1.
Glassy carbon electrodes were coated with films of poly(glutamic acid) (PG), and the modified electrode proved to be very effective in the oxidation of caffeic acid. The performance of the film was also tested with ascorbic acid, coumaric acid, ferulic acid, sinapic acid and chlorogenic acid. At pH 5.6, all the hydroxycinnamic acids yield a higher peak current intensity when oxidized after incorporation in the PG-modified electrode, and only the oxidation of ascorbic acid exhibits overpotential reduction. At pH 3.5 only caffeic and chlorogenic acid are incorporated in the modified electrode and exhibit a well-defined oxidation wave at +0.51 V and +0.48 V, which is the base for their determination. Linear calibration graphs were obtained from 9 × 10−6 mol L−1 to 4 × 10−5 mol L−1 caffeic acid by linear voltammetric scan and from 4 × 10−6 mol L−1 to 3 × 10−5 mol L−1 by square wave voltammetric scan. The method was successfully applied to the determination of caffeic acid in red wine samples without interference from other hydroxycinnamic acids or ascorbic acid.  相似文献   

2.
A novel taurine modified glassy carbon electrode was prepared by electropolymerization method. The electrochemical behaviors of epinephrine (EP) and dopamine (DA) at the modified electrode were studied by cyclic voltammetry. The modified electrode exhibited enhanced sensitivity and excellent electrochemical discrimination to DA and EP. The cathodic peaks of the two species were well-separated with a potential difference of about 390 mV, so the poly(taurine) modified electrode was used for simultaneous voltammetric measurement of EP and DA by differential pulse voltammetry. Under the optimum conditions, the cathodic peak currents were linear to concentrations of EP and DA in the range of 2.0 × 10−6 to 6.0 × 10−4 mol L−1 and 1.0 × 10−6 to 8.0 × 10−4 mol L−1, respectively. The detection limits for EP and DA were 3.0 × 10−7 and 1.0 × 10−7 mol L−1, respectively. Because the oxidation of ascorbic acid (AA) is an irreversible reaction at modified electrode, the interference of AA for determining EP and DA was eliminated. The modified electrode has been satisfactorily used for the simultaneous determination of EP and DA in pharmaceutical injections.  相似文献   

3.
Herein, a novel electrochemical method was developed for the determination of tryptophan based on the poly(4-aminobenzoic acid) film modified glassy carbon electrode (GCE). The electrochemical behaviors of tryptophan at the modified electrode were investigated. It was found that the oxidation peak current of tryptophan at the modified GCE was greatly improved compared with that at the bare GCE. The effects of supporting electrolyte, pH value, scan rate, accumulation potential and time were examined. The oxidation peak current of tryptophan was proportional to its concentration over the range from 1.0 × 10−6 to 1.0 × 10−4 mol L−1. The limit of detection was evaluated to be 2.0 × 10−7 mol L−1. The proposed method was sensitive and simple. It was successfully employed to determine tryptophan in pharmaceutical samples.  相似文献   

4.
A poly-amidosulfonic acid and multi-wall carbon nanotubes composite (PASA/MWNTs) modified electrode has been constructed by electropolymerization on glassy carbon electrode (GCE). The electrochemical behaviors of hydroquinone (HQ) and catechol (CC) were investigated using cyclic and differential pulse voltammetries (DPVs) at the prepared electrode. Separation of the reductive peak potentials for HQ and CC was about 120 mV in pH 6.0 phosphate buffer solution (PBS), which makes it suitable for simultaneous determination of these compounds. In the presence of 1.0 × 10−4 mol L−1 isomer, the reductive peak currents of DPV are proportional to the concentration of HQ in the range of 6.0 × 10−6 to 4.0 × 10−4 mol L−1, and to that of CC in the range of 6.0 × 10−6 to 7.0 × 10−4 mol L−1. When simultaneously changing the concentration of both HQ and CC, the linear concentration range of HQ (or CC) is 6.0 × 10−6 to 1.0 × 10−4 mol L−1 (or 6.0 × 10−6 to 1.8 × 10−4 mol L−1), and the corresponding detection limits are 1.0 × 10−6 mol L−1. The proposed method has been applied to simultaneous determination of HQ and catechol in water sample, and the results are satisfactory.  相似文献   

