首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new glassy carbon electrode modified with novel calix[4]‐arene derivative was prepared and then applied to the selective recognition of lead ion in aqueous media by cyclic and square wave voltammetry. A new anodic stripping peak at ? 0.92 V (vs. Ag/Ag+) in square wave voltammogram can be obtained by scanning the potential from ? 1.5 to ? 0.6 V, of which the peak current is proportional to the concentration of Pb2+. The modified electrode in 0.1 mol/L HNO3 solution showed a linear voltammetric response in the range of 2.0 × 10–8–1.0 × 10–6 mol/L and a detection limit of 6.1 × 10–9 mol/L. In the modified glassy carbon electrode no significant interference occurred from alkali, alkaline and transition metal ions except Hg2+, Ag+ and Cu2+ ions, which can be eliminated by the addition of KSCN. The proposed method was successfully applied to determine lead in aqueous samples.  相似文献   

2.
A new surface based on poly(vinylferrocenium) (PVF+)-modified platinum electrode was developed for determination of Hg2+ ions in aqueous solutions. The polymer was electrodeposited on platinum electrode by constant potential electrolysis as PVF+ClO4. Cl ions were then attached to the polymer matrix by anion exchange and the modified electrode was dipped into Hg2+ solution. Hg2+ was preconcentrated at the polymer matrix by adsorption and also complexation reaction with Cl. Detection of Hg2+ was carried out by differential pulse anodic stripping voltammetry (DPASV) after reduction of Hg2+. Mercury ions as low as 5 × 10−10 M could be detected with the prepared electrode and the relative standard deviation was calculated as 6.35% at 1 × 10−6 M concentration (n = 6). Interferences of Ag+, Pb2+ and Fe3+ ions were also studied at two different concentration ratios with respect to Hg2+. The developed electrode was applied to the determination of Hg2+ in water samples.  相似文献   

3.
《Electroanalysis》2006,18(12):1202-1207
A new type of current sensor, Langmuir–Blodgett (LB) film of calixarene on the surface of glassy carbon electrode (GCE) was prepared for determination of mercury by anodic stripping voltammetry (ASV). An anodic stripping peak was obtained at 0.15 V (vs. SCE) by scanning the potential from ?0.6 to +0.6 V. Compared with a bare GCE, the LB film coated electrode greatly improves the sensitivity of measuring mercury ion. The fabricated electrode in a 0.1 M H2SO4+0.01 M HCl solution shows a linear voltammetric response in the range of 0.07–40 μg L?1 and detection limit of 0.04 μg L?1 (ca. 2×10?10 M). The high sensitivity, selectivity, and stability of this LB film modified electrode demonstrates its practical application for a simple, rapid and economical determination of Hg2+ in a water sample.  相似文献   

4.
The performance of calix[2]furano[2]pyrrole and related compounds used as neutral carriers for silver selective polymeric membrane electrode was investigated. The silver ion-selective electrode based on calix[2]furano[2]pyrroles gave a good Nernstian response of 57.1 mV per decade for silver ion in the activity range 1×10−6 to 1×10−2 M. The present silver ion-selective electrode displayed very good selectivity for Ag+ ion against alkali and alkaline earth metal ions, NH4+, and H+. In particular, the present Ag+-selective electrode exhibited very low responses towards Hg2+ and Pb2+ ions. The potentiometric selectivity coefficients of the silver ion-selective electrode exhibited a strong dependence on the solution pH. In particular, the response of the electrode to the Hg2+ activity was greatly diminished at pH 2.5 compared to that at pH 5.0. Overall, the performance of the present silver ion-selective electrode based on the ionophore, calix[2]furano[2]pyrrole, is very comparable to that of the electrode prepared with the commercially available neutral carrier in terms of slope, linear range, and detection limits.  相似文献   

5.
Fluorescent chemosensor 3 can sense Cu2+ ions (1-8 μM) even in the presence of elevated levels of Ni2+, Cd2+, Zn2+, Hg2+, Ag+ and Pb2+ (5000 μM). 3 can also analyze for Ag+ ions (50-500 μM) in the presence of Ni2+, Cd2+, Zn2+, Hg2+ and Pb2+ (5000 μM) but Cu2+ strongly interferes.  相似文献   

