首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Goswami A  Singh AK  Venkataramani B 《Talanta》2003,60(6):1141-1154
The silica gel modified with (3-aminopropyl-triethoxysilane) was reacted with 5-formyl-8-hydroxyquinoline (FHOQx) to anchor 8-quinolinol ligand on the silica gel. It was characterised with cross polarisation magic angle spinning (CPMAS) NMR and diffuse reflectance infrared Fourier transformation (DRIFT) spectroscopy and used for the preconcentration of Cu(II), Pb(II), Ni(II), Fe(III), Cd(II), Zn(II) and Co(II) prior to their determination by flame atomic absorption spectrometry. The surface area of the modified silica gel has been found to be 227 m2 g−1 and the two pKa values as 3.8 and 8.0. The optimum pH ranges for quantitative sorption are 4.0–7.0, 4.5–7.0, 3.0–6.0, 5.0–8.0, 5.0–8.0, 5.0–8.0 and 4.0–7.0 for Cu, Pb, Fe, Zn, Co, Ni and Cd, respectively. All the metals can be desorbed with 2.5 mol l−1 HCl or HNO3. The sorption capacity for these metal ions is in range of 92–448.0 μmol g−1 and follows the order Cd3, NaCl, NaBr, Na2SO4 and Na3PO4, glycine, sodium citrate, EDTA, humic acid and cations Ca(II), Mg(II), Mn(II) and Cr(III) in the sorption of all the seven metal ions are reported. The preconcentration factors are 150, 250, 200, 300, 250, 300 and 200 for Cd, Co, Zn, Cu, Pb, Fe and Ni, respectively and t1/2 values <1 min except for Ni. The 95% extraction by batch method takes ≤25 min. The simultaneous enrichment and determination of all the metals are possible if the total load of the metal ions is less than sorption capacity. In river water samples all these metal ions were enriched with the present ligand anchored silica gel and determined with flame atomic absorption spectrometer (R.S.D.≤6.4%). Cobalt contents of pharmaceutical samples (vitamin tablet) were preconcentrated with the present chelating silica gel and estimated by flame AAS, with R.S.D.1.4%. The results are in the good agreement with the certified value, 1.99 μg g−1 of the tablets. Iron and copper in certified reference materials (synthetic) SLRS-4 and SLEW-3 have been enriched with the modified silica gel and estimated with R.S.D.<5%.  相似文献   

2.
Pyrocatechol is immobilized on cellulose via ---NH---CH2---CH2---NH---SO2---C6H4---N=N--- linker and the resulting macromolecular chelator characterized by IR, TGA, CPMAS 13C NMR and elemental analyses. It has been used for enrichment of Cu(II), Zn(II), Fe(III), Ni(II), Co(II), Cd(II) and Pb(II) prior to their determination by flame atomic absorption spectrometry (FAAS). The pH ranges for quantitative sorption (98.0–99.4%) are 4.0–7.0, 5.0–6.0, 3.0–4.0, 5.0–7.0, 5.0–8.0, 7.0–8.0 and 4.0–5.0, respectively. The desorption was found quantitative with 0.5 mol dm−3 HCl/HNO3 (for Pb). The sorption capacity of the matrix for the seven metal ions has been found in the range 85.3–186.2 μmol g−1. The optimum flow rate of metal ion solution for quantitative sorption of metal onto pyrocatechol functionalized cellulose as determined by column method, is 2–6 cm3 min−1, whereas for desorption it is 2–4 cm3 min−1. The tolerance limits for NaCl, NaBr, NaI, NaNO3, Na2SO4, Na3PO4, humic acid, EDTA, ascorbic acid, citric acid, sodium tartrate, Ca(II) and Mg(II) in the sorption of all the seven metal ions are reported. Ascorbic acid is tolerable up to 0.8 mmol dm−3 with Cu and Pb where as sodium tartrate does not interfere up to 0.6 mmol dm−3 with Pb. There is no interference of NaBr, NaCl and NaNO3 up to a concentration of 0.5 mol dm−3, in the sorption of Cu(II), Cd(II) and Fe(III) on to the chelating cellulose matrix The preconcentration factors are between 75 and 300 and t1/2 values ≤5 min for all the metal ions. Simultaneous sorption of Cu, Zn, Ni and Co is possible at pH 5.0 if their total concentration does not exceed lowest sorption capacity. The present matrix coupled with FAAS has been used to enrich and determine the seven metal ions in river and tap water samples (relative standard deviation (R.S.D.) 1.05–7.20%) and synthetic certified water sample SLRS-4 (NRC, Canada) with R.S.D. 2.03%. The cobalt present in pharmaceutical vitamin tablets was also preconcentrated on the modified cellulose and determined by FAAS (R.S.D. 1.87%).  相似文献   

