首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 29 毫秒
1.
A method for online simultaneous δ2H and δ18O analysis in water by high‐temperature conversion is presented. Water is injected by using a syringe into a high‐temperature carbon reactor and converted into H2 and CO, which are separated by gas chromatography (GC) and carried by helium to the isotope ratio mass spectrometer for hydrogen and oxygen isotope analysis. A series of experiments was conducted to evaluate several issues such as sample size, temperature and memory effects. The δ2H and δ18O values in multiple water standards changed consistently as the reactor temperature increased from 1150 to 1480°C. The δ18O in water can be measured at a lower temperature (e.g. 1150°C) although the precision was relatively poor at temperatures <1300°C. Memory effects exist for δ2H and δ18O between two waters, and can be reduced (to <1%) with proper measures. The injection of different amounts of water may affect the isotope ratio results. For example, in contrast to small injections (100 nL or less) from small syringes (e.g. 1.2 µL), large injections (1 µL or more) from larger syringes (e.g. 10 µL) with dilution produced asymmetric peaks and shifts of isotope ratios, e.g. 4‰ for δ2H and 0.4‰ for δ18O, probably resulting from isotope fractionation during dilution via the ConFlo interface. This method can be used to analyze nanoliter samples of water (e.g. 30 nL) with good precision of 0.5‰ for δ2H and 0.1‰ for δ18O. This is important for geosciences; for instance, fluid inclusions in ancient minerals may be analyzed for δ2H and δ18O to help understand the formation environments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
Revised δ34S reference values with associated expanded uncertainties (95% confidence interval (C.I.)) are presented for the sulfur isotope reference materials IAEA‐S‐2 (22.62 ± 0.16‰) and IAEA‐S‐3 (−32.49 ± 0.16‰). These revised values are determined using two relative‐difference measurement techniques, gas source isotope ratio mass spectrometry (GIRMS) and double‐spike multi‐collector thermal ionization mass spectrometry (MC‐TIMS). Gas analyses have traditionally been considered the most robust for relative isotopic difference measurements of sulfur. The double‐spike MC‐TIMS technique provides an independent method for value‐assignment validation and produces revised values that are both unbiased and more precise than previous value assignments. Unbiased δ34S values are required to anchor the positive and negative end members of the sulfur delta (δ) scale because they are the basis for reporting both δ34S values and the derived mass‐independent Δ33S and Δ36S values. Published in 2009 by John Wiley & Sons, Ltd.  相似文献   

3.
Conventional chemical profiling of methylamphetamine has been used for many years to determine the synthetic route employed and where possible to identify the precursor chemicals used. In this study stable isotope ratio analysis was investigated as a means of determining the origin of the methylamphetamine precursors, ephedrine and pseudoephedrine. Ephedrine and pseudoephedrine may be prepared industrially by several routes. Results are presented for the stable isotope ratios of carbon (δ13C), nitrogen (δ15N) and hydrogen (δ2H) measured in methylamphetamine samples synthesized from ephedrine and pseudoephedrine of known provenance. It is clear from the results that measurement of the δ13C, δ15N and δ2H stable isotope ratios by elemental analyzer/thermal conversion isotope ratio mass spectrometry (EA/TC‐IRMS) in high‐purity methylamphetamine samples will allow determination of the synthetic source of the ephedrine or pseudoephedrine precursor as being either of a natural, semi‐synthetic, or fully synthetic origin. Copyright © 2009 Commonwealth of Australia. Published by John Wiley & Sons, Ltd.  相似文献   

4.
