首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sulfur reference solution at the 1 mg kg−1 level, NMIJ CRM 4215-a, has been issued by the National Metrology Institute of Japan at the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The intended use of this CRM is for the calibration of standards used in the determination of sulfur in liquid fuels. The certified value of this CRM was determined using the gravimetric blending method. Thiophene and toluene were chosen as the high purity sulfur compound and the dilution solvent, respectively. Measurements of the trace sulfur in the solvent were performed using the total sulfur analyzer with an enrichment system; the standard addition method was employed. When trace sulfur in the solvent was evaluated, the signal which appears with no sample injection was subtracted as the background.  相似文献   

2.
Arsenate [As(V)] solution reference material, National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 7912-a, for speciation of arsenic species was developed and certified by NMIJ, the National Institute of Advanced Industrial Science and Technology. High-purity As2O3 reagent powder was dissolved in 0.8 M HNO3 solution and As(III) was oxidized to As(V) with HNO3 to prepare 100 mg kg-1 of As(V) candidate CRM solution. The solution was bottled in 400 bottles (50 mL each). The concentration of As(V) was determined by four independent analytical techniques—inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, graphite furnace atomic absorption spectrometry, and liquid chromatography inductively coupled plasma mass spectrometry—according to As(V) calibration solutions, which were prepared from the arsenic standard of the Japan Calibration Service system and whose species was guaranteed to be As(V) by NMIJ. The uncertainties of all the measurements and preparation procedures were evaluated. The certified value of As(V) in the CRM is (99.53 ± 1.67) mg kg-1 (k = 2).  相似文献   

3.
An arsenobetaine [(CH3)3As+CH2COO] solution reference material, NMIJ CRM 7901-a, intended for use in the speciation of arsenic compounds, was developed and certified by the National Metrology Institute of Japan (NMIJ), part of the National Institute of Advanced Industrial Science and Technology (AIST). The high-purity arsenobetaine powder was synthesized from trimethylarsine [(CH3)3As], and it was dissolved in water in order to prepare 20 mg kg−1 of arsenobetaine standard solution. The solution was bottled in 500 bottles (each containing 10 ml). Certification of the CRM for arsenobetaine was conducted by NMIJ. The concentration of As was determined by four independent analytical techniques (ICP–MS, ICP–OES, GFAAS and LC–ICP–MS), and each result was converted to the arsenobetaine concentration by applying an appropriate factor. The arsenobetaine concentration in the CRM was thus certified.  相似文献   

4.
The National Metrology Institute of Japan has issued a certified reference material of biodiesel fuel derived from palm oil (NMIJ CRM 8302-a) for the measurement and quality control of water, methanol, six elements (sulfur, phosphorus, sodium, potassium, magnesium, and calcium), density, and kinematic viscosity. This paper presents the technical details for the characterization of the water content in NMIJ CRM 8302-a. Because the water content in biodiesel is easily affected by ambient humidity, sample handling is extremely difficult. Thus, a sample handling technique that overcomes this limitation was established, and optimized coulometric and volumetric Karl Fischer titrations were performed in order to accurately determine the water content with traceability to the International System of Units. The certified water content and its expanded uncertainty with a coverage factor k = 2 were 393 mg kg?1 and 25 mg kg?1, respectively.  相似文献   

5.
A certified reference material (CRM) for the determination of perfluorooctanoic acid (PFOA) has been issued as NMIJ CRM 4056-a by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Purity (kg kg?1) based on a titration method was determined by subtracting the mass fractions of impurities measured using liquid chromatography/mass spectrometry (LC/MS) from those of acids expressed as PFOA measured by a neutralization potentiometric titration. To validate an obtained result, purity based on a mass balance method was determined by subtracting the mass fractions of impurities, measured using LC/MS, Karl-Fischer titration (KFT), and vacuum evaporation, from 1 kg kg?1. Results from both titration and mass balance methods were in agreement within the accepted limits of uncertainty. The certified purity of NMIJ CRM 4056-a was determined to be 0.959 kg kg?1, calculated as the mean of the results obtained with the two methods. The standard uncertainty of the certified purity was evaluated from purity evaluations as well as from sample homogeneity and stability obtained from LC/MS and KFT analyses. Consequently, the expanded uncertainty was estimated to be 0.005 kg kg?1 with a coverage factor of k = 2.  相似文献   