3.
The profiles of the parallel and perpendicular bands ν6 and ν10 of allene in CS2 and their temperature dependence have been studied. These profiles are sensibly lorentzian and consequently allow us to derive the components D and D of the rotational diffusion tensor and the corresponding activation energies; the accuracy of the results is discussed. In particular, it is not possible to determine unambiguously whether the activation energies U| and U are equal or different but, whichever the case, the ratio D/D is of the order of 10. An application test of the extended J rotational diffusion model shows that the results concurrently obtained for the ν6 and ν10 bands are incompatible with this model and we come to the conclusion that the rotation of allene about its various axes is anisotropic.  相似文献   

4.
Rodriguez AM  de Torres AG  Pavon JM  Ojeda CB 《Talanta》1993,40(12):1861-1866
A method for the simultaneous spectrophotometric determination of cadmium, copper and zinc based on the formation of their complexes with 1,5-bis(di-2-pyridylmethylene)thiocarbonohydrazide is proposed. The absorption curves of these complexes overlap severely in the scanning range 380–480 nm. The analyte concentrations are calculated by a least squares fit of the pure spectra to the mixture spectra. A linear determination range of 0.1–1.7 μg/ml for cadmium, 0.1–1.3 μg/ml for copper and 0.2–1.2 μg/ml for zinc were obtained. The effect of interference was studied. The method has been applied to the determination of these metal ions in various type of materials.  相似文献   

5.
建立了一种微波消解前处理技术的半消解法消解样品,采用原子吸收光谱法和原子荧光光谱法同时测定土壤中主要重金属元素铜、锌、镉、砷、汞的方法,检测土壤标准物质GSS-3、GSS-5、GSS-20,结果显示测定均值在标准差允许范围内,相对标准偏差小于8.5%(n=4),是土壤重金属元素快速检测的可选方法。  相似文献   

6.
A method is proposed for determination of lanthanum, cerium, praseodymium, neodymium, and samarium in mineral water by means of total-reflection X-ray fluorescence analysis. In this work, the combined technique of preconcentration of rare earth ions is used. This technique consists of coprecipitation of metal hydroxides on the collector (iron (III) hydroxide) and dispersive liquid–liquid microextraction of their complexes with 1-(2-pyridylazo)-2-naphthol by chloroform in the presence of ethanol. The use of the developed hybrid approach allows simultaneous determination of the mentioned metals in mineral water in the range n(10–2–101) μg/L. The results of analysis of Arkhyz and Rychal-Su mineral waters by the proposed extraction–X-ray fluorescent method are confirmed by the literature data, obtained by inductively coupled plasma mass spectrometry.  相似文献   

7.
Li J  Zhang Y  Cai W  Shao X 《Talanta》2011,84(3):679-683
Analysis of metal ions in environment is of great importance for evaluating the risk of heavy metal to public health and ecological safety. A method for simultaneous determination of metal ions in water samples was developed by using adsorption preconcentration and near-infrared diffuse reflectance spectroscopy (NIRDRS). A high capacity adsorbent of thiol-functionalized magnesium phyllosilicate, named Mg-MTMS, was prepared by co-condensation for preconcentration of Hg2+, Pb2+ and Cd2+ in aqueous solutions. After adsorbing the analytes onto the adsorbent, NIRDRS was measured and PLS models were established for fast and simultaneous quantitative prediction. Because the interaction of the ions with the functional group of the adsorbent can be reflected in the spectra, the models built with the samples prepared by river water were proven to be efficient enough for precise prediction. The determination coefficients (R2) of the validation samples for the three ions were found as high as 0.9197, 0.9599 and 0.9861, respectively. Furthermore, because the high adsorption efficiency of Mg-MTMS, the detected concentrations are as low as milligrams per liter for the three ions, and the concentration can be further reduced. Therefore, the feasibility of quantitative analysis metal ions in river water by NIRDRS is proven and this may provide a new way for fast simultaneous determination of trace metals in environmental waters.  相似文献   

