 共查询到20条相似文献,搜索用时 671 毫秒
1.
A method for rapid identification and quantification of phthalate plasticizers in beverages was developed. A number of 15 phthalate plasticizers which covered all the phthalates concerned in the US Consumer Product Safety Improvement Act (CPSIA), European Union legislations and Chinese national standards (GB) were analyzed. By a combined solid‐phase micro‐extraction (SPME) and direct analysis in real time mass spectrometry (DART‐MS) approach, phthalates at sub‐ng·mL?1 levels can be qualitatively and quantitatively analyzed in a short time. The use of ultrahigh‐resolving power and the accurate mass measurement capacity naturally provided by Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR‐MS) minimizes the matrix interferences and thus enables the evaluation of phthalates in a complex matrix without extensive sample handlings or preparations. The limits of quantification (LOQs) were estimated to be at 0.3–5.0 ng·mL?1, lower than the Maximum Residue Limit (MRL) regulated by the European Union legislations (2007/19/EC) in foods, beverages, food packaging and toys (0.3–30 ng·mL?1). This rapid and easy‐to‐use SPME‐DART‐FT‐ICR‐MS method provided a relatively high‐throughput and powerful analytical approach for quick testing and screening phthalates in beverages and water samples to ensure food safety.  相似文献   

2.
Matrix‐assisted laser desorption/ionization (MALDI) is a mass spectrometry (MS) ionization technique suitable for a wide variety of sample types including highly complex ones such as natural resinous materials. Coupled with Fourier transform ion cyclotron resonance (FT‐ICR) mass analyser, which provides mass spectra with high resolution and accuracy, the method gives a wealth of information about the composition of the sample. One of the key aspects in MALDI‐MS is the right choice of matrix compound. We have previously demonstrated that 2,5‐dihydroxybenzoic acid is suitable for the positive ion mode analysis of resinous samples. However, 2,5‐dihydroxybenzoic acid was found to be unsuitable for the analysis of these samples in the negative ion mode. The second problem addressed was the limited choice of calibration standards offering a flexible selection of m/z values under m/z 1000. This study presents a modified MALDI‐FT‐ICR‐MS method for the analysis of resinous materials, which incorporates a novel matrix compound, 2‐aminoacridine for the negative ion mode analysis and extends the selection of internal standards with m/z <1000 for both positive (15 different phosphazenium cations) and negative (anions of four fluorine‐rich sulpho‐compounds) ion mode. The novel internal calibration compounds and matrix material were tested for the analysis of various natural resins and real‐life varnish samples taken from cultural heritage objects. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

3.
The conceptual design of the O‐trap Fourier transform ion cyclotron resonance (FT‐ICR) cell addresses the speed of analysis issue in FT‐ICR mass spectrometry. The concept of the O‐trap includes separating the functions of ion excitation and detection between two different FT‐ICR cell compartments. The detection compartment of the O‐trap implements additional internal coaxial electrodes around which ions with excited cyclotron motion revolve. The expected benefits are higher resolving power and the lesser effect of the space charge. In this work we present the first experimental demonstration of the O‐trap cell and its features, including the high ion transfer efficiency between two distinct compartments of an ICR cell after excitation of the coherent cyclotron motion. We demonstrate that utilization of the multiple‐electrode detection in the O‐trap provides mass resolving power enhancement (achieved over a certain time) equal to the order of the frequency multiplication. In an O‐trap installed in a 5 T desk‐top cryogen‐free superconducting magnet, the resolving power of R = 80 000 was achieved for bradykinin [M + 2H]2+ (m/z 531; equivalent to 100 000 when recalculated for m/z 400) in 0.2 s analysis time (transient length), and R = 300 000 at m/z 531 for a 1 s transient. In both cases, detection on the third multiple of the cyclotron frequency was implemented. In terms of the acquisition speed at fixed resolving power, such performance is equivalent to conventional FT‐ICR detection using a 15 T magnet. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
The consumption of design drugs, frequently known as new psychoactive substances (NPS), has increased considerably worldwide, becoming a severe issue for the responsible governmental agencies. These illicit substances can be defined as synthetic compounds produced in clandestine laboratories in order to act as analogs of schedule drugs mimetizing its chemical structure and improving its pharmacological effects while hampering the control and making regulation more complicated. In this way, the development of new methodologies for chemical analysis of NPS drugs is indispensable to determine a novel class of drugs arising from the underground market. Therefore, this work shows the use of high‐resolution mass spectrometry Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR MS) applying different ionization sources such as paper spray ionization (PSI) and electrospray ionization (ESI) in the evaluation of miscellaneous of seized drugs samples as blotter paper (n = 79) and tablet (n = 100). Also, an elucidative analysis was performed by ESI(+)MS/MS experiments, and fragmentation mechanisms were proposed to confirm the chemical structure of compounds identified. Besides, the results of ESI(+) and PSI(+)‐FT‐ICR MS were compared with those of GC–MS, revealing that ESI(+)MS showed greater detection efficiency among the methodologies employed in this study. Moreover, this study stands out as a guide for the chemical analysis of NPS drugs, highlighting the differences between the techniques of ESI(+)‐FT‐ICR MS, PSI(+)‐FT‐ICR MS, and GC–MS.  相似文献   

