首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 71 毫秒
1.
As is well-known, trace elements, especially metals, play an important role in the pathogenesis of many disorders. The topographic and quantitative elemental analysis of pathologically changed tissues may shed some new light on processes leading to the degeneration of cells in the case of selected diseases. An ideal and powerful tool for such purpose is the Synchrotron Microbeam X-ray Fluorescence technique. It enables the carrying out of investigations of the elemental composition of tissues even at the single cell level.

The tissue samples for histopathological investigations are routinely fixed and embedded in paraffin. The authors try to verify the usefulness of such prepared tissue sections for elemental analysis with the use of X-ray fluorescence microscopy. Studies were performed on rat brain samples. Changes in elemental composition caused by fixation in formalin or paraformaldehyde and embedding in paraffin were examined.

Measurements were carried out at the bending magnet beamline L of the Hamburger Synchrotronstrahlungslabor HASYLAB in Hamburg.

The decrease in mass per unit area of K, Br and the increase in P, S, Fe, Cu and Zn in the tissue were observed as a result of the fixation. For the samples embedded in paraffin, a lower level of most elements was observed. Additionally, for these samples, changes in the composition of some elements were not uniform for different analyzed areas of rat brain.  相似文献   


2.
The analytical potential of double focusing-inductively coupled plasma-mass spectrometry (DF-ICP-MS) for total elemental analysis in clinical samples (serum, blood, urine and other biological fluids), tissues and food products is illustrated by reviewing typical applications recently published. Also, the use of DF-ICP-MS as specific detector for trace element speciation in biological samples is discussed. After adequate separation of interferences in the chromatographic column, low resolution measurements (R = 300) can be used to provide enhanced sensitivities of more than 100 times compared with quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS). This capability is extremely valuable in speciation studies. Also, the use of DF-ICP-MS at low resolution could provide very precise isotope ratio measurements for isotope dilution analysis due to the ‘flat topped’ peaks obtained at this resolution. Unfortunately, the literature on these last two issues is rather scarce so far, in spite of their extremely high analytical possibilities for biological research. Moreover, the bright future of DF-ICP-MS as a most powerful multielemental detector for trace element applications in biological systems will be highlighted. Apart from applications detailed above other important application fields can be envisaged. In particular, we will speculate on its possible use to confirm/establish ‘reference values’ of trace element content in ‘normal’ populations and so to help to diagnose health and disease status, related with trace element total content or their speciation in clinical specimens.  相似文献   

3.
Laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) is well established as a sensitive trace and ultratrace analytical technique with multielement capability for bioimaging of metals and studying metallomics in biological and medical tissue. Metals and metalloproteins play a key role in the metabolism and formation of metal‐containing deposits in the brain but also in the liver. In various diseases, analysis of metals and metalloproteins is essential for understanding the underlying cellular processes. LA–ICP–MS imaging (LA–ICP–MSI) combined with other complementary imaging techniques is a sophisticated tool for investigating the regional and cellular distribution of metals and related metal‐containing biomolecules. On the basis of successful routine techniques for the elemental bioimaging of cryosections by LA–ICP–MSI with a spatial resolution between 200 and ~10 µm, the further development used online laser microdissection ICP–MSI to study the metal distribution in small biological sample sections (at the cellular level from 10 µm to the submicrometer range). The use of mass spectrometric imaging of metals and also nonmetals is demonstrated on a series of biological specimens. This article discusses the state of the art of bioimaging of metals in thin biological tissue sections by LA–ICP–MSI with spatial resolution at the micrometer scale, future developments and prospects for quantitative imaging techniques of metals in the nanometer range. In addition, combining quantitative elemental imaging by LA/laser microdissection–ICP–MSI with biomolecular imaging by matrix‐assisted laser desorption/ionization–MSI will be challenging for future life science research. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon).Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.  相似文献   

