Various plutonium compounds are handled in nuclear facilities of BARC. Hence, there is a possibility of occupational workers getting exposed to Pu. In vitro bioassay monitoring in which Pu is separated by chemical procedures from excreta samples and estimated by alpha-spectrometry, is the method of choice for the evaluation of internal dose to the occupational workers handling Pu. However, this method requires a suitable Pu tracer for reducing the uncertainties due to chemical yield in the separation, electro-deposition and counting efficiency. 242Pu is commonly used as a tracer but due to its non-availability, efforts were made earlier to indigenously synthesis 236Pu by proton irradiation of 237Np in BARC-TIFR pelletron facility. The present study, reports the feasibility of using 236Pu as a radiochemical yield monitor (tracer) in bioassay samples.  相似文献   

2.
The conventional method used for estimation of Pu-isotopes in urine samples involves anion exchange resin followed by alpha spectrometry, which takes nearly one working week for complete sample analysis. Since the results of the analysis form an important input for decision making by the plant authorities, it is always preferable to reduce overall analysis time for the estimation of Pu-isotopes in bioassay samples. This paper deals with standardization of a relatively faster method for estimation of Pu-isotopes in bioassay samples using TEVA resin and 236Pu tracer for radiochemical recovery. The method involves oxidation of urine followed by co-precipitation of plutonium along with calcium phosphate and separation of Pu was carried out using TEVA resin. Pu-fraction was electrodeposited and activity estimated using tracer recovery by alpha spectrometer. Routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 65–87 % with a mean and SD of 75 and 7.4 %, respectively. The standardized chromatographic technique reduces the analysis time by about 1 day as compared to conventional method for estimation of Pu-isotopes in urine samples.  相似文献   

3.
Bioassay technique is used for the estimation of actinides present in the body based on their excretion rate through body fluids. For occupational radiation workers urine assay is the preferred method for monitoring of chronic internal exposure. Determination of low concentrations of actinides such as plutonium, americium and uranium at low level of mBq in urine by alpha spectrometry requires pre-concentration of large volumes of urine. This paper deals with standardization of analytical method for the determination of Pu-isotopes in urine samples using anion exchange resin and 236Pu tracer for radiochemical recovery. The method involves oxidation of urine followed by co-precipitation of plutonium along with calcium phosphate. Separation of Pu was carried out by Amberlite, IRA-400, anion exchange resin. Pu-fraction was electrodeposited and activity estimated using tracer recovery by alpha spectrometer. Twenty routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 74–96% with a mean and standard deviation of 85 and 6% respectively.  相似文献   

4.
A procedure for determining Pu in environmental soil using238Pu as a yield tracer is described. The method involves radiochemical separation and electrodeposition onto a stainless steel disc followed by alpha-spectrometric measurement with a solid-state detector. In order to eliminate error in calculation caused by238Pu contained in original samples, a new calculating method is introduced in this paper. By using this method, the activity of238Pu contained in original samples can be substracted from the total activity of samples, to which the238Pu tracer is added. This procedure has been applied satisfactorily to the determination of Pu in a soil reference sample, which was supplied by the Institute of Metrological Science of China.  相似文献   

5.
A combination of alpha-spectrometry, liquid scintillation counting (LSC) and accelerator mass spectrometry (AMS) was used for the determination of plutonium isotopes. 238Pu and 239+240Pu were measured by alpha-spectrometry after separation of Pu by anion-exchange using 236Pu tracer as recovery monitor. After alpha-measurement, one part of the sample was dissolved for determining 241Pu by LSC. Another part was used for the measurement of the 240Pu/239Pu atom ratio by AMS at VERA. Thus, it was possible to obtain complete information on the Pu isotopic composition of the samples. This method was applied to environmental reference samples and samples contaminated from nuclear reprocessing.  相似文献   

6.
The aim of this paper is to clearly define the chemical and nuclear principles governing Fission Track Analysis (FTA) to determine environmental levels of239Pu in urine. The paper also addresses deficiencies in FTA methodology and introduces improvements to make FTA a more reliable research tool. Our refined methodology, described herein, includes a chemically-induced precipitation phase, followed by anion exchange chromatography and employs a chemical tracer,236Pu. We have been able to establish an inverse correlation between Pu recovery and sample volume and our data confirms that increases in sample volume do not result in higher accuracy or lower detection limits. We conclude that in subsequent studies, samples should be limited to approximately two liters. The Pu detection limit for a sample of this volume is 2.8 μBq/l.  相似文献   

