首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The authors describe the synthesis of a multifunctional nanocomposite with an architecture of type Fe3O4@SiO2@graphene quantum dots with an average diameter of about 22 nm. The graphene quantum dots (GQDs) were covalently immobilized on the surface of silica-coated magnetite nanospheres via covalent linkage to surface amino groups. The nanocomposite displays a strong fluorescence (with excitation/emission peaks at 330/420 nm) that is fairly selectively quenched by Hg2+ ions, presumably due to nonradiative electron/hole recombination annihilation. Under the optimized experimental conditions, the linear response to Hg2+ covers the 0.1 to 70 μM concentration range, with a 30 nM lower detection limit. The high specific surface area and abundant binding sites of the GQDs result in a good adsorption capacity for Hg2+ (68 mg?g?1). The material, due to its superparamagnetism, can be separated by using a magnet and also is recyclable with EDTA so that it can be repeatedly used for simultaneous detection and removal of Hg2+ from contaminated water.
Graphical abstract A schematic view of preparation process for the Fe3O4@SiO2@graphene quantum dots nanocomposite (denoted as Fe3O4@SiO2@GQDs). The graphene quantum dots were covalently immobilized on the surface of silica-coated magnetite nanospheres (Fe3O4@SiO2) via covalent linkage to surface amino groups.
  相似文献   

2.
The authors describe an amperometric sensor for dopamine (DA) by employing olive-like Fe2O3 microspheres (OFMs) as the electrocatalyst for DA oxidization. The OFMs were prepared by using a protein templated method. The structure and properties of the OFMs were characterized by scanning electron microscopy, X-ray powder diffraction, energy dispersive x-ray spectroscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The OFMs possess excellent catalytic activity towards DA oxidization due to their unique morphology. The sensor responds to DA within less than 5 s. The sensor, best operated at a voltage of +0.2 V (vs. SCE) responds linearly in the 0.2 to 115 μM DA concentration range and has a 30 nM detection limit. The selectivity, reproducibility and long-term stability of the sensor are acceptable. It performs well when applied to spiked human urine samples.
Graphical abstract Olive-like Fe2O3 microspheres (OFMs), synthesized using egg white as template, display excellent catalytic activity towards dopamine (DA) oxidization due to their unique morphology. They were applied for DA detection using the amperometric technique. The electrochemical sensor exhibited a high sensitivity and a 30 nM detection limit. DAQ: dopaquinone.
  相似文献   

3.
The authors describe a 3-component nanoparticle system composed of a silica-coated magnetite (Fe3O4) core and a layered double (Cu-Cr) hydroxide nanoplatelet shell. The sorbent has a high anion exchange capacity for extraction anionic species. A simple online system, referred to as "on-line packed magnetic-in-tube solid phase microextraction" was designed. The nanoparticles were placed in a stainless steel cartridge via dry packing. The cartridge was then applied to the preconcentration acidic drugs including naproxen and indomethacin from urine and plasma. Extraction and desorption times, pH values of the sample solution and flow rates of sample solution and eluent were optimized. Analytes were then quantified by HPLC with UV detection. Under optimal conditions, the limits of detection range from 70 to 800 ng L?1, with linear responses from 0.1–500 μg L?1 (water samples), 0.6–500 μg L?1 (spiked urine), and 0.9–500 μg L?1 (spiked plasma). The inter- and intra-assay precisions (RSDs, for n?=?5) are in the range of 2.2–5.4%, 2.8–4.9%, and 2.0–5.2% at concentration levels of 5, 25 and 50 μg L?1, respectively. The method was applied to the analysis of the drugs in spiked human urine and plasma, and good results were achieved.
Graphical abstract Fe3O4@SiO2@CuCr-LDH magnetic nanoparticles were synthesized and packed in to a stainless steel column. The column was applied to solid phase microextraction of acidic drugs from biological samples.
  相似文献   

