首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
A Sn2+ ion-selective electrode which was prepared with a polymeric membrane based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0]hex-2-ene (NDDBH) as a ionophore. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, the amount of additive and concentration of internal solution on the potential response of Sn2+ sensor were investigated. The electrode exhibited a Nernstian slope of 28.8 ± 1.1 mV/decade of Sn2+ over a concentration range of 1.0 × 10−5 to 1.0 × 10−1 M of Sn2+ in an acidic solution (pH 1). The limit of detection was 4.0 × 10−6 M. The results show that this electrode can be used in ethanol media until 20% (v/v) concentration without interference. It can be used for more than 6 weeks without any considerable divergence in the potentials. The proposed membrane electrode revealed very good selectivity for Sn(II) ions over a wide variety of other cations and could be used in acidic media. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The stability constant (log Ks) of the Sn(II)-ionophore complex was determined at 25 °C by potentiometric titration in mixed aqueous solution. It was used as indicator electrode in potentiometric determination of Sn(II) ion in real samples.  相似文献   

2.
A PVC-based sensor for La3+ ions based on N-[hexahydrocyclopentapyrol-2((1H)yl)amino]carbonyl]-4-methyl benzene sulfonamide (gliclazide) as a novel carrier was prepared. The electrode exhibits a Nernstian response for La3+ over a wide concentration range (1.0×10−1-1.0×10−6 M) with a slope of 20.1 mV per decade. The limit of detection is 8.0×10−7 M. The sensor has a very short response time (<15 s) and a useful working pH range of 4.0-8.0. The proposed membrane sensor shows excellent discriminating ability towards La3+ ions with regard to several alkali, alkaline earth, transition and heavy metal ions. The electrode was successfully applied for determination of La3+ in binary mixtures.  相似文献   

3.
A highly selective membrane electrode based on nickel(II)-1,4,8,11,15,18,22,25-octabutoxyphthalocyanine (NOBP) is presented. The proposed electrode shows very good selectivity for thiocyanate ions over a wide variety of common inorganic and organic anions. The sensor displays a near Nernstian slope of −58.7 ± 0.6 mV per decade. The working concentration range of the electrode is 1.0 × 10−6 to −1.0 × 10−1 M with a detection limit of 5.7 × 10−7 M (33.06 ng/mL). The response time of the sensor in whole concentration ranges is very short (<10 s). The response of the sensor is independent on the pH range of 4.3-9.8. The best performance was obtained with a membrane composition of 30% PVC, 65% dibutyl phthalate, 3% NOBP and 2% hexadecyltrimethylammonium bromide. It was successfully applied to direct determination of thiocyanate in biological samples, and as an indicator electrode for titration of thiocyanate ions with AgNO3 solution.  相似文献   

4.
In this work, a novel La(III) membrane sensor based on 8-amino-N-(2-hydroxybenzylidene)naphthylamine (AIP) is presented. This electrode reveals good selectivity for La3+ over a wide variety of lanthanides metal ions. Theoretical calculations and conductance study of AIP to lanthanum and some other metal ions were carried out and confirmed selectivity toward La(III) ions. The electrode comprises 7% AIP, 30% PVC, 61% NPOE and 2% KTpClPB. The sensor displays a linear dynamic range between 1.0 × 10−7 and 1.0 × 10−1 M, with a nice Nernstian slope of 20.3 ± 0.3 mV per decade and a detection limit of 8.0 × 10−8 M. The potentiometric response is independent of pH in the range of 4.0-9.0. The proposed sensor posses the advantage of short response time, and especially, very good selectivity towards a large number of cations, such as Sm(III), Ce(III, Pr(III), Yb(III) and Hg(II), low detection limit and wide linear dynamic range in comparison with former ones. The electrode can be used for at least seven weeks without any considerable divergence in the potentials. It was used as an indicator electrode in the potentiometric titration of La(III) ions with EDTA. The sensor was applied to the determination of La(III) ions concentration in binary mixtures. It was also applied for the determination of fluoride ions in mouth wash preparations.  相似文献   