7.
A simple, rapid and reliable method was developed for the simultaneous determination of uranium and plutonium isotopes by alpha-spectrometry using a single source. A new uranium tracer230U was applied as well as the236Pu tracer to determine overall yields of uranium and plutonium isotopes throughout the entire procedure employed. The analytical procedure consists of sample leaching with 8N HNO3 solution, purification by solvent extraction, simultaneous electrodeposition of U and Pu, and subsequent alpha-spectrometry with a silicon detector. In the solvent extraction using TOA/xylene from 8N HNO3 solution, the preferential extractability of Pu rather than U permits to purify simultaneously the trace amounts of Pu and the macro amounts of U, as in the case of ordinary soil samples, resulting in favourable peak heights for both isotopes. From a single alpha-spectrum, the determinations of238U,234U (and their ratio of234U/238U),239+240Pu, and238Pu contents were conveniently carried out after correcting the overall yields obtained from230U and236Pu activities in the same spectrum. This analytical method was satisfactorily applied to the determination of U and Pu isotope contents in some soils.  相似文献   

8.
Summary A new high-sensitivity plutonium bioassay program employing thermal ionization mass spectrometry (TIMS) has been developed to monitor Savannah River Site employees for intakes of PuO2. The U.S. Department of Energy requires bioassay laboratories which have the ability to detect a 100 mRem, 50-year committed effective dose equivalent (CEDE) intake of radioactive material. For PuO2, traditional alpha-spectrometry methods are not sensitive enough to meet this specification. To comply with this requirement, a radiochemical TIMS method was developed to determine Pu in urine bioassay samples. Four radiochemical separation steps were used to purify Pu from urine to ensure samples were free from matrix effects that interfere with TIMS analysis. These included precipitation, ion-extraction chromatography, electrodeposition, and ion-exchange chromatography. A batch of reagent blanks determined the detection limit for this method was 0.59 fg 239Pu/l (1.3 µBq 239Pu/l). The 239Pu concentration was also measured in 20 urine blank samples to determine the minimum 239Pu concentration that would indicate an occupational intake. A Probit plot was constructed for the results and the 99 th percentile of the urine blanks showed that the minimum 239Pu concentration that would indicate an uptake was 2.4 fg/l (5.5 µBq/l).  相似文献   

9.
Qiao J  Hou X  Roos P  Miró M 《Talanta》2011,84(2):494-500
This paper reports an analytical method for rapid determination of neptunium (237Np) in environmental solid samples exploiting automated sequential injection (SI)-based anion exchange separation. Pivotal issues on analytical method performance were investigated including sorption behavior of 237Np onto various AG 1-type anion exchangers; suitability of 242Pu as a tracer for 237Np determination in environmental solid samples; and long-term chemical stability of tetravalent Np. Experimental results revealed that the degree of resin cross-linking has a significant influence on the separation efficiency in terms of chemical yields of 237Np and removal of interfering nuclides. Although ca. 30% of sorbed Np onto AG 1-×4 was stripped out during HCl rinsing step for the removal of Th, chemical yield ratios of 237Np to 242Pu were proven steady with an average value of 0.67 ± 0.04 (n = 15) under selected experimental conditions. Disulfite-8 M HNO3 was selected as a redox pair for valence adjustment to Np(IV) and the tetravalent Np in the sample solution was demonstrated to be stabilized for up to 5 days under 3 °C. The analytical results for reference materials showed a good agreement with the expected values, thereby demonstrating the usefulness of 242Pu as a non-isotopic tracer for 237Np chemical yield monitoring. The on-column separation procedure fosters rapid analysis as required in emergency situations since each individual sample can be handled within 2.5 h, and leads to a significant decrease in labor intensity compared to conventional batch-wise protocols.  相似文献   

