共查询到20条相似文献,搜索用时 140 毫秒
1.
A magnetic nanosorbent was prepared from Fe3O4 nanoparticles and polyacrylamide using a solvothermal process. Two functions are achieved simultaneously in this process: The first consists in the formation of a carbon layer around the Fe3O4 nanoparticles, and the second one in the functionalization with an amido group. This combination allows the protection of Fe3O4 nanoparticles from dissolution in acid medium during heavy metal adsorption. The adsorbent was characterized by SEM, TEM, EDS, FTIR, TGA, and in terms of surface area. Results showed the Fe3O4 nanoparticles to be embedded in a sheet of carbon with folded surfaces which is functionalized with amido groups. The nanosorbent was applied to the enrichment of Cr(III), Co(II), Cd(II), Zn(II) and Pb(II) via magnetic solid phase extraction (mag-SPE). The effects of pH value, eluent type and sample volume were optimized. The validation of the procedure was verified by the analysis of a wheat gluten certified reference material (8418). The limits of detection for the above ions range from 1 to 110 ng L?1. The relative standard deviations are <10%. The procedure was successfully applied to the enrichment of Cr(III), Co(II), Cd(II), Zn(II) and Pb(II) from various water and food samples. 相似文献
2.
An amino acid derived ionic liquid, Fe3O4 nanoparticles and graphene oxide (GO) were used to prepare a material for the magnetic solid phase extraction (MSPE) of the ions Al(III), Cr(III), Cu(II) and Pb(II). The material was characterized by Fourier transform infrared spectral (FT-IR), scanning electron microscopy (SEM), thermal gravimetric analysis (TGA), magnetic analysis and isoelectric point (pI) analysis. It is shown to be a viable sorbent for the separation of these metal ions. Single factor experiments were carried out to optimize adsorption including pH values, ionic strength, temperature and solution volume. Following desorption with 0.1 M HCl, the ions were quantified by inductively coupled plasma optical emission spectrometry. Under the optimum conditions, the method provides a linear range from 10 to 170 μg· L?1 for Al(III); from 4.0 to 200 μg· L?1 for Cr(III); from 5.0 to 170 μg· L?1 for Cu(II); and from 5.0 to 200 μg· L?1 for Pb(II). The limits of detection (LOD) are 6.2 ng L?1 for Al(III); 1.6 ng L?1 for Cr(III); 0.52 ng L?1 for Cu(II); and 30 ng L?1 for Pb(II). Method performance was investigated by determination of these ions in (spiked) environmental water and gave recoveries in the range of 89.1%–117.8%. 相似文献
3.
Various carbon nanomaterials for use in anodic stripping voltammetric analysis of Hg(II), Cu(II), Pb(II) and Cd(II) are screened. Graphene, carbon nanotubes, carbon nanofibers and fullerene (C60), dispersed in chitosan (Chit) aqueous solution, are used to modify a glassy carbon electrode (GCE). The fullerene-chitosan modified GCE (C60-Chit/GCE) displays superior performance in terms of simultaneous determination of the above ions. The electrodes and materials are characterized by electrochemical impedance spectroscopy, cyclic voltammetry, scanning electron microscopy, Raman spectroscopy, X-ray diffraction and X-ray photoelectron spectroscopy. The excellent performance of C60-Chit/GCE is attributed to the good electrical conductivity, large surface area, strong adsorption affinity and unique crystalline structure of C60. Using differential pulse anodic stripping voltammetry, the assay has the following features for Hg(II), Cu(II), Pb(II) and Cd(II), respectively: (a) Peak voltages of +0.14, ?0.11, ?0.58 and???0.82 V (vs SCE); (b) linear ranges extending from 0.01–6.0 μM, 0.05–6.0 μM, 0.005–6.0 μM and 0.5–9.0 μM; and (c), detection limits (3σ method) of 3 nM (0.6 ppb), 14 nM (0.9 ppb), 1 nM (0.2 ppb) and 21 nM (2.4 ppb). Moreover, the modified GCE is well reproducible and suitable for long-term usage. The method was successfully applied to the simultaneous determination of these ions in spiked foodstuff. 相似文献
4.
