首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Owing to its broad biological significance, the large-scale analysis of protein phosphorylation is more and more getting into the focus of proteomic research. Thousands of phosphopeptides can nowadays be identified using state-of-the-art tandem mass spectrometers in conjunction with sequence database searching, but localizing the phosphate group to a particular amino acid in the peptide sequence is often still difficult. Using 180 individually synthesized phosphopeptides with precisely known phosphorylation sites (p-sites), we have assessed the merits of the Mascot Delta Score (MD score) for the assignment of phosphorylation sites from tandem mass spectra (MS/MS) generated on four different matrix-assisted laser desorption ionization (MALDI) mass spectrometers including tandem time-of-flight (TOF/TOF), quadrupole time-of-flight, and ion trap mass analyzers. The results show that phosphorylation site identification is generally possible with false localization rates of about 10%. However, a comparison to previous work also revealed that phosphorylation site determination by MALDI MS/MS is less accurate than by ESI-MS/MS particularly if several and/or adjacent possible phosphorylation acceptor sites exist in a peptide sequence. We are making the tandem MS spectra and phosphopeptide collection available to the community so that scientists may adapt the MD scores reported here to their analytical environment and so that informatics developers may integrate the MD score into proteomic data analysis pipelines.  相似文献   

2.
In high-throughput proteomics, the bottom-up approach has become a widely used method for the identification of proteins that is based on tryptic peptide MS/MS analysis. Separation methodologies that use IEF of tryptic peptides have recently been introduced and provide an extra dimension of peptide separation. In addition to its great fractionation capability, tryptic peptide prefractionation by IEF can also increase the protein identification success. The pI information of the peptide gained can be successfully used in a post-database search filtering step. We introduce a filtering algorithm that is based on the comparison of the experimental and theoretical pI's to validate peptide identifications by MS/MS data search engines.  相似文献   

3.
A library consisting of 3766 MS(n) spectra of 1743 compounds, including 3126 MS2 spectra acquired mainly using ion trap (IT) and triple-quadrupole (QqQ) instruments, was composed of numerous collections/sources. Ionization techniques were mainly electrospray ionization and also atmospheric pressure chemical ionization and chemical ionization. The library was tested for the performance in identification of unknowns, and in this context this work is believed to be the largest of all known tests of product-ion mass spectral libraries. The MS2 spectra of the same compounds from different collections were in turn divided into spectra of 'unknown' and reference compounds. For each particular compound, library searches were performed resulting in selection by taking into account the best matches for each spectral collection/source. Within each collection/source, replicate MS2 spectra differed in the collision energy used. Overall, there were up to 950 search results giving the best match factors and their ranks in corresponding hit lists. In general, the correct answers were obtained as the 1st rank in up to 60% of the search results when retrieved with (on average) 2.2 'unknown' and 6.2 reference replicates per compound. With two or more replicates of both 'unknown' and reference spectra (the average numbers of replicates were 4.0 and 7.8, respectively), the fraction of correct answers in the 1st rank increased to 77%. This value is close to the performance of established electron ionization mass spectra libraries (up to 79%) found by other workers. The hypothesis that MS2 spectra better match reference spectra acquired using the same type of tandem mass spectrometer (IT or QqQ) was neither strongly proved nor rejected here. The present work shows that MS2 spectral libraries containing sufficiently numerous different entries for each compound are sufficiently efficient for identification of unknowns and suitable for use with different tandem mass spectrometers.  相似文献   

4.
Shotgun proteomics experiments require the collection of thousands of tandem mass spectra; these sets of data will continue to grow as new instruments become available that can scan at even higher rates. Such data contain substantial amounts of redundancy with spectra from a particular peptide being acquired many times during a single LC-MS/MS experiment. In this article, we present MS2Grouper, an algorithm that detects spectral duplication, assesses groups of related spectra, and replaces these groups with synthetic representative spectra. Errors in detecting spectral similarity are corrected using a paraclique criterion-spectra are only assessed as groups if they are part of a clique of at least three completely interrelated spectra or are subsequently added to such cliques by being similar to all but one of the clique members. A greedy algorithm constructs a representative spectrum for each group by iteratively removing the tallest peaks from the spectral collection and matching to peaks in the other spectra. This strategy is shown to be effective in reducing spectral counts by up to 20% in LC-MS/MS datasets from protein standard mixtures and proteomes, reducing database search times without a concomitant reduction in identified peptides.  相似文献   