8.
Kumar M  Rathore DP  Singh AK 《Talanta》2000,51(6):1187-1196
A stable chelating resin matrix was synthesized by covalently linking o-aminophenol (o-AP) with the benzene ring of the polystyrene–divinylbenzene resin, Amberlite XAD-2, through a –N=N– group. Elemental analyses, thermogravimetric analysis (TGA) and infrared spectra have characterized the resulting chelating resin. It has been used to preconcentrate Cu2+, Cd2+, Co2+, Ni2+, Zn2+ and Pb2+, prior to their determination by flame atomic absorption spectrometry. The optimum pH values for quantitative sorption of Cu, Cd, Co, Ni, Zn and Pb are 6.2–7.4, 5.6–7.2, 5.6–9.0, 6.0–9.0, 5.7–7.0 and 5.0–6.0, respectively. These metals are desorbed (recovery 91–98%) with 4 mol dm−3 HNO3. The sorption capacity of the resin is 3.37, 3.42, 3.29, 3.24, 2.94 and 3.32 mg of metal g−1 of resin, respectively, for Cu, Cd, Co, Ni, Zn and Pb. The effect of NaF, NaCl, NaNO3, Na2SO4, and Na3PO4 on the sorption of these metal ions has been investigated. These electrolytes are tolerable up to 0.01 mol dm−3 in case of all the metal ions, except Cl which is tolerable even up to 0.1 mol dm−3 for Zn and 1.0 mol dm−3 for Pb. The preconcentration factor for Cu, Cd, Co, Ni, Zn and Pb are 50, 50, 100, 65, 40 and 40 (concentration level 10–25 μg dm−3) respectively. Simultaneous enrichment of the six metals is possible. The method has been applied to determine Cu, Cd, Co, Ni, Zn and Pb content in well water samples (RSD≤8%).  相似文献   

9.
The potential of the continuous addition of reagent technique in differential reaction-rate methods was evaluated. The approach was tested on the simultaneous determination of copper and iron through their fast complex-formation reaction with pyridoxal thiosemicarbazone. Mixtures of these metal ions at the sub-μg ml?1 level with copper/iron ratios from 5:1 to 1:2 can be analysed with a precision (relative standard deviation) of 0.25 and 0.45%, respectively. The method was successfully applied to the determination of both metals in serum samples with a purpose-designed reaction mini-chamber.  相似文献   

10.
Amberlite XAD-2 has been functionalized by coupling it, through the ---N=N--- group, with Pyrocatechol Violet (PV), and the resulting resin has been characterized by elemental analysis, thermogravimetric analysis (TGA) and IR spectra. The resin has been used for preconcentrating Zn(II), Cd(II), Pb(II) and Ni(II) ions prior to their determination by flame atomic absorption spectrometry. The optimum pH values for quantitative sorption are 5, 5–7, 4, and 3 for Zn, Cd, Pb and Ni, respectively. The four metals can be desorbed (recovery ˜98%) with 4 M HNO3; also, 4 M HCl is equally suitable except for Zn. The sorption capacity of the resin is 1410, 1270, 620 and 1360 μg g−1 resin for Zn, Cd, Ni and Pb, respectively. The effect of F, Cl, NO3, SO42− and PO43− on the sorption of these four metal ions has been investigated. They are tolerable in the range 0.01–0.20 M, for Pb. In the sorption of Zn(II) and Ni(II), the tolerance limits of all these ions are upto 0.01 M, whereas for Cd(II), F, NO3, and PO43− have been found to be tolerable upto 0.50, 0.10 and 0.10 M, respectively. The preconcentration factors are 60, 50, 23 and 18 for Zn, Cd, Pb and Ni, respectively. Simultaneous collection and determination of the four metals are possible. Cations commonly present in drinking water do not affect the sorption of either metal ion if present at a concentration level similar to that of water. The method has been applied to determine Zn, Ni and Pb content of well-water samples (RSD ≤9%).  相似文献   