6.
A new calibration solution reference material for the determination of perfluorooctane sulfonate anion (PFOS) and its salts has been issued as a certified reference material (CRM) by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The purity amount-of-substance fraction of raw material potassium perfluorooctane sulfonate (K-PFOS) was evaluated based on the results obtained using the freezing point depression method, and the purity mass fraction of the raw material was calculated using the average molar mass of impurities, the molar mass of K-PFOS, and the purity amount-of-substance fraction. The certified concentration of this CRM was obtained by multiplying the dilution ratio of the raw material in a prepared solution (methanol) determined from the gravimetric blending method by the purity of the raw material. The preparation concentration of K-PFOS as a certified value of NMIJ CRM 4220-a was determined to be 9.93?mg?kg?1. In addition, the standard uncertainty of the certified value was evaluated from the purity evaluation as well as from sample inhomogeneity, instability, and preparation variation obtained from LC/MS measurements of different gravimetrically prepared solutions of the NMIJ CRM. Consequently, the expanded uncertainty was estimated to be 0.15?mg?kg?1 with a coverage factor k?=?2 corresponding to the half-width of estimated confidence interval of approximately 95%.  相似文献   

7.
Prompt gamma activation analysis using a focused thermal neutron guided beam at JAEA JRR-3M was applied to the determination of B in ceramic certified reference materials (BAM CRM S-003 Silicon Carbide Powder and NMIJ CRM 8004-a Silicon Nitride Powder). Cl and Si were used as internal standards to obtain linear calibration curves of B. The analytical result of B in BAM CRM S-003 was in good agreement with the certified value. The relative expanded measurement uncertainties (k = 2) were 4.8% for BAM CRM S-003 and 4.9% for NMIJ CRM 8004-a.  相似文献   

8.
A certified reference material (CRM) for the determination of perfluorooctane sulfonate (PFOS) in acrylonitrile-butadiene-styrene (ABS) resin (NMIJ CRM 8155-a) has been issued by the National Metrology Institute of Japan (NMIJ). The bulk material was prepared by mixing commercial ABS resin powder and potassium PFOS and cut into square plates (20 × 20 mm, 2 mm thick) as the CRM. Analytical processes combined with isotope-dilution mass spectrometry and liquid chromatography/mass spectrometry were optimised and applied for characterisation. One of the approaches adopted by NMIJ for certification is that results from two or more primary methods of measurement should be used; thus, two optimised isotope-dilution mass spectrometric methods (Methods 1 and 2 with reprecipitation and with reprecipitation/solid phase extraction, respectively, were validated mutually and employed) were used to determine the certified value. Homogeneity and stability of the square plates were evaluated and their uncertainty contributions (as relative standard uncertainties) were 1.43% for inhomogeneity and 6.96% for approximately two years’ instability. The certified mass fraction of linear PFOS (heptadecafluoro-1-octanesulfonic acid) in the CRM with expanded uncertainty (coverage factor k = 2, approximately 95% confidence interval) was (33.1 ± 5.0) mg kg?1 as free acid of PFOS.  相似文献   

9.
A new marine sediment reference material (NMIJ CRM 7301-a) for butyltins analysis was prepared and certified by the National Metrological Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The original material of the sediment was collected at a bay near industrial activities in Japan. The sediment material was air-dried, sieved, homogenized, and packaged into 1,000 glass bottles (60 g each). Certification of NMIJ CRM 7301-a was carried out at NMIJ using two different types of species-specific isotope dilution mass spectrometry: isotope dilution–ethylation–gas chromatography/inductively coupled plasma mass spectrometry (GC/ICPMS) and isotope dilution–ethylation–gas chromatography/mass spectrometry (GC/MS). A mixture of 118Sn-enriched monobutyltin, dibutyltin, and tributyltin was synthesized in our laboratory and was used as a spike for both techniques. Certified values are given for tributyltin (0.044±0.004 mg kg–1 as Sn), dibutyltin (0.056±0.006 mg kg–1 as Sn, and monobutyltin (0.058±0.013 mg kg–1 as Sn), being at lower levels than currently available sediment CRMs for the analysis of organotins.  相似文献   

10.
A certified reference material, NMIJ CRM 7405-a, for the determination of trace elements and As(V) in algae was developed from the edible marine hijiki (Hizikia fusiforme) and certified by the National Metrology Institute of Japan (NMIJ), the National Institute of Advanced Industrial Science and Technology (AIST). Hijiki was collected from the Pacific coast in the Kanto area of Japan, and was washed, dried, powdered, and homogenized. The hijiki powder was placed in 400 bottles (ca. 20 g each). The concentrations of 18 trace elements and As(V) were determined by two to four independent analytical techniques, including (ID)ICP-(HR)MS, ICP-OES, GFAAS, and HPLC-ICP-MS using calibration solutions prepared from the elemental standard solution of Japan calibration service system (JCSS) and the NMIJ CRM As(V) solution, and whose concentrations are certified and SI traceable. The uncertainties of all the measurements and preparation procedures were evaluated. The values of 18 trace elements and As(V) in the CRM were certified with uncertainty (k = 2).  相似文献   