4.
An electrochemical microsensor for chloramphenicol (CAP) was fabricated by introducing magnetic Fe3O4 nanoparticles (NPs) onto the surface of activated carbon fibers. This microsensor exhibited increased electrochemical response toward CAP because of the synergetic effect of the Fe3O4 NPs and the carbon fibers. Cyclic voltammograms were acquired and displayed three stable and irreversible redox peaks in pH 7.0 solution. Under optimized conditions, the cathodic current peaks at ?0.67 V (vs. Ag/AgCl). The calibration plot is linear in the 40 pM to 1 μM CAP concentration range, with a 17 pM detection limit (at a signal-to-noise ratio of 3). The sensor was applied to the determination of CAP in spiked sediment samples. In our perception, this electrocatalytic platform provided a useful tool for fast, portable, and sensitive analysis of chloramphenicol.
Graphical abstract A sensitive carbon fiber microsensor modified with Fe3O4 nanoparticles is found to display two cathodic peaks when detecting chloramphenicol at 100 mV·s?1 and at pH 7.0. The sensor was applied to the determination of chloramphenicol in sediment samples.
  相似文献   

5.
The synthesis of rattle-type nanostructured Fe3O4@SnO2 is described along with their application to dispersive solid-phase extraction of trace amounts of mercury(II) ions prior to their determination by continuous-flow cold vapor atomic absorption spectrometry. The voids present in rattle-type structures make the material an effective substrate for adsorption of Hg(II), and also warrant high loading capacity. The unique morphology, large specific surface, magnetism property and the synergistic effect of magnetic cores and SnO2 shells render these magnetic nanorattles an attractive candidate for solid-phase extraction of heavy metal ions.The sorbent was characterized by transmission electron microscopy, scanning electron microscopy, FTIR, energy-dispersive X-ray spectroscopy and by the Brunnauer-Emmett-Teller technique. The effects of pH value, adsorption time, amount of sorbent, volume of sample solutions, concentration and volume of eluent on extraction efficiencies were evaluated. The calibration plot is linear in the 0.1 to 40 μg·L?1 concentration range, and the preconcentration factor is 49. The detection limit is 28 ng·L?1. The sorbent was applied to the analysis of (spiked) river and sea water samples. Recoveries ranged from 97.2 to 100.5%.
Graphical abstract A yolk-shell structure based on a Fe3O4 core and SnO2 shell was developed as an efficient MSPE sorbent. A middle silica layer was etched by alkaline solution. The resulting sorbent was utilized for preconcentration of mercury ions from aqueous media.
  相似文献   

6.
A magnetic sorbent was fabricated by coating the magnetized graphene oxide with polystyrene (PS) to obtain a sorbent of the type GO-Fe3O4@PS. The chemical composition and morphology of the sorbent were characterized. The sorbent was employed for the enrichment of polycyclic aromatic hydrocarbons (PAHs) from water samples. Various parameters affecting the enrichment were investigated. The PAHs were then quantified by gas chromatography with flame ionization detection. Linear responses were found in the range of 0.03–100 ng mL?1 for naphthalene and 2-methylnaphthalene, and of 0.01–100 ng mL?1 for fluorene and anthracene. The detection limits (at an S/N ratio of 3) range between 3 and 10 pg mL?1. The relative standard deviations (RSDs) for five replicates at three concentration levels (0.05, 5 and 50 ng mL?1) of analytes ranged from 4.9 to 7.4%. The method was applied to the analysis of spiked real water samples. Relative recoveries are between 95.8 and 99.5%, and RSD% are <8.4%.
Graphical abstract A magnetic sorbent was fabricated by polystyrene coated on the magnetic graphene oxide for the extraction and preconcentration of PAHs in water samples prior to their determination by gas chromatography with flame ionization detection.
  相似文献   

7.
A nanocomposite consisting of cetyltrimethylammonium bromide (CTAB), Fe3O4 nanoparticles and reduced graphene oxide (CTAB-Fe3O4-rGO) was prepared, characterized, and used to modify the surface of a glassy carbon electrode (GCE). The voltammetric response of the modified GCE to 4-nonylphenol (NPh) was investigated by cyclic voltammetry and revealed a strong peak at around 0.57 V (vs. SCE). Under optimum conditions, the calibration plot is linear in the ranges from 0.03 to 7.0 μM and from 7.0 to 15.0 μM, with a 8 nM detection limit which is lower that that of many other methods. The modified electrode has excellent fabrication reproducibility and was applied to the determination of NPh in spiked real water samples to give recoveries (at a spiking level of 1 μM) between 102.1 and 99.1%.
Graphical abstract A nanocomposite consisting of cetyltrimethylammonium bromide (CTAB), Fe3O4 nanoparticles and reduced graphene oxide (CTAB-Fe3O4-rGO) was prepared and used to modify the surface of a glassy carbon electrode (GCE) for the differential pulse voltammetric (DPV) determination of 4-nonylphenol (NPh).
  相似文献   

