首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The atmospheric pressure ionization (API) source for a commercial mass spectrometer was modified to operate as a dual source in both the electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) techniques by simultaneously utilizing the electrospray probe and the corona discharge needle. A switching box was designed to operate in either manual or programmable modes to permit rapid switching between ionization techniques without changing sources, probes, or breaking vacuum. The source can be operated using the following ionization techniques: ESI only, APCI only, ESI/APCI simultaneously, and ESI/APCI alternatingly. The optimum operating conditions for these ionization techniques were similar to the manufacturer’s original specifications except that the APCI flow rate was lower (~50 µL/min versus 1000 µL/min) and externally heated nebulizing gas was found to be desirable. A four-component mixture, introduced by flow injection, was used to demonstrate the versatility of the dual ESI/APCI source.  相似文献   

2.
An ionspray microchip is introduced. The chip is based on the earlier presented nebulizer microchip that consists of glass and silicon plates bonded together. A liquid inlet channel, nebulizer gas inlet, and nozzle are etched on the silicon plate and a platinum heater is integrated on the glass plate. The nebulizer microchip has been previously used in atmospheric pressure chemical ionization, atmospheric pressure photoionization, sonic spray ionization, and thermospray ionization modes. In this work we show that the microchip can be operated also in ionspray mode by introducing high voltage to the silicon plate of the microchip. The effects of operation parameters (voltage, nebulizer gas pressure, sample solution flow rate, solvent composition, and analyte concentration) on the performance of the ion spray microchip were studied. Under optimized conditions the microchip provides efficient ionization of small and large compounds and good quantitative performance. The feasibility of the ion spray microchip in liquid chromatography/mass spectrometry (LC/MS) was demonstrated by the analysis of tryptic peptides of bovine serum albumin. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
A novel ion/molecule reaction was observed to occur under electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo ionization (APPI) conditions, leading to dimerization of ionized 4‐(methyl mercapto)‐phenol followed by fast H· loss. The reaction is particularly favored during ESI, which suggests that this ion/molecule reaction can occur both in the solution inside the ESI‐charged droplets and in the gas‐phase environment of most other atmospheric pressure ionization techniques. The dimerization reaction is inherent to the electrolytic process during ESI, whereas it is more by ion/molecule chemistry in nature during APCI and APPI. From the tandem mass spectrometry (MS/MS) data, accurate mass measurements, hydrogen/deuterium (H/D) exchange experiments and density functional theory (DFT) calculations, two methyl sulfonium ions appear to be the most likely products of this electrophilic aromatic substitution reaction. The possible occurrence of this unexpected reaction complicates mass spectral data interpretation and can be misleading in terms of structural assignment as reported herein for 4‐(methyl mercapto)‐phenol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Triclosan is a widely used broad‐spectrum antibacterial agent that acts by specifically inhibiting enoyl–acyl carrier protein reductase. An in vitro metabolic study of triclosan was performed by using Sprague‐Dawley (SD) rat liver S9 and microsome, while the in vivo metabolism was investigated on SD rats. Twelve metabolites were identified by using in‐source fragmentation from high‐performance liquid chromatography/negative atmospheric pressure chemical ionization ion trap mass spectrometry (HPLC/APCI‐ITMS) analysis. Compared to electrospray ionization mass spectrometry (ESI‐MS) and tandem mass spectrometry (MS/MS) that gave little fragmentation for triclosan and its metabolites, the in‐source fragmentation under APCI provided intensive fragmentations for the structural identifications. The in vitro metabolic rate of triclosan was quantitatively determined by using HPLC/ESI‐ITMS with the monitoring of the selected triclosan molecular ion. The metabolism results indicated that glucuronidation and sulfonation were the major pathways of phase II metabolism and the hydroxylated products were the major phase I metabolites. Moreover, glucose, mercapturic acid and cysteine conjugates of triclosan were also observed in the urine samples of rats orally administrated with triclosan. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