A new analytical technique is described for the determination of δ34S that is comparable to or better than modern gas source mass spectrometry in precision and accuracy, but requires about a factor of 10 less sample. The technique is based on the production of singularly charged arsenic sulfide molecular ions (AsS+) by thermal ionization using silica gel as an emitter and combines multiple‐collector thermal ionization mass spectrometry (MC‐TIMS) with a 33S‐36S double spike to correct instrumental fractionation. Three international sulfur standards (IAEA‐S‐1, IAEA‐S‐2, and IAEA‐S‐3) were measured to evaluate the precision and accuracy of the new technique and to evaluate the consensus values for these standards. Two different double spike preparations were used. The δ34S values (reported relative to Vienna Canyon Diablo Troilite (VCDT), (δ34S (‰) = ([((34S/32S)sample/(34S/32S)VCDT ? 1) × 1000]), 34S/32SVCDT = 0.0441626) determined were ?0.32 ± 0.04‰ (1σ, n = 4) and ?0.31 ± 0.13‰ (1σ, n = 8) for IAEA‐S‐1, 22.65 ± 0.04‰ (1σ, n = 7) and 22.60 ± 0.06‰ (1σ, n = 5) for IAEA‐S‐2, and ?32.47 ± 0.07‰ (1σ, n = 8) for IAEA‐S‐3. The amount of natural sample used for these analyses ranged from 0.40 to 2.35 µmol. Replicate determinations of each standard showed less than 0.5‰ variability (IAEA‐S‐1 <0.4‰, IAEA‐S‐2 <0.2‰, and IAEA‐S‐3 <0.2‰). Because the technique is based on thermal ionization of AsS+, and As is mononuclidic, corrections for interferences or for scale contraction/expansion are not required. The availability of MC‐TIMS instruments in laboratories around the world makes this technique immediately available to a much larger scientific community who require highly accurate and precise measurements of sulfur. Published in 2005 by John Wiley & Sons, Ltd.  相似文献   

5.
We present a method for in situ sulphur (S) isotopic analysis of significantly small areas (1.5 µm in diameter) in pyrite using secondary ion mass spectrometry (NanoSIMS) to interpret microbial sulphur metabolism in the early earth. We evaluated the precision and accuracy of S isotopic ratios obtained by this method using hydrothermal pyrite samples with homogeneous S isotopic ratios. The internal precision of the δ34S value was 1.5‰ at the level of 1 sigma of standard error (named 1SE) for a single spot, while the external reproducibility was estimated to be 1.6‰ at the level of 1 sigma of standard deviation (named 1SD, n = 25). For each separate sample, the average δ34S value was comparable with that measured by a conventional method, and the accuracy was better than 2.3‰. Consequently, the in situ method is sufficiently accurate and precise to detect the S isotopic variations of small sample of the pyrite (less than 20 µm) that occurs ubiquitously in ancient sedimentary rocks. This method was applied to measure the S isotopic distribution of pyrite within black chert fragments in early Archean sandstone. The pyrite had isotopic zoning with a 34S‐depleted core and 34S‐enriched rim, suggesting isotopic evolution of the source H2S from ?15 to ?5‰. Production of H2S by microbial sulphate reduction (MSR) in a closed system provides a possible explanation for both the 34S‐depleted initial H2S and the progressive increase in the δ34SH2S value. Although more extensive data are necessary to strengthen the explanation for the origin of the MSR, the results show that the S isotopic distribution within pyrite crystals may be a key tracer for MSR activity in the early earth. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high‐temperature conversion techniques (HTC) a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:
Reference material δ18O and estimated combined uncertainty c
IAEA‐602 benzoic acid +71.28 ± 0.36‰
USGS35 sodium nitrate +56.81 ± 0.31‰
IAEA‐NO‐3 potassium nitrate +25.32 ± 0.29‰
IAEA‐601 benzoic acid +23.14 ± 0.19‰
IAEA‐SO‐5 barium sulfate +12.13 ± 0.33‰
NBS 127 barium sulfate +8.59 ± 0.26‰
VSMOW2 water 0‰
IAEA‐600 caffeine ?3.48 ± 0.53‰
IAEA‐SO‐6 barium sulfate ?11.35 ± 0.31‰
USGS34 potassium nitrate ?27.78 ± 0.37‰
SLAP water ?55.5‰