8.
The authors describe a cataluminescence (CTL) based sensing method via signals generated at the surface of In3LaTi2O10 nanoparticles for simultaneous determination of trimethylamine, formaldehyde and benzene in air. The analytical wavelengths are 340 nm, 440 nm and 600 nm, and the best surface temperature of the catalytic material is 275 °C. The limits of detection of this method are 0.3 mg?m?3 for trimethylamine, 0.07 mg?m?3 for formaldehyde, and 0.2 mg?m?3 for benzene. The linear ranges of CTL intensity versus gas/vapor concentration are from 1.0 to 65.1 mg?m?3 for trimethylamine, from 0.2 to 72.5 mg?m?3 for formaldehyde, and from 0.5 to 77.5 mg?m?3 for benzene. The recoveries after testing 10 standard samples ranged from 98.1% to 102.6% for trimethylamine, from 98.1% to 102.6% for formaldehyde, and from 97.7% to 103.8% for benzene. Gaseous ammonia, acetaldehyde, toluene, ethylbenzene, ethanol, sulfur dioxide and carbon dioxide do not interfere. The relative deviation of the CTL signals after 200 h of continuous detection of trimethylamine, formaldehyde and benzene is <3%.
Graphical abstract Schematic of a cataluminescence (CTL) based method for simultaneous determination of trimethylamine (TMA), formaldehyde (HCHO) and benzene (C6H6) in air. The linear ranges of CTL intensity versus gas/vapor concentration are from 1.0 to 65.1 mg?m?3 for TMA, from 0.2 to 72.5 mg?m?3 for HCHO, and from 0.5 to 77.5 mg?m?3 for C6H6.
  相似文献   

9.
The paper describes a sensitive method for simultaneous sensing of morphine (MOR) and diclofenac (DCF). The surface of a MgFe2O4/graphite paste electrode was modified with multi-walled carbon nanotubes, and the resulting sensor was characterized by cyclic voltammetry, differential pulse voltammetry, chronoamperometry, and electrochemical impedance spectroscopy. The electrode showed an efficient synergistic effect in term of oxidation of DCF and MOR, with sharp oxidation peaks occurring at +0.370 and 0.540 V (vs Ag/AgCl) at pH 7.0. The calibration plot for MOR is linear in the 50 nM to 920 μM concentration range, and the detection limit is 10 nM (at a signal-to-noise ratio of 3). The respective data for DCF are 100 nM to 580 μM, with a 60 nM LOD. The sensor was applied to the determination of MOR and DCF in spiked serum and urine samples, with recoveries ranging between 91.4 and 100.7 %.
Graphical abstract A sensitive method for simultaneous sensing of morphine (MOR) and diclofenac (DCF) is described. The surface of MgFe2O4/graphite paste electrode was modified with multi-walled carbon nanotubes, and the resulting sensor showed an efficient synergistic effect in terms of oxidation of DCF and MOR. The calibration plot for MOR is linear in the 50 nM to 920 μM concentration range, and the detection limit is 10 nM. The respective data for DCF are 100 nM to 580 μM, with a 60 nM LOD.
  相似文献   

10.
A temperature-responsive biosensing film consisting of the temperature-responsive block co-polymer poly (N-isopropylacrylamide)-b-poly(2-acrylamidoethyl benzoate) (referred to as PNIPAM-b-PAAE), graphene oxide (GO), and hemoglobin (Hb) was fabricated and used to modify a glassy carbon electrode (GCE). The film provides a favorable micro-environment for Hb to facilitate the electron transfer to the GCE. Hb at PNIPAM-b-PAAE/GO/Hb (PGH) film exhibits a couple of well-defined redox peaks with a formal potential of ?0.371 V (vs. SCE) and displays intrinsic electro-catalytic activity toward H2O2. The sensing film also shows temperature-tunable catalytic activity toward H2O2 that can be stimulated by temperature. Large peak currents can be seen in amperometry at 0.4 V (vs. SCE) in pH 7.0 phosphate buffer only if the temperature is above the lower critical solution temperature (LCST) of 32 °C. The response of the modified GCE is linear in the 0.1 to 3.7 μmol L?1 concentration range if operated at above 32 °C, but in the 0.2 to 3.7 μmol L?1 concentration range at below 30 °C. This behavior is attributed to the temperature-dependent phase transition of PNIPAM-b-PAAE and cooperative effect of GO. The strategy presented here in our perception meets the requirements of switchable sensors for use in bioscience and biotechnology.
Graphical abstract A temperature-responsive biosensing film consisting of temperature-responsive polymer, graphene oxide and hemoglobin has been fabricated. This film displays favorable electrochemical property and good electro-catalytic activity toward H2O2. It also exhibits catalytic activity change upon temperature stimuli.
  相似文献   