Negative corona discharge atmospheric pressure chemical ionization (APCI) was used to investigate phenols with varying numbers of tert‐butyl groups using ion mobility spectrometry–mass spectrometry (IMS‐MS). The main characteristic ion observed for all the phenolic compounds was the deprotonated molecule [M–H]. 2‐tert‐Butylphenol showed one main mobility peak in the mass‐selected mobility spectrum of the [M–H] ion measured under nitrogen atmosphere. When air was used as a nebulizer gas an oxygen addition ion was seen in the mass spectrum and, interestingly, this new species [M–H+O] had a shorter drift time than the lighter [M–H] ion. Other phenolic compounds primarily produced two IMS peaks in the mass‐selected mobility spectra measured using the [M–H] ion. It was also observed that two isomeric compounds, 2,4‐di‐tert‐butylphenol and 2,6‐di‐tert‐butylphenol, could be separated with IMS. In addition, mobilities of various characteristic ions of 2,4,6‐trinitrotoluene were measured, since this compound was previously used as a mobility standard. The possibility of using phenolic compounds as mobility standards is also discussed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even‐ and odd‐electron ions, whereas the other ionization techniques produced even‐electron ions only. In‐source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full‐scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6‐dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
On‐line ion trap mass spectrometry (ITMS) enables the real‐time characterization of reaction products of secondary organic aerosol (SOA). The analysis was conducted by directly introducing the aerosol particles into the ion source. Positive‐ion chemical ionization at atmospheric pressure (APCI(+)) ITMS was used for the characterization of constituents of biogenic SOA produced in reaction‐chamber experiments. APCI in the positive‐ion mode usually enables the detection of [M+H]+ ions of the individual SOA components. In this paper the identification of organic peroxides from biogenic volatile organic compounds (VOCs) by on‐line APCI‐ITMS is presented. Organic peroxides containing a hydroperoxy group, generated by gas‐phase ozonolysis of monoterpenes (α‐pinene and β‐pinene) and sesquiterpenes (α‐cedrene and α‐copaene), could be detected via on‐line APCI(+)‐MS/MS experiments. A characteristic neutral loss of 34 Da (hydrogen peroxide, H2O2) in the on‐line MS/MS spectra is a clear indication for the existence of an organic peroxide, containing a hydroperoxy functional group. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
We have investigated the composition of the mobile natural organic matter (NOM) present in Callovo‐Oxfodian pore water using electrospray ionization mass spectrometry (ESI‐MS), atmospheric pressure chemical ionization mass spectrometry (APCI‐MS) and emission‐excitation matrix (EEM) spectroscopy. The generation of knowledge of the composition, structure and size of mobile NOM is necessary if one wants to understand the interactions of these compounds with heavy metals/radionuclides, in the context of environmental studies, and particularly how the mobility of these trace elements is affected by mobile NOM. The proposed methodology is very sensitive in unambiguously identifying the in situ composition of dissolved NOM in water even at very low NOM concentration, due to innovative non‐disturbing water sampling and ionization (ESI/APCI‐MS) techniques. It was possible to analyze a quite exhaustive inventory of the small organic compounds of clay pore water without proceeding to any chemical treatment at naturally occurring concentration levels. The structural features observed were mainly acidic compounds and fatty acids as well as aldehydes and amino acids. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Accurate measurement of estradiol (E2) is important in clinical diagnostics and research. High sensitivity methods are critical for specimens with E2 concentrations at low picomolar levels, such as serum of men, postmenopausal women and children. Achieving the required assay performance with LC–MS is challenging due to the non‐polar structure and low proton affinity of E2. Previous studies suggest that ionization has a major role for the performance of E2 measurement, but comparisons of different ionization techniques for the analysis of clinical samples are not available. In this study, female serum and endometrium tissue samples were used to compare electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) in both polarities. APPI was found to have the most potential for E2 analysis, with a quantification limit of 1 fmol on‐column. APCI and ESI could be employed in negative polarity, although being slightly less sensitive than APPI. In the presence of biological background, ESI was found to be highly susceptible to ion suppression, while APCI and APPI were largely unaffected by the sample matrix. Irrespective of the ionization technique, background interferences were observed when using the multiple reaction monitoring transitions commonly employed for E2 (m/z 271 > 159; m/z 255 > 145). These unidentified interferences were most severe in serum samples, varied in intensity between ionization techniques and required efficient chromatographic separation in order to achieve specificity for E2. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
