首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, sensitive, and reliable liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of pyraoxystrobin in rat plasma and applied to a toxicokinetics study. The separation was performed by gradient elution on a Luna 5 μ C18 (2) 100 Å column (50?×?4.6 mm I.D., 5 μm) with mobile phase: water (0.1 % formic acid, v/v)/acetonitrile (0.1 % formic acid, v/v), followed by quantification with a mass detector in multiple reaction monitoring (MRM) mode using ESI as an interface. The calibration curve was linear over a concentration range of 1.00–200 ng/mL. The recovery for pyraoxystrobin ranged from 101.4 to 108.2 %. The intraday bias and precision ranged from ?9.3 to 8.1 % and from 0.7 to 8.4 %, respectively, and the interday bias and precision ranged from ?0.3 to 4.0 % and from 4.4 to 7.2 %, respectively. The toxicokinetics of pyraoxystrobin after single 100 and 1,000 mg/kg oral doses were studied in rats. Figure
The chromatogram of pyraoxystrobin highest calibration standard (ULOQ) extract.  相似文献   

2.
We are presenting magnetic molecularly imprinted polymer nanoparticles (m-MIPs) for solid-phase extraction and sample clean-up of paracetamol. The m-MIPs were prepared from magnetite (Fe3O4) as the magnetic component, paracetamol as the template, methacrylic acid as a functional monomer, and 2-(methacrylamido) ethyl methacrylate as a cross-linker. The m-MIPs were then characterized by transmission electron microscopy, FT-IR spectroscopy, X-ray diffraction and vibrating sample magnetometry. The m-MIPs were applied to the extraction of paracetamol from human blood plasma samples. Following its elution from the column loaded with the m-MIPs with an acetonitrile-buffer (9:1) mixture, it was submitted to HPLC analysis. Paracetamol can be quantified by this method in the 1 μg L?1 to 300 μg L?1 concentration range. The limit of detection and limit of quantification in plasma samples are 0.17 and 0.4 μg L?1. The preconcentration factor of the m-MIPs is 40. The HPLC method shows good precision (4.5 % at 50 μg L?1 levels) and recoveries (between 83 and 91 %) from spiked plasma samples. Figure
We are presenting magnetic molecularly imprinted polymer nanoparticles (m-MIPs) for solid-phase extraction and sample clean-up of paracetamol. The m-MIPs were applied to the extraction of paracetamol from human blood plasma samples  相似文献   

3.
A new method for the growth-dependent headspace analysis of bacterial cultures by needle trap (NT)-gas chromatography-mass spectrometry (GC-MS) was established. NTs were used for the first time as enrichment technique for volatile organic compounds (VOCs) in the headspace of laboratory cultures. Reference strains of Escherichia coli and Pseudomonas aeruginosa were grown in different liquid culture media for 48 h at 36 °C. In the course of growth, bacterial culture headspace was analysed by NT-GC-MS. In parallel, the abiotic release of volatile organic compounds (VOC) from nutrient media was investigated by the same method. By examination of microbial headspace samples in comparison with those of uninoculated media, it could be clearly differentiated between products and compounds which serve as substrates. Specific microbial metabolites were detected and quantified during the stationary growth phase. P. aeruginosa produced dimethyl sulfide (max. 125 μg L?1??1) and 2-nonanone (max. 200 μg L?1), whereas E. coli produced carbon disulfide, butanal and indole (max. 149 mg L?1). Both organisms produced isoprene. Graphical Abstract
MVOCs produced by P. aeruginosa and E. coli at T = 36 °C in autoclaved LB + TRP medium   相似文献   

4.
We present a novel lateral flow immunoassay (LFIA) for the simultaneous detection of the pesticides imidacloprid, chlorpyrifos-methyl and isocarbophos based on three competitive immunoreactions. In contrast to previously reported LFIAs, the method is based on the use of four strips. Each has three red channels (three test lines dispensed with different capture reagent) to detect imidacloprid, chlorpyrifos-methyl and isocarbophos respectively. Different channels on each strip are the key to multi-detection, and four strips of LFIA are needed for visual and semi-quantitative read-outs. Under optimized conditions, the LFIA was applied to the determination of three pesticides. The detection time is within 7 min and the detection limits are 50, 100, and 100 μg L?1, respectively. Furthermore, the LFIA was applied to the analysis of spiked Chinese cabbage and soil samples and results were validated by HPLC. Figure
Design of the Lateral Flow Immunoassay. The LFIA made up of four strips (Strip 1 to Strip 4), and each strip dispensed with three kinds of capture antigens on different channels (CH1 to CH3)  相似文献   