6.
Zusammenfassung Die Trennung und Isolierung von folgenden Schwermetallen bei einem hohen Überschuß an Fremdionen mit Hilfe neuer selektiver Chelataustauscher wird beschrieben: Cu2+/Zn2+, Cu2+/Pb2+, Ag+/Cu2+, Ag+/Pb2+, Hg2+/Zn2+, Hg2+/Cd2+; Abtrennung von Hg2+. Unter gleichen Bedingungen war mit dem handelsüblichen Austauscher Dowex A-1 keine Trennung möglich.
Quantitative separation of heavy metals by means of chelating exchangers based on polystyrol
Summary The separation and isolation of the following heavy metals in presence of a high excess of foreign ions by means of new selective chelating exchangers is described: Cu2+/Zn2+, Cu2+/Pb2+, Ag+/Cu2+, Ag+/Pb2+, Hg2+/Zn2+, Hg2+/Cd2+; separation of Hg2+. Under the same conditions no separation could be achieved by the ion-exchanger Dowex A-1.
  相似文献   

7.
A novel calix[4]arene derivative containing benzothiazole azo groups at the upper rim was synthesized as chromogenic chemosensor, and its binding and sensing properties with heavy metal ions (Pb2+, Hg2+, Ni2+, Cd2+, Cu2+, Zn2+, Co2+, Fe2+, Mn2+, Cr3+, Ag+) were investigated by UV-vis spectroscopy and voltammetric techniques. The results of spectroscopic and voltammetric experiments showed that the chromogenic chemosensor has high selectivity towards Hg2+ ion over the other heavy metal ions. Moreover, it was shown that the interaction between Hg2+ and the chromogenic chemosensor occurs by means of the benzothiazole azo groups at the upper rim by using differential pulse voltammetry. The stoichiometric ratio and the association constant were determined as 1:1 and (6.1 ± 0.3) × 105 L mol−1 for the complex between Hg2+ and the ionophore. Furthermore, we prepared a rapid test kit for early detection of Hg2+ in aqueous environment in the concentration range of 1 × 10−4 to 1 × 10−2 M.  相似文献   

8.
Two new indole derivatives have been synthesized by a one-pot procedure and their potential as fluorescence probes for metal ions was investigated. The sensor capability of 1 and 2 toward cations such as Ag+, Cu2+, Zn2+, Cd2+, Pb2+, and Hg2− was studied in dichloromethane solution by absorption, fluorescence emission, and 1H NMR titrations. Both probes showed selectivity for Ag+ and Hg2+ ions. The results suggest that these compounds may serve as promising models for future design of novel and more potent sensors.  相似文献   

9.
A new chelating resin containing bis[2-(2-benzothiazolylthioethyl)sulfoxide] was synthesized using chloromethylated polystyrene as material and characterized by elemental analysis and infrared spectra. The adsorption capacities of the newly formed resin for Hg2+, Ag+, Cu2+, Zn2+, Pb2+, Mn2+, Ni2+, Cd2+ and Fe3+ were investigated over the pH range 1.0-6.0. The resin exhibited no affinity for alkali or alkaline earth metal ions. The maximum adsorption capacities of the resin for Hg2+, Ag+, Cu2+, Zn2+, Pb2+, Mn2+, Ni2+, Cd2+ and Fe3+ were 1.49, 0.96, 0.58, 0.11, 0.37, 0, 0.24, 0.36 and 0.25 mmol g−1, respectively. In column operation it had been observed that Hg2+ and Ag+ in trace quantity could be separated from different binary mixtures and Hg2+ could be effectively removed from industrial wastewater and the natural water spiked with Hg2+ at usual pH.  相似文献   