5.
A novel selective membrane electrode for determination of ultra-trace amount of lead was prepared. The PVC membrane containing N,N′-dimethylcyanodiaza-18-cown-6 (DMCDA18C6) directly coated on a graphite electrode, exhibits a Nernstian response for Pb2+ ions over a very wide concentration range (from 1.0×10−2 to 1.0×10−7 M) with a limit of detection of 7.0×10−8 M (∼14.5 ppb). It has a fast response time of ∼10 s and can be used for at least 2 months without any major deviation in potential. The electrode revealed very good selectivity with respect to all common alkali, alkaline earth, transition and heavy metal ions. The proposed sensor was used as an indicator electrode in potentiometric titration of lead ions and in determination of lead in edible oil, human hair and water samples. The proposed sensor was found to be superior to the best Pb2+-selective electrodes reported in terms of detection limit and selectivity coefficient.  相似文献   

6.
The feasibility of a newly synthesized Rh(III) complex, Rh[(trpy)(bpy)Cl](PF6)2, as a novel ionophore for the preparation of anion-selective polymeric membrane electrodes was tested. The ionophore exhibited anti-Hofmeister behavior with enhanced potentiometric selectivity toward thiocyanate ion compared to other anions. The influence of some experimental parameters such as membrane composition, nature and amount of plasticizer and additive and concentration of internal solution on the potential response of the SCN sensor were investigated. The electrode exhibits a Nernstian response for SCN over a wide concentration range (1.0 × 10−5 to 1.0 × 10−1 M) with a slope −58.7 ± 0.5 mV per decade and a detection limit of 4.0 × 10−6 M (0.23 ppm). It could be used in a pH range of 3.0-8.0 and has a fast response time of about 15 s. The proposed sensor was used for the determination of thiocyanate ions in real samples such as urine and saliva of smokers and nonsmokers and, as an indicator electrode, in potentiometric titrations of SCN ion.  相似文献   

7.
A PVC membrane electrode for copper ion based on 1,3-dithiane,2-(4-methoxy phenyl) as ionophore and o-nitrophenyl octyl ether as a plasticizer is demonstrated. The electrode exhibits a Nernstian slope of 29.5±1 mV per decade in a linear range of 3.0×10−6 to 5.0×10−2 M for Cu2+ ion. The detection limit of this electrode is 1.0×10−6 mol/l. This sensor has a very short response time of about 5 s and could be used in a pH range of 4.0-7.0. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully applied as an indicator electrode for the potentiometric titration of copper ion with EDTA and for the direct determination of copper in river water.  相似文献   

8.
A metal ion indicator, Alizarin Red S, was tested for its potential use in uranium selective optode membrane. The water-soluble indicator was lipophilized in the form of an ion pair with tetraoctylammonium bromide, and subsequently immobilized on a triacetyl cellulose membrane. The membrane responds to uranium ions, giving a color change from yellow to violet in acetate buffer pH 5. This optode has a linear range of (1.70-18.7) × 10−5 M of UO22+ ions with a limit of detection of 5 × 10−6 M. The response time of optode was within 6 min depending on the concentration of UO22+ ions. The sensor can readily be regenerated with hydrochloric acid solution (0.01 M). The optode is fully reversible.  相似文献   

9.
A new PVC membrane electrode for manganese(II) ion based on a recently synthesized Schiff base of 5-[(4-nitrophenylazo)-N-hexylamine]salicylaldimine is reported. The electrode exhibits a Nernstian response for Mn2+ ions over a wide concentration range (4.0 × 10−7 to 1.8 × 10−2 mol L−1) with a slope of 30.1 (±1.0). The limit of detection is 1.0 × 10−7 mol L−1. The electrode has a fast response time (∼10 s), a satisfactory reproducibility and relatively long life time. The proposed sensor revealed good selectivities over a wide variety of other cations include hard and soft metals. This electrode could be used in a pH range of 4.5-7.5. It was used as an indicator electrode in potentiometric titration of manganese(II) ions with EDTA solution.  相似文献   