The authors report on a disposable sensor for the differential pulse anodic stripping voltammetric (DPASV) determination of the ions Zn(II), Pb(II) and Cu(II). Simultaneous detection is accomplished by using a screen-printed carbon electrode (SPCE) co-modified with an in-situ plated bismuth (Bi)) film and gold nanoparticles (AuNPs). The synergistic effect of the Bi film, and the large surface and good electrical conductivity of the AuNPs strongly assist in the co-deposition of the three ions. Four well-defined and fully separated anodic stripping peaks, at 540 mV for Zn(II), 50 mV for Pb(II), 140 mV for Bi(III) and 295 mV for Cu(II), all vs. Ag/AgCl, can be seen. The modified SPCE was characterized by scanning electron microscopy, X-ray diffraction, cyclic voltammetry and electrochemical impedance spectroscopy. Under the optimized conditions, the sensor has a good response to these ions. The detection limits (at an S/N ratio of 3) are 50 ng·L?1 for Zn(II), 20 ng·L?1 for Pb(II), and 30 ng·L?1 for Cu(II). The method was applied to the determination of the 3 ions in spiked lake water samples. 相似文献
5.
We describe a colorimetric assay for mercury(II) ion. It is based on a hybridization chain reaction (HCR) and the use of Fe3O4@Au nanoparticles (NPs). Aptamers specific for Hg(II) were immobilized on the surface of the Fe3O4@AuNPs. The presence of Hg(II) inhibits the HCR process and this enables less Methylene Blue (MB) to intercalate into the dsDNA structure. After magnetic separation of the DNA-loaded NPs carrying Hg(II), the change in the absorbance of the residual MB solution is measured at 663 nm. The respective calibration plot is linear in the 1 to 300 nM concentration range, with a 0.7 nM detection limit (at a signal-to-noise ratio of 3). The method displays excellent selectivity over other metal ions. It was applied to the analysis of Hg(II) in spiked river water. 相似文献
6.
The authors describe a highly sensitive and selective photoelectrochemical (PEC) assay for mercury(II) ions. It is based on a dual signal amplification strategy. The first enhancement results from the surface plasmon resonance (SPR) of Au@Ag nanoparticles (NPs) absorbed on MoS2 nanosheets. Here, the injection of hot electrons of Au@Ag NPs into MoS2 nanosheets produces a strong photocurrent, while background signals are strongly reduced. The second enhancement results from the use of a thymine rich ct-DNA aptamer attached to the Au@Ag-MoS2 nanohybrid. The DNA specifically binds Hg(II) ions to form thymine-Hg(II)-thymine (T-Hg-T) complexes. This leads to the formation of a hairpin-shaped dsDNA structure. The use of a CdSe quantum dot label at the terminal end of the ct-DNA further facilitates electron–hole separation. The photocurrent of the detector is measured as a function of Hg(II) concentration at a bias voltage of 0.1 V and under irradiation of 430 nm light. Due to the two-fold amplification strategy presented here, the linear range extends from 10 pmol·L?1 to 100 nmol·L?1, with a detection limit of 5 pmol·L?1 (at S/N?=?3). 相似文献
7.