10.
A new rapid separation method that allows separation and preconcentration of actinides in urine samples was developed for the measurement of longer lived actinides by inductively coupled plasma mass spectrometry (ICP-MS) and short-lived actinides by alpha spectrometry; a hybrid approach. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration, if required, is performed using a streamlined calcium phosphate precipitation. Similar technology has been applied to separate actinides prior to measurement by alpha spectrometry, but this new method has been developed with elution reagents now compatible with ICP-MS as well. Purified solutions are split between ICP-MS and alpha spectrometry so that long- and short-lived actinide isotopes can be measured successfully. The method allows for simultaneous extraction of 24 samples (including QC samples) in less than 3 h. Simultaneous sample preparation can offer significant time savings over sequential sample preparation. For example, sequential sample preparation of 24 samples taking just 15 min each requires 6 h to complete. The simplicity and speed of this new method makes it attractive for radiological emergency response. If preconcentration is applied, the method is applicable to larger sample aliquots for occupational exposures as well. The chemical recoveries are typically greater than 90%, in contrast to other reported methods using flow injection separation techniques for urine samples where plutonium yields were 70-80%. This method allows measurement of both long-lived and short-lived actinide isotopes. 239Pu, 242Pu, 237Np, 243Am, 234U, 235U and 238U were measured by ICP-MS, while 236Pu, 238Pu, 239Pu, 241Am, 243Am and 244Cm were measured by alpha spectrometry. The method can also be adapted so that the separation of uranium isotopes for assay is not required, if uranium assay by direct dilution of the urine sample is preferred instead. Multiple vacuum box locations may be set-up to supply several ICP-MS units with purified sample fractions such that a high sample throughput may be achieved, while still allowing for rapid measurement of short-lived actinides by alpha spectrometry.  相似文献   

11.
A critical review is presented of bioassay techniques for actinides in light of ICRP recommendations for monitoring workers. It is obvious that very sensitive techniques are required to meet these recommendations. Alpha spectrometry, the most commonly employed technique for measuring actinides in bioassay samples, has limited sensitivity. There are, however, certain techniques which are sensitive enough to meet the recommendations of ICRP, such as, fission track analysis for239Pu and235U, neutron activation analysis for232Th, mass spectrometry for a number of radionuclides, and many techniques for uranium. ICP-mass spectrometry does not have enough sensitivity to be implemented as a method of choice for the bioassay of actinides at present, however, it is quite promising.  相似文献   

12.
Very low levels of plutonium (239,240Pu and 238Pu) in marine samples (sea water,sediments, marine organisms) are determined by extraction on columns of tri-n-octyl phosphine oxide supported on microporous polyethylene (Micro thene-710), electrode- position, and α-spectrometry. 236Pu or 242Pu is added as the yield detector and a high-resolution α-spectrometer is used for counting. The final recoveries are 62.6% ± 9.7(σ)for sea water, 45.4% ± 9.6(0) for sediments and 81.7%± 4.5(σ) for marine organisms. Themethod enables 239.240pu and 238Pu to be detected at the femtocurie level.  相似文献   

13.
Primary coolant samples from a research have been analyzed for239,240Pu,238Pu,238U,237Np and239Np. The determination of237Np and238U was carried out with the help of isotope dilution neutron activation analysis with239Np or238Np as tracer. For determination of239,240Pu and238Pu alpha spectroscopic isotope dilution analysis with238Pu as tracer was used.239Np was determined with the help of isotope dilution analysis using238Np as tracer. Nuclides were isolated by chemical separation on anionite resin. Before measurement, Pu isotopes were electrolytically deposited on stainless steel plates. Activity ratios referred to238U were reported. They are helpful for identification of the sources of actinide activity in reactor effluents.  相似文献   

14.
The age of plutonium is defined as the time since the last separation of the plutonium isotopes from their daughter nuclides. In this paper, a method for age determination based on analysis of 241Pu/241Am and 240Pu/236Pu using ICP-SFMS is described. Separation of Pu and Am was performed using a solid phase extraction procedure including UTEVA, TEVA, TRU and Ln-resins. The procedure provided separation factors adequate for this purpose. Age determinations were performed on two plutonium reference solutions from the Institute for Reference Materials and Measurements, IRMM081 (239Pu) and IRMM083 (240Pu), on sediment from the Marshall Islands (reference material IAEA367) and on soil from the Trinity test site (Trinitite). The measured ages based on the 241Am/241Pu ratio corresponded well with the time since the last parent-daughter separations of all the materials. The ages derived from the 236U/240Pu ratio were in agreement for the IRMM materials, but for IAEA367 the determination of 236U was interfered by tailing from 238U, and for Trinitite the determined age was biased due to formation of 236U in the detonation of the “Gadget”.  相似文献   

15.
A highly selective method is described for the determination of 239,240Pu and 238Pu in soils by extraction chromatography with Microthene-710/tri-n-octylamine. The method is especially suitable for volcanic soils containing high concentrations of natural alpha radionuclides (Th, Po, U, etc.). The detection limit by α-spectrometry is 2.2 mBq kg?1 for 50-g soil samples. The average chemical yield, obtained by adding 242Pu as the internal standard, is 69.5 ± 17.1%. An IAEA reference soil was analyzed, with a relative error of 6.7% for 239Pu. The concentration of 2239,240Pu in thirteen analyzed soils and sediments ranged from 26.6 to 429 mBq kg?1.  相似文献   