5.
With the emergence of top-down proteomics, the ability to achieve high mass measurement accuracy on tandem MS/MS data will be beneficial for protein identification and characterization. (FT-ICR) Fourier transform ion cyclotron resonance mass spectrometers are the ideal instruments to perform these experiments with their ability to provide high resolution and mass accuracy. A major limitation to mass measurement accuracy in FT-ICR instruments arises from the occurrence of space charge effects. These space charge effects shift the cyclotron frequency of the ions, which compromises the mass measurement accuracy. While several methods have been developed that correct these space charge effects, they have limitations when applied to MS/MS experiments. It has already been shown that additional information inherent in electrospray spectra can be used for improved mass measurement accuracy with the use of a computer algorithm called DeCAL (deconvolution of Coulombic affected linearity). This paper highlights a new application of the strategy for improved mass accuracy in tandem mass analysis. The results show a significant improvement in mass measurement accuracy on complex electron capture dissociation spectra of proteins. We also demonstrate how the improvement in mass accuracy can increase the confidence in protein identification from the fragment masses of proteins acquired in MS/MS experiments.  相似文献   

6.
Searchable libraries of MS/MS spectra, obtained using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with data-dependent scan mode switching on both quadrupole ion trap and triple-quadrupole mass spectrometers in conjunction with electrospray ionization, are presented. The effects on library search scores of changing the parameters for producing collision-induced dissociation (CID) on both instrument types are systematically evaluated. These observations serve as a basis for determining a universal set of conditions for building MS/MS libraries. A group of 19 closely related steroids was used. The ability to obtain library-searchable spectra at low concentrations is demonstrated for the analysis of a sample of progesterone spiked with hydroxyprogesterone impurities at 0.1 and 0.01%.  相似文献   

7.
Spectral counting has become a widely used approach for measuring and comparing protein abundance in label-free shotgun proteomics. However, when analyzing complex samples, the ambiguity of matching between peptides and proteins greatly affects the assessment of peptide and protein inventories, differentiation, and quantification. Meanwhile, the configuration of database searching algorithms that assign peptides to MS/MS spectra may produce different results in comparative proteomic analysis. Here, we present three strategies to improve comparative proteomics through spectral counting. We show that comparing spectral counts for peptide groups rather than for protein groups forestalls problems introduced by shared peptides. We demonstrate the advantage and flexibility of this new method in two datasets. We present four models to combine four popular search engines that lead to significant gains in spectral counting differentiation. Among these models, we demonstrate a powerful vote counting model that scales well for multiple search engines. We also show that semi-tryptic searching outperforms tryptic searching for comparative proteomics. Overall, these techniques considerably improve protein differentiation on the basis of spectral count tables.  相似文献   

8.
Quantitative analysis of liquid chromatography (LC)-mass spectrometry (MS) and tandem mass spectrometry (MS/MS) data is essential to many proteomics studies. We have developed MASIC(2) to accurately measure peptide abundances and LC elution times in LC-MS/MS analyses. This software program uses an efficient processing algorithm to quickly generate mass specific selected ion chromatograms from a dataset and provides an interactive browser that allows users to examine individual chromatograms with a variety of options.  相似文献   

9.
This paper describes an algorithm to apply proteotypic peptide sequence libraries to protein identifications performed using tandem mass spectrometry (MS/MS). Proteotypic peptides are those peptides in a protein sequence that are most likely to be confidently observed by current MS-based proteomics methods. Libraries of proteotypic peptide sequences were compiled from the Global Proteome Machine Database for Homo sapiens and Saccharomyces cerevisiae model species proteomes. These libraries were used to scan through collections of tandem mass spectra to discover which proteins were represented by the data sets, followed by detailed analysis of the spectra with the full protein sequences corresponding to the discovered proteotypic peptides. This algorithm (Proteotypic Peptide Profiling, or P3) resulted in sequence-to-spectrum matches comparable to those obtained by conventional protein identification algorithms using only full protein sequences, with a 20-fold reduction in the time required to perform the identification calculations. The proteotypic peptide libraries, the open source code for the implementation of the search algorithm and a website for using the software have been made freely available. Approximately 4% of the residues in the H. sapiens proteome were required in the proteotypic peptide library to successfully identify proteins.  相似文献   