10.
Solution studies on the binding properties of N-2,4-dimethylphenyl-N′-ethylformamidine (amitraz) toward nine lanthanide ions including lanthanum, cerium, neodium, samarium, europium, gadolinium, terbium, dysprosium, ytterbium and some other transition and heavy metal ions such as copper, lead, cobalt, nickel ions, showed a selective 1:1 complexation between amitraz and lanthanum ions. Consequently, amitraz was applied as an ion carrier in construction of a novel poly(vinyl chloride) membrane sensor for La(III). The sensor has a linear dynamic range of 1.0 × 10−1 to 1.0 × 10−7 M with a Nernstian slope of 19.8 ± 0.2 mV per decade and a detection limit of 8.0 × 10−8 M. The proposed sensor displays a fast response time (<8 s), and can be used for at least 2 months without any considerable divergences in the potentials. The La(III) membrane sensor revealed comparatively good selectivity with respect to most of cations including alkaline, alkaline earth, and some transition and heavy metal ions. It could be used in a pH range of 3.0-9.0. The proposed membrane electrode was used as an indicator electrode in the potentiometric titration of La(III) ions with an EDTA solution, and also in the determination of fluoride concentration in some mouth wash preparations.  相似文献   

11.
A novel optical sensor has been proposed for sensitive determination of thorium (IV) ion in aqueous solutions. The thorium sensing membrane was prepared by incorporating 4-(p-nitrophenyl azo)-pyrocatechol (NAP) as ionophore in the plasticized PVC membrane containing tributyl phosphate (TBP) as plasticizer. The membrane responds to thorium ion by changing color reversibly from yellow to red-brown in glycine buffer solution at pH 3.5. The proposed sensor displays a linear range of 8.66 × 10−6-2.00 × 10−4 M with a limit of detection of 6 × 10−6 M. The response time of the optode was about 8.8-12.5 min, depending on the concentration of Th (IV) ions. The selectivity of optode to Th (IV) ions in glycine buffer is good. The sensor can readily be regenerated by exposure to a solution mixture of sodium fluoride and 5-sulfosalicylic acid (dihydrate) (0.01 M each). The optode is fully reversible. The proposed optode was applied to the determination of thorium (IV) in environmental water samples.  相似文献   

12.
The suitability of a xanthone derivative, 1-hydroxy-3-methyl-9H-xanthen-9-one (HMX) as a neutral ionophore for the preparation of a polyvinylchloride (PVC) membrane electrode for aluminum(III) ions was investigated. The prepared electrode exhibits a Nernstian response for Al3+ ions over a wide concentration range (1.0 × 10−6 to 1.6 × 10−1 M) with a limit of detection 6.0 × 10−7 M. It has a relatively fast response time and can be used for at least three months without any considerable divergence in potentials. The proposed membrane electrode revealed very good selectivity for Al3+ ions over a wide variety of other cations and could be used at a working pH range of 3.0-8.5. It was used as an indicator electrode in potentiometric titration of aluminum ions with EDTA and in the determination of Al3+ in different real samples.  相似文献   

13.
A novel PVC-based membrane sensor based on vanadyl salophen (VNSP) for determination of trace amounts of monohydrogenphosphate (MHP) ions is introduced. The electrode revealed Nernstian response towards monohydrogenphosphate over the wide concentration range from 1.0×10−1 to 1.0×10−6 M at the pH of 8.2. The effect of solvent mediator, cationic additives and amount of ion-carrier on the behavior of the sensor was investigated. The sensor shows a short response time (<20 s) in the whole concentration ranges. The selectivity of the electrode is very high, and it can be used for detection of trace amounts of monohydrogenphosphate in the presence of large amounts of other anions. The detection limit of the electrode was 5.0×10−7 M (48 ng/ml) and it could be used for 14 weeks without any measurable changes in the slope. The potentiometric selectivity coefficients data revealed negligible interference from 16 common anions. It was successfully applied for the direct determination of monohydrogenphosphate in fertilizer samples and, as an indicator electrode, in potentiometric titration of HPO42− ion with barium nitrate.  相似文献   