5.
Total reflection X-ray fluorescence analysis (TXRF) offers a nondestructive qualitative and quantitative analysis of trace elements. Due to its outstanding properties TXRF is widely used in the semiconductor industry for the analysis of silicon wafer surfaces and in the chemical analysis of liquid samples. Two problems occur in quantification: the large statistical uncertainty in wafer surface analysis and the validity of using an internal standard in chemical analysis. In general TXRF is known to allow for linear calibration. For small sample amounts (low nanogram (ng) region) the thin film approximation is valid neglecting absorption effects of the exciting and the detected radiation. For higher total amounts of samples deviations from the linear relation between fluorescence intensity and sample amount can be observed. This could be caused by the sample itself because inhomogeneities and different sample shapes can lead to differences of the emitted fluorescence intensities and high statistical errors. The aim of the study was to investigate the elemental distribution inside a sample. Single and multi-element samples were investigated with Synchrotron-radiation-induced micro X-ray Fluorescence Analysis (SR-μ-XRF) and with an optical microscope. It could be proven that the microscope images are all based on the investigated elements. This allows the determination of the sample shape and potential inhomogeneities using only light microscope images. For the multi-element samples, it was furthermore shown that the elemental distribution inside the samples is homogeneous. This justifies internal standard quantification.  相似文献   

6.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science.  相似文献   

7.
The unique properties of synchrotron radiation, such as high incident flux combined with low divergence, its linear polarization and energy tunability, make it an ideal excitation source for total reflection X-ray fluorescence (TXRF) spectroscopy in order to non-destructively detect trace impurities of transition metals on Si wafer surfaces. When used with a detector suitable for the determination of low energy radiation this technique can be extended to the detection of low-Z elements, such as Al, Na and Mg. Experiments have been performed at SSRL Beamline 3-3, a bending magnet beamline using monochromatic radiation from a double multilayer monochromator. The wafer was mounted vertically in front of the detector, which was aligned along the linear polarization vector of the incoming synchrotron radiation. This configuration allows the detector to accept a large solid angle as well as to take advantage of the reduced scattered X-ray intensity emitted in the direction of the linear polarization vector. A comparison between droplet samples and spin coated samples was done, in order to compare the capabilities of vapor phase decomposition (VPD-TXRF) with conventional SR-straight-TXRF. Detection limits in the range of 50 fg corresponding to 2E10 atoms/cm2 have been obtained for Na. The spin coated samples, prepared from solutions containing an equal amount of Na, Mg and Al showed an unexpected result when performing a scan of the angle of incidence of the incoming X-rays suggesting a different adsorption behavior of the elements in a multielement solution on the wafer surface. The observation of this behavior is important because the spin coating technique is the standard method for the preparation of surface standards in semiconductor quality control. This effect could be characteristic of the Na, Mg, Al solution used, but the angle dependence of the fluorescence signal of a standard should always be investigated before using the standard for calibration of the apparatus and quantification.  相似文献   

8.
An approach for the determination of trace element concentrations in high purity metals, using an inductively coupled plasma mass spectrometer (ICP-MS) with a laser-ablation system for direct solid sample introduction after calibration with nebulized liquid standards was made. Due to the inherent differences in the rate of sample introduction with laser-ablation and pneumatic nebulization, a matrix element must be used as an internal standard. This is problematical for elements that have no isotope with a relative abundance of less than 0.1 %, since the ion signals would be too high for direct measurement, and reduction of the ablation rate would compromise the sensitivity for trace elements. Due to the high stability of ICP-unit and mass filter of the instrument used, it was found that the tail of a mass-peak of the matrix element could be used as an internal standard. Therefore, a position at –0.5 amu from the matrix-isotope (e.g. 62.5Cu in copper samples) was used for internal standardization. The standard deviation of this signal in a period of 2.5 h was 3.6% RSD with no notable drift when the laser ablation was used for sample introduction. The calibration of the matrix-element by nebulizing liquid standards showed that the ion signal measured on the peak-tail is directly proportional to the element concentration in the ICP. This indicates that the peak shape is not only stable, but also independent of the peak height. The advantages of this method lie in the easy preparation of calibration standards for quantitative measurements with a laser-ablation system and access to homogeneous standards for materials, that are difficult to homogenize in the solid state. The calibration of the traces is performed relatively to a fixed concentration of the matrix element. Calibrations were carried out for trace concentrations in high purity copper and good recoveries were obtained for high-purity reference standards. Received: 23 February 1998 / Revised: 20 July 1998 / Accepted: 25 July 1998  相似文献   