5.
A combination of methodologies using the extremely high mass accuracy and resolution of 15‐T Fourier transform ion cyclotron resonance (FT‐ICR) mass spectrometry (MS) was introduced for the identification of intact cancer cell phospholipids. Lipids from a malignant glioma cell line were initially analyzed at a resolution of >200 000 and identified by setting the mass tolerance to ±1 mDa using matrix‐assisted laser desorption/ionization (MALDI) 15‐T FT‐ICR MS in positive ion mode. In most cases, a database search of potential lipid candidates using the exact masses of the lipids yielded only one possible chemical composition. Extremely high mass accuracy (<0.1 ppm) was then attained by using previously identified lipids as internal standards. This, combined with an extremely high resolution (>800 000), yielded well‐resolved isotopic fine structures allowing for the identification of lipids by MALDI 15‐T FT‐ICR MS without using tandem mass spectrometric (MS/MS) analysis. Using this method, a total of 38 unique lipids were successfully identified. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
This paper focuses on development of time‐of‐flight (TOF) mass spectrometry in response to the invention of matrix‐assisted laser desorption/ionization (MALDI). Before this breakthrough ionization technique for nonvolatile molecules, TOF was generally considered as a useful tool for exotic studies of ion properties but was not widely applied to analytical problems. Improved TOF instruments and software that allow the full potential power of MALDI to be applied to difficult biological applications are described. A theoretical approach to the design and optimization of MALDI‐TOF instruments for particular applications is presented. Experimental data are provided that are in excellent agreement with theoretical predictions of resolving power and mass accuracy. Data on sensitivity and dynamic range using kilohertz laser rates are also summarized. These results indicate that combinations of high‐performance MALDI‐TOF and TOF‐TOF with off‐line high‐capacity separations may ultimately provide throughput and dynamic range several orders of magnitude greater than those currently available with electrospray LC‐MS and MS‐MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Metabolomic fingerprinting of bodily fluids can reveal the underlying causes of metabolic disorders associated with many diseases, and has thus been recognized as a potential tool for disease diagnosis and prognosis following therapy. Here we report a rapid approach in which direct analysis in real time (DART) coupled with time-of-flight (TOF) mass spectrometry (MS) and hybrid quadrupole TOF (Q-TOF) MS is used as a means for metabolomic fingerprinting of human serum. In this approach, serum samples are first treated to precipitate proteins, and the volatility of the remaining metabolites increased by derivatization, followed by DART MS analysis. Maximum DART MS performance was obtained by optimizing instrumental parameters such as ionizing gas temperature and flow rate for the analysis of identical aliquots of a healthy human serum samples. These variables were observed to have a significant effect on the overall mass range of the metabolites detected as well as the signal-to-noise ratios in DART mass spectra. Each DART run requires only 1.2 min, during which more than 1500 different spectral features are observed in a time-dependent fashion. A repeatability of 4.1% to 4.5% was obtained for the total ion signal using a manual sampling arm. With the appealing features of high-throughput, lack of memory effects, and simplicity, DART MS has shown potential to become an invaluable tool for metabolomic fingerprinting.  相似文献   