We report a miniaturized excitation source for soft ionization of molecules based on a dielectric barrier discharge. An atmospheric plasma is established at the end of a 500 μm diameter capillary using He as buffer gas. The plasma jet which comes out of the capillary is dependent on the gas flow rate. The mechanism of the production of N2+ outside the capillary, which is relevant for the protonation of molecules and sustains the production of primary ions, is investigated by spatially resolved spectroscopic measurements throughout the plasma. Possible application of such miniaturized plasmas is the ionization of gaseous compounds under atmospheric pressure as an alternative to traditional APCI (atmospheric pressure chemical ionization). The miniaturized plasma was applied as ionization source for ion mobility spectrometry where the common sources are radioactive, thus limiting the place of installation. First measurements of gaseous compounds with such a plasma ion mobility spectrometer with promising results showed detection limits comparable or even better than those obtained using common radioactive ionization sources.  相似文献   

11.
Although the coupling of GC/MS with atmospheric pressure ionization (API) has been reported in 1970s, the interest in coupling GC with atmospheric pressure ion source was expanded in the last decade. The demand of a “soft” ion source for preserving highly diagnostic molecular ion is desirable, as compared to the “hard” ionization technique such as electron ionization (EI) in traditional GC/MS, which fragments the molecule in an extensive way. These API sources include atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), atmospheric pressure laser ionization (APLI), electrospray ionization (ESI) and low temperature plasma (LTP). This review discusses the advantages and drawbacks of this analytical platform. After an introduction in atmospheric pressure ionization the review gives an overview about the history and explains the mechanisms of various atmospheric pressure ionization techniques used in combination with GC such as APCI, APPI, APLI, ESI and LTP. Also new developments made in ion source geometry, ion source miniaturization and multipurpose ion source constructions are discussed and a comparison between GC-FID, GC-EI-MS and GC-API-MS shows the advantages and drawbacks of these techniques. The review ends with an overview of applications realized with GC-API-MS.  相似文献   

12.
Collision induced dissociation (CID) has been extensively used for structure elucidation. CID in the electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) modes has been found to generate mostly even‐electron fragment ions while it has been occasionally reported to form odd‐electron free radical ions. However, the structural requirements and the fragmentation mechanisms for free‐radical CIDs have not been well characterized in the literature. For this purpose, we studied a series of aromatic and non‐aromatic compounds such as sulfonamides, N‐aryl amides, tert‐butyl‐substituted aromatic compounds, aryl alkyl ethers, and O‐alkyl aryl oximes using the LTQ? and LTQ Orbitrap? linear ion trap mass spectrometers. The accurate measurement of the fragment ion masses established the unambiguous assignment of the fragment structures resulting from the test compounds. Our results showed that free radical fragmentation is structure dependent and is to a large extent correlated with the neighboring groups in the structures that stabilize the newly formed free radical ions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Electrospray ionization (ESI) efficiency is known to be affected by the properties of the analytes, source design and source parameters. In this study, the ionization efficiency of 17 acidic compounds at various conditions in ESI negative ion mode was evaluated. Namely, the influence of organic solvent content in the mobile phase, ionization source parameters, ionization source geometry and functionality (conventional ESI, ESI with thermal focussing and with additional internal nebulizer gas) was studied. It was observed that the ionization efficiency in thermal focussing ESI is only marginally affected by the organic solvent composition, while for conventional ESI and ESI with internal nebulizer gas, the ionization efficiency increases significantly with increasing organic modifier content. For all ionization sources and mobile phase compositions, the ionization efficiency values between different setups showed good correlation. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

14.