11.
The article describes the synthesis of core-shell magnetic nanoparticles (MNPs) of the type Fe3O4@MIL-100 (MIL standing for Material Institut Lavoisier), and their application as sorbent for magnetic solid-phase extraction (MSPE) of triclosan. The MNPs were prepared via circular self-assembly of ferric chloride and benzenetricarboxylic acid. The functionalized MNPs were characterized by transmission electron microscopy, FTIR and thermogravimetry. Following extraction, triclosan was eluted with ammoniacal methanol and then submitted to HPLC with UV detection. The amount of magnetic microspheres, sample pH and ionic strength, adsorption time, desorption time, desorption solvent and the volume of the eluent were optimized. Under optimum conditions, the method showed good linearity in the 0.1 to 50 mg·kg?1 triclosan concentration range in toothpaste samples. Other features include (a) intra-day and inter-day relative standard deviations (RSD, for n = 4) of <5.5 %, (b) a 30 μg·kg?1 limit of detection, and (c) extraction recoveries between 90.86 % and 101.1 %. The method was successfully applied to the determination of triclosan in children’s toothpaste.
Graphical abstract The article describes the synthesis of core-shell magnetic nanoparticles (MNPs) of the type Fe3O4@MIL-100, and their application as sorbent for magnetic solid-phase extraction (MSPE) of triclosan.
  相似文献   

12.
The authors describe a sensitive surface-enhanced Raman scattering (SERS)-based aptasensor for the detection of the food pathogen Vibrio parahaemolyticus. Nanostructures consisting of Fe3O4@Au particles wrapped with graphene oxide (GO) were used both as SERS substrates and separation tools. A first aptamer (apt 1) was immobilized on the Fe3O4@Au/GO nanostructures to act as a capture probe via the affinity binding of aptamer and V. parahaemolyticus. A second aptamer (apt-2) was modified with the Raman reporter molecule TAMRA to act as a SERS sensing probes that binds to the target the same way as the Fe3O4@Au/GO-apt 1. The sandwich formed between Fe3O4@Au/GO-apt 1/V. parahaemolyticus and apt 2-TAMRA can be separated with the aid of a magnet. The concentration of V. parahaemolyticus can be quantified by measurement of the SERS intensity of TAMRA. Under optimal conditions, the signal is linearly related to the V. parahaemolyticus concentration in the range between 1.4 × 102 to 1.4 × 106 cfu·mL?1, with a detection limit of 14 cfu·mL?1. Recoveries ranging from 98.5% to 105% are found when analyzing spiked salmon samples. In our perception, the assay described here is a useful tool for quantitation of V. parahaemolyticus in real samples.
Graphical abstract GO wrapped Fe3O4@Au nanostructures were synthesized as the substrate and modified with with a first aptamer (apt 1) to capture V. parahaemolyticus. TAMRA labelled aptamer 2 was then used as signal probe. The V. parahaemolyticus concentrations are closely related to the Raman intensity of TAMRA.
  相似文献   

13.
The authors describe magnetic nanoparticles consisting of an Fe3O4 core and a poly(methacrylic acid) coating for dispersive solid phase extraction (DSPE) of arsenic prior to its determination by hydride-generation microwave plasma AES (HG-MP-AES). The particles have an average size of 25 nm, can be prepared at low costs, and provide improved operational safety in combination with plasma generation. The methods allows arsenic to be determined with detection limits (at 3σ/m) of 3.0 ng?L?1 for As(III) and of 10.0 ng?L?1 of As(V). Recoveries of (spiked) samples range from 99.0 to 102%. This is the first report on the use of HG-MP-AES for speciation and preconcentration of arsenic using DSPE. The method displays detection limits that come close to those of ICP-OES and ICP-MS.
Graphical abstract A core/shell Fe3O4@poly(methacrylic acid) coated sorbent was synthesised and employed to the speciation of arsenic prior to its determination by hydride-generation microwave plasma atomic emission spectrometry.
  相似文献   