This paper describes the preparation of zwitterion-functionalized polymer microspheres (ZPMs) and their application to simultaneous enrichment of V(V), Cr(III), As(III), Sn(IV), Sb(III) and Hg(II) from environmental water samples. The ZPMs were prepared by emulsion copolymerization of ethyl methacrylate, 2-diethylaminoethyl methacrylate and triethylene glycol dimethyl acrylate followed by modification with 1,3-propanesultone. The components were analyzed by elemental analyses as well as Fourier transform infrared spectroscopy, and the structures were characterized by scanning electron microscopy and transmission electron microscopy. The ZPMs were packed into a mini-column for on-line solid-phase extraction (SPE) of the above metal ions. Following extraction with 40 mM NH4NO3 and 0.5 M HNO3 solution, the ions were quantified by ICP-MS. Under the optimized conditions, the enrichment factors (from a 40 mL sample) are up to 60 for the ions V(V), As(III), Sb(III) and Hg(II), and 55 for Cr(III) and Sn(IV). The detection limits are 1.2, 3.4, 1.0, 3.7, 2.1 and 1.6 ng L?1 for V(V), Cr(III), As(III), Sn(IV), Sb(III) and Hg(II), respectively, and the relative standard deviations (RSDs) are below 5.2%. The feasibility and accuracy of the method were validated by successfully analyzing six certified reference materials as well as lake, well and river waters. 相似文献
8.
The article describes a bienzyme visual system for aptamer-based assay of Hg(II) at nanomolar levels. The detection scheme is based on the finding that Hg(II) ions captured by aptamer-functionalized magnetic beads are capable of inhibiting the enzymatic activity of uricase and thus affect the formation of H2O2 and the blue product, i.e., oxidized tetramethylbenzidine. This strategy allows for a visual detection of Hg(II) at nanomolar levels without additional amplification procedure. Measuring the absorbance at 650 nm, the logarithmic calibration plot is linear in the concentration range of 0.5–50 nM and the limit of detection (LOD) is 0.15 nM. This is as low as the LOD obtained by atomic fluorescence spectrometry (AFS). The ions K+, Mg2+, Na+, Ca2+, Cu2+, Zn2+, Fe3+, Al3+, Co2+, AsO2 ?, Ni2+, Cd2+ and Pb2+ do not have a significant effect on color formation. The method was applied to the analysis of (spiked) river water, lake water, mineral water, tap water and certified reference water samples, and the results agreed well with those obtained by AFS or certified values, with recoveries ranging from 97% to 109%. The relative standard deviation for five parallel detections at a 10 nM Hg(II) level is 5.2%. 相似文献
9.
Magnesium(II)-doped nickel ferrite (Mg–NiFe2O4) nanoparticles are introduced as a new adsorbent for magnetic solid phase extraction of lead(II) ions from aqueous solutions. The structure and morphology of the adsorbent was characterized by FTIR, X-ray diffraction and scanning electron microscopy. The effects of pH value, amount of adsorbent, type, concentration and volume of the eluent and adsorption/desorption time on the extraction efficiency were studied. Following elution with hydrochloric acid, Pb(II) ions were quantified by flame atomic absorption spectrometry. Under optimized conditions, the calibration graph is linear in the 0.5–125 ng mL?1 Pb(II) ion concentration range. Other figures of merit include (a) a 0.2 ng mL?1 limit of detection, (b) an enrichment factor of 200, (c) an intra-day relative standard deviation (for n =?6 at 50 ng mL?1) of 1.6%, and (d) an inter-day precision of 3.8%. The method was validated by the analysis of the certified reference material, NIST SRM 1566b. It was successfully applied to the determination of Pb(II) ion in spiked water samples, industrial wastewater and acidic lead battery waters. 相似文献
10.
A simple method is described for the determination of copper(II) ions based on the cathodic electrochemiluminescence (ECL) of lucigenin which is quenched by Cu(II). The blue ECL is best induced at ?0.45 V (vs. Ag/AgCl) at a scan rate of 50 mV·s?1. Under optimum conditions, the calibration plot is linear in the 3.0 to 1000 nM Cu(II) concentration range. The limit of detection is 2.1 nM at a signal-to-noise ratio of 3. Compared to other analytical methods, the one presented here is simple, fast, selective and cost-effective. It has been successfully applied in the analysis of copper ions in spiked tap water samples with recoveries ranging from 93.0% (at 50 nM concentration) to 105.7% (at 150 nM). 相似文献
11.