Metal salen complexes are one of the most frequently used catalysts in enantioselective organic synthesis. In the present work, we compare a series of ionization methods that can be used for the mass spectral analysis of two types of metalosalens: ionic complexes (abbreviated as Com+X?) and neutral complexes (NCom). These methods include electron ionization and field desorption (FD) which can be applied to pure samples and atmospheric pressure ionization techniques: electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) which are suitable for solutions. We found that FD is a method of choice for recording molecular ions of the complexes containing even loosely bonded ligands. The results obtained using atmospheric pressure ionization methods show that the results depend mainly on the structure of metal salen complex and the ionization method. In ESI spectra, Com+ ions were observed, while in APCI and APPI spectra both Com+ and [Com + H]+ ions are observed in the ratio depending on the structure of the metal salen complex and the solvent used in the analysis. For complexes with tetrafluoroborate counterion, an elimination of BF3 took place, and ions corresponding to complexes with fluoride counterion were observed. Experiments comparing the relative sensitivity of ESI, APCI and APPI (with and without a dopant) methods showed that for the majority of the studied complexes ESI is the most sensitive one; however, the sensitivity of APCI is usually less than two times lower and for some compounds is even higher than the sensitivity of ESI. Both methods show very high linearity of the calibration curve in a range of about 3 orders of magnitude of the sample concentration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
The feasibility of atmospheric pressure chemical ionization (APCI) as an alternative ionization technique for capillary electrophoresis-mass spectrometry (CE-MS) was investigated using a grounded sheath-flow CE-MS sprayer and an orthogonal APCI source. Infusion experiments indicated that highest analyte signals were achieved when the sprayer tip was in close vicinity of the vaporizer entrance. The APCI-MS set-up enabled detection of basic, neutral, and acidic compounds, whereas apolar and ionic compounds could not be detected. In the positive ion mode, analytes could be detected in the entire transfer voltage range (0–5 kV), whereas highest signal intensities were observed when the corona discharge current was between 1000 and 2000 nA. In the negative ion mode, the transfer voltage typically was 500 V and the optimum corona discharge current was 6000 nA. Analyte signals were raised with increasing nebulizing gas pressure, but the pressure was limited to 25 psi to avoid siphoning and current drops. Signal intensities appeared to be optimal and constant over a wide range of sheath liquid flow rate (5–25 μL/min) and vaporizer temperature (200–350 °C). APCI-MS signals were unaffected by the composition of the background electrolyte (BGE), even when it contained sodium phosphate and sodium dodecyl sulfate (SDS). Consequently, BGE composition, sheath-liquid flow rate, and vaporizer temperature can be optimized with respect to the CE separation without affecting the APCI-MS response. The analysis of a mixture of basic compounds and a steroid using volatile and nonvolatile BGEs further demonstrates the feasibility of CE-APCI-MS. Detection limits (S/N = 3) were 1. 6–10 μM injected concentrations.  相似文献   

16.
A method for the determination of polymer additives like antioxidants, UV absorbers and processing stabilizers using liquid chromatography (LC) coupled with atmospheric pressure photoionization mass spectrometry (APPI-MS) is presented. Ion source parameters were optimized regarding temperatures, gas flow rates, and voltages applied. Detection limits were determined using APPI with or without dopant and were compared with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). Differences between APPI, ESI and APCI are pointed out and the effect of the dopant toluene and acetone is discussed. The optimized method yielded detection limits between 0.001 mg L−1 and 0.022 mg L−1 for 15 different analytes. Linear calibration plots could be obtained for all solutes over a wide concentration range showing satisfying repeatability with standard deviations of peak areas between 3.4% and 7.6%. The results indicate that the developed method can be regarded as suitable for the quantitative determination of polymer additives even at low concentration levels.  相似文献   

17.