10.
Gel-based matrix-assisted laser desorption ionization-time of flight tandem mass spectrometer (MALDI TOF/TOF MS) is one of the dominant methods of current proteomics, utilizing both peptide mass fingerprinting (PMF) and peptide fragment fingerprinting (PFF) for protein identification on a spot-to-spot basis. However, the unique impact of the quality of the corresponding mass spectrometry spectra remains largely unreported, and has motivated the development and use of an automatic spectra-assessment method. In this study, a multi-variant regression approach has been utilized to assess spectral quality for both PMF and PFF spectra obtained from MALDI TOF/TOF MS. The assessment index has been applied to investigations of MASCOT search results. Systematic examination of two large-scale sets of human liver tissue data has proved that spectral quality was a key factor in significant matching. Based on large-scale investigations on individual PMF search, individual PFF search and their combination, respectively, the filtering of bad quality spectra or spots proves to be an efficient way to improve search efficiency of all search modes in MASCOT. Meanwhile, a validation method based on score differences between normal and decoy (reverse or random) database searches is proposed to precisely define the positive matches. Further analysis showed that spectral quality assessment was also efficient in representing the quality of 2-DE gel spots and promoted the discovery of potential post-translation modifications.  相似文献   

11.
The identification of hemoglobin (Hb) variants is usually performed by means of different analytical steps and methodologies. Phenotypic methods, such as gel electrophoresis and high performance liquid chromatography, are used to detect the different electrophoretic or chromatographic behaviors of hemoglobin variants in comparison to HbA0 used as a control. These data often need to be combined with mass spectrometry analyses of intact globins and their tryptic peptide mixtures. As an alternative to a 'step-by-step' procedure, we have developed a 'single step' approach for the identification of Hb variants present in biological samples. This is based on the microHPLC-ESI-MS/MS analysis of the peptide mixture generated by a tryptic digestion of diluted Hb samples and an in-house new database containing solely the variant tryptic peptide of known human Hb variants. The experimental results (full MS and MS/MS spectra) are correlated with theoretical mass spectra generated from our in-house-built variant peptide database (Hbp) using the SEQUEST algorithm. Simple preparation of samples and an automated identification of the variant peptide are the main characteristics of this approach, making it an attractive method for the detection of Hb variants at the routine clinical level. We have analyzed 16 different samples, each containing a different known variant of hemoglobin.  相似文献   

12.
The quantity and variable quality of data that can be generated from liquid chromatography (LC)/mass spectrometry (MS)-based proteomics analyses creates many challenges in interpreting the spectra in terms of the actual proteins in a complex sample. In spite of improvements in algorithms that match putative peptide sequences to MS/MS spectra, the assembly of these lists of possible or probable peptides into a 'correct' set of proteins is still problematic. We have observed a trend in a simple relationship, derived from standard database search outputs, which can be useful in assessing the quality of a MS/MS-based protein identification. Specifically, the ratio of the protein score and number of non-redundant peptides, or average peptide score (APS), can facilitate initial filtering of database search results in addition to providing a useful measure of confidence for the proteins identified. This parameter has been applied to results from the analysis of multi-protein complexes derived from pull-down experiments analyzed using a two-dimensional LC/MS/MS workflow. In particular, the complex list of protein identifications derived from a drug affinity pull-down with immobilized ampicillin and an E. coli lysate was greatly simplified by applying the APS as a filter, allowing for facile identification of the penicillin-binding proteins known to interact with ampicillin. Furthermore, an APS threshold can be used for any data sets derived from electrospray ionization (ESI)- or matrix-assisted laser desorption/ionization (MALDI)-MS/MS experiments and is also not specific to any database search program.  相似文献   