5.
An electrochemical sensor was developed and tested for detection of L-tyrosine in the presence of epinephrine by surface modification of a glassy carbon electrode (GCE) with Nafion and cerium dioxide nanoparticles. Fabrication parameters of a surfactant-assisted precipitation method were optimized to produce 2–3 nm CeO2 nanoparticles with very high surface-to-volume ratio. The resulting nanocrystals were characterized structurally and morphologically by X-ray diffractometery (XRD), scanning and high resolution transmission electron microscopy (SEM and HR-TEM). The nanopowder is sonochemically dispersed in a Nafion solution which is then used to modify the surface of a GCE electrode. The electrochemical activity of L-tyrosine and epinephrine was investigated using both a Nafion-CeO2 coated and a bare GCE. The modified electrode exhibits a significant electrochemical oxidation effect of L-tyrosine in a 0.2 M Britton-Robinson (B-R) buffer solution of pH 2. The electro-oxidation peak current increases linearly with the L-tyrosine concentration in the molar concentration range of 2 to 160 μM. By employing differential pulse voltammetry (DPV) for simultaneous measurements, we detected two reproducible peaks for L-tyrosine and epinephrine in the same solution with a peak separation of about 443 mV. The detection limit of the sensor (signal to noise ratio of 3) for L-tyrosine is ~90 nM and the sensitivity is 0.20 μA μM?1, while for epinephrine these values are ~60 nM and 0.19 μA μM?1. The sensor exhibited excellent selectivity, sensitivity, reproducibility and stability as well as a very good recovery time in real human blood serum samples.
Simultaneous electrochemical determination of L-tyrosine and epinephrine in blood plasma with Nafion-CeO2/GCE modified electrode showing a 443 mV peak-to-peak potential difference between species oxidation peak currents.  相似文献   

6.
A glassy carbon electrode was modified with gold nanoparticles (Au-NPs) on a quaternized cellulose support in a film composed of poly(ethylene glycol diglycidyl ether) (PEGDGE), and Hb was immobilized on the Au-NPs. The sensor film was characterized by UV–vis spectra, scanning electron microscopy, and electrochemical impedance spectroscopy. Cyclic voltammetry of the Hb in the Au@Qc/PEGDGE film revealed a pair of well-defined and quasi reversible peaks for the protein heme Fe(III)/Fe(II) redox couple at about ?0.333 V (vs. SCE). The sensor film also exhibited good electrocatalytic activity for the reduction of nitric oxide and hydrogen peroxide. The amperometric response of the biosensor depends linearly on the concentration of nitric oxide in the 0.9 to 160 μM range, and the detection limit is as low as 12 nM (at 3σ). The response to hydrogen peroxide is linear in the 59 nM to 4.6 μM concentration range, and the detection limit is 16 nM (at 3σ). This biosensor is sensitive, reproducible, and long-term stable. Figure
An electrochemical biosensor based on the immobilization of hemoglobin in Au@Qc NPs /Poly ethylene glycol diglycidyl ether composite film is developed.  相似文献   

7.
Hexafluoroisopropanol (HFIP)-induced coacervation in aqueous mixed systems of catanionic surfactants of dodecyltrimethylammonium bromide (DTAB) and sodium dodecyl sulfate (SDS) was described in detail, and its application in the extraction of strongly polar sulfonamides (SAs) was investigated. With 10 % (v/v) HFIP inclusion, coacervation formation and two-phase separation occur in a wide range of SDS/DTAB mole ratios (88:12~0:100 mol/mol) and total surfactant concentrations (10~200 mmol/L). The interactions between HFIP and DTAB play an important role in coacervation formation. The HFIP-induced SDS–DTAB coacervation extraction proves to be an efficient method for the extraction and preconcentration of SAs. Both hydrophobic interaction and polar interactions (hydrogen–bond, electrostatic, and π-cation) contribute to the distribution of SAs into coacervate phase. The proposed HFIP-induced SDS–DTAB coacervation extraction combined with HPLC–UV was employed for the extraction and quantitative determination of SAs in environmental water samples. Limits of detection were 1.4~2.5 ng mL?1. Excellent linearity with correlation coefficients from 0.9990 to 0.9995 was obtained in the concentration of 0.01~10 μg mL?1. Relative recoveries were in the range of 93.4~105.9 % for analysis of the lake, underground, and tap water samples spiked with SAs at 0.01, 1.0, and 10 μg/mL, respectively. Relative standard deviations were 0.7~3.2 % for intraday precision and 1.3~4.6 % for interday precision (n?=?3). Concentration factors were 17~49 for three water samples spiked with 0.01 μg/mL SAs. The results demonstrate that the proposed extraction method is feasible for the preconcentration and determination of trace SAs in real water samples. Graphical abstract
?  相似文献   

8.
This work describes a novel polyaniline-magnetite nanocomposite and its application to the preconcentration of Cr(VI) anions. The material was obtained by oxidative polymerization of aniline in the presence of magnetite nanoparticles. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Extraction time, amount of magnetic sorbent and pH value were selected as the main factors affecting sorption. The sorption capacity of the sorbent for Cr(VI) is 54 mg g?1. The type, volume and concentration of the eluents, and the elution time were selected as main factors in the optimization study of the elution step. Following sorption and elution, the Cr(VI) ions were reacted with diphenylcarbazide, and the resulting dye was quantified by HPLC with optical detection at 546 nm. The limit of detection is 0.1 μg L?1, and all the relative standard deviations are <6.3 %. The nanocomposite was successfully applied to the rapid extraction and determination of trace quantities of Cr(VI) ions in spiked water samples. Figure
A schematic procedure of magnetic solid phase extraction  相似文献   