5.
A new approach for decreasing the detection limit for a copper(II) ion-selective electrode (ISE) is presented. The ISE is designed using salicylidine-functionalized polysiloxane in carbon paste. This work describes the attempts to develop the electrode and measurements of its characteristics. The new type of renewable three-dimensional chemically modified electrode could be used in a pH range of 2.3–5.4, and its detection limit is 2.7 × 10−8 mol L−1 (1.2 μg L−1). This sensor exhibits a good Nernstian slope of 29.4 ± 0.5 mV/decade in a wide linear concentration range of 2.3 × 10−7 to 1.0 × 10−3 mol L−1 of Cu(II). It has a short response time (8 s) and noticeably high selectivity over other Cu(II) selective electrodes. Finally, it was satisfactorily used as an indicator electrode in complexometric titration with EDTA and determination of copper(II) in miscellaneous samples such as urine and various water samples.  相似文献   

6.
The insoluble multi-walled carbon nanotubes (MWNT) was successfully dispersed into water in the presence of hydrophobic surfactant. After that, MWNT film-coated glassy carbon electrode (GCE) was achieved via dip-coating and evaporating water. Owing to huge surface area, high sorption capacity and subtle electronic properties, MWNT film exhibits highly efficient accumulation efficiency as well as considerable surface enhancement effects to Sunset Yellow and Tartrazine. As a result, the oxidation peak currents of Sunset Yellow and Tartrazine remarkably increase at the MWNT film-modified GCE. Based on this, a novel electrochemical method was developed for the simultaneous determination of Sunset Yellow and Tartrazine. The limits of detection are 10.0 ng mL−1 (2.2 × 10−8 mol L−1) and 0.1 μg mL−1 (1.88 × 10−7 mol L−1) for Sunset Yellow and Tartrazine. Finally, the proposed method was successfully used to detect Sunset Yellow and Tartrazine in soft drinks.  相似文献   

7.
A simple and highly selective electrochemical method has been developed for the simultaneous determination of hydroquinone (HQ) and catechol (CC) at a glassy carbon electrode covalently modified with penicillamine (Pen). The electrode is used for the simultaneous electrochemical determination of HQ and CC and shows an excellent electrocatalytical effect on the oxidation of HQ and CC upon cyclic voltammetry in acetate buffer solution of pH 5.0. In differential pulse voltammetric measurements, the modified electrode was able to separate the oxidation peak potentials of HQ and CC present in binary mixtures by about 103 mV although the bare electrode gave a single broad response. The determination limit of HQ in the presence of 0.1 mmol L−1 CC was 1.0 × 10−6 mol L−1, and the determination limit of CC in the presence of 0.1 mmol L−1 HQ was 6.0 × 10−7 mol L−1. The method was applied to the simultaneous determination of HQ and CC in a water sample. It is simple and highly selective.  相似文献   

8.
The voltammetric behavior of 4-methylbenzelidene camphor (MBC) was studied by square wave voltammetry (SWV) using mercury electrode. The experimental condition that provided the highest peak current with the best reduction signal definition of MBC was found in Britton-Robinson buffer and cationic surfactants, cetyltrimethylammoniun bromide (CTABr). A single peak of MBC reduction was observed at − 1.21 V versus Ag/AgCl. The developed methodology was applied for determination of MBC in commercial sunscreen SPF 15, 20 and 30 and for the simultaneous determination when other protection agents were associated, such as benzophenone-3 (BENZO) and octyl methoxycinammate (OMC). Both methodologies had shown good determination values for the analyzed samples. The calculated detection limit was 2.99 × 10− 9 mol L− 1 and the quantification limit was 9.98 × 10− 9 mol L− 1.  相似文献   