16.
A new method that allows rapid preconcentration and separation of plutonium and neptunium in water samples was developed for the measurement of 237Np and Pu isotopes by inductively-coupled plasma mass spectrometry (ICP-MS) and alpha spectrometry. 238U can interfere with 239Pu measurement by ICP-MS as 238UH+ mass overlap and 237Np via peak tailing. The method provide enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then moving Pu to DGA resin for additional removal of uranium. The decontamination factor for uranium from Pu is almost 100,000 and the decontamination factor for U from Np is greater than 10,000. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration is performed using a streamlined calcium phosphate precipitation method. Purified solutions are split between ICP-MS and alpha spectrometry so that long and short-lived Pu isotopes can be measured successfully. The method allows for simultaneous extraction of 20 samples (including QC samples) in 4?C6 h, and can also be used for emergency response. 239Pu, 242Pu and 237Np were measured by ICP-MS, while 236Pu, 238Pu, and 239Pu were measured by alpha spectrometry.  相似文献   

17.
Analysis of the artificial radionuclide 99Tc in environmental samples requires a chemical separation due to its low concentration, and therefore the use of a chemical yield tracer is peremptory. From a practical viewpoint, Re can be used for this purpose, due to its chemical similarities with Tc. Thus, the use of a radioactive tracer for Tc recovery calculation can be avoided. However, results from a recent intercomparison exercise showed that using of Re as a chemical yield tracer appears to underestimate the Tc concentration relative to the result obtained with isotopes of Tc. In the present work, the methodology used to design a simple separation method for the measurement of 99Tc in environmental samples is described. Tc recovery is estimated throughout the Re recovery calculation by the isotope dilution technique coupled with ICP-MS (ID-ICP-MS) technique. For chemical separation, a chromatographic resin is used. Interfering elements are removed using a resin washing step carefully designed to avoid any element fractionation between Re and Tc; the care taken in this step is of major importance to assure the equivalence of the chemical recoveries for both elements. Agreement is tested using five replicates of five seaweed samples. The average recoveries for 95mTc and Re were 93±6 and 95±7%, respectively, those are within the uncertainty intervals for each other. The results explained here demonstrate the possibility of applying Re chemical recoveries to calculate the Tc concentrations with the advantage of not introducing systematic errors.  相似文献   

18.
The electrodeposition of Pu and Am onto stainless steel discs from 3.2M ammonium chloride solution is strongly affected by the iron concentration of the electrolyte. At Fe(III) concentrations of more than 0.1mM (30 g Fe in 5 ml) only 30–40% of236Pu and 6% of241Am can be deposited. Tracer experiments with59Fe suggest that exchange processes take place between Fe from the surface layer of the cathode and from the electrolyte. Double tracer studies show increasing236Pu/59Fe- and decreasing241Am/59Fe-ratios with increasing iron content of the electrolyte, which may be due to different sorption properties on colloidal iron hydroxides formed at pH<3.6.  相似文献   

19.
An isotopic dilution method is described for the determination ot plutonium in samples of irradiated uranium using a 242Pu tracer. An aliquot of tracer is added to the sample and the mixture treated to ensure isotopic exchange; plutonium is then separated by an ion exchange procedure and an isotopic analysis made using an M.S.5. mass spectrometer. The precision (3 σ) for an aliquot containing 0.1 μg plutonium is 0.6%. A possible application of the method would be its use for control analyses of the feed solution in a chemical plant processing natural uranium fuel elements as, for example, the Windscale primary separation plant.  相似文献   

20.
Bioassay technique is used for the estimation of actinides present in the body based on the excretion rate of body fluids. For occupational radiation workers urine assay is the preferred method for monitoring of chronic internal exposure. Determination of low concentrations of actinides such as plutonium, americium and uranium at low level of mBq in urine by alpha-spectrometry requires pre-concentration of large volumes of urine. This paper deals with standardization of analytical method for the determination of U-isotopes in urine samples using anion-exchange resin and 232U tracer for radiochemical recovery. The method involves oxidation of urine followed by co-precipitation of uranium along with calcium phosphate. Separation of U was carried out by Amberlite, IRA-400, anion-exchange resin. U-fraction was electrodeposited and activity estimated using tracer recovery by alpha-spectrometer. Eight routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range of 51% to 67% with a mean and standard deviation of 60% and 5.4%, respectively.  相似文献   