首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In selected ion flow tube mass spectrometry, SIFT‐MS, analyses of humid air and breath, it is essential to consider and account for the influence of water vapour in the media, which can be profound for the analysis of some compounds, including H2CO, H2S and notably CO2. To date, the analysis of methane has not been considered, since it is known to be unreactive with H3O+ and NO+, the most important precursor ions for SIFT‐MS analyses, and it reacts only slowly with the other available precursor ion, O. However, we have now experimentally investigated methane analysis and report that it can be quantified in both air and exhaled breath by exploiting the slow O/CH4 reaction that produces CH3O ions. We show that the ion chemistry is significantly influenced by the presence of water vapour in the sample, which must be quantified if accurate analyses are to be performed. Thus, we have carried out a study of the loss rate of the CH3O analytical ion as a function of sample humidity and deduced an appropriate kinetics library entry that provides an accurate analysis of methane in air and breath by SIFT‐MS. However, the associated limit of detection is rather high, at 0.2 parts‐per‐million, ppm. We then measured the methane levels, together with acetone levels, in the exhaled breath of 75 volunteers, all within a period of 3 h, which shows the remarkable sample throughput rate possible with SIFT‐MS. The mean methane level in ambient air is seen to be 2 ppm with little spread and that in exhaled breath is 6 ppm, ranging from near‐ambient levels to 30 ppm, with no significant variation with age and gender. Methane can now be included in the wide ranging analyses of exhaled breath that are currently being carried out using SIFT‐MS. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
For the first time, CEC was coupled with tris(2,2‐bipyridyl) ruthenium(II) ( Ru(bpy) electrochemiluminescence detection. Efficient CEC separations of proline, putrescine, spermidine and spermine were achieved when the pH of the mobile phase is in the range of 3.5–7.0. The optimum mobile phase for CEC separation is much less acidic than that for CZE separation, which matches better with the optimum pH for Ru(bpy) electrochemiluminescence detection and dramatically shortens the analysis time because of larger EOF at higher pH. The time for CEC separation of the polyamines is less than 12.5 min, which is about half as much as the time needed for CZE. The detection limits were 1.7, 0.2, and 0.2 μM for putrescine, spermidine, and spermine, respectively. The RSD of retention time and peak height of these polyamines were less than 0.85 and 6.1%, respectively. The column showed good long‐term stability, and the RSD of retention time is below 5% for 150 runs over one‐month use. The method was successfully used for the determination of polyamines in urine samples.  相似文献   