9.
Quercetin can effectively accumulate at multi-walled carbon nanotubes-paraffin oil paste electrodes (CNTPE) and cause a sensitive anodic peak at around 0.32 V (vs. SCE) in a 0.10 M phosphate buffer solution (pH = 4.0). Under optimized conditions, the anodic peak current is linear to quercetin concentration in the ranges of 2.0 × 10− 9−1.0 × 10− 7 M and 1.0 × 10− 7−2.0 × 10− 5 M, and the regression equations are ip (μA) = 0.0017 + 0.928c (μM, r = 0.999) and ip (μA) = 0.183 + 0.0731c (μM, r = 0.995), respectively. This paste electrode can be regenerated by repetitively cycling in a blank solution for about 2 min. A 1.0 × 10− 6 M quercetin solution is measured for 10 times using the same electrode regenerated after every determination, and the relative standard deviation of the peak current is 1.7%. The method has been applied to the determination of quercetin in hydrolysate product of rutin and the recovery is 99.2–102.6%. In comparison with graphite paste electrode, carbon nanotubes-nujol paste electrode and carbon nanotubes casting film modified glassy carbon electrode, the CNTPE gives higher ratio of signal to background current and better defined voltammetric peak.  相似文献   

10.
A novel hybrid bifunctional sensing platform for simultaneous determination of NO and O2 has been developed, whereby hematite nanotubes are immobilized into the chitosan matrix onto a gold electrode (labeled as HeNTs-Chi/Au). The HeNTs distributed in porous-structured chitosan matrix not only offer abundant active sites for bifunctional sensing of NO and O2, but also facilitate oxidation of NO and reduction of O2 dramatically. Straight calibration curves are achieved in analyte concentration ranges of 5.0 × 10−8 to 1.25 × 10−6 mol L−1 for NO and 2.5 × 10−7 to 6.0 × 10−6 mol L−1 for O2. Also, the detection limits are low of 8.0 × 10−9 mol L−1 for NO and 5.0 × 10−8 mol L−1 for O2. Such an efficient bifunctional sensor for NO and O2 offers great potential in quantitation of NO levels in biological and medical systems, since NO level is highly regulated by various reactive oxygen species.  相似文献   

11.
CuS nanotubes (NTs) made up of nanoparticles were successfully prepared in large quantities in an O/W microemulsion system under low temperature. Based on the characteristics of synchronous fluorescence spectroscopy (SFS), a new method with high sensitivity and selectivity was developed for rapid determination of silver ion with functional copper sulphide (CuS) nanotubes as a fluorescence probe. Under optimal conditions, functional copper sulphide displayed a calibration response for silver ion over a wide concentration range from 1.0 × 10−10 to 1.0 × 10−8 mol L−1. The limit of detection was 0.5 × 10−10 mol L−1 and the relative standard deviation of eight replicate measurements for the highest concentration (1 × 10−8 mol L−1) was 3%. Compared with several fluorescence methods, the proposed method had a wider linear range and improved the sensitivity. Furthermore, the concentration dependence of the synchronous fluorescence intensity is effectively described by a Langmuir-type binding isotherm.  相似文献   

12.
Heterogeneous electrocatalytic reduction of hydrogen peroxide (H2O2) by C60 is reported for the first time. C60 is embedded in tetraoctylammonium bromide (TOAB) film and is characterized by scanning electron microscopy and cyclic voltammetry. Electrocatalytic studies show that the trianion of C60 mediates the electrocatalytic reduction of H2O2 in aqueous solution containing 0.1 M KCl. Application of such film modified electrode as an amperometric sensor for H2O2 determination is also examined. The sensor shows a fast response within 1 s and a linear response is obtained (R = 0.9986) in the concentration range from 3.33 × 10−5 to 2.05 × 10−3 mol L−1 for H2O2, with the detection limit of 2 × 10−5 mol L−1 and the sensitivity of 1.65 μA mM−1. A good repeatability and stability is shown for the sensor during the experiment.  相似文献   