11.
Narin I  Soylak M  Elçi L  Doğan M 《Talanta》2000,52(6):1041-1046
A simple preconcentration method is described for the determination of Cu, Mn, Co, Cd, Pb, Ni and Cr in water samples by flame AAS. Trace metal ions in water were sorbed as pyrocatechol violet complexes on activated carbon column at the pH range of 4–8, then eluted with 1 M HNO3 in acetone. The effect of major cations and anions of the natural water samples on the sorption of metal ions has been also investigated. The concentration of the metal ions detected after preconcentration was in agreement with the added amount. The present method was found to be applicable to the preconcentration of Cu, Mn, Co, Cd, Pb, Ni and Cr in natural water samples with good results such as R.S.D. from 3 to 8% (N=10) and detection limits under 70 ng l−1.  相似文献   

12.
EPR lineshape simulation studies have been performed on a specimen of 80MoO3–20B2O3 glass in the temperature range of 300–77 K. The values of the obtained spin Hamiltonian parameters are: g=1.940, g=1.974, A=150.0×10−4 cm−1, A=35.6×10−4 cm−1 and g=1.935, g=1.975, A=141.9×10−4 cm−1, A=34.5×10−4 cm−1 at 300 and 77 K, respectively. The paramagnetic site in the specimen is molybdenyl, MoO3+, ion in which the Mo is in a distorted octahedral environment of six oxygen atoms with C4v symmetry. The 11-parallel and 11-perpendicular line feature of the EPR lineshape shows that two Mo nuclei are magnetically equivalent in the glassy matrix, in the temperature range 300–77 K.  相似文献   

13.
A coupling sensitive solid phase spectrophotometric (SPS) procedure for determination of traces of heavy metals (Me-SPS) and multicomponent analysis by multiple linear regressions (MA), a simple methodology for simultaneous determination of metals in mixtures was inaugurated. The Me-SPS procedure is based on sorption of heavy metals on PAN-resin and direct absorbance measurements of colour product Me-PAN sorbed on a solid carrier in a 1-mm cell. This methodology (Me-SPS-MA) was checked by simultaneous determination of metals in synthetic mixtures with different compositions and contents of metals important in pharmaceutical practice: Zn, Pb, Cd, Cu, Co, and Ni. Good agreement between experimental and theoretical amounts of heavy metals is obtained from the recovery test (78.3–110.0%). The proposed method enables determination of particular metal ion at the ng mL−1 level and it was successfully applied to the determination impurities from heavy metal traces in pharmaceutical substances (Cu in ascorbic acid, Pb in glucose, and Zn in insulin). The proposed procedure could be possible contribution to the development of pharmacopoeial methodology for a heavy metals test.  相似文献   

14.
A simple method for the determination of trace concentrations of metals in saline water is described. The analytical procedure involves the separation of metal ions of Cu, Zn, Hg and Fe by precipitation with diethyldithiocarbamate (DDTC). The radioisotope X-ray fluorescence method using Si(Li) detector has been applied for the determination of metal ions closed in the DDTC deposition.  相似文献   

15.
The H-point standard addition method (HPSAM) for simultaneous determination of Fe(II) and Fe(III) is described. The method is based on the difference in the rate of complex formation of iron in two different oxidation states with Gallic acid (GA) at pH 5. Fe(II) and Fe(III) can be determined in the range of 0.02–4.50 μg ml−1 and 0.05–5.00 μg ml−1, respectively, with satisfactory accuracy and precision in the presence of other metal ions, which rapidly form complexes with GA under working conditions. The proposed method was successfully applied for simultaneous determination of Fe(II) and Fe(III) in several environmental and synthetic samples with different concentration ratios of Fe(II) and Fe(III).  相似文献   