9.
An approach for the determination of trace element concentrations in high purity metals, using an inductively coupled plasma mass spectrometer (ICP-MS) with a laser-ablation system for direct solid sample introduction after calibration with nebulized liquid standards was made. Due to the inherent differences in the rate of sample introduction with laser-ablation and pneumatic nebulization, a matrix element must be used as an internal standard. This is problematical for elements that have no isotope with a relative abundance of less than 0.1 %, since the ion signals would be too high for direct measurement, and reduction of the ablation rate would compromise the sensitivity for trace elements. Due to the high stability of ICP-unit and mass filter of the instrument used, it was found that the tail of a mass-peak of the matrix element could be used as an internal standard. Therefore, a position at –0.5 amu from the matrix-isotope (e.g. 62.5Cu in copper samples) was used for internal standardization. The standard deviation of this signal in a period of 2.5 h was 3.6% RSD with no notable drift when the laser ablation was used for sample introduction. The calibration of the matrix-element by nebulizing liquid standards showed that the ion signal measured on the peak-tail is directly proportional to the element concentration in the ICP. This indicates that the peak shape is not only stable, but also independent of the peak height. The advantages of this method lie in the easy preparation of calibration standards for quantitative measurements with a laser-ablation system and access to homogeneous standards for materials, that are difficult to homogenize in the solid state. The calibration of the traces is performed relatively to a fixed concentration of the matrix element. Calibrations were carried out for trace concentrations in high purity copper and good recoveries were obtained for high-purity reference standards. Received: 23 February 1998 / Revised: 20 July 1998 / Accepted: 25 July 1998  相似文献   

10.
Examining chemical and structural characteristics of micro-features in complex tissue matrices is essential for understanding biological systems. Advances in multimodal chemical and structural imaging using synchrotron radiation have overcome many issues in correlative imaging, enabling the characterization of distinct microfeatures at nanoscale resolution in ex vivo tissues. We present a nanoscale imaging method that pairs X-ray ptychography and X-ray fluorescence microscopy (XFM) to simultaneously examine structural features and quantify elemental content of microfeatures in complex ex vivo tissues. We examined the neuropathological microfeatures Lewy bodies, aggregations of superoxide dismutase 1 (SOD1) and neuromelanin in human post-mortem Parkinson''s disease tissue. Although biometals play essential roles in normal neuronal biochemistry, their dyshomeostasis is implicated in Parkinson''s disease aetiology. Here we show that Lewy bodies and SOD1 aggregates have distinct elemental fingerprints yet are similar in structure, whilst neuromelanin exhibits different elemental composition and a distinct, disordered structure. The unique approach we describe is applicable to the structural and chemical characterization of a wide range of complex biological tissues at previously unprecedented levels of detail.

Structural and chemical characterisation of microfeatures in unadulterated Parkinson''s disease brain tissue using synchrotron nanoscale XFM and ptychography.  相似文献   

11.
Zhou  Jing  Zhang  Yingxue  Xu  Baiqiu  Zhang  Xu  Cui  Shufen 《Chromatographia》2014,77(17):1213-1221

In this study, a liquid-phase solvent bar micro-extraction technique was used to investigate both the extraction and back-extraction processes of the target analyte. A novel concentration curve method and a classic time curve method, used under the same experimental conditions, verified the symmetry between the extraction process (target analyte moves from sample matrix to the organic solvent-based extraction phase) and the back-extraction process (target analyte moves from organic solvent to the sample matrix), providing the basis to use the target analyte in the back-extraction process to calibrate its extraction process. A quantitative calibration can be achieved using back extraction on the target analyte from the blank sample matrix in the organic solvent. Information from the process of back extraction of the target analyte, such as the time constant a, can be directly used to calculate the initial concentration of the target analyte in the sample matrix. This new kinetic calibration method employs a liquid-phase solvent bar micro-extraction technique combined with high-performance liquid chromatography with a diode array detector (HPLC-DAD) and was successfully used to analyze three local anesthetics in biological samples; it extends the application of the kinetic calibration to HPLC-DAD and establishes a novel, simple and accurate method to determine the concentration of the free drug in biological samples and its protein-binding ratio.

