首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
The use of electrospray ionisation Fourier-transform ion cyclotron resonance tandem mass spectrometry (ESI-FTICR-MS/MS) for the analysis of dynamic combinatorial libraries (DCLs) of pseudo-peptide macrocyclic hydrazone oligomers is presented. The design of library building blocks results in mixtures of compounds with greater diversity than libraries generated by conventional combinatorial chemistry and so presents increased demands for analysis. The extended capabilities of the FTICR technique, specifically selective ion trapping, sensitivity, high resolution and mass accuracy over a broad mass range, are compatible with these increased demands and, most importantly, without the need for chromatography. Preliminary studies on the sequencing of cyclic oligomers and confirmation of the presence of sequence isomers are presented. These studies highlight the potential of FTICR-MS as a superior technique for the analysis of combinatorially generated compounds.  相似文献   

2.
We report high resolution spectra for the medium molecular weight proteins myoglobin and cytochrome-c obtained using a custom desorption electrospray ionisation (DESI) source coupled to a Bruker Daltonics 12 T Apex Qe Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS). The DESI source was designed for accurate alignment and reproduction of critical geometric variables. A two axis motorised stage was included to enable automated rastering of the sample under the DESI plume. Spectra for the intact proteins have been obtained under single-acquisition conditions and a top-down analysis of cytochrome-c was performed using both collision induced dissociation (CID) and electron capture dissociation (ECD) of the isolated [M+15H]15+ charge state. The sequence coverage is comparable to that obtained using electrospray ionisation, demonstrating the utility of top-down protein analysis by DESI FTICR-MS.  相似文献   

3.
Mass spectral libraries provide a tool for identifying unknown compounds using both molecular weight and fragmentation information. Mass spectrometers with electrospray ionisation (ESI) and atmospheric chemical ionisation (ApCI) sources have the capability to produce data of this type using in-source collisionally induced dissociation (CID), and in-source CID libraries can be created. Due to the variation in electrospray source design from different instrument manufacturers, the production of reproducible in-source CID spectra that can be used in libraries for all instrument types is not a trivial task. To date, the evaluation of the production of in-source CID libraries has tended to focus on similar instruments from one manufacturer. The studies have also tended to focus on specific compound classes, with a limited molecular weight range.This report describes the findings from the investigation of protocols for the creation of mass spectral libraries using ESI in-source CID on six instruments from four different manufacturers. The overall goal was to create a spectral library for the identification of unknowns. The library could then be applied across all manufacturers' electrospray instruments.Two different experimental protocols were attempted. The first used a tuning compound to establish standard ESI source conditions, with fixed fragmentation potentials. The second involved the attenuation of the [M + H](+) ion to a known degree. A diverse range of compounds (pharmaceutical, photographic, pesticides) was tested to establish the reproducibility of the spectra on the six instruments. Both protocols produced spectra on the various instruments that in many cases were very similar. In other examples, the spectra differed not only in their relative ion abundances, but also in terms of the spectral content. Important observations regarding the effect of ion source design are also reported.The degree of spectral reproducibility was calculated off-line by comparing the five most abundant ions (20% for each ion that matches) from each spectrum on each instrument. This approach was adopted, as we do not possess a software package that met our requirements for spectral comparison. Match factors (% fit) were calculated by comparing each spectrum against the spectra recorded for the same compound and then for all other compounds, on each instrument. The % fit values derived by the off-line approach gave a clear view of the spectral reproducibility from instrument to instrument and also discriminated the spectra of the various compounds from each other. The applicability of this approach was tested using a blind trial in which several compounds were presented as unknowns, their in-source CID spectra recorded and the five-ion approach used for identification.  相似文献   

4.
A new method for the simultaneous qualitative and quantitative determination of alkyl benzyl and dialkyl quaternary ammonium compounds (QACs) has been developed. Analysis is by reversed-phase high-performance liquid chromatography coupled with electrospray ionisation mass spectrometry. QACs are extremely amenable to the electrospray ionisation technique (limit of detection of BAC C12 homologue 3 ng ml(-1)). The selectivity of mass spectrometric detection allows simultaneous determination of benzyl and dialkyl dimethyl ammonium compounds. The method was successfully applied to the analysis of real samples (occupational hygiene sampling devices, products and swimming pool water). Structural information was obtained by MS-MS and cone voltage ion dissociation techniques. Ion dissociation enabled the structural elucidation of an unknown quaternary ammonium compound present in a commercial formulation.  相似文献   