16.
Rosi Ketrin Katarina 《Talanta》2009,78(3):1043-990
On-line preconcentration and determination of transition and rare-earth metals in water samples was performed using a Multi-Auto-Pret system coupled with inductively coupled plasma-atomic emission spectrometry (ICP-AES). The Multi-Auto-Pret AES system proposed here consists of three Auto-Pret systems with mini-columns that can be used for the preconcentration of trace metals sequentially or simultaneously, and can reduce analysis time to one-third and running cost of argon gas and labor. A newly synthesized chelating resin, ethylenediamine-N,N,N′-triacetate-type chitosan (EDTriA-type chitosan), was employed in the Multi-Auto-Pret system for the collection of trace metals prior to their measurement by ICP-AES. The proposed resin showed very good adsorption ability for transition and rare-earth metal ions without any interference from alkali and alkaline-earth metal ions in an acidic media. For the best result, pH 5 was adopted for the collection of metal ions. Only 5 mL of samples could be used for the determination of transition metals, while 20 mL of samples was necessary for the determination of rare-earth metals. Metal ions adsorbed on the resin were eluted using 1.5 M nitric acid, and were measured by ICP-AES. The proposed method was evaluated by the analysis of SLRS-4 river water reference materials for trace metals. Good agreement with certified and reference values was obtained for most of the metals examined; it indicates that the proposed method using the newly synthesized resin could be favorably used for the determination of transition and rare-earth metals in water samples by ICP-AES.  相似文献   

17.
Preconcentration and determination of trace elements in seawater by chelation ion chromatography (CIC) was studied. For the retention of metal ions (0.25–0.30 M), ammonium acetate (at pH 4.8–5.1) and macroporous iminodiacetate chelating resin were used. This system (CIC) permits trace and ultra-trace determination of metals in a variety of complex matrices, in particular those with a high content of alkali and alkaline earth metals. Detection limits range from 0.1 to 0.5 ng. Satisfactory results are obtained in the range 0.05–0.5 μg/1 when 60 ml of sample are preconcentrated. In this work the contents of zinc, copper, nickel, cobalt and manganese in seawater from the Venice lagoon are presented. The results obtained by chelation ion chromatography are compared with those obtained using preconcentration of metals with dithizone and ammonium pyrrolidinedithiocarbamate in chloroform and analysed by graphite furnace atomic absorption spectrometry.  相似文献   

18.
在水热条件下, 利用锌离子与2种有机配体合成出1个结构新颖的金属有机骨架化合物[Zn2(BPDC)(IN)2](H2BPDC=4,4'-联苯二羧酸; HIN=异烟酸), 并通过单晶X射线衍射、 红外光谱、 热重分析和荧光光谱等对该化合物进行了表征. 结果表明, 该化合物结构中Zn离子与BPDC的羧基形成双核金属次级结构单元[Zn2(—CO2)2(IN)2], 相邻次级结构单元通过IN配离子连接形成[Zn2(—CO2)2(IN)2]二维层面, 相邻的二维层通过BPDC相互连接形成具有三重互穿的简单格子拓扑结构. 该化合物表现出良好的荧光性质.  相似文献   

19.
An improved method to prepare alkylamine-stabilized Pt and Ru nanoparticles based on the original Brust’s procedure [J. Chem. Soc., Chem. Commun. (1994) 801] has been developed. The new method involves, firstly, mixing an aqueous solution of metal salts such as PtCl62−, PtCl42− or Ru3+ with an ethanol solution of dodecylamine; extracting the metal ions into a toluene layer; and finally reducing the metal ions to their zero valent states using NaBH4. Alkylamine-stabilized Pt nanoparticles prepared this way had a polyhedral or wormlike appearance, depending closely on the chemical nature of the metal precursor salts being used. On the contrary, dodecylamine-stabilized ruthenium nanoparticles were predominantly spherical. The particle formation and growth processes in the hydrocarbon layer could be influenced by the different ways dodecylamine was bound to H2PtCl6, K2PtCl4 or RuCl3 at the precursor stage.  相似文献   

20.
The application of ion-induced x-rays to spectrochemical analysis was examined by means of a dispersive method with a flat crystal and a 200-kV ion accelerator. For x-rays of longer wavelength than 10 Å, x-ray count rates of the order of 104–105 c.p.s. were obtained; the use of heavy ions such as Kr+, Ne+ and O+ was shown to be effective for x-rays shorter than about 30 Å, while protons were more efficient for longer wavelengths. X-Ray excitation efficiencies are almost independent of the atomic shell with which the x-rays are associated and are dependent on wavelength only, indicating that almost all elements can yield K, L or M x-rays of considerable intensity. The x-ray excitation method by proton and heavy ion bombardment was applied to the determination of some light elements, F, O, N and Be. Detection limits of 10 p.p.m. could be readily achieved for these elements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号