14.
Cu2+-mediated salbutamol-imprinted polymer nanoparticles, synthesized by precipitation polymerization, were mixed with graphite powder and n-eicosane in order to fabricate a modified carbon paste electrode. This electrode was then applied for indirect differential pulse voltammetry determination of salbutamol. In the presence of Cu2+ ions, the formed Cu2+–salbutamol complex was adsorbed in to the pre-designed cavities of the MIP particles, situated on the electrode surface. Since the electrochemical signal of salbutamol was intrinsically small, the oxidation peak of the participant Cu2+, after reduction step, was recorded and used as an indication of salbutamol amount, adsorbed in the electrode. Different variables influencing the sensor performance were studied and the best conditions were chosen for the determination purpose. Correlation between the sensor response to salbutamol and its concentration was linear in the range of 1.0 × 10−9–5.5 × 10−8 M. Detection limit was calculated equal to 6.0 × 10−10 M (S/N). Five replicated determination of salbutamol (1 × 10−8 M) resulted in standard error of 3.28%, meaning a satisfactory precision of the determination method. The prepared sensor was applied for real sample analysis. In order to minimize the interference effect, the synthesized polymer was successfully used as a solid phase sorbent for salbutamol extraction, before analysis of real samples by the developed sensor.  相似文献   

15.
The potentiometric behavior of coated wire electrodes based on dodecylbenzenesulfonate-doped polypyrrole (PPy-DBS) and hyamine as ion exchanger was investigated. The PPy-DBS was prepared electrochemically by anodic polymerization of pyrrole in the presence of DBS ions in aqueous solution and used as ionophore for construction of the sensor. Two types of coated wire electrodes made of PVC-PPy-DBS and PVC-Hyamine-DBS, plasticized with ortho-nitrophenyloctylether (o-NPOE) showed the Nernstian behavior (with respective calibration slopes of about 58 and 60 mV per decade) over the DBS concentration range of 3.0×10−6 to 1.1×10−3 M and 5.0×10−6 to 1.3×10−3 M, respectively. The influence of membrane composition, type of plasticizer, and pH of test solution on the potentiometric responses of the two electrodes was investigated. The potentiometric response was independent of the pH of test solution in the range 3-10. The response time of electrodes was fast (10 s for both types of electrode), and they can be used for at least 3 months without any significant change in potential. The proposed electrodes revealed very good selectivity for DBS ion over diverse inorganic and organic anions. The potentiometric selectivity coefficients for the PPy-DBS based electrode revealed a significant improvement as compared to the electrode made by conventional Hyamine-DBS (Hya-DBS) anion exchanger. The proposed electrode was used for determination of DBS ion in some commercial detergents. The results of the potentiometric determinations were in satisfactory agreement with those obtained by a standard method (two-phase titration).  相似文献   

16.
A novel potentiometric zirconium - PVC matrix membrane sensor incorporating bis(diphenylphosphino) ferrocene as an electroactive material and tris(2-ethylhexyl)phosphate as solvent mediator is described. In mixed acetate buffer solution of pH 4.8, the sensor displays a rapid and linear response for zirconium ion over the concentration range 1.0 × 10−1 to 1.0 × 10−7 mol L−1 with a good slope of 59.7 ± 0.3 mV per decade and detection limit 1.8 × 10−8 mol L−1. The best performance was obtained with membrane composition 33% PVC, 65% TEHP, 1% NaTPB and 1% ionophore. The proposed electrode revealed excellent selectivity for zirconium ion over a wide variety of alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.15-7.8. The electrode was applied for at least 1 month without any considerable divergence in the potential responses. The practical utility of the electrode has been demonstrated by its use as an indicator electrode in the potentiometric titration of zirconium ions with sodium fluoride and in determination of zirconium ion in some alloy, tape and waste water samples.  相似文献   