5.
A novel strategy was developed to extend the application of electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) to the analysis of long-chain polysaccharides. High molecular weight polydisperse maltodextrins (poly-alpha(1-4) glucose) and dextrans (poly-alpha(1-6) glucose) were chosen as model compounds in the present study. Increased ionization efficiency of these mixtures in the positive ion mode was achieved upon modification of their reducing end with nitrogen-containing groups. The derivatization method is based on the formation of a new C--N bond between 1,6-hexamethylenediamine (HMD) and the reducing end of the polysaccharide, which exists in solution as an equilibrium between the hemiacetal and the open-ring aldehyde form. To achieve the chemical modification of the reducing end, two synthetic pathways were developed: (i) coupling of HMD by reductive amination and (ii) oxidation of the hemiacetal to lactone, followed by ring opening by HMD to yield the maltodextrin lactonamide of 1,6-hexanediamine (HMMD). Amino-functionalized polysaccharides were analyzed by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FTICR-MS) in the positive ion mode by direct flow injection. The hexamethylenediamine (HMD) and maltodextrin lactonamide of 1,6-hexanediamine (HMMD) moieties provide increased proton affinities which dramatically improve the detection of the long-chain polysaccharides by FTICR-MS. The present approach allowed for identification of single components in mixtures with prominent heterogeneity in the degree of polymerization (DP), without the need for chromatographic separation prior to MS. The high mass accuracy was essential for the unambiguous characterization of the species observed in the analyzed mixtures. Furthermore, molecular components containing up to 42 glucose residues were detected, representing the largest polysaccharide chains analyzed so far by ESI FTICR-MS.  相似文献   

6.
Three ionisation techniques that require no sample preparation or extraction prior to mass analysis have been used for the rapid analysis of pharmaceutical tablets and ointments. These methods were (i) the novel direct analysis in real time (DART), (ii) desorption electrospray ionisation (DESI), and (iii) desorption atmospheric pressure chemical ionisation (DAPCI). The performance of the three techniques was investigated for a number of common drugs. Significant differences between these approaches were observed. For compounds of moderate to low polarity DAPCI produced more effective ionisation. Accurate DESI and DAPCI tandem mass spectra were obtained and these greatly enhance the selectivity and information content of the experiment. The detection from human skin of the active ingredients from ointments is reported together with the detection of ibuprofen metabolites in human urine.  相似文献   

7.
Arachnid venoms present a diverse and complex matrix for investigation, with their latent potential for innovative drug and pesticide design largely unrealised. The characterisation and quantification of selected low molecular mass compounds isolated from the crude venom of the Cobalt blue tarantula (Haplopelma lividum) were the objectives of this study. Fractionation of the crude venom was performed using reversed‐phase high‐performance liquid chromatography, with compound identification using both electrospray ionisation ion trap mass spectrometry and quadrupole time‐of‐flight mass spectrometry. Four compounds were identified, and quantification on a percentage dry weight basis was achieved by liquid chromatography/electrospray ionisation tandem mass spectrometry based on the formation of their corresponding product ions. Of these the most abundant component was glutamic acid, present at a level of 0.97%. Histamine and adenosine were detected at 0.14% and 0.10% dry weight, respectively, with the polyamine spermine noted in trace amounts at 0.002%. The limits of detection and quantification were established for each of the identified components. The fragmentation profile for histamine has also been proposed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
We have developed a direct method for the qualitative analysis of polyphenols in commercial organic fruit juices. The juices were diluted with water (50/50), filtered and directly injected. The analysis of phenolic compounds was carried out by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to photodiode array detection (DAD) and electrospray ionisation-Qq-time-of-flight mass spectrometry (ESI-Qq-TOF-MS). A unique gradient program has been optimized for the separation of several phenolic classes and the analysis time was only 5 min. The fruit juice samples were successfully analysed in positive and negative ionisation modes. In positive mode the anthocyanins were identified whereas the vast majority of polyphenols were identified using the negative ionisation mode. The sensitivity, together with mass accuracy and true isotopic pattern of the Qq-TOF-MS, allowed the identification of the phenolic compounds. Moreover, the advantage of the proposed method is the combined search of MS and MS/MS spectra, which improves the identification of compounds considerably, reducing ambiguities and false positive hits. Therefore the total fragmentation of the compound ion leading to the aglycone ion or other fragments was corroborated by MS–MS. The method was successfully employed to characterize diverse phenolic families in commercially available organic juices from four different fruits and consequently could be used in the future for the quantification purposes to compare different content of polyphenols in juices.  相似文献   