14.
An Al-doped ZnO@Fe3O4 nanocomposite was synthesized and used as a magnetic sorbent for solid-phase extraction of Cd(II) prior to its determination by flame atomic absorption spectrometry (FAAS). The size and morphology of the nano-sorbent were characterized via X-ray diffraction analysis, scanning electron microscopy and FTIR. Following its desorption with acetic acid, cadmium was quantified by FAAS. Factors affecting the extraction of the Cd(II) were optimized. Under optimized experimental conditions, the calibration graph is linear in the 0.6 to 60 ng mL?1 concentration range. The limit of detection is 0.17 ng mL?1 and the pre-concentration factor is 50. The inter- and intra-day relative standard deviations for six replicate determinations at a Cd(II) level of 40 ng mL?1 are 3.8% and 2.5%, respectively. The method was successfully applied to the trace determination of Cd(II) in spiked water samples. The accuracy of the method was confirmed by analyzing the certified reference material NIST SRM 1643e.
Graphical abstract Schematic of the synthesis of an Al-doped ZnO@Fe3O4 nanocomposite and its application as a magnetic sorbent for solid-phase extraction of Cd(II) prior to its determination by flame atomic absorption spectrometry (FAAS).
  相似文献   

15.
The authors describe an aptamer-based fluorescent assay for adenosine (Ade). It is based on the interaction between silver nanoparticles (AgNPs) and CdTe quantum dots (QDs). The beacon comprises a pair of aptamers, one conjugated to Fe3O4 magnetic nanoparticles, the other to AgNPs. In the presence of Ade, structural folding and sandwich association of the two attachments takes place. After magnetic separation, the associated sandwich structures are exposed to the QDs. The AgNPs in sandwich structures act as the signaling label of Ade by quenching the fluorescence of QDs (at excitation/emission wavelengths of 370/565 nm) via inner filter effect, electron transfer and trapping processes. As a result, the fluorescence of QDs drops with increasing Ade concentration. The assay has a linear response in the 0.1 nM to 30 nM Ade concentration range and a 60 pM limit of detection. The assay only takes 40 min which is the shortest among the aptamer-based methods ever reported. The method was successfully applied to the detection of Ade in spiked biological samples and satisfactory recoveries were obtained.
Graphical abstract Schematic of a highly efficient and convenient adenosine (Ade) fluorometric assay. It is based on the interaction between Ag nanoparticles (NPs) and CdTe quantum dots (QDs). Ade aptamers (ABA1 and ABA2) are used as recognition unit and Fe3O4 magnetic nanoparticles act as magnetic separator. The assay exhibits superior sensitivity and speediness.
  相似文献   

16.
The authors describe double-shell magnetic nanoparticles functionalized with 2-mercaptobenzothiazole (MBT) to give nanospheres of the type MBT-Fe3O4@SiO2@C). These are shown to be viable and acid-resistant adsorbents for magnetic separation of the heavy metal ions Ni(II), Cu(II) and Pb(II). MBT act as a binding reagent, and the carbon shell and the silica shell protect the magnetic core. Following 12 min incubation, the loaded nanospheres are magnetically separated, the ions are eluted with 2 M nitric acid and then determined by inductively coupled plasma-mass spectroscopy. The limits of detection of this method are 2, 82 and 103 ng L ̄1 for Ni(II), Cu(II), and Pb(II) ions, respectively, and the relative standard deviations (for n = 7) are 6, 7.8, and 7.4 %. The protocol is successfully applied to the quantitation of these ions in tap water and food samples (mint, cabbage, potato, peas). Recoveries from spiked water samples ranged from 97 to 100 %.
Graphical abstract Mercaptobenzothiazole-functionalized magnetic carbon nanospheres of type Fe3O4@SiO2@C were synthesized. Then applied for magnetic solid phase extraction of Ni(II), Cu(II) and Pb(II) from water and food samples with LOD of 0.002, 0.082 and 0.103 μg L?1 respectively.
  相似文献   