11.
A method is described for quantification of sulfur at low concentrations on the order of mg kg−1 in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at 32S and 34S related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg−1 S and 2.5 mg kg−1 S (in the sample). The LOD was constrained by instrument background counts at 32S but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 ± 0.13 mg kg−1. No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy.  相似文献   

12.
Reference materials for quantitative determination of Cd, Cr, Hg and Pb in polycarbonate were developed. Reference materials with two concentration level of elements were prepared by adding appropriate amounts of chemicals to a blank polycarbonate base material. It was shown that ten bottles with triplicate analysis are enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for four weeks and long-term stability test for twelve months. The certification of the four elements was carried out by isotope-dilution-inductively coupled plasma mass spectrometry (ID-ICP-MS) with microwave-assisted digestion. Certification of candidate reference materials in a single laboratory was confirmed with interlaboratory comparison participated by a certain number of well-recognized testing laboratories in Korea. The certified values and expanded uncertainties (k = 2) for the candidate reference material with low level and the one with high level were (51.7 ± 2.1) mg kg−1 Cd, (103.8 ± 2.9) mg kg−1 Cd, (98.8 ± 4.5) mg kg−1 Cr, (1004 ± 49.8) mg kg−1 Cr, (107.4 ± 4.6) mg kg−1 Hg, (1133 ± 50.7) mg kg−1 Hg, (94.8 ± 3.7) mg kg−1 Pb and (988.4 ± 53.6) mg kg−1 Pb, respectively. The reference materials developed in this study demonstrated their suitability for the quality assurance in Cd, Cr, Hg and Pb analysis for the implementation of RoHS Directive.  相似文献   

13.
Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of polychlorinated biphenyls (PCBs). The raw materials for the CRMs were an insulation oil (CRM 7902-a and CRM 7903-a) and a fuel oil (CRM7904-a and CRM 7905-a). A solution of PCB3, PCB8, and technical PCB products, comprising four types of Kaneclor, was added to the oil matrices. The total PCB concentrations in the PCB-fortified oils (CRM 7902-a and CRM 7904-a) are approximately 6 mg kg−1. In addition, the mineral oils which were not fortified with PCBs were also distributed as CRMs (CRM 7903-a and CRM 7905-a). Characterization of these CRMs was conducted by the NMIJ/AIST, where the mineral oils and the PCB solution were analyzed using multiple analytical methods such as dimethylsulfoxide extraction, normal-phase liquid chromatography, gel permeation chromatography, reversed-phase liquid chromatography, and chromatography using sulfoxide-bonded silica; and/or various capillary columns for gas chromatography, and two ionization modes for mass spectrometry. The target compounds in the mineral oils and those in the PCB solution were determined by one of the primary methods of measurement, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 11 PCB congeners (PCB3, 8, 28, 52, 101, 118, 138, 153, 180, 194, and 206) in the CRMs. These CRMs have information values for PCB homologue concentrations determined by using a Japanese official method for determination of PCBs in wastes and densities determined with an oscillational density meter. Because oil samples having arbitrary PCB concentrations between respective property values of the PCB-fortified and nonfortified CRMs can be prepared by gravimetric mixing of the CRM pairs, these CRMs can be used for validation of PCB analyses using various instruments which have different sensitivities. Figure Preparation and certification processes of the mineral oil CRMs (example shown is polychlorinated biphenyls in insulation oil, high/low concentrations) Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

14.
A rapid method for analyzing brominated flame retardants (BFRs) was developed using direct exposure probe/mass spectrometry (DEP/MS). The BFRs used in this study included 1,2-bis(pentabromophenyl)ethane (EBP), tetrabromobisphenol A (TBBPA), and hexabromocyclododecane (HBCD), which are included in the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS).Quantitative analysis was conducted using octabromodiphenyl ether (octa-BDE), nonabromodiphenyl ether (nona-BDE), and decabromodiphenyl ether (deca-BDE). The samples were extracted by ultrasonication, following which the diluted sample solutions were analyzed by DEP/MS. Finally, the characteristic ions in the mass spectra of BFRs were identified.The limit of detection (LOD) and limit of quantification (LOQ) for deca-BDE were 0.163 and 0.495 mg/kg, respectively. The calibration curve showed a linearity (R2 = 0.9984) within 0.5-16 μg/mL. The relative standard deviation ranged from 2.78% to 6.76%. The octa-BDE and nona-BDE samples showed similar results. Finally, the certified reference material (CRM, NMIJ CRM 8108-a, Japan) for the deca-BDE analysis was used, and the recovery was 96.4%.  相似文献   