10.
A solid state copper(II) ion sensor is reported based on the application of electropolymerized undoped (neutral) polycarbazole (PCz) and polyindole (PIn) modified electrodes. The new sensor shows high selectivity to Cu2+ ions with a detection limit of 10–5 M. PCz and PIn are formed respectively by the anodic oxidation of 50 mM carbazole and 5 mM indole monomers in dichloromethane containing 0.1 M tetrabutylammonium perchlorate on a platinum electrode using a single compartment cell. Potentiostatic polymerization of both the monomers are carried out at 1.3 V and 1.0 V vs. Ag/AgCl, respectively. Perchlorate ions were electrochemically removed from the polymer films by applying – 0.2 V vs. Ag/AgCl. Polymer-coated electrodes are incubated in 1 M KCl solution for 8 h followed by incubation in distilled water for 2 h before using as a metal ion sensor. The undoped PCz and PIn electrodes were found to be highly selective and sensitive for Cu2+ ions with little selectivity for Pb2+ and negligible response towards Ag+, Hg2+, Cu+, Ni2+, Co2+, Fe2+, Fe3+ or Zn2+. Potentiometric responses for Cu2+ ions are recorded for both the sensor electrodes together with a double-junction Ag/AgCl reference electrode. Calibration curves for Cu2+ are reported for both ion sensors. The polymer-modified electrodes were found to be stable for several weeks. Electronic Publication  相似文献   

11.
We demonstrate a new material by intercalating Mo3S132? into Mg/Al layered double hydroxide (abbr. Mo3S13-LDH), exhibiting excellent capture capability for toxic Hg2+ and noble metal silver (Ag). The as-prepared Mo3S13-LDH displays ultra-high selectivity of Ag+, Hg2+ and Cu2+ in the presence of various competitive ions, with the order of Ag+>Hg2+>Cu2+>Pb2+≥Co2+, Ni2+, Zn2+, Cd2+. For Ag+ and Hg2+, extremely fast adsorption rates (≈90 % within 10 min, >99 % in 1 h) are observed. Much high selectivity is present for Ag+ and Cu2+, especially for trace amounts of Ag+ (≈1 ppm), achieving a large separation factor (SFAg/Cu) of ≈8000 at the large Cu/Ag ratio of 520. The overwhelming adsorption capacities for Ag+ (qmAg=1073 mg g?1) and Hg2+ (qmHg=594 mg g?1) place the Mo3S13-LDH at the top of performing sorbent materials. Most importantly, Mo3S13-LDH captures Ag+ via two paths: a) formation of Ag2S due to Ag-S complexation and precipitation, and b) reduction of Ag+ to metallic silver (Ag0). The Mo3S13-LDH is a promising material to extract low-grade silver from copper-rich minerals and trap highly toxic Hg2+ from polluted water.  相似文献   

12.
《Analytical letters》2012,45(14):2327-2343
Abstract

A novel approach for the voltammetric determination of Pb2+, Cu2+, and Hg2+ in the presence of macromolecule contaminants was developed. An Au nanoparticles array was directly electrodeposited onto the gold electrode surface followed by a further modification of a mercaptoethanesulfonate (MES) monolayer. Square wave stripping voltammetry (SWSV) of Pb2+, Cu2+, and Hg2+ was performed on the doubly modified electrode. The electrodeposited gold nanoparticles provided a significantly improved sensitivity. Simultaneously, the MES monolayer efficiently prevented the macromolecules accessing the electrode surface. Compared with the bare gold electrode, the doubly modified electrode has the ability to detect metal ions in the presence of macromolecule contaminants, even when their concentration reach 100 ppm. Under the optimal conditions, the detection limits of 0.16, 0.15, and 0.14 ppb for Pb2+, Cu2+, and Hg2+ were obtained, respectively. The calibration graphs were linear in the concentration range of 1–100 ppb. The results of the analysis of a real metallurgy wastewater sample were reported. The electrode system has a great potential for the direct determination of trace metals in the complex environment and biological samples.  相似文献   