9.
Supercritical fluid chromatography (SFC) is fast becoming a technique of choice for the analysis of a wide range of compounds and has been found to be complementary to high-performance liquid chromatography (HPLC). The combination of SFC and mass spectrometry (MS) affords a very useful tool in the separation and analysis of compounds. In this study the ionisation of samples in the absence of an applied electrospray voltage has been observed when using SFC/MS, with some compounds showing increased sensitivity when all ionisation source high voltage (HV) is removed. In an attempt to understand the mechanism of ionisation, a series of test compounds were analysed using standard electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI) source configurations and also different API source designs. In both cases, data were acquired with the applied high voltage on (normal conditions) or with the high voltage off, i.e. no voltage spray (novo-spray). The standards were analysed with a range of pressure and modifier percentage conditions. To understand the nature of the ionisation process observed, this was compared with three established liquid-to-gas ionisation mechanisms. These were thermospray (TSP), charge residue model (CRM) of ESI and sonic spray ionisation (SSI). Experiments were undertaken in an attempt to explain this ionisation phenomenon and quantify any observed change in sensitivity. The most important point to note is that enhanced ionisation was observed under novo-spray conditions in a SFC/MS configuration, which in certain cases provides a lowering in the overall limit of detection (LOD).  相似文献   

10.
A library consisting of 3766 MS(n) spectra of 1743 compounds, including 3126 MS2 spectra acquired mainly using ion trap (IT) and triple-quadrupole (QqQ) instruments, was composed of numerous collections/sources. Ionization techniques were mainly electrospray ionization and also atmospheric pressure chemical ionization and chemical ionization. The library was tested for the performance in identification of unknowns, and in this context this work is believed to be the largest of all known tests of product-ion mass spectral libraries. The MS2 spectra of the same compounds from different collections were in turn divided into spectra of 'unknown' and reference compounds. For each particular compound, library searches were performed resulting in selection by taking into account the best matches for each spectral collection/source. Within each collection/source, replicate MS2 spectra differed in the collision energy used. Overall, there were up to 950 search results giving the best match factors and their ranks in corresponding hit lists. In general, the correct answers were obtained as the 1st rank in up to 60% of the search results when retrieved with (on average) 2.2 'unknown' and 6.2 reference replicates per compound. With two or more replicates of both 'unknown' and reference spectra (the average numbers of replicates were 4.0 and 7.8, respectively), the fraction of correct answers in the 1st rank increased to 77%. This value is close to the performance of established electron ionization mass spectra libraries (up to 79%) found by other workers. The hypothesis that MS2 spectra better match reference spectra acquired using the same type of tandem mass spectrometer (IT or QqQ) was neither strongly proved nor rejected here. The present work shows that MS2 spectral libraries containing sufficiently numerous different entries for each compound are sufficiently efficient for identification of unknowns and suitable for use with different tandem mass spectrometers.  相似文献   