The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3‐fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen‐isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA‐NO‐3, and USGS35), sulfates (IAEA‐SO‐5, IAEA‐SO‐6, and NBS 127), or organic material (IAEA‐601 benzoic acid, IAEA‐602 benzoic acid, and IAEA‐600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the δ18O values at a later time should it become necessary. The high‐temperature reduction technique for analyzing δ18O and δ2H is not as widely applicable as the well‐established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
We have developed a rapid, sensitive, and automated analytical system to simultaneously determine the concentrations and stable isotopic compositions (δ15N, δ18O, and δ13C) of nanomolar quantities of nitrous oxide (N2O) and methane (CH4) in water, by combining continuous‐flow isotope‐ratio mass spectrometry and a helium‐sparging system to extract and purify the dissolved gases. Our system, which is composed of cold traps and a capillary gas chromatograph that use ultra‐pure helium as the carrier gas, achieves complete extraction of N2O and CH4 in a water sample and separation among N2O, CH4, and the other component gases. The flow path following exit from the gas chromatograph was periodically changed to pass the gases through the combustion furnace to convert CH4 and the other hydrocarbons into CO2, or to bypass the combustion furnace for the direct introduction of eluted N2O into the mass spectrometer, for determining the stable isotopic compositions through monitoring the ions of m/z 44, 45, and 46 of CO and N2O+. The analytical system can be operated automatically with sequential software programmed on a personal computer. Analytical precisions better than 0.2‰ and 0.3‰ and better than 1.4‰ and 2.6‰ were obtained for the δ15N and δ18O of N2O, respectively, when more than 6.7 nmol and 0.2 nmol of N2O, respectively, were injected. Simultaneously, analytical precisions better than 0.07‰ and 2.1‰ were obtained for the δ13C of CH4 when more than 5.5 nmol and 0.02 nmol of CH4, respectively, were injected. In this manner, we can simultaneously determine stable isotopic compositions of a 120 mL water sample with concentrations as low as 1.7 nmol/kg for N2O and 0.2 nmol/kg for CH4. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
High frequency observations of the stable isotopic composition of CO2 effluxes from soil have been sparse due in part to measurement challenges. We have developed an open‐system method that utilizes a flow‐through chamber coupled to a tunable diode laser (TDL) to quantify the rate of soil CO2 efflux and its δ13C and δ18O values (δ13CR and δ18OR, respectively). We tested the method first in the laboratory using an artificial soil test column and then in a semi‐arid woodland. We found that the CO2 efflux rates of 1.2 to 7.3 µmol m?2 s?1 measured by the chamber‐TDL system were similar to measurements made using the chamber and an infrared gas analyzer (IRGA) (R2 = 0.99) and compared well with efflux rates generated from the soil test column (R2 = 0.94). Measured δ13C and δ18O values of CO2 efflux using the chamber‐TDL system at 2 min intervals were not significantly different from source air values across all efflux rates after accounting for diffusive enrichment. Field measurements during drought demonstrated a strong dependency of CO2 efflux and isotopic composition on soil water content. Addition of water to the soil beneath the chamber resulted in average changes of +6.9 µmol m?2 s?1, ?5.0‰, and ?55.0‰ for soil CO2 efflux, δ13CR and δ18OR, respectively. All three variables initiated responses within 2 min of water addition, with peak responses observed within 10 min for isotopes and 20 min for efflux. The observed δ18OR was more enriched than predicted from temperature‐dependent H2O‐CO2 equilibration theory, similar to other recent observations of δ18OR from dry soils (Wingate L, Seibt U, Maseyk K, Ogee J, Almeida P, Yakir D, Pereira JS, Mencuccini M. Global Change Biol. 2008; 14: 2178). The soil chamber coupled with the TDL was found to be an effective method for capturing soil CO2 efflux and its stable isotope composition at high temporal frequency. Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

9.