13.
Gao J  Chen H  Dai H  Lv D  Ren J  Wang L  Yang W 《Analytica chimica acta》2006,571(1):150-155
A highly sensitive method for the determination of trace amounts of transition metal ions by use of sulfide in the Belousov-Zhabotinskii (B-Z) oscillating chemical reaction is proposed. The use of sulfide increased strongly the sensitivity of the B-Z reaction for transition metal ions, such as Ag+, Pb2+, Hg2+, Cd2+, Cu2+,and Bi3+. Results showed that the variational ratio of oscillating period (PR) is linearly proportional to the negative logarithm of concentration of metal ions. The detection limit is down to 10−12 mol L−1. Various influencing factors on the determination were also examined.  相似文献   

14.
A novel capillary with high sensitivity and selectivity for mercury ion detection based on modified nanosize silica has been designed and synthesized. The obtained modified capillary was applied to separate and determine mercury ion by capillary electrophoresis with a laser‐induced fluorescence detector. The optimal experimental conditions were determined by evaluating various controlling factors: running buffer hexamine‐HCl 15 mmol L?1, pH=5.2, separation voltage 30 kV and temperature 25 °C. The modified capillary exhibited excellent sensitivity and selectivity for Hg2+ over other coexisting metal ions (K+, Ag+, Ca2+, Mg2+, Ba2+, Ni2+, Cd2+, Pb2+ and Zn2+ increased to 10000 times of Hg2+, Cu2+ increased to 5000 times) in aqueous solution, and was successfully applied to the determination of Hg2+ in natural water samples and displayed satisfactory results.  相似文献   

15.
The complexation reaction of dibenzopyridino-18-crown-6 (DBPY 18C6) with Co2+, Cu2+, Zn2+, Pb2+, Cd2+, Hg2+, and Ag+ have been studied in DMSO at 25°C by the spectrophotometric method. Murexide was used as a competitive colored ligand. The stoichiometry of metal ion-murexide and metal ions with DBPY18C6 complexes were estimated by mole ratio and continuous variation methods and emphasized by the KINFIT program. The stoichiometry of all the complexes was found to be 1: 1 (metal ion/ligand). The order of stability constants for the obtained metal ion-murexide complexes (1: 1) varies in the order Cu2+ > Cd2+ > Co2+ ∼ Pb2+ > Zn2+ > Ag+ > Hg2+. This trend shows that the transition metal ions clearly obey the Irving-Williams role. For the post-transition metal ions, the ionic radius and soft-hard behavior was the major affects in varying of this order. The dibenzopyridino-18-crown-6 complexes with the used metal ions vary as Ag+ > Pb2+ > Cu2+ > Cd2+ > Hg2+ > Zn2+ > Co2+. The article is published in the original.  相似文献   

16.
Zeng B  Ding X  Pan D  Zhao F 《Talanta》2003,59(3):501-507
Silver ions can be entrapped at the dl-dithiothreitol (HSCH2(CHOH)2CH2SH, DTT) self-assembled monolayer films modified gold electrodes. When the potential was made moving, an anodic peak was observed at about 0.23 V (vs. SCE). When the electrode Au/DTT was modified with dodecyl mercaptan further, more Ag (I) can be accumulated and the peak grows. Conditions, such as solution pH and supporting electrolyte, were optimized for Ag (I) determination. Under the selected conditions, i.e. 0.010 M pH 4.3 potassium hydrogen phthalate, preconcentration time of 5 min at open circuit, the anodic peak height is linear to the concentration of Ag (I) in the small range of 0.6-2.4 μM. The influence of some ions on the determination of Ag (I) was examined. The Br ion makes the peak decrease and NCS makes the peak increase. But the determination is not interfered by 1000-fold Pb2+, Cd2+, Hg2+, Fe3+, Ni2+, Co2+, Cu2+ and Sn2+ when EDTA was added into the solution. The mechanism involved was discussed.  相似文献   