3.
The reactions of H3O+, NO+, and O with nineteen ester compounds occurring naturally in plants, and having important flavourant properties, were examined using selected ion flow tube mass spectrometry (SIFT‐MS). The H3O+ reactions primarily generate [R1COOR2·H]+, and may also produce [R2]+ fragment ions and/or fragmentation within the ester linkage. Collisional association/adduct ions, [R1COOR2·NO]+, are the main products formed in the NO+ reactions, although the carboxyl fragment ion is also detected frequently. The identification of the parent compound may be made more easily in the H3O+ and NO+ reactions. The inclusion of O reactions in the analysis provides additional information, which may be applied when the identity of a parent compound cannot be determined solely from the H3O+ and NO+ analysis. Consideration of the product ions generated with the three precursors suggests that SIFT‐MS can differentiate between many of the esters investigated, including isomers, although the product ions generated in the reactions with some esters are too similar to allow independent quantification. Our data therefore suggest that SIFT‐MS may be a useful tool to rapidly analyse and quantify flavourant esters in complex gas mixtures. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
The reactions of carbon dioxide, CO2, with the precursor ions used for selected ion flow tube mass spectrometry, SIFT‐MS, analyses, viz. H3O+, NO+ and O, are so slow that the presence of CO2 in exhaled breath has, until recently, not had to be accounted for in SIFT‐MS analyses of breath. This has, however, to be accounted for in the analysis of acetaldehyde in breath, because an overlap occurs of the monohydrate of protonated acetaldehyde and the weakly bound adduct ion, H3O+CO2, formed by the slow association reaction of the precursor ion H3O+ with CO2 molecules. The understanding of the kinetics of formation and the loss rates of the relevant ions gained from experimentation using the new generation of more sensitive SIFT‐MS instruments now allows accurate quantification of CO2 in breath using the level of the H3O+CO2 adduct ion. However, this is complicated by the rapid reaction of H3O+CO2 with water vapour molecules, H2O, that are in abundance in exhaled breath. Thus, a study has been carried out of the formation of this adduct ion by the slow three‐body association reaction of H3O+ with CO2 and its rapid loss in the two‐body reaction with H2O molecules. It is seen that the signal level of the H3O+CO2 adduct ion is sensitively dependent on the humidity (H2O concentration) of the sample to be analysed and a functional form of this dependence has been obtained. This has resulted in an appropriate extension of the SIFT‐MS software and kinetics library that allows accurate measurement of CO2 levels in air samples, ranging from very low percentage levels (0.03% typical of tropospheric air) to the 6% level that is about the upper limit in exhaled breath. Thus, the level of CO2 can be traced through single time exhalation cycles along with that of water vapour, also close to the 6% level, and of trace gas metabolites that are present at only a few parts‐per‐billion. This has added a further dimension to the analysis of major and trace compounds in breath using SIFT‐MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
The reactions of H3O+, NO+ and O with twelve terpenoids and one terpene, all of which occur naturally in plants and which possess important smell and flavourant properties, were characterized using Selected Ion Flow Tube Mass Spectrometry (SIFT‐MS). The H3O+ reactions resulted primarily in the formation of the proton transfer product and occasionally in a water elimination product. The NO+ reactions instead generated the charge transfer product or NO+ adducts, and occasionally alkyl fragments, or resulted in hydride abstraction. Reaction with O caused a higher fragmentation of the terpenoids with the molecular ion being the minor product of most reactions. Identification and quantification of each compound in complex mixtures are probably possible in most cases using the H3O+ and/or NO+ precursors while O may be useful for isomer discrimination. Our data suggests that SIFT‐MS may be a useful tool for the rapid analysis of these compounds in plants and derived foodstuffs. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
Analytical methods are described for the quantitative determination of putrescine, cadaverine, spermidine, spermine and the acetylated derivatives of spermidine and spermine in biological fluids using pre-column derivatization with either benzoyl chloride or 3,5-dinitrobenzoyl chloride, which were added to each sample as solutions in diethyl ether. Putrescine, spermidine and spermine can be analysed in seminal plasma at nanogram levels when benzoyl chloride is used as derivatizing agent. In the analysis of putrescine, cadaverine, spermidine and acetyl derivatives of spermidine and spermine, higher sensitivity is obtained with 3,5-dinitrobenzoyl-chloride. This method can readily be used in the determination of acetylated polyamines in urine samples.  相似文献   

7.
A mass spectrometric method using electrospray ionization with triple quadrupole and quadrupole time‐of‐flight hybrid (Q‐Tof) mass spectrometry has been applied to the structural characterization of dihydroflavonols. This family of compounds has been studied by liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the first time in this work. A comprehensive study of the product ion MS spectra of the [M+H]+ ion of a commercially available standard has been performed. The most useful fragmentations in terms of structural identification are those that involve cleavage of the C‐ring, resulting in diagnostic ions of dihydroflavonol family: 1,3A, 1,2B, 1,2B‐CO, 0,2A, 0,2A‐H2O, 0,2A‐CO, and 0,2A‐H2O‐CO, that allow the characterization of the substituents in the A‐ and B‐rings. In addition to those ions, other product ions due to losses of H2O and CO molecules from the Y ion were observed. Their fragmentation mechanisms and ion structures have been proposed. The established fragmentation patterns have been used to successfully identity three dihydroflavonols found in tangerine juices for the first time. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
A novel analytical method for biological polyamines (putrescine, spermidine and spermine) was developed. Polyamines were separated by ion-pair reversed phase chromatography using a polymer-based octadecyl bonded column. A polyamine oxidase immobilized column worked effectively as a post-column reactor to convert polyamines to hydrogen peroxide which was eventually detected by electrochemical oxidation on platinum electrode. This method required neither tedious derivatization nor gradient elution, permitting us to perform simple and rapid analysis of polyamines. The detection limits were 0.3, 0.6, and 4 pmol injected for putrescine, spermidine, and spermine, respectively with a linear range of two to three orders of magnitude. Chromatograms obtained with samples from human urine and rat brain homogenates demonstrated the high sensitivity and selectivity of the method.  相似文献   