Diphenyl diselenide was immobilized on chitosan loaded with magnetite (Fe3O4) nanoparticles to give an efficient and cost-effective nanosorbent for the preconcentration of Pb(II), Cd(II), Ni(II) and Cu(II) ions by using effervescent salt-assisted dispersive magnetic micro solid-phase extraction (EA-DM-μSPE). The metal ions were desorbed from the sorbent with 3M nitric acid and then quantified via microflame AAS. The main parameters affecting the extraction were optimized using a one-at-a-time method. Under optimum condition, the limits of detection, linear dynamic ranges, and relative standard deviations (for n?=?3) are as following: Pb(II): 2.0 ng·mL?1; 6.3–900 ng·mL?1; 1.5%. Cd(II): 0.15 ng·mL?1; 0.7–85 ng·mL?1, 3.2%; Ni(II): 1.6 ng·mL?1,.6.0–600. ng·mL?1, 4.1%; Cu(II): 1.2 ng·mL?1, 3.0–300 ng·mL?1, 2.2%. The nanosorbent can be reused at least 4 times. 相似文献
12.
A time-resolved phosphorescence (TRP) is applied to the highly sensitive determination of Fe(II) ions. The method is based on the use of a phosphorescent probe consisting of cysteine-bridged Mn-doped ZnS quantum dots (Mn/ZnS QDs). The presence of cysteine enhances the phosphorescence of the QDs and also increases the efficiency of quenching caused by Fe(II) ions. This results in strongly improved selectivity for Fe(II). The linear response is obtained in the concentration range of 50–1000 nM with a 19 nM detection limit. Phosphorescence is recorded at excitation/emission peaks of 301/602 nm. The interference of short-lived fluorescent and scattering background from the biological fluids is eliminated by using the TRP mode with a delay time of 200 μs. The determination of Fe(II) in human serum samples spiked at a 150 nM level gave a 92.4% recovery when using the TRP mode, but only 52.4% when using steady-state phosphorescence. This demonstrates that this probe along with TRP detection enables highly sensitive and accurate determination of Fe(II) in serum. 相似文献
13.
Novel composites were obtained via direct assembly of polysulfides (Sx2?, X?=?3, 4, 6) on the surface of a metal organic framework (MOF; type benzene-1,3,5-tricarboxylic/Cu(II). They are referred to as Sx-MOFs and were used for highly selective and efficient extraction of ultra-trace amounts of heavy metal ions from aqueous solutions. The structure of the Sx-MOFs was characterized by Raman spectroscopy, FT-IR, X-ray diffraction, and scanning electron microscopy. The Raman spectra of Sx-MOF is similar to the bare MOF and shows the MOFs structure to be well retained after Sx functionalization. The selective interaction of Sx with soft metal ions and the high surface area of MOFs resulted in excellent affinity and selectivity for ions such as Hg(II). The Sx-MOFs of type S4-MOF had the highest distribution coefficient Kd value (~107) and best extraction recovery (~100%) for Hg(II). The S4-MOF also has high selectivity in the following order: Hg(II) >?>?Pb(II)?>?Zn(II)?>?Ni(II)?>?Co(II). The binding process of the metals occurs via M–S bonding. The ions were quantified by inductively coupled plasma optical emission spectrometry (ICP-OES). The detection limit for Hg(II) is 0.13 μg L?1. The S4-MOF was applied to the extraction of trace metal ions from natural and contaminated waters and data were compared with other sorbets. The results revealed that S4-MOF is an excellent adsorbent for sorption of heavy metal ions even in the presence of the relatively high concentration of other ions. 相似文献
14.