13.
Abbas MN  Radwan AA 《Talanta》2008,74(5):1113-1121
A potentiometric lipoate-selective sensor based on mercuric lipoate ion-pair as a membrane carrier is reported. The electrode was prepared by coating the membrane solution containing PVC, plasticizer, and carrier on the surface of graphite electrode. Influences of the membrane composition, pH, and possible interfering anions were investigated on the response properties of the electrode. The sensor exhibits significantly enhanced response toward lipoate ions over the concentration range 1 × 10−7 mol L−1 to 1 × 10−2 mol L−1 with a lower detection limit of (LDL) of 9 × 10−8 mol L−1 and a slope of −29.4 mV decade−1, with S.D. of the slope is 0.214 mV. Fast and stable response, good reproducibility, long-term stability, applicability over a pH range of 8.0–9.5 is demonstrated. The sensor has a response time of ≤12 s and can be used for at least 6 weeks without any considerable divergence in its potential response. The proposed electrode shows good discrimination of lipoate from several inorganic and organic anions. The CGE was used in flow injection potentiometry (FIP) and resulted in well defined peaks for lipoate ions with stable baseline, excellent reproducibility and reasonable sampling rate of 30 injections per hour. The proposed sensor has been applied for the direct and FI potentiometric determination of LA in pharmaceutical preparations and urine; and has been also utilized as an indicator electrode for the potentiometric titration of LA.  相似文献   

14.
A new sensitive adsorptive voltammetric procedure is described for trace measurement of thorium. It is based on the cathodic stripping peak of the thorium–alizarin complexon (ALC) complex at a carbon paste electrode (CPE). The complex of Th(IV) with alizarin is adsorbed at a CPE in a mixed buffer solution (pH 5.0) which consists of 0.1mol·L–1 sodium acetate and 0.04mol·L–1 potassium biphthalate, yielding a sensitive cathodic voltammetric peak corresponding to the reduction of alizarin in the complex at –0.57V (vs. SCE). The second-order derivative peak current of the complex is linearly dependent upon the concentration of Th(IV) over the range of 3.0×10–9 8.0×10–7mol·L–1. The detection limit is 1.0×10–9mol·L–1 for 180s accumulation. The molar ratio of each component in the complex was estimated as nTh(IV):nALC=1:1 by a continuous variation method. The electrode processes of the Th(IV)–alizarin complex at a CPE were investigated. The procedure was successfully applied to the trace determination of thorium in ore and clay samples.  相似文献   

15.
柴春彦  徐明刚  刘国艳 《分析化学》2006,34(12):1715-1719
为探索用电化学方法检测生物样品中氯霉素残留的高灵敏度技术,本实验研究了阳离子表面活性剂十六烷基三甲基溴化铵(CTMAB)对氯霉素在玻碳电极上伏安行为的影响,实验结果表明,以0.02 mol/L高氯酸为支持电解质,在0.40~-0.60 V的范围内进行伏安扫描时,2×10-5mol/L CTMAB能显著提高氯霉素在-0.41 V处的还原峰电流。利用这种改进的电化学方法检测氯霉素的线性范围为0.0026~8 mg/L,检出限达到0.83μg/L。研究了缓冲液种类及其酸碱度及其它表面离子活性剂等对测试氯霉素的影响。  相似文献   

16.
A sensitive voltammetric method has been developed for the determination of total or single species of sulfur anions containing sulfide, sulfite and thiosulfate. The method is based on the catalytic effect of tris(2,2'-bipyridyl)Ruthenium(II) (Ru(bpy)2+ 2) as a homogeneous mediator on the oxidation of those anions at the surface of a glassy carbon electrode. A reversible redox couple of Ru(II)/Ru(III) were observed as a solute in aqueous solution. Cyclic voltammetry study showed that the catalytic current of the system depends on the concentration of the anions. Optimum pH values for voltammetric determination of sulfite, thiosulfate and sulfide has been found to be 5.6, 10.0 and 10.0, respectively. Under the optimized conditions the calibration curves have been obtained linear in the concentration ranges of 0.8–500.0, 0.4–1000.0 and 0.5–5000.0 µmol L− 1 of SO32−, S2O32− and S2−, respectively. The detection limits have been calculated to be 0.40, 0.17 and 0.33 µmol L− 1 for SO32−, S2O32− and S2−, respectively. The diffusion coefficients of sulfite and thiosulfate have been estimated using chronoamperometry. The chronoamperometric method also has been used to determine the catalytic rate constant for catalytic reaction of the Ru(bpy)2+ 2 with sulfite and thiosulfate. Finally the proposed method has been used for the determination of total sulfur contents in real samples of water and wastewater. Moreover the sulfite content in sugar and sulfur dioxide in air has been determined with satisfactory results.  相似文献   