9.
Some newly synthesized 10B nido‐carborane derivatives, i.e., 7,8‐dicarba‐nido‐undecaborane monoanions ([7‐Me‐8‐R‐C2B9H10]K+, R = H, butyl, hexyl, octyl and decyl), have been fully characterised and examined by electrospray ionization and Fourier transform ion cyclotron resonance mass spectrometry with liquid chromatographic separation (LC/ESI‐FTICR‐MS). These boron‐containing compounds exhibit abundant molecular ions ([M]?) at m/z 140.22631 [CB9H14]?, m/z 196.28883 [CB9H22]?, m/z 224.32032 [CB9H26]?, m/z 252.35133 [CB9H30]? and m/z 280.38354 [CB9H34]? at the normal tube lens voltage setting of ?90 V, which was an instrumental parameter value selected in the tuning operation. Additional [M–nH2]? (n = 1?4) ions were observed in the mass spectra when higher tube lens voltages were applied, i.e., ?140 V. High‐resolution FTICR‐MS data revealed the accurate masses of fragment ions, bearing either an even or an odd number of electrons. Collision‐induced dissociation of the [M–nH2]? ions (n = 0–4) in the quadrupole linear ion trap (LTQ) analyzer confirmed the loss of hydrogen molecules from the molecular ions. It is suggested that the loss of H2 molecules from the alkyl chain is a consequence of the stabilization effect of the nido‐carborane charged polyhedral skeleton. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
We describe a simple, rapid, selective and sensitive HPLC method coupled with fluorescence detection for simultaneous determination of 10 kinds of biogenic amines (BAs: tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, 5‐hydroxytryptamine, tyramine, spermidine, dopamine and spermine). BAs and IS were derivated with dansyl chloride. Fluorescence detection (λex/λem = 340/510 nm) was used. A satisfactory result for method validation was obtained. The assay was shown to be linear over the ranges 0.005–1.0 μg/mL for tryptamine, 2‐phenethylamine and spermidine, 0.025–1.0 μg/mL for putrescine, 0.001–1.0 μg/mL for cadaverine, 0.25–20 μg/mL for histamine, 0.25–10 μg/mL for 5–hydroxytryptamine and dopamine, and 0.01–1.0 μg/mL for tyramine and spermine. The limits of detection and the limits of quantification were 0.3–75.0 ng/mL and 1.0–250.0 ng/mL, respectively. Relative standard deviations were ≤5.14% for intra‐day and ≤6.58% for inter‐day precision. The recoveries of BAs ranged from 79.11 to 114.26% after spiking standard solutions of BAs into a sample at three levels. Seven kinds of BAs were found in rat plasma, and the mean values of tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, spermidine and spermine determined were 52.72 ± 7.34, 11.45 ± 1.56, 162.56 ± 6.26, 312.75 ± 18.11, 1306.50 ± 116.16, 273.89 ± 26.41 and 41.51 ± 2.07 ng/mL, respectively.  相似文献   

11.
Protonated benzene, C6H, has been studied extensively to understand the structure and energy of a protonated organic molecule in the gas phase. The formation of C6H is either through direct protonation of benzene, i.e., chemical ionization, or through fragmentation of certain radical cations produced from electron ionization or photon ionization. We report a novel observation of C6H as a product ion formed in the collision‐induced dissociation (CID) of protonated benzamide and related molecules produced via electrospray ionization (ESI). The formation of C6H from these even‐electron precursor ions during the CID process, which has not been previously reported, is proposed to occur from the protonated molecules via a proton migration in a five‐membered ring intermediate followed by the cleavage of the mono‐substituent C? C bond and concurrent formation of an ion‐molecule complex. This unique mechanism has been scrutinized by examining some deuterated molecules and a series of structurally related model compounds. This finding provides a convenient mean to generate C6H, a reactive intermediate of considerable interest, for further physical or chemical investigation. Further studies indicate that the occurrence of C6H in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) appears to be a rather common phenomenon for many compounds that contain ‘benzoyl‐type’ moieties. Hence, the observation of the C6H ion in LC/ESI‐MS/MS can be used as an informative fragmentation pathway which should facilitate the identification of a great number of compounds containing the ‘benzoyl‐type’ and similar structural features. These compounds are frequently present in food and pharmaceutical products as leachable impurities that require strict control and rapid elucidation of their identities. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
《Electroanalysis》2004,16(4):260-267
An electrochemical flow analysis system was optimized together with immobilized putrescine oxidase and horseradish peroxidase for putrescine measurement. Four coupling agents, suberic acid bis(N‐hydroxysuccinimide ester), γ‐maleimidobutyric N‐hydroxysuccinimide ester, 1‐ethyl‐3‐(3‐dimethylaminopropyl)carbodiimide and glutaraldehyde, were used for immobilizing the two enzymes on porous aminopropyl glass beads to form a bienzymic detection column. Although the glutaraldehyde crosslinking procedure offered the highest response, the immobilized bienzyme system was responsive to putrescine, spermidine (123% of the putrescine response at 250 μM) and cadaverine (98% of the putrescine response). In contrast, the enzymes immobilized on the glass beads using suberic acid bis(N‐hydroxysuccinimide ester) offered significantly better selectivity towards putrescine at the same concentration. For comparison, cadaverine and spermidine only provoked a response of 4.7% and 27.5% of the putrescine signal. The response to cadaverine and spermidine was further suppressed by lowering the detection pH from 8 to 7. At 250 μM, the response obtained for cadaverine and spermidine was only 1.5% and 3.9%, respectively, of the signal obtained for putrescine. A linear response to putrescine was obtained from 5 to 75 μM (0.629 μAs μM?1, R2=0.997) with a detection limit of 5 μM (S/N=3). The amperometric response retained 75% of its initial value after 600 repeated injections. The immobilized PUO/HRP (putrescine oxidase/horseradish peroxidase) was successfully demonstrated for measuring putrescine in fish extracts as an indicator of fish spoilage.  相似文献   