8.
Ultra‐high‐resolution mass spectrometry, in the absence of chromatography, is finding its place for direct analyses of highly complex mixtures, such as those encountered during untargeted metabolomics screening. Advances, however, have been tempered by difficulties such as uneven signal suppression experienced during electrospray ionization. Moreover, ultra‐high‐resolution mass spectrometers that use Orbitrap and ICR analyzers both suffer from limited ion trapping capacities, owing principally to space‐charge effects. This study has evaluated and contrasted the above two types of Fourier transform mass spectrometers for their abilities to detect and identify by accurate mass measurement, small molecule metabolites present in complex mixtures. For these direct introduction studies, the Orbitrap Fusion showed a major advantage in terms of speed of analysis, enabling detection of 218 of 440 molecules (<2 ppm error, 500 000 resolution at m/z 200) present in a complex mixture in 5 min. This approach is the most viable for high‐throughput workflows, such as those used in investigations involving very large cohorts of metabolomics samples. From the same mixture, 183 unique molecules were observed by FT‐ICR in the broadband mode, but this number was raised to 235 when “selected ion monitoring‐stitching” (SIM‐stitching) was employed (<0.1 ppm error, 7 T magnet with dynamic harmonization cell, 1.8 million resolution at m/z 200, both cases). SIM‐stitching FT‐ICR thus offered the most complete detection, which may be of paramount importance in situations where it is essential to obtain the most complete metabolic profile possible. This added completeness, however, came at the cost of a more lengthy analysis time (120 min including manual treatment). Compared to the data presented here, future automation of processing, plus the use of absorption mode detection, segmented ion detection (stepwise detection of smaller width m/z sections), and higher magnetic field strengths, can substantially reduce FT‐ICR acquisition times.  相似文献   

9.
Soft‐ionization methods are currently at the forefront of developing novel methods for analysing degraded archaeological organic residues. Here, we present little‐used soft ionization method of matrix assisted laser desorption/ionization‐Fourier transform‐ion cyclotron resonance‐mass spectrometry (MALDI‐FT‐ICR‐MS) for the identification of archaeological lipid residues. It is a high‐resolution and sensitive method with low limits of detection capable of identifying lipid compounds in small concentrations, thus providing a highly potential new technique for the analysis of degraded lipid components. A thorough methodology development for analysing cooked and degraded food remains from ceramic vessels was carried out, and the most efficient sample preparation protocol is described. The identified components, also controlled by independent parallel analysis by gas chromatography‐mass spectrometry (GC‐MS) and gas chromatography‐combustion‐isotope ratio mass spectrometry (GC‐C‐IRMS), demonstrate its capability of identifying very different food residues including dairy, adipose fats as well as lipids of aquatic origin. The results obtained from experimentally cooked and original archaeological samples prove the suitability of MALDI‐FT‐ICR‐MS for analysing archaeological organic residues. Sample preparation protocol and identification of compounds provide future reference for analysing various aged and degraded lipid residues in different organic and mineral matrices.  相似文献   

10.
An introduction to quadrupole-time-of-flight mass spectrometry   总被引:11,自引:0,他引:11  
A brief introduction is presented to the basic principles and application of a quadrupole-time-of-flight (TOF) tandem mass spectrometer. The main features of reflecting TOF instruments with orthogonal injection of ions are discussed. Their operation and performance are compared with those of triple quadrupoles with electrospray ionization and matrix-assisted laser desorption/ionization (MALDI) TOF mass spectrometers. Examples and recommendations are provided for all major operational modes: mass spectrometry (MS) and tandem MS (MS/MS), precursor ion scans and studies of non-covalent complexes. Basic algorithms for liquid chromatography/MS/MS automation are discussed and illustrated by two applications.  相似文献   

11.
In this work, an approach using high‐performance liquid chromatography coupled with diode‐array detection and Fourier‐transform ion cyclotron resonance mass spectrometer (HPLC‐FT‐ICR MS) for the identification and profiling of chemical constituents in Rhodiola crenulata was developed for the first time. The chromatographic separation was achieved on an Inertsil ODS‐3 column (150 mm × 4.6 mm,3 µm) using a gradient elution program, and the detection was performed on a Bruker Solarix 7.0 T mass spectrometer equipped with electrospray ionization source in both positive and negative modes. Under the optimized conditions, a total of 48 chemical compounds, including 26 alcohols and their glycosides, 12 flavonoids and their glycosides, 5 flavanols and gallic acid derivatives, 4 organic acids and 1 cyanogenic glycoside were identified or tentatively characterized. The results indicated that the developed HPLC‐FT‐ICR MS method with ultra‐high sensitivity and resolution is suitable for identifying and characterizing the chemical constituents in R. crenulata. And it provides a helpful chemical basis for further research on R. crenulata. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
This work discusses the correlation between the mass resolving power of matrix‐assisted laser desorption/ionization time‐of‐flight mass analyzers and extraction condition with an uneven sample morphology. Previous theoretical calculations show that the optimum extraction condition for flat samples involves an ideal ion source design and extraction delay. A general expression of spectral feature takes into account ion initial velocity, and extraction delay is derived in the current study. The new expression extends the comprehensive calculation to uneven sample surfaces and above 90% Maxell‐Boltzmann initial velocity distribution of ions to account for imperfect ionization condition. Calculation shows that the impact of uneven sample surface or initial spatial spread of ions is negligible when the extraction delay is away from the ideal value. When the extraction delay approaches the optimum value, the flight‐time topology shows a characteristic curve shape, and the time‐domain mass spectral feature broadens with an increase in initial spatial spread of ions. For protonated 2,5‐dihydroxybenzoic acid, the mass resolving power obtained from a sample of 3‐μm surface roughness is approximately 3.3 times lower than that of flat samples. For ions of m/z 3000 coexpanded with 2,5‐dihydroxybenzoic acid, the mass resolving power in the 3‐μm surface roughness case only reduces roughly 7%. Comprehensive calculations also show that the mass resolving power of lighter ions is more sensitive to the accuracy of the extraction delay than heavier ions.  相似文献   