The authors describe an amperometric biosensor for the determination As(III) and Cd(II) based on the inhibition of the enzyme acetylcholineesterase (AChE). A platinum electrode was modified with ruthenium(II)-tris(bipyridyl), graphene oxide and AChE and then showed redox peaks at 0.06 and 0.2 V vs Ag/AgCl in the presence of acetylthiocholine chloride (ATChCl). Amperometry unveiled a steady-state turnover rate with the release of thiocholine. In the presence of arsenic(III) and cadmium(II), AChE showed an inhibitive response at 0.214 and 0.233 V vs Ag/AgCl, respectively. The electrode exhibits a detection limit and linear range of 0.03 μM and 0.05–0.8 μM for As(III) and 0.07 μM and 0.02–0.7 μM for Cd(II), respectively. Type of inhibition and inhibition constants induced by As(III) and Cd(II) on the catalytic sites of AChE were determined from Dixon and Lineweaver-Burk plots. The modified electrode was applied to the determination of As3+ and Cd2+ in river, tap and waste water, and the results proved that the method is sensitive and can be an alternative to chromatographic and spectroscopic techniques. 相似文献
15.
Mohamed A. Habila Zeid A. ALOthman Ahmed Mohamed El-Toni Joselito Puzon Labis Xiaomin Li Fan Zhang Mustafa Soylak 《Mikrochimica acta》2016,183(8):2377-2384
The authors describe double-shell magnetic nanoparticles functionalized with 2-mercaptobenzothiazole (MBT) to give nanospheres of the type MBT-Fe3O4@SiO2@C). These are shown to be viable and acid-resistant adsorbents for magnetic separation of the heavy metal ions Ni(II), Cu(II) and Pb(II). MBT act as a binding reagent, and the carbon shell and the silica shell protect the magnetic core. Following 12 min incubation, the loaded nanospheres are magnetically separated, the ions are eluted with 2 M nitric acid and then determined by inductively coupled plasma-mass spectroscopy. The limits of detection of this method are 2, 82 and 103 ng L ̄1 for Ni(II), Cu(II), and Pb(II) ions, respectively, and the relative standard deviations (for n = 7) are 6, 7.8, and 7.4 %. The protocol is successfully applied to the quantitation of these ions in tap water and food samples (mint, cabbage, potato, peas). Recoveries from spiked water samples ranged from 97 to 100 %. 相似文献
16.
Polyimide (PI) sheets were laser etched to obtain graphene-based carbon nanomaterials (LEGCNs). These were analyzed by scanning electron microscopy, X-ray diffraction and Raman spectroscopy which confirmed the presence of stacked multilayer graphene nanosheets. Their large specific surface and large number of edge-plane active sites facilitate the accumulation of metal ions. A glassy carbon electrode (GCE) with an in-situ plated bismuth film was modified with the LEGCNs to give a sensor with satisfactory response for the simultaneous determination of cadmium(II) and lead(II) by means of square wave anodic stripping voltammetry. It appears that is the first report on an electrochemical sensor based on the use of laser etched graphene for determination of heavy metal ions. Figures of merit for detection of Cd(II) include (a) a low and well separated working potential of ?0.80 V (vs. Ag/AgCl), (b) a wide linear range (from 7 to 120 μg·L?1), and a low detection limits 0.47 μg·L?1. The respective data for Pb(II) are (a) -0.55 V, (b) 5 to 120 μg·L?1, and (c) 0.41 μg·L?1. The modified GCE displays remarkable repeatability, reproducibility, selectivity and stability. The sensor was applied to the simultaneous determination of Cd(II) and Pb(II) in spiked real water samples. The results confirm that the laser etching technique is an efficient tool for the preparation of carbon nanomaterials with high quality and great sensing performance. 相似文献
17.