17.
In the present paper, we used single-stranded poly-T (100% thymine bases) and poly-C (100% cytosine bases) nucleic acids as DNA probes for selective and sensitive individual electrochemical determination of Hg2+ and Ag+, respectively, on the multi-walled carbon nanotube paste electrodes (MWCNTPEs) using [Fe(CN)6]3?/4? as electroactive labels. In the presence of Hg2+ and Ag+, the probe–Hg2+/Ag+ interactions through T–Hg2+–T and C–Ag+–C complexes formation could cause the formation of a unimolecular hybridized probe. This structure of probe led to its partial depletion from electrode surface and facilitation of electron transfer between [Fe(CN)6]3?/4? redox couple and electrode surface, resulting in the enhanced differential pulse voltammetry (DPV) oxidation current of [Fe(CN)6]3?/4? at the probe-modified electrode surface. We applied the difference in the oxidation peak currents of [Fe(CN)6]3?/4? before and after Hg2+/Ag+–DNA probe bonding (?I) for electrochemical determination of these heavy metal ions. Detection limits were 8.0?×?10?12 M and 1.0?×?10?11 M for Hg2+ and Ag+ ions determination, respectively. The biosensors were utilized to determine the weight percent of toxic metals, i.e., silver and mercury in dental amalgam filling composition. The results of their practical applicability in analysis of the amalgam sample were satisfactory.  相似文献   

18.
The fast chemiluminescence (CL) arising from the reaction of bis(2,4,6-trichlorophenyl)oxalate (TCPO) with hydrogen peroxide in the presence of 1-(dansylamidopropyl)-1-aza-4,7,10-trithiacyclododecane (L) as a novel fluorophore, and imidazole as catalyst, has been studied in ethyl acetate solution. The relationships between the chemiluminescence intensity and concentrations of TCPO, imidazole, hydrogen peroxide and L are reported. In the presence of imidazole as catalyst, the entire CL signal was completed in less than 3 s. The quenching effect of Cu2+, Pb2+, Cd2+, Hg2+ and Ag+ ions on the chemiluminescent system was investigated, the resulting Stern–Volmer plots were obtained and the KQ values were calculated. It was found that the quenching effect of metal ions on the chemiluminescence of L decreases in the order Cu2+ > Pb2+ > Cd2+ > Hg2+ > Ag+.  相似文献   

19.
《Electroanalysis》2017,29(9):2090-2097
Lignosulfonate‐stabilized gold nanoparticles (AuNPs‐LS) were synthesized and subsequently used as a complexing agent for mercury ions. The obtained AuNPs‐LS/Hg2+ complex was characterized by means of various physicochemical techniques such as UV‐vis spectroscopy, transmission electron microscopy and cyclic voltammetry. Furthermore, the resulting complex was evaluated as an electrode modifier for the development of amperometric sensors. Upon sufficient negative potential, the bound mercury ions are reduced to form an amalgam with AuNPs‐LS. Thus, the performance of glassy carbon electrode (GCE) modified by AuNPs‐LS/Hg film was investigated as an electrochemical sensor in the determination of Tl+ ions in a 0.05 M EDTA at pH 4.5. The presence of the mercury containing film improves the analyte accumulation due to its ability to form a fused amalgam with thallium. The presented data indicate that the GCE/AuNPs‐LS/Hg modified electrode shows better performance toward Tl+ determination in comparison to bare GCE. The stripping anodic peak current of thallium was linear over its concentration range from 1.7⋅10−7 to 5.0⋅10−6 M. The detection limit (3σ) was estimated to be 1.4⋅10−7 M. The proposed method was successfully applied for the determination of thallium ions in real samples of soil derived from the area of the copper smelter near Głogów (Poland).  相似文献   

20.
A novel fluorometric sensor bearing three dansyl moieties based on tris[2-(2-aminoethylthio)ethyl]amine was prepared by a simple approach using a conventional two-step synthesis. The sensor exhibits highly Hg2+-selective ON-OFF fluorescence quenching behavior in aqueous acetonitrile solutions and is shown to discriminate various competing metal ions, particularly Cu2+, Ag+, and Pb2+ as well as Ca2+, Cd2+, Co2+, Fe3+, Mn2+, Na+, Ni2+, and Zn2+, with a detection limit of 1.15 × 10−7 M or 23 ppb.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号