The performance of the atmospheric pressure photoionization (APPI) technique was evaluated against five sets of standards and drug-like compounds and compared to atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The APPI technique was first used to analyze a set of 86 drug standards with diverse structures and polarities with a 100% detection rate. More detailed studies were then performed for another three sets of both drug standards and proprietary drug candidates. All 60 test compounds in these three sets were detected by APPI with an overall higher ionization efficiency than either APCI or ESI. Most of the non-polar compounds in these three sets were not ionized by APCI or ESI. Analysis of a final set of 201 Wyeth proprietary drug candidates by APPI, APCI and ESI provided an additional comparison of the ionization techniques. The detection rates in positive ion mode were 94% for APPI, 84% for APCI, and 84% for ESI. Combining positive and negative ion mode detection, APPI detected 98% of the compounds, while APCI and ESI detected 91%, respectively. This analysis shows that APPI is a valuable tool for day-to-day usage in a pharmaceutical company setting because it is able to successfully ionize more compounds, with greater structural diversity, than the other two ionization techniques. Consequently, APPI could be considered a more universal ionization method, and therefore has great potential in high-throughput drug discovery especially for open access liquid chromatography/mass spectrometry (LC/MS) applications.  相似文献   

18.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
The response of atmospheric pressure chemical ionization (APCI) mass spectrometry to selected polycyclic aromatic compounds (PACs) was examined in a Micromass Quattro atmospheric pressure ion source as a function of both solvents and source gases. Typical PACs found in petroleum samples were represented by mixtures of naphthalene, fluorene, phenanthrene, pyrene, fluoranthene, chrysene, triphenylene, perylene, carbazole, dibenzothiophene, and 9-phenanthrol. A large range of different gases in the APCI source was studied, with emphasis on nitrogen, air, and carbon dioxide. Solvents used included water-acetonitrile, acetonitrile, dichloromethane, and hexanes. The signal responses were dependent on both the gases and solvents used, as was the ionization mechanism, as indicated by the degree of protonation with respect to the level of charge exchange. The combination of carbon dioxide in the nebulizer gas stream with nitrogen in the other streams gave a three- to fourfold better sensitivity than using nitrogen alone for both test mixtures and for complex samples.  相似文献   

20.
In this work, the mass spectrometry behaviour of the veterinary drug family of phenicols, including chloramphenicol (CAP) and its related compounds thiamphenicol (TAP), florfenicol (FF) and FF amine (FFA), was studied. Several atmospheric pressure ionization sources, electrospray (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization were compared. In all atmospheric pressure ionization sources, CAP, TAP and FF were ionized in both positive and negative modes; while for the metabolite FFA, only positive ionization was possible. In general, in positive mode, [M + H]+ dominated the mass spectrum for FFA, while the other compounds, CAP, TAP and FF, with lower proton affinity showed intense adducts with species present in the mobile phase. In negative mode, ESI and atmospheric pressure photoionization showed the deprotonated molecule [M–H]?, while atmospheric pressure chemical ionization provided the radical molecular ion by electron capture. All these ions were characterized by tandem mass spectrometry using the combined information obtained by multistage mass spectrometry and high‐resolution mass spectrometry in a quadrupole‐Orbitrap instrument. In general, the fragmentation occurred via cyclization and losses or fragmentation of the N‐(alkyl)acetamide group, and common fragmentation pathways were established for this family of compounds. A new chemical structure for the product ion at m/z 257 for CAP, on the basis of the MS3 and MS4 spectra is proposed. Thermally assisted ESI and selected reaction monitoring are proposed for the determination of these compounds by ultra high‐performance liquid chromatography coupled to tandem mass spectrometry, achieving instrumental detection limits down to 0.1 pg. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号