  相似文献   

12.
Synchrotron radiation induced TXRF allows the nondestructive investigation of low Z contaminations on Si wafer surfaces at trace levels required by the semiconductor industry. The PTB (Physikalisch Technische Bundesanstalt) U180 undulator beamline at BESSY II, equipped with a plane grating monochromator ensuring an energy resolving power EE between 500 and 5000, can be operated either in wiggler mode for photon energies up to 1.7 keV to excite Al, Mg and Na efficiently, or in undulator mode, i.e. using one of the first odd U180 harmonics, to obtain intensive low energy radiation below 0.7 keV to excite carbon, nitrogen and oxygen. The specific feature of the beamline is its high spectral purity that allows for fundamental investigations. The TXRF wafer chamber of the Atominstitut was used for the experiments with a sidelooking Si(Li) detector with the wafer arranged vertically to take advantage of the linear polarization for background reduction. The energy dependence of the resonant Raman scattering, which is a limiter for the determination of Al at ultra trace levels excited with energies just below the Si absorption edge was studied as well as the influence of the incidence angle on the Raman peak. Droplet samples containing boron were measured and the detection limit of 3 ng determined. A single Carbon layer (5 nm) and a C–Ni–C multilayer sample on a Si wafer were characterized and it was shown that the thickness and density of these layers could be determined.  相似文献   

13.
An absorption intracavity laser spectrometer with two types of sample vaporization systems (graphite furnace electrothermal atomizer or laser sampler) is described that can be used for the determination of trace amounts of metals (Al, Cr, Fe and Mn) in liquid samples and at the surface of solid targets. The limits of detection for the elements tested are lower than those obtained by modern conventional spectrometers. The examined technique provides a wide dynamic range of linear standard calibration curves.  相似文献   

14.
The main scope of our work was to investigate the usefulness of the PROZA correction method and CALIBRATION CURVE construction for quantitative X-ray microanalysis of biological soft, freeze-dried tissues. The test samples with a known elemental concentration of NaCl, MgCl2, KH2PO4 and Na2SO4 were prepared on the basis of 20% porcine skin gelatine. A control sample containing 20% gelatine was used for sulphur subtraction. Dissolved gelatine solutions were cooled with liquid nitrogen and then cut in cryomicrotome into 16µm thick slices. The sections were lyophilised, coated with carbon and analysed by means of a scanning electron microscope combined with an energy dispersive (ED) spectrometer. The homogeneity of the prepared samples was verified using the Fishers test. Only homogenous samples were used for calibration. The significance of the (z) (PROZA) correction method for biological sample analysis was verified by comparing the prepared standard and entering it into the Voyager computer program memory with the remaining samples of a known elemental content. The differences between the standard and the samples were noted for all elements analysed. There was no sample matching the standard after the PROZA correction procedure. A high correlation r factor (above 0.99) for all analysed elements indicates that CALIBRATION CURVES construction could be suitable for quantitative X-ray microanalysis of biological samples.  相似文献   

15.
An absorption intracavity laser spectrometer with two types of sample vaporization systems (graphite furnace electrothermal atomizer or laser sampler) is described that can be used for the determination of trace amounts of metals (Al, Cr, Fe and Mn) in liquid samples and at the surface of solid targets. The limits of detection for the elements tested are lower than those obtained by modern conventional spectrometers. The examined technique provides a wide dynamic range of linear standard calibration curves.  相似文献   

16.
A preconcentration method incorporated with neutron activation analysis was developed for the accurate determination of trace metals in biological and environmental samples. Bismuth diethyldithiocarbamate, thallium diethyldithiocarbarnate, and ammonium pyrrolidinedithiocarbamate were used as the preconcentration agents for three groups of metals. Trace metals were enriched and interfering elements such as Na, Br, P. K. etc. were removed simultaneously during the preconcentration process so that the sensitivity for each metal was greatly improved. Optimal conditions for sample digestion, group preconcentration of trace metals and neutron activation analysis of biological and environmental samples were discussed.  相似文献   

17.
We report on the application of laser-induced breakdown spectroscopy (LIBS) to the analysis of important minerals and the accumulation of potentially toxic elements in calcified tissue, to trace e.g. the influence of environmental exposure, and other medical or biological factors. This theme was exemplified for quantitative detection and mapping of Al, Pb and Sr in representative samples, including teeth (first teeth of infants, second teeth of children and teeth of adults) and bones (tibia and femur). In addition to identifying and quantifying major and trace elements in the tissues, one- and two-dimensional profiles and maps were generated. Such maps (a) provide time/concentration relations, (b) allow to follow mineralisation of the hydroxyapatite matrix and the migration of the elements within it and (c) enable to identify disease states, such as caries in teeth. In order to obtain quantitative calibration, reference samples in the form of pressed pellets with calcified tissue-equivalent material (majority compound of pellets is CaCO3) were used whose physical properties closely resembled hydroxyapatite. Compounds of Al, Sr and Pb were added to the pellets, containing atomic concentrations in the range 100–10 000 ppm relative to the Ca content of the matrix. Analytical results based on this calibration against artificial samples for the trace elements under investigation agree with literature values, and with our atomic absorption spectroscopy (AAS) cross-validation measurements.  相似文献   