Variations in natural abundance of carbon (C) and nitrogen (N) stable isotopes are widely used as tools for many aspects of scientific research. By examining variations in the ratios of heavy to light stable isotopes, information can be obtained as to what physical, chemical and biological processes may be occurring. The spatial heterogeneity of soil δ15N‐ and δ13C‐values across a range of scales and under different land use have been described by a number of researchers and the natural abundances of the C and N stable isotopes in soils have been found to be correlated with many factors including hydrology, topography, land use, vegetation cover and climate. In this study the Latin square sampling +1 (LSS+1) sampling method was compared with a simple grid sampling approach for δ13C and δ15N measurement at the field scale. A set of 144 samples was collected and analysed for δ15N and δ13C from a 12 × 12 grid (in a 1 ha improved grassland field in south‐west England). The dimension of each cell of the grid was approximately 11 × 6 m. The 12 × 12 grid was divided into four 6 × 6 grids and the LSS+1 sampling technique was applied to these and the main 12 × 12 grid for a comparison of sample means and variation. The LSS+1 means from the 12 × 12 grid and the four 6 × 6 grids compared well with the overall grid mean because of the low variation within the field. The LSS+1 strategy (13 samples) generated representative samples from the 12 × 12 grid, and hence would be an acceptable method for sampling similar plots for the measurement of mean isotopic composition. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
An analytical line for stable isotope analyses of water recovered from fluid inclusions in minerals was built and successfully tested. The line is based on the principle of continuous‐flow analysis of water via high‐temperature reduction on glassy carbon. It includes a custom‐designed set of high‐efficiency crushers and a cryo‐focusing cell. This paper provides details of the line design and discusses strategies for line conditioning and mitigation of memory effects. The line allows measurements of hydrogen and oxygen isotopes during a single acquisition. The precision of the analyses depends on the amount of water released from the inclusions. The best results are obtained for samples containing at least 0.1–0.2 µL (0.06–0.11 µmol) H2O. For such samples precision is better than 1.5‰ for δD and 0.5‰ for δ18O (1σ). Smaller amounts of water can be measured but at lower precision. Analyses of modern calcite formed under stable conditions in a deep cave allowed assessment of the accuracy of the analyses. The δD values measured in fluid inclusions of this working standard match the δD value of the parent water, and the oxygen isotope values agree within ca. 0.5‰. This indicates that fluid inclusions trapped in calcite at near‐ambient temperatures (e.g. speleothems and low‐temperatures phreatic calcite) faithfully preserve the original isotopic composition of the parent waters. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
The stable oxygen isotope signature (δ18O) of soil is expected to be the result of a mixture of components within the soil with varying δ18O signatures. Thus, the δ18O of soils should provide information about the soil's substrate, especially about the relative contribution of organic matter versus minerals. As there is no standard method available for measuring soil δ18O, the method for the measurement of single components using a high‐temperature conversion elemental analyser (TC/EA) was adapted. We measured δ18O in standard materials (IAEA 601, IAEA 602, Merck cellulose) and soils (organic and mineral soils) in order to determine a suitable pyrolysis temperature for soil analysis. We consider a pyrolysis temperature suitable when the yield of signal intensity (intensity of mass 28 per 100 µg) is at a maximum and the acquired raw δ18O signature is constant for the standard materials used and when the quartz signal from the soil is still negligible. After testing several substances within the temperature range of 1075 to 1375°C we decided to use a pyrolysis temperature of 1325°C for further measurements. For the Urseren Valley we have found a sequence of increasing δ18O signatures from phyllosilicates to upland soils, wetland soils and vegetation. Our measurements show that the δ18O values of upland soil samples differ significantly from wetland soil samples. The latter can be related to the changing mixing ratio of the mineral and organic constituents of the soil. For wetlands affected by soil erosion, we have found intermediate δ18O signatures which lie between typical signatures for upland and wetland sites and give evidence for the input of upland soil material through erosion. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
Methionine is an essential amino acid and is the primary source of sulfur for humans. Using the double spike (33S‐36S) multi‐collector thermal ionization mass spectrometry (MC‐TIMS) technique, three sample bottles of a methionine material obtained from the Institute for Reference Materials and Measurements have been measured for δ34S and sulfur concentration. The mean δ34S value, relative to Vienna Canyon Diablo Troilite (VCDT), determined was 10.34 ± 0.11‰ (n = 9) with the uncertainty reported as expanded uncertainties (U). These δ34S measurements include a correction for blank which has been previously ignored in studies of sulfur isotopic composition. The sulfur concentrations for the three bottles range from 56 to 88 µg/g. The isotope composition and concentration results demonstrate the high accuracy and precision of the DS‐MC‐TIMS technique for measuring sulfur in methionine. Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

13.
