunoaffinity column to clean up OTA in ginger powder. Above all, it exhibited better reusability, twice that of the immunoaffinity column, had lower toxicity and cost, and took less time. Of 25 contaminated ginger powder samples, OTA contamination levels ranged from 1.51 to 4.31 μg/kg, which were lower than the European Union (EU) regulatory limits. All the positive samples were further confirmed by ultra‐fast LC with MS/MS. In conclusion, the method of clean‐up based on the AAC coupled to ultra‐HPLC with fluorescence detection was rapid, specific, and sensitive for the quantitative analysis of OTA in a complex matrix.  相似文献   

16.
Polyclonal antibodies against microcystin-LR (MC-LR), a cyclic heptapeptide toxin, were generated in rabbits using MC-LR-BSA. An enzyme-linked immunosorbent assay (ELISA) was developed for the characterization of the antibodies and their potential use for analytical purposes. The concentration of MC-LR that inhibits 50% of antibody-antigen binding (IC50) was 0.5 μg L−1 for the indirect ELISA format and 0.9 μg L−1 for the direct ELISA, using MC-LR-horseradish peroxidase conjugate. The limit of detection corresponding to IC80 was found to be 0.06 μg L−1, well below the Word Health Organization level for drinking water of 1 μg L−1. The direct competitive ELISA was applied to water samples and was shown useful for screening purposes. The developed anti-microcystin antibodies were immobilized on solid supports for use in selective solid phase extraction (SPE) systems, prior to liquid chromatography (LC) quantification. An immunoaffinity cartridge (IAC), a Sepharose®-based cartridge incorporating 2 mg of antibodies allowed the selective and quantitative recovery of a mixture of 0.2 μg of MCs showing potential use in sample preparation of real matrices. When applied to water and green algae samples, average recoveries from Sepharose®-based cartridges were in the range of 86-113% for water samples and 85-92% for blue-green algae samples. Selectivity of the IAC clean-up was proven by comparison with non-specific solid phase extraction using octadecylsilica (ODS) sorbent. Results obtained using LC/UV after IAC clean-up agreed well with results obtained using liquid chromatography and mass spectrometry detection (LC/MS and LC/MS/MS) after SPE-C18 clean-up, allowing therefore to validate the resulting technique.  相似文献   

17.
The method employing molecularly imprinted polymers for the extraction and clean up of endocrine‐disrupting compounds (estrogens, bisphenol A, and alkylphenols) from water and sediment is described. The identical extraction/clean‐up and LC‐MS/MS condition were used for the analysis of both types of samples. The method showed high recoveries ranging from 90 to 99% with excellent precision (intrabatch: 3.6–9.3%; interbatch: 5.6–11.4% for water; intrabatch: 4.3–8.5%; interbatch: 6.1–9.6% for sediment). The LOD was in the range of 0.7–1.9 ng/L and 0.3–0.6 ng/g for water and sediment, respectively. Overall extraction on molecularly imprinted polymers substantially enhanced sample clean‐up. The difference in efficiency of clean‐up was particularly pronounced when a large sample volume/weight was extracted and analyzed. Finally, the method was successfully applied for the analysis of 20 water and sediment samples.  相似文献   

18.
Official guidelines originating from a European Union directive regulate requirements for analytical methods used to identify chemical compounds in biological matrices. This study compared different liquid chromatography/electropray ionization mass spectrometry (LC/ESI‐MS) and tandem mass spectrometry (LC/ESI‐MS/MS) procedures for accurate determination of the conjugated ethanol metabolite and alcohol biomarker ethyl glucuronide (EtG) in urine, and the value of combined EtG and ethyl sulfate (EtS) measurement. Analysis was carried out on 482 urines following solid‐phase extraction (SPE) sample cleanup or using direct injection of a diluted sample. SPE combined with LC/MS/MS was demonstrated to be the most selective and sensitive method and was chosen as reference method. The EtG results by different methods showed good correlation (r = 0.96–0.98). When comparing five reporting limits for EtG in the range 0.10–1.00 mg/L, the overall agreement with the reference method (frequency of true positives plus true negatives) was 82–97% for direct‐injection LC/MS/MS, 90–97% for SPE‐LC/MS, 86–98% for direct‐injection LC/MS, and 86–98% for direct‐injection LC/MS analysis of EtG and EtS. Most deviations were attributable to uncertainty in quantitation, when the value was close to a cutoff but the respective results were slightly above and below, or vice versa, the critical limit. However, for direct‐injection LC/MS/MS, despite earning 4 identification points, equally many negative results were due to a product ion ratio outside the ±20% deviation accepted by the guidelines. These results indicate that the likelihood of different analytical methods to provide reliable analytical results depends on the reporting limit applied. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
A simple and practical derivatization procedure for increasing the detectability and enantiomeric separation of chiral carboxylic acids in LC/ESI‐MS/MS has been developed. (S)‐Anabasine (ANA) was used as the derivatization reagent and rapidly reacted with carboxylic acids [3‐hydroxypalmitic acid (3‐OH‐PA), 2‐(β‐carboxyethyl)‐6‐hydroxy‐2,7,8‐trimethylchroman (γ‐CEHC), and etodolac] in the presence of 4‐(4,6‐dimethoxy‐1,3,5‐triazin‐2‐yl)‐4‐methylmorpholium chloride. The resulting ANA‐derivatives were highly responsive in ESI‐MS operating in the positive‐ion mode and gave characteristic product ions during MS/MS, which enabled sensitive detection using selected reaction monitoring; the detection responses of the ANA‐derivatives were increased by 20–160‐fold over those of the intact carboxylic acids and the limits of detection were in the low femtomole range (1.8–11 fmol on the column). The ANA‐derivatization was also effective for the enatiomeric separation of the chiral carboxylic acids; the resolution was 1.92, 1.75, and 2.03 for 3‐OH‐PA, γ‐CHEC, and etodolac, respectively. The derivatization procedure was successfully applied to a biological sample analysis; the derivatization followed by LC/ESI‐MS/MS enabled the separation and detection of trace amounts of 3‐OH‐PA in neonatal dried blood spot and γ‐CEHC in human saliva with a simple pretreatment and small sample volume.  相似文献   

20.
Rapid, simple and reliable HPLC/UV and LC‐ESI‐MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C30 column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC‐ESI‐MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC‐ESI‐MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC‐ESI‐MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC‐ESI‐MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号