17.
We report on the synthesis of Fe3O4@SiO2 nanoparticles incorporated poly(divinylbenzene) monolithic column via in situ polymerization. The monolith had larger specific surface area and relatively uniform porous structure and was characterized by scanning electron microscopy, nitrogen adsorption–desorption, and Fourier transform infrared spectroscopy. The monolith was then applied for the evaluation of gas chromatography separation properties. Here, an electromagnetic induction heating technique was employed to control the column temperature with the thermal effect of eddy current in ferromagnetic materials Fe3O4. The monolith offered good separation efficiency for benzene and toluene and a higher column efficiency was obtained up to 4481 and 9216 plates per meter, respectively. In addition, the injection volume and column capacity of the proposed system are as much as 5 µL and 100 ng. This makes it possible to use a UV detector. The fabricated Fe3O4@SiO2 nanoparticles incorporated poly(divinylbenzene) monolithic column has been shown to be very promising for gas chromatography separation.

Graphical Abstract

  相似文献   

18.
The authors describe an ethylene glycol assisted precipitation method for synthesis of Er(III)/Yb(III)-doped BiF3 nanoparticles (NPs) at room temperature. Under 980-nm light irradiation, the NPs emit upconversion (UC) emission of Er(III) ions as a result of a two-photon absorption process. The temperature-dependent green emissions (peaking at 525 and 545 nm) are used to establish an unambiguous relationship between the ratio of fluorescence intensities and temperature. The NPs have a maximum sensitivity of 6.5?×?10?3 K?1 at 619 K and can be applied over the 291–691 K temperature range. The results indicate that these NPs are a promising candidate for optical thermometry.
Graphical abstract Schematic of the room-temperature preparation of Er(III)/Yb(III)-doped BiF3 nanoparticles with strongly temperature-dependent upconversion emission.
  相似文献   

19.
The authors describe a highly efficient photoelectrochemical (PEC) scheme for the determination of hydrogen peroxide (H2O2). BiVO4 microrods were hydrothermally synthesized and deposited on fluorine - doped tin oxide (FTO) glass which acts as the working electrode. Scanning electron microscopy, X-ray powder diffraction and Raman spectroscopy were utilized for the characterization of the microrods. On irradiation with visible light, the holes generated in the microrods are capturing electrons from H2O2 to produce a photocurrent at an operating potential of 0 V vs. Ag/AgCl. Under optimal conditions, the photocurrent increases with the concentration of H2O2 in the range from 50 μmol·L?1 to 1.5 mmol·L?1, and the limit of detection is 8.5 μmol·L?1 (at 3σ). A repeatability and intermediate precision of ≤6.6% was accomplished at H2O2 levels of 0.1, 0.5 and 1.0 mmol·L?1. The method was applied to the determination of H2O2 in spiked sterilized milk samples and gave satisfactory results. As the method works at zero potential, the photocurrent can be measured with simple instrumentation such as digital multimeters, and this will enable expensive electrochemical workstations to be replaced in future.
Graphical abstract An enzyme-free photoelectrochemical sensing strategy is described for sensitive determination of hydrogen peroxide in foodstuff using fluorine-doped tin oxide electrode modified with BiVO4 microrods.
  相似文献   

20.
The authors report on the preparation of a hollow-structured cobalt ferrite (CoFe2O4) nanocomposite for use in a non-enzymatic sensor for hydrogen peroxide (H2O2). Silica (SiO2) nanoparticles were exploited as template for the deposition of Fe3O4/CoFe2O4 nanosheets, which was followed by the removal of SiO2 template under mild conditions. This leads to the formation of hollow-structured Fe3O4/CoFe2O4 interconnected nanosheets with cubic spinel structure of high crystallinity. The material was placed on a glassy carbon electrode where it acts as a viable sensor for non-enzymatic determination of H2O2. Operated at a potential of ?0.45 V vs. Ag/AgCl in 0.1 M NaOH solution, the modified GCE has a sensitivity of 17 nA μM?1 cm?2, a linear response in the range of 10 to 1200 μM H2O2 concentration range, and a 2.5 μM detection limit. The sensor is reproducible and stable and was applied to the analysis of spiked urine samples, where it provided excellent recoveries.
Graphical abstract Schematic of a cobalt ferrite (CoFe2O4) hollow structure for use in electrochemical determination of H2O2. The sensor shows a low detection limit, a wide linear range, and excellent selectivity for H2O2.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号