13.
Electrospray ionization coupled with collision‐induced dissociation (CID) and tandem mass spectrometry (MS/MS) is a commonly used technique to analyze the chemical composition of steroids. However, steroids are structurally similar compounds, making it difficult to interpret their product‐ion spectra. Electron transfer dissociation (ETD), a relatively new technique for protein and peptide fragmentation, has been shown to provide more detailed structural information. In this study, we compared the ability of CID with that of ETD to differentiate between eight 3,20‐dioxosteroids that had been derivatizated with a quaternary ammonium salt, Girard reagent P (GirP), at room temperature or after exposure to microwave irradiation to generate doubly charged ions. We found that the derivatization of steroid with GirP hydrazine occurred in less than 10 min when the reaction was carried out in the presence of microwave irradiation compared to 30 min when the reaction was carried out at room temperature. According to the MS/MS spectra, CID provided rich, structurally informative ions; however, the spectra were complex, thereby complicating the peak assignment. In contrast, ETD generated simpler spectra, making it easier to recognize individual peaks. Remarkably, both CID and ETD were allowed to differentiate of steroid isomers, 17α‐hydroxyprogesterone (17OHP) and deoxycorticosterone (DOC), but the signature ions obtained from CID were less intense than those generated by ETD, which generated much clearer spectra. These results indicate that ETD in conjunction with CID can provide more structural information for precise characterization of steroids. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
The goal of this work was to evaluate the improvement in proteome coverage of complex protein mixtures gained by analyzing samples using both LC/ESI/MS/MS and LC/MALDI/MS/MS. Parallel analyses of a single sample were accomplished by interfacing a Probot fractionation system with a nanoscale LC system. The Probot was configured to perform a post-column split such that a fraction (20%) of the column effluent was sent for on-line LC/ESI/MS/MS data acquisition, and the majority of the sample (80%) was mixed with a matrix solution and deposited onto the MALDI target plate. The split-flow approach takes advantage of the concentration sensitive nature of ESI and provides sufficient quantity of sample for MALDI/MS/MS. Hybrid quadrupole time-of-flight mass spectrometers were used to acquire LC/ESI/MS/MS data and LC/MALDI/MS/MS data from a tryptic digest of a preparation of mammalian mitochondrial ribosomes. The mass spectrometers were configured to operate in a data dependent acquisition mode in which precursor ions observed in MS survey scans are automatically selected for interrogation by MS/MS. This type of acquisition scheme maximizes the number of peptide fragmentation spectra obtained and is commonly referred to as shotgun analysis. While a significant degree of overlap (63%) was observed between the proteins identified in the LC/ESI/MS/MS and LC/MALDI/MS/MS data sets, both unique peptides and unique proteins were observed by each method. These results demonstrate that improved proteome coverage can be obtained using a combination of these ionization techniques.  相似文献   

15.
A growing number of peptides are being used today in bioanalytical laboratories. Because of this, there is an increasing interest in the development of highly sensitive, specific and robust liquid chromatography/tandem mass spectrometry (LC/MS/MS) assays for the quantitative analysis of peptides in biological samples. Among the mass spectrometers previously used for peptide quantification, triple quadrupole mass spectrometers are generally not considered the instrument of choice. With this instrumentation, collision cascades or multiple fragmentations tend to generate multiple peaks that have weak intensities. This leads to a loss in detection sensitivity. However, in cases where immonium product ions were formed in abundance, it was found that peptide quantification succeeded. A common feature of these peptides is their intra-loop structure. To elucidate the usefulness of this feature in fragmentation, several peptide analytes with intra-chain disulfide bonds were investigated in this study, including a newly synthesized analog having a single amino acid substitution. The results presented here indicate that abrupt bond cleavage from the intra-loop structure of peptides could be one of the premises for intense immonium ion generation. In contrast, any preferential cleavage of peptide bonds (e.g., proline effect) that gives rise to a linearized sequence would break the intactness of the loop and prevent it from completely dissociating. In addition, the utilization of immonium product ions in LC/MS/MS was demonstrated for the determination of peptides with intra-chain disulfide bonds in biological fluids.  相似文献   

16.
Capillary separations interfaced to tandem mass spectrometry provide a very powerful tool for the characterization of biological macromolecules such as proteins and peptides. The development of real time data-dependent data acquisition has further enhanced the capability of this method. However, the application of this technique to fast capillary separations has been limited by the relatively slow spectral acquisition speed available on scanning mass spectrometers. In this work, an ion trap storage/reflectron time-of-flight mass spectrometer (IT/reTOF-MS) has been used as an on-line tandem mass detector for capillary high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) separations of peptide mixtures including a protein digest. By taking advantage of the nonscanning property of the time-of-flight mass spectrometer, a fast spectral acquisition rate has been achieved. This fast spectral acquisition rate, combined with a new protocol that speeds up tickle voltage optimization, has provided MS/MS spectra for multiple components in a hemoglobin digest during one liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) run. Further, the IT/reTOF-MS has the speed to provide MS/MS spectra for multiple components in a CE separation of a synthetic peptide mixture within one CE/MS/MS run.  相似文献   