13.
Summary Biologically active amines (putreanine sulphate, N-acetyl putrescine, putrescine, cadaverine, histamine, agmatine, N-acetyl spermidine, spermidine, spermine) were separated and quantified in cereal flour and cereal products by a liquid chromatographic method. The method consists of the separation of ion pairs formed between biologically active amines and octanesulphonic acid on a reversed-phase column, postcolumn derivatization with o-phtalaldehyde-2-mercapthoethanol and spectrofluorometric detection. Results of the reliability study were satisfactory. The method was linear for each amine at 1–10 mg L−1. Putrescine and spermidine were the only amines always detected in cereal flour and cereal products, ranging from 2.45 to 47.83 mg kg−1 for putrescine and 3.27 to 37.14 mg kg−1 for spermidine. The most important differences among types of samples were found in polyamine derivatives. Presented at: Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, September 3–5, 1997.  相似文献   

14.
To evaluate the potential relationship between cancer and polyamine metabolome, a UHPLC–MS/MS method has been developed and validated for simultaneous determination of polyamine precursors, polyamines, polyamine catabolite in human plasma and urine. Polyamine precursors including l-ornithine, lysine, l-arginine and S-adenosyl-l-methionine; polyamines including 1,3-diaminopropane, putrescine, cadaverine, spermidine, spermine, agmatine, N-acetylputrescine, N-acetylspermine and N-acetylspermidine; polyamine catabolite including γ-aminobutyric acid had been determined. The analytes were extracted from plasma and urine samples by protein precipitation procedure, and then separated on a Shim-pack XR-ODS column with 0.05% heptafluorobutyric acid (HFBA) in methanol and 0.05% HFBA in water. The detection was performed on UHPLC–MS/MS system with turbo ion spray source in the positive ion and multiple reaction-monitoring mode. The limits of quantitation for all analytes were within 0.125–31.25 ng mL−1 in plasma and urine. The absolute recoveries of analytes from plasma and urine were all more than 50%. By means of the method developed, the plasma and urine samples from hepatic cancer patients and healthy age-matched volunteers had been successfully determined. Results showed that putrescine and spermidine in hepatic cancerous plasma were significant higher than those in healthy ones, while spermidine, spermine and N-acetylspermidine in hepatic cancerous urine were significant higher than those in healthy ones. The methods demonstrated the changes of polyamine metabolome occurring in plasma and urine from human subjects with hepatic cancer. It could be a powerful manner to indicate and treat hepatic cancer in its earliest indicative stages.  相似文献   

15.
A capillary gas chromatographic method with nitrogen-phosphorus detection is used to determine simultaneously 1,3-diaminopropane, putrescine, cadaverine, spermidine and spermine in human erythrocytes. The compounds are isolated by adsorption on silica and converted into their heptafluorobutyryl derivatives. We give quality-control data and (age-dependent) normal values for 48 apparently healthy controls.  相似文献   