11.
Protonated molecules of 2,5-di-R1,R2-substituted-1,3,4-oxadiazoles lose isocyanic acid (loss of mass 43) via skeletal rearrangement. This was observed in low-energy CID mass spectra recorded by using electrospray ionisation (ESI). On electron ionisation induced decomposition these compounds also reveal complex skeletal rearrangement, consisting on N2 and CO elimination, leading to the formation of fluorene or indene type ions. It was found that abundances of fragment ions formed in these processes are in good agreement with their theoretically calculated stabilities. In the case of ESI use the fragment ion abundances were calculated in relation to [M+H]+ ion abundances and for EI use, where extensive fragmentations proceed, the sums of the abundances of [M-N2-CO]+. ions and abundances of fragment ions derived from them, were expressed as a percentage of total-ion current.  相似文献   

12.
Electron ionisation (EI) mass spectra and electrospray ionisation (ESI) mass spectra at different cone voltages of a series of isomeric methyl- and dimethylalloxazines are discussed, and compared with those of lumichrome, and 1- and 3-methyllumichrome. Examination of ESI mass spectra taken at a higher cone voltage and the use of isotope-labelled methanol allow us to discuss the fragmentation pathways of [M+H]+ and [M-H](-) ions. The fragmentation pathways of all of the compounds and the characteristic fragment ions formed in EI-MS are compared with published data. The influence of methyl and dimethyl substituents in the benzene ring on the fragmentation pathways leading to the loss of 43 and 45 Da upon both electron and electrospray ionisation is described.  相似文献   

13.
Combinatorial chemistry is widely used within the pharmaceutical industry as a means of rapid identification of potential drugs. With the growth of combinatorial libraries, mass spectrometry (MS) became the key analytical technique because of its speed of analysis, sensitivity, accuracy and ability to be coupled with other analytical techniques. In the majority of cases, electrospray mass spectrometry (ES-MS) has become the default ionisation technique. However, due to the absence of fragment ions in the resulting spectra, tandem mass spectrometry (MS/MS) is required to provide structural information for the identification of an unknown analyte. This work discusses the first steps of an investigation into the fragmentation pathways taking place in electrospray tandem mass spectrometry. The ultimate goal for this project is to set general fragmentation rules for non-peptidic, pharmaceutical, combinatorial compounds. As an aid, an artificial intelligence (AI) software package is used to facilitate interpretation of the spectra. This initial study has focused on determining the fragmentation rules for some classes of compound types that fit the remit as outlined above. Based on studies carried out on several combinatorial libraries of these compounds, it was established that different classes of drug molecules follow unique fragmentation pathways. In addition to these general observations, the specific ionisation processes and the fragmentation pathways involved in the electrospray mass spectra of these systems were explored. The ultimate goal will be to incorporate our findings into the computer program and allow identification of an unknown, non-peptidic compound following insertion of its ES-MS/MS spectrum into the AI package. The work herein demonstrates the potential benefit of such an approach in addressing the issue of high-throughput, automated MS/MS data interpretation.  相似文献   

14.
Haloperidol, paracetamol, metronidazole and metamizole have been tested as tune compounds for electrospray ionisation in-source collision-induced dissociation MS (ESI-CID-MS) with two different mass spectrometers (Sciex API 365 and Agilent 1100 MSD SL). The different electrospray sources of API 365 and MSD 1100 SL consist of an orifice with nitrogen curtain gas and a capillary interface, respectively. In-source CID occurs in both interfaces in front of the skimmers, which separate a region with a vacuum of approximately 300 Pa and the high vacuum (<10(-3) Pa). Comparison of the breakdown curves of selected tune compounds, depending on collision energy (orifice or fragmentor voltage), showed, that very similar fragmentation can be obtained with both instruments, when adjusting the fragmentor voltage of the MSD 1100 SL to higher values than the orifice voltage of the API 365. For three energy levels--low, medium and high--the corresponding voltages were 20, 50 and 80 V for the API 365 and 110, 190, 230 V for the MSD 1100 SL. These voltages resulted in the most similar spectra for haloperidol and paracetamol with both instruments. The comparison of ESI-CID-MS of all tune compounds at three energy levels showed, that - despite variations in relative ion abundances - all significant ions were present in one of the three CID spectra. Therefore, mass spectral library searching of an ESI-CID-MS library set-up with one of the two instruments should be possible with the other instrument after adjusting the CID energies by means of at least two tune compounds such as haloperidol and paracetamol, metronidazole or metamizole.  相似文献   