17.
Mass spectral libraries represent versatile tools for the identification of small bioorganic molecules. Libraries based on electron impact spectra are rated robust and transferable. Tandem mass spectral libraries are often considered to work properly only on the instrument that has been used to build the library. An exception from that rule is the ‘Wiley Registry of Tandem Mass Spectral Data, MSforID’. In various studies with data sets from different kinds of tandem mass spectrometric instruments, the outstanding sensitivity and robustness of this tandem mass spectral library search approach was demonstrated. The instrumental platforms tested, however, mainly included various tandem‐in‐space instruments. Herein, the results of a multicenter study with a focus on upfront and tandem‐in‐time fragmentation are presented. Five laboratories participated and provided fragment ion mass spectra from the following types of mass spectrometers: time‐of‐flight (TOF), quadrupole–hexapole–TOF, linear ion trap (LIT), 3‐D ion trap and LIT–Orbitrap. A total number of 1231 fragment ion mass spectra were collected from 20 test compounds (amiloride, buphenin, cinchocaine, cyclizine, desipramine, dihydroergotamine, dyxirazine, dosulepin, ergotamine, ethambutol, etofylline, mefruside, metoclopramide, phenazone, phentermine, phenytoin, sulfamethoxazole, sulfamoxole, sulthiame and tetracycline) on seven electrospray ionization instruments using 18 different instrumental configurations for fragmentation. For 1222 spectra (99.3%), the correct compound was retrieved as the best matching compound. Classified matches (matches with ‘relative average match probability’ >40.0) were obtained for 1207 spectra (98.1%). This high percentage of correct identifications clearly supports the hypothesis that the tandem mass spectral library approach tested is a robust and universal identification tool. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
It has been observed that a modified peptide and its non-modified counterpart, when analyzed with reverse phase liquid chromatography, usually share a very similar elution property [1–3]. Inasmuch as this property is common to many different types of protein modifications, we propose an informatics-based approach, featuring the generation of segmental average mass spectra (saMS), that is capable of locating different types of modified peptides in two-dimensional liquid chromatography–mass spectrometric (LC–MS) data collected for regular protease digests from proteins in gels or solutions. To enable the localization of these peptides in the LC–MS map, we have implemented a set of computer programs, or the saMS package, that perform the needed functions, including generating a complete set of segmental average mass spectra, compiling the peptide inventory from the Sequest/TurboSequest results, searching modified peptide candidates and annotating a tandem mass spectrum for final verification. Using ROCK2 as an example, our programs were applied to identify multiple types of modified peptides, such as phosphorylated and hexosylated ones, which particularly include those peptides that could have been ignored due to their peculiar fragmentation patterns and consequent low search scores. Hence, we demonstrate that, when complemented with peptide search algorithms, our approach and the entailed computer programs can add the sequence information needed for bolstering the confidence of data interpretation by the present analytical platforms and facilitate the mining of protein modification information out of complicated LC–MS/MS data.  相似文献   

19.
Quadrupole ion trap scanning parameters for performing bottom-up proteomics in a data-dependent fashion were evaluated on a Finnigan LCQ Deca mass spectrometer. Evaluation of parameters such as the number of averaged full scans, the number of averaged MS/MS scans, and ion injection times were necessary for acquiring high quality MS/MS spectra that yield favorable b and y ion coverage and high correlation to proteins using database searching algorithms. In this study, we demonstrated how the duty cycle of the mass spectrometer affects the number of peptides that can be successfully identified by SEQUEST using a model system of tryptic BSA peptides to mimic a typical complex mixture associated with bottom-up proteomics. The number of averaged scans and the duration of ion accumulation in the trap had a significant effect on the quality of acquired MS/MS spectra. For example, by increasing the ion injection time from 500 ms to 600 ms, peptide HLVDEPQNLIK improved from being improperly identified to being correctly identified with a SEQUEST cross-correlation score of 3.60. As a result of these experiments, we have devised the following set of ion trap parameters for performing bottom-up proteomics analysis in our laboratory: Three averaged full scans, five averaged MS/MS scans, and a maximum ion injection time of 600 ms.  相似文献   

20.
High-throughput proteomics has typically relied on protein identification based on MALDI-MS peptide maps of proteolytic digests of 2D-gel-separated proteins. This technique, however, requires significant sequence coverage in order to achieve a high level of confidence in the identification. Tandem MS data have the advantage of requiring fewer peptides (2) for high confidence identification, assuming adequate MS/MS sequence coverage. MALDI-MS/MS techniques are becoming available, but can still be problematic because of the difficulty of inducing fragment ions of a singly charged parent ion. Electrospray ionization, however, has the advantage of generating multiply charged species that are more readily fragmented during MS/MS analysis. Two electrospray/tandem mass spectrometry-based approaches, nanovial-ESI-MS/MS and LC-MS/MS, are used for high throughput proteomics, but much less often than MALDI-MS and peptide mass fingerprinting. Nanovial introduction entails extensive manual manipulation and often shows significant chemical background from the in-gel digest. LC-MS has the advantages that the chemical background can be removed prior to analysis and the analytes are concentrated during the separation, resulting in more abundant analyte signals. On the other hand, LC-MS can often be time intensive. Here, we report the incorporation of on-line sample clean-up and analyte concentration with a high-throughput, chip-based, robotic nano-ESI-MS platform for proteomics studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号