Magnetite nanoparticles were surface-modified with mercaptoacetic acid (MAA), complexed with Zn(II), and then treated with the dual Schiff base (referred to as imine-based ligand; IBL; obtained by reaction of p-aminobenzoic acid and 2,3-butanedione) to give particles with an architecture of type Fe3O4@MAA@IBL. These are shown to be viable sorbents for magnetic solid phase extraction of organochlorine pesticides (OCPs) from seawater samples. Efficient extraction of the OCPs probably is due to lone pair-π, π-complexation and π-interactions. The sorbent was characterized by transmission electron microscopy, scanning electron microscopy, FT-IR and energy-dispersive X-ray spectroscopy. The effects of the volumes of sample, sorbent dosage and eluent, adsorption and desorption times, and the salinity of the sample on the extraction efficiencies were optimized. The OCPs (heptachlor, aldrin, dieldrin, p,p’-DDE and p,p’-DDT) were quantified by gas chromatography with microelectron capture detection. Under optimal conditions, the limit of detections range was between 1.0 and 1.9 ng L?1. The enrichment factors are between 84.1 and 99.9 %. The sorbent was applied to the rapid extraction of trace quantities of OCPs from seawater samples and gave good relative recoveries (78 to 108 %) and relative standard deviations (<8.3 %). 相似文献
18.
The authors describe the synthesis of a multifunctional nanocomposite with an architecture of type Fe3O4@SiO2@graphene quantum dots with an average diameter of about 22 nm. The graphene quantum dots (GQDs) were covalently immobilized on the surface of silica-coated magnetite nanospheres via covalent linkage to surface amino groups. The nanocomposite displays a strong fluorescence (with excitation/emission peaks at 330/420 nm) that is fairly selectively quenched by Hg2+ ions, presumably due to nonradiative electron/hole recombination annihilation. Under the optimized experimental conditions, the linear response to Hg2+ covers the 0.1 to 70 μM concentration range, with a 30 nM lower detection limit. The high specific surface area and abundant binding sites of the GQDs result in a good adsorption capacity for Hg2+ (68 mg?g?1). The material, due to its superparamagnetism, can be separated by using a magnet and also is recyclable with EDTA so that it can be repeatedly used for simultaneous detection and removal of Hg2+ from contaminated water. 相似文献
19.
This study presents a method for the selective determination of Hg(II) using electromembrane extraction (EME), followed by square wave anodic stripping voltammetry (SWASV), using a gold nanoparticle-modified glassy carbon electrode, (AuNP/GCE). By applying an electrical potential of typically 60 V for 12 min through a thin supported liquid membrane (1-octanol), Hg(II) ions are extracted from a donor phase (i.e., the sample solution) to an acidic acceptor solution (15 μL) placed in the lumen of a hollow fiber. The influences of experimental parameters during EME were optimized using face-centered central composite design. The calibration plot, established at a working voltage of 0.55 V (vs. Ag/AgCl), extends from 0.2 to 10 μg.L?1 of Hg(II). The limit of detection, at a signal to noise ratio of 3, is 0.01 μg.L?1 and the relative standard deviations (for 5 replicate determinations at 3 concentration levels) are between 7.5 and 8.7 %. The method was successfully applied to the determination of Hg(II) in spiked real water samples to give recoveries ranging from 89 to 97 %. The results were validated by cold vapor atomic absorption spectroscopy. 相似文献
20.
Magnetic microspheres (Fe3O4) were coated with polydopamine (PDA) and loaded with the metal ions Ti(IV) and Nb(V) to give a material of type Fe3O4@PDA-Ti/Nb. It is shown to be useful for affinity chromatography and for enrichment of phosphopeptides from both standard protein solutions and real samples. For comparison, such microspheres loaded with single metal ions only (Fe3O4@PDA-Ti and Fe3O4@PDA-Nb) and their physical mixtures were also investigated under identical conditions. The binary metal ion-loaded magnetic microspheres display better enrichment efficiency than the single metal ion-loaded microspheres and their physical mixture. Both multiphosphopeptides and monophosphopeptides can be extracted. The Fe3O4@PDA-Ti/Nb microspheres exhibit ultra-high sensitivity (the lowest detection amount being 2 fmol) and selectivity at a low mass ratio such as in case of β-casein/BSA (1:1000). 相似文献