17.
New polymeric membrane (PME) and coated graphite (CGE) samarium(III)-selective electrodes were prepared based on isopropyl 2-[(isopropoxycarbothioyl) disulfanyl]ethanethioate as a suitable neutral ionophore. The electrodes exhibit Nernstian slopes for Sm3+ ions over wide concentration ranges (1.0×10−5 to 1.0×10−1 M for PME and 1.0×10−6 to 1.0×10−1 M for CGE). The PME and CGE have limits of detection of 3.1×10−6 and 5.0×10−7 M, respectively, and response times of about 20 s. The potentiometric responses are independent of the pH of the test solution in the pH range 4.0-7.0. The proposed electrodes revealed good selectivities over a wide variety of other cations including alkali, alkaline earth, transition and heavy metal ions. The electrodes were successfully applied to the recovery of Sm3+ ion from tap water samples and also, as an indicator electrode, in potentiometric titration of samarium(III) ions.  相似文献   

18.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on 1,8-dibenzyl-1,3,6,8,10,13-hexaazacyclotetradecane-Ni(II) as a membrane carrier with unique selectivity toward thiocyanate is reported. The influence of membrane composition, pH and foreign anions were investigated. The sensor exhibits a Nernstian response for thiocyanate over a wide concentration range of 3.3×10−6 to 0.10 M, with a slope 58.4±0.3 mV per decade. The limit of detection is 3.0×10−6 M SCN. The sensor has a response time of <20 s and can be used for at least 2 months without any considerable divergence in potential. The proposed electrode shows fairly a good discriminating ability towards SCN ion in comparison to other anions. It was successfully applied to direct determination of thiocyanate in urine and saliva and it was also used as an indicator electrode in titration of thiocyanate with Ag+ ions.  相似文献   

19.
A novel fluorescent chemical sensor for the highly sensitive and selective determination of Fe3+ ions in aqueous solutions is prepared. The iron sensing system was prepared by incorporating 5-(8-hydroxy-2-quinolinylmethyl)-2,8-dithia-5-aza-2,6-pyridinophane (L) as a neutral Fe3+-selective fluoroionophore in the plasticized PVC membrane containing sodium tetraphenylborate as a liphophilic anionic additive. The response of the sensor is based on the strong fluorescence quenching of L by Fe3+ ions. At pH 5.5, the proposed sensor displays a calibration curve over a wide concentration range from 6.0 × 10−4 to 1.0 × 10−7 M, with a relatively fast response time of less than 2 min. In addition to a high stability and reproducibility, the sensor shows a unique selectivity toward Fe3+ ion with respect to common coexisting cations. The proposed fluorescence optode was applied to the determination of iron(III) content of straw of rice, spinach and different water samples. The fluorescent sensor was also used as a novel probe for Fe3+/Fe2+ speciation in aqueous solution.  相似文献   

20.
A new PVC membrane electrode for Co2+ based on N,N′-bis(salicylidene)-3,4-diaminotoluene, an excellent neutral carrier, has been fabricated using sodium tetraphenylborate (NaTPB) as an anionic excluder and dioctylphthalte (DOP) as a solvent mediator. The electrode exhibits a linear potential response in the concentration range of 7.9 × 10−8 to 1.0 × 10−1 M with a slope of 30 ± 0.2 mV per decade. The detection limit of the proposed sensor is 5.0 × 10−8 M and it can be used over a period of 5 months. The proposed sensor revealed good selectivity over a wide variety of other cations including alkali, alkaline earth, heavy and transition metals and could be used in the pH range of 2.0-9.0. This electrode was successfully applied for the determination of Co2+in real samples and as an indicator electrode in potentiometric titration of cobalt ions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号