13.
Metabolism studies play an important role at various stages of drug discovery and development. Liquid chromatography combined with mass spectrometry (LC/MS) has become a most powerful and widely used analytical tool for identifying drug metabolites. The suitability of different types of mass spectrometers for metabolite profiling differs widely, and therefore, the data quality and reliability of the results also depend on which instrumentation is used. As one of the latest LC/MS instrumentation designs, hybrid ion trap/time‐of‐flight MS coupled with LC (LC‐IT‐TOF‐MS) has successfully integrated ease of operation, compatibility with LC flow rates and data‐dependent MSn with high mass accuracy and mass resolving power. The MSn and accurate mass capabilities are routinely utilized to rapidly confirm the identification of expected metabolites or to elucidate the structures of uncommon or unexpected metabolites. These features make the LC‐IT‐TOF‐MS a very powerful analytical tool for metabolite identification. This paper begins with a brief introduction to some basic principles and main properties of a hybrid IT‐TOF instrument. Then, a general workflow for metabolite profiling using LC‐IT‐TOF‐MS, starting from sample collection and preparation to final identification of the metabolite structures, is discussed in detail. The data extraction and mining techniques to find and confirm metabolites are discussed and illustrated with some examples. This paper is directed to readers with no prior experience with LC‐IT‐TOF‐MS and will provide a broad understanding of the development and utility of this instrument for drug metabolism studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Mass spectrometers that use different types of analyzers for the first and second stages of mass analysis in tandem mass spectrometry (MS/MS) experiments are often referred to as "hybrid" mass spectrometers. The general goal in the design of a hybrid instrument is to combine different performance characteristics offered by various types of analyzers into one mass spectrometer. These performance characteristics may include mass resolving power, the ion kinetic energy for collision-induced dissociation, and speed of analysis. This paper provides a review of the development of hybrid instruments over the last 30 years for analytical applications.  相似文献   

15.
Direct analysis in real time (DART) is a plasma-based ambient ionization technique that enables rapid ionization of small molecules with high sample throughput. In this work, DART was coupled to an orthogonal (oa) time-of-flight (TOF) mass spectrometer and the system was optimized for analyzing a vital hormonal regulator in insects, juvenile hormone (JH) III and its terpene precursors, namely, farnesol, farnesoic acid, and methyl farnesoate. Optimization experiments were planned using design of experiments (DOE) full factorial models to identify the most significant DART variables contributing to JH III analysis sensitivity by DART-TOF mass spectrometry (MS). The optimized DART-TOF MS method had femtomole to sub-picomole detection limits for terpene standards, along with mass accuracies below 5 ppm. Finally, the possibility of distinguishing between two farnesol isomers by in-source-collision-induced dissociation (CID) in the first differentially pumped region of the oaTOF mass spectrometer was investigated. DART-MS enabled high-throughput, sensitive analysis with acquisition times ranging from 30 s to a minute. To the best of our knowledge, this is the first report on the application of DART-MS to the detection and identification of volatile or semi-volatile insect terpenoids, and on the use of DOE approaches to optimize DART-MS analytical procedures.  相似文献   