The measurement of the oxygen stable isotope content in organic compounds has applications in many fields, ranging from paleoclimate reconstruction to forensics. Conventional High‐Temperature Conversion (HTC) techniques require >20 µg of O for a single δ18O measurement. Here we describe a system that converts the CO produced by HTC into CO2 via reduction within a Ni‐furnace. This CO2 is then concentrated cryogenically, and 'focused' into the isotope ratio mass spectrometry (IRMS) source using a low‐flow He carrier gas (6–8 mL/min). We report analyses of benzoic acid (C7H6O2) reference materials that yielded precise δ18O measurement down to 1.3 µg of O, suggesting that our system could be used to decrease sample requirement for δ18O by more than an order of magnitude. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Many laboratories routinely analyze plant, animal and soil samples with elemental analyzers coupled to isotope ratio mass spectrometers, obtaining rapid results for nitrogen (%N, δ15N) and carbon (%C, δ13C) from the same sample. The coupled N and C measurements are possible because of a gas chromatography (GC) separation of N2 and CO2 gases produced in elemental analysis. Adding a second GC column allows additional measurement of sulfur (%S, δ34S) from the same sample, so that combined N, C and S information is obtained routinely. Samples are 1–15 mg, and replicates generally differ by less than 0.1‰ for δ15N, δ13C or δ34S. An example application shows that the N, C, and S measurement system allows a three‐dimensional view of element dynamics in estuarine systems that are undergoing pollution inputs from upstream watersheds. Extension of these GC principles should allow coupled H, C, N, and S isotope measurements in future work. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

15.
An online method using continuous flow isotope ratio mass spectrometry (CF‐IRMS) interfaced with a Gasbench II device was established to analyze carbon and oxygen isotopic compositions and to estimate the content of minor amounts of carbonate in silicate rocks. The mixtures of standard materials and high‐purity quartz are firstly used to calibrate different quantities of carbonate in silicates. The results suggest that the accuracy and precision of the online analysis are both better than those obtained using an offline method. There is a positive correlation between the carbonate weight and the Mass44 ion beam intensity (or peak area). When the weight of carbonate in the mixtures is greater than 70 µg (equal to ~1800 mV Mass44 ion beam intensity), the δ13C and δ18O values of samples usually have accuracy and precision of ±0.1‰ and ±0.2‰ (1σ), respectively. If the weight is less than 70 µg, some limitations (e.g., not perfectly linear) are encountered that significantly reduce the accuracy and precision. The measured δ18O values are systematically lower than the true values by ?0.3 to ?0.7‰; the lower the carbonate content, the lower the measured δ18O value. For samples with lower carbonate content, the required phosphoric acid doses are higher and more oxygen isotope exchanges with the water in the phosphoric acid. To guarantee accurate results with high precision, multiple analyses of in‐house standards and an artificial MERCK sample with δ13C values from ?35.58 to 1.61‰ and δ18O from 6.04 to 18.96‰ were analyzed simultaneously with the unknown sample. This enables correction of the measured raw data for the natural sample based on multiple‐point normalization. The results indicate that the method can be successfully applied to a range of natural rocks. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
Isoprene is one of the most important non‐methane hydrocarbons (NMHCs) in the troposphere: it is a significant precursor of O3 and it affects the oxidative state of the atmosphere. The diastereoisomeric 2‐methyltetrols, 2‐methylthreitol and 2‐methylerythritol, are marker compounds of the photooxidation products of atmospheric isoprene. In order to obtain valuable information on the δ13C value of isoprene in the atmosphere, the stable carbon isotopic compositions of the 2‐methyltetrols in ambient aerosols were investigated. The 2‐methyltetrols were extracted from filter samples and derivatized with methylboronic acid, and the δ13C values of the methylboronate derivatives were determined by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The δ13C values of the 2‐methyltetrols were then calculated through a simple mass balance equation between the 2‐methyltetrols, methylboronic acid and the methylboronates. The δ13C values of the 2‐methyltetrols in aerosol samples collected at the Changbai Mountain Nature Reserves in eastern China were found to be ?24.66 ± 0.90‰ and ?24.53 ± 1.08‰ for 2‐methylerythritol and 2‐methylthreitol, respectively. Based on the measured isotopic composition of the 2‐methyltetrols, the average δ13C value of atmospheric isoprene is inferred to be close to or slightly heavier than ?24.66‰ at the collection site during the sampling period. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