15.
Marin B  Chopin EI  Jupinet B  Gauthier D 《Talanta》2008,77(1):282-288
The aim of the study was to determine total trace (Cd, Co, Cr, Cu, Mn, Pb and Zn) and major (Al and Fe) element concentrations in calcareous soils using microwave-assisted digestion procedures. The literature showing lack of consensus regarding digestion procedures and unsatisfying recoveries for calcareous materials, four procedures using various acid combinations (HCl, HNO3, H2O2, HF) and volumes were tested using a certified reference material (CRM 141R) and natural calcareous soil samples. Digests were analysed by inductively coupled plasma-atomic emission spectrometry (ICP-AES). Repeatability (R.S.D. <5%) and recoveries (82-116%) showed that the procedures were precise and accurate for most elements. Five calcareous soil samples from a Champagne vineyard plot were, then, subjected to these procedures. In calcareous materials, the presence of HF resulted in Al being severely underestimated (recovery <5%) and Co overestimated (recovery >124%) due to complex formation or spectrochemical interferences, respectively. As digestion was not significantly influenced by the addition of H2O2, the procedure corresponding to Aqua regia (HCl-HNO3) appeared as the best compromise and was selected for further multielemental environmental studies on calcareous materials, even if the absence of HF could lead to incomplete digestion of accessory silicate minerals. Results for a vineyard plot showed that the soils were contaminated (3.65 mg kg−1 Cd, 67 mg kg−1 Cr, 278 mg kg−1 Cu, 143 mg kg−1 Pb and 400 mg kg−1 Zn) as a consequence of urban waste and copper-treatment applications.  相似文献   

16.
Two marine sediment certified reference materials, NMIJ CRM 7304-a and 7305-a, have been issued by the National Metrology Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) for the determination of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs). The raw materials of the CRMs were collected from a bay near industrial activity in Japan. Characterization of these CRMs was conducted by NMIJ, where the sediments were analyzed using multiple analytical methods such as pressurized liquid extraction (PLE), microwave-assisted extraction (MAE), saponification, Soxhlet extraction, supercritical fluid extraction (SFE), and ultrasonic extraction; the target compounds were determined by one of the primary methods of measurements, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 14 PCB congeners (PCB numbers 3, 15, 28, 31, 70, 101, 105, 138, 153, 170, 180, 194, 206, 209) and 4 OCPs (γ-HCH, 4,4′-DDT, 4,4′-DDE, 4,4′-DDD) in both CRMs. NMIJ CRM 7304-a has concentrations of the contaminants that are a factor of 2–15 greater than in CRM 7305-a. Both CRMs have information values for PCB homolog concentrations determined by collaborative analysis using a Japanese official method for determination of PCBs. The total PCB concentrations in the CRMs are approximately 920 and 86 μg kg−1 dry mass respectively. Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users.  相似文献   

17.
A new cod fish tissue certified reference material, NMIJ CRM 7402-a, for methylmercury analysis was certified by the National Metrological Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Cod fish was collected from the sea close to Japan. The cod muscle was powdered by freeze-pulverization and was placed into 600 glass bottles (10 g each), which were sterilized with γ-ray irradiation. The certification was carried out using species-specific isotope dilution gas chromatography inductively coupled plasma mass spectrometry (SSID–GC–ICPMS), where 202Hg-enriched methylmercury (MeHg) was used as the spike compound. In order to avoid any possible analytical biases caused by nonquantitative extraction, degradation and/or formation of MeHg in sample preparations, two different extraction methods (KOH/methanol and HCl/methanol extractions) were performed, and one of these extraction methods utilized two different derivatization methods (ethylation and phenylation). A double ID method was adopted to minimize the uncertainty arising from the analyses. In order to ensure not only the reliability of the analytical results but also traceability to SI units, the standard solution of MeHg used for the reverse-ID was prepared from high-purity MeHg chloride and was carefully assayed as follows: the total mercury was determined by ID–ICPMS following aqua regia digestion, and the ratio of Hg as MeHg to the total Hg content was estimated by GC–ICPMS. The certified value given for MeHg is 0.58 ± 0.02 mg kg−1 as Hg. Figure NMIJ CRM 7402-a: cod fish tissue for MeHg analysis  相似文献   