16.
In the present study we report on the optimization and validation of a sensitive high performance liquid chromatography atmospheric pressure chemical ionization mass spectrometry (HPLC–APCI–MS) method for the determination of 8 bioactive amines (histamine, tyramine, tryptamine, 2-phenylethylamine, cadaverine, putrescine, spermidine and spermine) in donkey milk samples. The method involves donkey milk pre-treatment to remove proteins and pre-column dansylation of the amines. HPLC in reversed phase mode has been used for bioactive amines separation and the operating condition of the APCI–MS system proved to be powerful and very efficient for peak assignment. The separation was accomplished in a short time with an excellent resolution for all the amine peaks. Quantification was carried out by monitoring the characteristic [M+H]+ ion of each amine derivative. The method sensitivity, linearity and repeatability were assayed with satisfactory results. The detection limits of the analysed amines ranged from 0.5 μg L−1 to 15 μg L−1; the highest LOD was for spermine. Also remarkably good recovery values were obtained; at the lowest spiking level (1 μg L−1) the percent mean recoveries ranged from 77.7 to 109.7. Furthermore, as the investigations relate to a complex matrix as donkey milk, suitable studies on matrix effect were performed. Finally, the developed and validated method was applied to analyse 13 donkey milk samples. Among the identified bioactive amines, putrescine, spermine and spermidine proved to be the main amines in donkey milk. Their concentration levels in the present study were lower than the values determined in mature human, cow and sow milk.  相似文献   

17.
Abstract

Ten amines found in marine foods, dimethylamine, trimethylamine, trimethylamine oxide, ammonia, urea, histamine, cadaverine, putrescine, spermine and spermidine were separated by HPLC using an ion-moderated partition column. Optimum resolution and sensitivity were obtained using 0.003N sodium hydroxide as the mobile phase and UV detection at 208 nm.  相似文献   

18.
The mass spectrometric characterization of aqueous solutions of α‐ and β‐cyclodextrins (CDs) and o‐, m‐ and p‐coumaric acids (CAs) by negative ion electrospray ionization (ESI) indicates that the [CD+CA]? ions were sourced from the inclusion complex present in solution and from the anion attached to CD molecules formed in the spray processes. The anion adducts formed in the spray process contribute significantly to the signal intensity of an ionized inclusion complex thus overestimating the calculated stability constant (K) of solution‐phase complexes by one to two orders of magnitude. The relative intensities of anion adducts in mass spectra depend on the concentration ratio of the anion and the CD in spray droplets, while the relative intensity of the ionized inclusion complex depends on CD and CA concentrations in solutions and the value of K. Ion Mobility Spectrometry Mass Spectrometry [IMS‐MS] measurements show that the collision cross‐section (Ω) values of the [CD+CA]? or [(CD)2+CA]2? and [CD+CA] complex ions are 5–6% larger than or equal to CD? or [CD], respectively. Therefore, in the gas phase the anion adducts [CD+CA?] on cyclodextrin molecules possess the same conformations as the ionized inclusion complexes [CD+CA]?. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
The extraction of ornithine, lysine, putrescine, cadaverine, 1,7-diaminoheptane, spermidine and spermine from biological tissues was optimized for HPLC quantitation as their o-phthalaldehyde/ethanethiol/fluorenylmethyl chloroformate (OPA/ET/FMOC) derivatives. In applying perchloric acid deproteinization two approaches have been followed: (i) deproteinization with subsequent neutralization by potassium hydroxide and lyophilization, and (ii) deproteinization without neutralization and lyophilization. Neutralization and lyophilization resulted in the loss of free biogenic amines. HPLC analysis of ornithine (Orn), lysine (Lys), putrescine (Put), cadaverine (Cad), 1,7-diaminoheptane (Dah), spermidine (Spd) and spermine (Spm) content of biological tissues as their OPA/ET/FMOC derivatives was performed in the supernatant of perchloric acid-deproteinized samples (model solutions and tissues) with an average reproducibility of < or =2.6% relative standard deviation (RSD), including recovery of sample treatment and chromatography.  相似文献   

20.
A high‐performance liquid chromatography coupled with Q‐time of flight mass spectrometry (HPLC/Q‐TOF MS) method was developed and validated for the determination of 1, 3‐diaminopropane, putrescine, cadaverine, spermidine and spermine in human plasma. The plasma samples were first pretreated by 10% HClO4 and then derived by benzoyl chloride with 1, 6‐diaminohexane as internal standard. The derived polyamines were separated on a C18 column using a gradient program. The detection was performed on a Q‐TOF MS by positive ionization mode. Calibration curve for each polyamine was obtained in the concentration range of 0.4 ~ 200.0 ng ? ml?1, with limit of detection of 0.02 ~ 0.1 ng ? ml?1. The intra‐ and inter‐day RSD for all polyamines were 2.5–14.0% and 2.9 ~ 13.4%, respectively. The method was applied to determine the polyamines in human plasma from cancer patients and healthy volunteers. Results showed that the mean levels of polyamines in the plasma of cancer patients were higher than that of healthy volunteers, which suggested that the plasma polyamines could be employed as cancer diagnostic indicators in clinical testing. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号