17.
A novel voltammetric sensor, based on single-walled carbon nanotubes (SWNT) dispersed in Nafion and modified glassy carbon electrode (GCE), was fabricated and used to determine the trace amounts of dihydromyricetin (DMY). The electrochemical behavior of DMY at this sensor was investigated in 0.1 mol L−1 sulfuric acid solutions + 0.1 mol L−1 NaCl by cyclic voltammetry and squarewave voltammetry. Compared with bare GCE, the electrode presented an excellent response of DMY through an adsorption-controlled quasi-reversible process. Under the optimum conditions, the response peak currents were linear relationship with the DMY concentrations in the range of 1.0 × 10−7–1.0 × 10−5 mol L−1 with a detection limit of 9 × 10−8 mol L−1. Based on this voltammetric sensor, a simple and sensitive electroanalytical method for DMY was proposed and applied to quantitative determination of DMY in Ampelopsis grossedentata samples. In addition, the oxidation mechanism was proposed and discussed, which could be a reference for the pharmacological action of DMY in clinical study.  相似文献   

18.
A mesoporous TiO2 was synthesized according to the reported method, and then used to modify the carbon paste electrode (CPE). The electrochemical behavior of hypoxanthine was investigated with great detail. Compared with the unmodified CPE, the mesoporous TiO2-modified CPE greatly enhances the oxidation signal of hypoxanthine. Due to huge surface area, well-defined and special mesopores, the mesoporous TiO2-modified CPE shows considerable enhancement effect toward hypoxanthine. Based on this, a sensitive, rapid and convenient electrochemical method was developed for the determination of hypoxanthine. The linear range is over the range from 2.0 × 10−7 to 5.0 × 10−5 mol L−1, and the limit of detection is estimated to be 5.0 × 10−8 mol L−1. The relative standard deviation (RSD) for 10 mesoporous TiO2-modified CPEs is 5.7%. Finally, this sensing method was successfully used to determine hypoxanthine in human blood serum samples.  相似文献   

19.
The electrochemical behavior of L-tyrosine was investigated at a multi-wall carbon nanotubes modified glassy carbon electrode. L-tyrosine itself showed a poor electrochemical response at the bare glassy carbon electrode; however, a multi-wall carbon nanotubes film fabricated on the glassy carbon electrode can directly enhance the electrochemical signal of L-tyrosine when applying cyclic voltammetry and square wave stripping voltammetry without any mediator. Cyclic voltammetry was carried out to study the electrochemical oxidation mechanism of L-tyrosine, which shows a totally irreversible process and an oxidation potential of 671 mV at the modified electrode and 728 mV at the bare electrode, ΔEp = 57 mV. The anodic peak current linearly increases with the square root of scan rate in the low range, suggesting that the oxidation of L-tyrosine on the multi-wall carbon nanotubes modified electrode is a diffusion-controlled process. The square wave stripping voltammetry currents of L-tyrosine at the multi-wall carbon nanotubes modified electrodes increased linearly with the concentration in the range of 2.0 × 10−6–5.0 × 10−4 mol L−1. The detection limit was 4.0 × 10−7 mol L−1. The method is simple, quick, sensitive and accurate.  相似文献   

20.
This paper reports a poly-Nile Blue (PNB) sensing film based electrochemical sensor and the application in food analysis as a possible alternative for electrochemical detection of nitrite. The PNB-modified electrode in the sensor was prepared by in situ electropolymerization of Nile Blue at a prepolarized glassy carbon (GC) electrode and then characterized by cyclic voltammetry (CV) and pulse voltammetry in phosphate buffer (pH 7.1). Several key operational parameters affecting the electrochemical response of PNB sensing film were examined and optimized, such as polarization time, PNB film thickness and electrolyte pH values. As the electroactive PNB sensing film provides plenty of active sites for anodic oxidation of nitrite, the nitrite sensor exhibited high performance including high sensitivity, low detection limit, simple operation and good stability at the optimized conditions. The nitrite sensor revealed good linear behavior in the concentration range from 5.0 × 10−7 mol L−1 to 1.0 × 10−4 mol L−1 for the quantitative analysis of nitrite anion with a limit of detection of 1.0 × 10−7 mol L−1. Finally, the application in food analysis using sausage as testing samples was investigated and the results were consistent with those obtained by standard spectrophotometric method.  相似文献   