16.
17.
We describe a rapid in situ method for detecting agrochemicals on the surface or in the tissue of fruit using a portable mass spectrometer equipped with an ambient ionization source. Two such ionization methods, low temperature plasma (LTP) and paper spray (PS), were employed in experiments performed at a local grocery store. LTP was used to detect diphenylamine (DPA) directly from the skin of apples in the store and those treated after harvest with DPA were recognized by MS and MS/MS. These data therefore allowed ready distinction between organic and non-organic apples. DPA was also found within the internal tissue of purchased apples and its distribution was mapped using LTP. Similarly, thiabendazole residues were detected on the skin of treated oranges in a grocery store experiment in which paper spray was performed by wiping the orange surface with a moist commercial lens wipe and then applying a high voltage to ionize the chemicals directly from the wipe. The handheld mass spectrometer used in these measurements is capable of performing several stages of tandem mass spectrometry (up to MS(5)); the compounds on the fruit were identified by their MS/MS fragmentation patterns. Protonated DPA (m/z 170) produced a characteristic MS(2) fragment ion at m/z 92, while thiabendazole was identified by MS(3) using precursor to fragment ion transitions m/z 202 →m/z 175 →m/z 131. These particular examples exemplify the power of in situ analysis of complex samples using ambient ionization and handheld mass spectrometers.  相似文献   

18.
Direct analysis in real time mass spectrometry (DART‐MS) was used to monitor the release kinetics of a taste‐refreshing compound from chewing gums into the saliva of subjects. A new DART‐MS sample probe was designed which was about four times more sensitive than the current benchmark probe. This decreased the impact of the dilution of the saliva samples that was required to minimize ion suppression effects and make quantitative analyses without an internal standard possible. The new probe was also about three times more reproducible, which allowed quantitative measurements to be conducted manually without requiring the enhanced precision provided by an automatic sample positioner. The accuracy of analyses performed by DART‐MS was verified by comparing the results obtained from saliva samples analyzed both by DART‐MS and by a more classical liquid chromatography/mass spectrometry (LC/MS) method. This investigation showed good agreement between the two techniques. DART‐MS could then be used to objectively demonstrate the efficiency of a granular carbohydrate‐based delivery system to boost for a few minutes the release of a lipophilic flavor raw material with a high octanol/water partition coefficient, cyclohexanecarboxamide, N‐ethyl‐5‐methyl‐2‐(1‐methylethyl) (WS‐3), from chewing gum into saliva. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
The analysis of crude oil samples remains a tough challenge due to the complexity of the matrix and the broad range of physical and chemical properties of the various individual compounds present. In this work, atmospheric pressure laser ionization (APLI) is utilized as a complementary tool to other ionization techniques for crude oil analysis. Mass spectra obtained with electrospray ionization (ESI) and atmospheric pressure photoionization (APPI) are compared. APLI is primarily sensitive towards non‐polar aromatic hydrocarbons, which are generally present in high amounts especially in heavy crude oil samples. The ionization mechanisms of APLI vs. APPI are further investigated. The results indicate the advantages of APLI over established methods like ESI and APPI. The application of APLI in combination with Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR MS) is thus demonstrated to be a powerful tool for the analysis of aromatic species in complex crude oil fractions. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
尿液作为一种易于获取的体内毒品检材,在吸毒人员快速筛查中被广泛应用。针对传统快速筛查技术存在假阳性率高、定量能力不足以及实验室质谱技术在快速检测中存在前处理复杂、检测耗时长、使用环境苛刻等问题,该文提出了一种基于敞开式直接电离质谱技术的生物样本快速检测方法。该研究采用探针式电喷雾离子源与便携式质谱仪联用快速检测平台,优化了喷雾电压和质谱入口毛细管温度,开发了高效快速的前处理技术。基于该平台和前处理技术,5种常规毒品(甲基苯丙胺、氯胺酮、可卡因、O^(6)-单乙酰吗啡和3,4-亚甲双氧甲基苯丙胺)的尿液加标溶液的检出限为0.5~30 ng/mL,且其中4种毒品定量检测的线性相关系数大于0.99。除此之外,5种常规毒品在3个不同水平下的加标回收率为56.1%~103.7%,多次检测结果的相对标准偏差为9.0%~27.8%,说明联用检测平台与前处理方法结合可以达到良好的准确度。为了进一步检验该联用仪器的实战能力,测试了某社区戒毒康复中心40份阳性和110份阴性实际尿液样本,总体检测的准确率接近99%,且通过一次进样在20 s内可同时检测多种毒品。该研究成果有利于推动快速检测技术的发展,促进敞开式直接电离质谱仪技术的推广应用,提升一线执法服务水平。  相似文献   