15.
The atmospheric-pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI-QIT) analysis of tryptic peptides is reported following capillary liquid chromatographic (LC) separation and direct analysis of a protein digest. Peptide fragments were identified by peptide mass fingerprinting from mass spectrometric data and sequence analysis obtained by tandem mass spectrometry of the principal mass spectral peaks using a data-dependent scanning protocol. These data were compared with those from mass spectrometric analysis using capillary LC/MALDI-time-of-flight (TOF) and capillary LC/electrospray ionisation (ESI)-quadrupole TOF. For all three configurations the resulting data were searched against the MSDB database, using MASCOT and the sequence coverage compared for each technique. Complementary data were obtained using the three techniques.  相似文献   

16.
Kidneys of clams of the genus Tridacna accumulate metabolic products from symbiotic unicellular algae that grow in the mantles of the clams. These metabolites include organoarsenic compounds that are biosynthesised by algae from arsenate in seawater. The arsenic compounds in aqueous extracts of the kidney of the giant clam T. derasa were investigated by liquid chromatography/electrospray ionisation mass spectrometry. About 50% of the water-soluble arsenic was present as dimethylarsinoylribosides and dimethylarsinate which are common algal metabolites. The major compound in the kidney (50% of water-soluble arsenic) was identified as a 5-dimethylarsinoyl-2,3,4-trihydroxycarboxylic acid, a new natural product.  相似文献   

17.
Zibu Piyin recipe (ZBPYR), a traditional Chinese medicine formula, is used for curing dementia caused by diabetes. For quality control of ZBPYR, ?ngerprint analysis and qualitative analysis using high-performance liquid chromatography (HPLC) with a diode-array detector, and confirmation using HPLC coupled with electrospray ionisation quadrupole time-of-?ight tandem mass spectrometry (HPLC-Q-TOF-MS) were undertaken. HPLC fingerprint consisting of 34 common peaks was developed among 10 batches of ZBPYR, in which 7 common peaks were identified in comparison with the authentic standards and detected simultaneously. Furthermore, these seven compounds were verified by HPLC-Q-TOF-MS methods. The method can be applied to the quality control of ZBPYR.  相似文献   

18.
Desorption electrospray ionisation (DESI) and neutral desorption/extractive electrospray ionisation (EESI) have been coupled to a hybrid quadrupole travelling-wave (T-Wave)-based ion mobility time-of-flight mass spectrometer for the direct accurate mass analysis of active ingredients formulated into pharmaceutical samples. The collision cross-section measurements of polyethylene glycol (PEG) excipients detected in one formulation were estimated and compared with published data. These estimated collision cross-sections of the PEG species showed good agreement with published data.  相似文献   

19.
A fast and selective LC/MS/MS method for the screening of four anabolic steroids in human urine has been developed and validated. Liquid-liquid extraction with diethyl ether was applied after enzymatic hydrolysis. Analyses were performed on an ion trap mass spectrometer equipped with electrospray ionisation. MS/MS was applied for all compounds. The analytical run time was 11 min. The LOD for all compounds varied between 1 and 10 ng/mL. Left-over A samples, which were declared positive by GC/MS for the presence of 3'-hydroxystanozolol, were assessed using the described method.  相似文献   

20.
The effect of matrix composition on signal suppression caused by a dominant compound under MALDI ionization was studied using the combinatorial TQTXT pentapeptide library as a model system. The peptide library is composed of 19 components with all proteinogenic amino acids except cysteine in position X. From these compounds, only the Arg peptide (TQTRT) was detected with sufficient intensity in the MALDI-TOF mass spectrum under typical MALDI conditions (CCA matrix). The analysis of a set of compounds utilized as different matrix components, additives and a cationizing agent revealed that the composition of the matrix is a critical point in signal suppression. Highly improved ion yields were achieved by using a CCA/DHB mixture as a matrix. The addition of K(+) as a cationizing agent to the CCA matrix resulted in MALDI-TOF mass spectra with relative ion intensities very similar to those obtained by electrospray ionization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号