18.
The use of electrothermal vaporisation (ETV) from a graphite furnace as a means of sample introduction in inductively coupled plasma mass spectrometry (ICP-MS) permits the direct analysis of solid samples. A multi-step furnace temperature programme is used to separate the vaporisation of the target element(s) and of the matrix components from one another. Sometimes, a chemical modifier is used to enable a higher thermal pre-treatment temperature, by avoiding premature analyte losses (stabilisation) or promoting the selective volatilisation of matrix components. In almost all instances, accurate results can be obtained via external calibration or single standard addition using an aqueous standard solution. Absolute limits of detection are typically ~1 pg, which corresponds to 1 ng/g for a typical sample mass of 1 mg. Real-life applications carried out in the author's lab are used to illustrate the utility of this approach. These applications aim at trace element determination in industrial and environmental materials. The industrial materials analysed include different types of plastics - Carilon, polyethylene, poly(ethyleneterephtalate) and polyamide - and photo- and thermographic materials. As samples from environmental origin, plant material, animal tissue and sediments were investigated. Some applications aimed at a multi-element determination, while in other, the content of a single, but often challenging, element (e.g., Si or S) had to be measured. ETV-ICP-MS was also used in elemental speciation studies. Separation of Se-containing proteins was accomplished using polyacrylamide gel electrophoresis (PAGE). Subsequent quantification of the Se content in the protein spots was carried out using ETV-ICP-MS. As the volatilisation of methylmercury and inorganic mercury could be separated from one another with respect to time, no chromatographic or electrophoretic separation procedure was required, but ETV-ICP-MS as such sufficed for Hg speciation in fish tissue.  相似文献   

19.
A method has been developed for the determination of relevant trace impurities (alkali, alkaline and transition metals) in high purity quartz by ion-chromatography. In situ reagent (HF) purification and simultaneous sample dissolution was achieved in a multichannel vapour phase digestion assembly. Twenty-one samples can be digested at a time in this vapour phase system. Significant decrease in the process blank levels for all the analytes was observed. Drastic reduction (250 times) of NH4+ blank was achieved in the described vapour phase digestion, which enables the determination of trace concentration of sodium in high purity quartz. After volatilisation of the matrix and unreacted HF, the clear water leached solutions were injected into an ion-chromatograph equipped with conductivity detector for the determination of alkali and alkaline earth metals. In the case of transition metals, the trace residues were leached with 10 mM HCl and after separation on a mixed bed analytical column (IonPac CS5) were detected by spectrophotometry after post column derivatisation using 4-(2-pyridylazo)resorcinol (PAR). The accuracy of the result was checked by their comparison with those obtained by independent methods like inductively coupled plasma (ICP) MS and ICP atomic emission spectrometry. The achievable detection limits are between 0.4 ng/g (Li) and 22 ng/g (Mn). The application of the method to the determination of the above trace metals in two high-purity-grade quartz samples is demonstrated.  相似文献   

20.
Paints and coatings are frequently encountered as types of materials that are submitted to forensic science laboratories as a result of trace evidence transfers. The aim of this study was to develop a method to complement the commonly used techniques in a forensic laboratory in order to better characterize these samples for forensic purposes. A laser ablation method has been used to simultaneously sample several layers directly prior to introduction into an inductively coupled plasma-mass spectrometer for the detection and quantification of the trace metals present in the layer(s). Time-resolved analysis plots displaying the elemental response and quantification of selected metals are compared to associate/discriminate paint samples. Matrix-matched standards were successfully incorporated into the analysis scheme for quantification of lead in the solid paint samples. Preparation of new matrix-matched standards for quantification of additional elements developed for this study are also presented. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS for trace element analysis of paints.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号