Squalene and its hydrogenated derivate squalane are widely used in the pharmaceutical and cosmetic fields. The two compounds are mainly produced from the liver oil of deep sea sharks and from olive oil distillates. Squalene and squalane from shark cost less than the same compounds derived from olive oil, and the use of these shark‐derived compounds is unethical in cosmetic formulations. In this work we investigate whether 13C/12C and 2H/1H ratios can distinguish olive oil from shark squalene/squalane and can detect the presence of shark derivates in olive oil based products. The 13C/12C ratios (expressed as δ13C values) of bulk samples and of pure compounds measured using isotope ratio mass spectrometry (IRMS) were significantly lower in authentic olive oil squalene/squalane (N: 13; ?28.4 ± 0.5‰; ?28.3 ± 0.8‰) than in shark squalene/squalane samples (N: 15; ?20.5 ± 0.7‰; ?20.4 ± 0.6‰). By defining δ13C threshold values of ?27.4‰ and ?26.6‰ for olive oil bulk and pure squalene/squalane, respectively, illegal addition of shark products can be identified starting from a minimum of 10%. 2H/1H analysis is not useful for distinguishing the two different origins. δ13C analysis is proposed as a suitable tool for detecting the authenticity of commercial olive oil squalene and squalane samples, using IRMS interfaced to an elemental analyser if the purity is higher than 80% and IRMS interfaced to a gas chromatography/combustion system for samples with lower purity, including solutions of squalane extracted from cosmetic products. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
19.
Gas chromatography‐combustion‐isotope ratio mass spectrometry (GC‐C‐IRMS) is increasingly applied to food and metabolic studies for stable isotope analysis (δ13C), with the quantification of analyte concentration often obtained via a second alternative method. We describe a rapid direct transesterification of triacylglycerides (TAGs) for fatty acid methyl ester (FAME) analysis by GC‐C‐IRMS demonstrating robust simultaneous quantification of amount of analyte (mean r2 = 0.99, accuracy ±2% for 37 FAMEs) and δ13C (±0.13‰) in a single analytical run. The maximum FAME yield and optimal δ13C values are obtained by derivatizing with 10% (v/v) acetyl chloride in methanol for 1 h, while lower levels of acetyl chloride and shorter reaction times skewed the δ13C values by as much as 0.80‰. A Bland‐Altman evaluation of the GC‐C‐IRMS measurements resulted in excellent agreement for pure oils (±0.08‰) and oils extracted from French fries (±0.49‰), demonstrating reliable simultaneous quantification of FAME concentration and δ13C values. Thus, we conclude that for studies requiring both the quantification of analyte and δ13C data, such as authentication or metabolic flux studies, GC‐C‐IRMS can be used as the sole analytical method. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
The 18O and 2H of water vapor serve as powerful tracers of hydrological processes. The typical method for determining water vapor δ18O and δ2H involves cryogenic trapping and isotope ratio mass spectrometry. Even with recent technical advances, these methods cannot resolve vapor composition at high temporal resolutions. In recent years, a few groups have developed continuous laser absorption spectroscopy (LAS) approaches for measuring δ18O and δ2H which achieve accuracy levels similar to those of lab‐based mass spectrometry methods. Unfortunately, most LAS systems need cryogenic cooling and constant calibration to a reference gas, and have substantial power requirements, making them unsuitable for long‐term field deployment at remote field sites. A new method called Off‐Axis Integrated Cavity Output Spectroscopy (OA‐ICOS) has been developed which requires extremely low‐energy consumption and neither reference gas nor cryogenic cooling. In this report, we develop a relatively simple pumping system coupled to a dew point generator to calibrate an ICOS‐based instrument (Los Gatos Research Water Vapor Isotope Analyzer (WVIA) DLT‐100) under various pressures using liquid water with known isotopic signatures. Results show that the WVIA can be successfully calibrated using this customized system for different pressure settings, which ensure that this instrument can be combined with other gas‐sampling systems. The precisions of this instrument and the associated calibration method can reach ~0.08‰ for δ18O and ~0.4‰ for δ2H. Compared with conventional mass spectrometry and other LAS‐based methods, the OA‐ICOS technique provides a promising alternative tool for continuous water vapor isotopic measurements in field deployments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号