18.
The concentrations of Cu, Zn, Mn, Fe, K, Ca, Mg, Al, Ba and B in 26 herbal drugs of special importance in phytopharmacy were studied. Flame atomic absorption and emission spectrometry (FAAS, FAES), as well as inductively coupled plasma atomic emission spectrometry (ICP-AES), were applied in this work. The whole procedure, from sample preparation, via dissolution, to measurements, was validated by using CRM (NIST 1573a—tomato leaves), and the obtained recovery values are in the range from 91 to 102%. Drug samples originated from medicinal plants cultivated in Serbia contained Cu (4.47-14.08 mg kg−1), Zn (8.4-54.5 mg kg−1), Mn (9-155 mg kg−1), Fe (47-546 mg kg−1), K (0.20-6.24%), Ca (0.18-1.84%), Mg (0.13-1.09%), Al (16-416 mg kg−1), Ba (11.70-84.83 mg kg−1) and B (5.1-118.7 mg kg−1). In order to get a better insight into the elemental patterns, a common chemometric approach to data evaluation was used. Four significant factors identified by principal component analysis (PCA) were attributed partly to the significant influential sources and high mobility of some elements thus referring to potential anthropogenic contamination as well.  相似文献   

19.
Mineral content and botanical origin of Spanish honeys   总被引:2,自引:0,他引:2  
Eleven elements (Zn, P, B, Mn, Mg, Cu, Ca, Ba, Sr, Na and K) were determined by inductively plasma coupled spectrometry in 40 honey samples from different places of Spain and four different botanical origins: Eucalyptus (Eucalyptus sp.), Heather (Erica sp.), Orange-blossom (Citrus sinensis) and Rosemary (Rosmarinus officinalis). K, Ca and P show the higher levels with average concentrations ranged between 434.1-1935 mg kg−1 for K; 42.59-341.0 mg kg−1 for Ca and 51.17-154.3 mg kg−1 for P. Levels of Cu (0.531-2.117 mg kg−1), Ba (0.106-1.264 mg kg−1) and Sr (0.257-1.462 mg kg−1) are the lowest in all honey samples. Zn (1.332-7.825 mg kg−1), Mn (0.133-9.471 mg kg−1), Mg (13.26-74.38 mg kg−1) and Na (11.69-218.5 mg kg−1) concentrations were found strongly dependent on the kind of botanical origin.Results were submitted to pattern recognition procedures, unsupervised methods such as cluster and principal components analysis and supervised learning methods like linear discriminant analysis in order to evaluate the existence of data patterns and the possibility of differentiation of Spanish honeys from different botanical origins according to their mineral content. Cluster analysis shows four clusters corresponding to the four botanical origins of honey and PCA explained 71% of the variance with the first two PC variables. The best-grouped honeys were those from heather; eucalyptus honeys formed a more dispersed group and finally orange-blossom and rosemary honeys formed a less distinguishable group.  相似文献   

20.
This paper describes selenium determination based on Se0 preconcentration in the imprinted polymer (synthesized with 2.25 mmol SeO2, 4-vinylpyridine and 1-vinylimidazole) with subsequent detection on-line in HG-FAAS. During the synthesis, SeO2 is reduced to Se (0). Therefore, there are no MIP neither IIP in the present work, thus we denominated: AIP, i.e., atomically imprinted polymers. For the optimization of analytical parameters Doehlert design was used. The method presented limit of detection and limit of quantification of 53 and 177 ng L−1, respectively, and linear range from 0.17 up to 6 μg L−1 (r = 0.9936). The preconcentration factor (PF), consumptive index (CI) and concentration efficiency (CE) were 232; 0.06 mL and 58 min−1 respectively. The proposed method was successfully applied to determine Se in Brazil nuts (0.33 ± 0.03 mg kg−1), apricot (0.46 ± 0.02 mg kg−1), white bean (0.47 ± 0.03 mg kg−1), rice flour (0.47 ± 0.02 mg kg−1) and milk powder (0.22 ± 0.01 mg kg−1) samples. It was possible to do 12 analyzes per hour. Accuracy was checked and confirmed by analyzing certified reference material (DORM-2, dogfish muscle), and samples precision was satisfactory with RSD lower than 10%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号