9.
We describe a hybrid MALDI/C60-SIMS Q-TOF mass spectrometer and corresponding sample preparation protocols to image intact biomolecules and their fragments in mammalian spinal cord, individual invertebrate neurons, and cultured neuronal networks. A lateral spatial resolution of 10 μm was demonstrated, with further improvement feasible to 1 μm, sufficient to resolve cell outgrowth and interconnections in neuronal networks. The high mass resolution (>13,000 FWHM) and tandem mass spectrometry capability of this hybrid instrument enabled the confident identification of cellular metabolites. Sublimation of a suitable matrix, 2,5-dihydroxybenzoic acid, significantly enhanced the ion signal intensity for intact glycerophospholipid ions from mammalian nervous tissue, facilitating the acquisition of high-quality ion images for low-abundance biomolecules. These results illustrate that the combination of C60-SIMS and MALDI mass spectrometry offers particular benefits for studies that require the imaging of intact biomolecules with high spatial and mass resolution, such as investigations of single cells, subcellular organelles, and communities of cells. Graphical Abstract
?  相似文献   

10.
A proficiency test for the analysis of pesticide residues in brown rice was carried out to support upgrading in analytical skills of participant laboratories. Brown rice containing three target pesticides (etofenprox, fenitrothion, and isoprothiolane) was used as the test samples. The test samples were distributed to the 57 participants and analyzed by appropriate analytical methods chosen by each participant. It was shown that there was no significant difference among the reported values obtained by different types of analytical method. The analytical results obtained by National Metrology Institute of Japan (NMIJ) were 3 % to 10 % greater than those obtained by participants. The results reported by the participant were evaluated by using two types of z-scores, that is, one was the score based on the consensus values calculated from the analytical results of participants, and the other one was the score based on the reference values obtained by NMIJ with high reliability. Acceptable z-scores based on the consensus values and NMIJ reference values were achieved by 87 % to 89 % and 79 % to 94 % of the participants, respectively. Graphical Abstract
Distribution of z and zNMIJ-scores for isoprothiolane  相似文献   

11.
A sensitive and selective analytical method, based on online solid phase extraction coupled to LC–MS/MS, was developed and validated to determine traces of several recently introduced fungicides in surface water and wastewater. The list of target analytes included eight succinate dehydrogenase inhibitors (bixafen, boscalid, fluopyram, flutolanil, fluxapyroxad, isopyrazam, penflufen, and penthiopyrad), and two other fungicides with different modes of action, fenpyrazamine and fluopicolide. Detection and quantification limits in various matrices were in the range of 0.1 to 2 and 0.5 to 10 ng/L, respectively. Moderate signal suppression was observed in surface water (≤15 %) and wastewater (≤25 %) and was well compensated by the selected internal standard. The intra- and inter-day precisions were generally <10 and <20 %, respectively. The applicability of the method was demonstrated in a study on the occurrence of fungicides in the river Glatt, Switzerland, that drains a catchment area of 419 km2 with a substantial proportion of agricultural land. Of the studied compounds, only boscalid and fluopicolide were detected in flow-proportional weekly composite samples, generally at low concentrations up to 15 and 5 ng/L, respectively. While fluopicolide was detected in only 30 % of the samples above the LOD of 0.5 ng/L, boscalid was detected in all samples analyzed between March and October 2012. Graphical Abstract
Concentration of the fungicides boscalid and fluopicolide in flow-proportional weekly-composite watersamples from River Glatt, Switzerland in 2012  相似文献   

12.
Xanthine oxidase (XOD) catalyzes the metabolism of hypoxanthine and xanthine to uric acid, the overproduction of which could cause hyperuricemia, a risk factor for gout. Inhibition of XOD is a major treatment for gout, and biflavonoids have been found to act as XOD-inhibitory compounds. In this study, ultrafiltration liquid chromatography with photodiode-array detection coupled to electrospray-ionization tandem mass spectrometry (UF-LC-PDA–ESI-MS) was used to screen and identify XOD inhibitors from S. tamariscina. High-performance counter-current chromatography (HPCCC) was used to separate and isolate the active constituents of these XOD inhibitors. Furthermore, ultrahigh-performance liquid chromatography (UPLC) and triple-quadrupole mass spectrometry (TQ-MS) was used to determine the XOD-inhibitory activity of the obtained XOD inhibitors, and enzyme kinetics was performed with Lineweaver–Burk (LB) plots using xanthine as the substrate. As a result, two compounds in S. tamariscina were screened as XOD inhibitors: 65.31 mg amentoflavone and 0.76 mg robustaflavone were isolated from approximately 2.5 g?S. tamariscina by use of HPCCC. The purities of the two compounds obtained were over 98 % and 95 %, respectively, as determined by high-performance liquid chromatography (HPLC). Lineweaver–Burk plot analysis indicated that amentoflavone and robustaflavone were non-competitive inhibitors of XOD, and the IC 50 values of amentoflavone and robustaflavone for XOD inhibition were 16.26 μg mL?1 (30.22 μmol L?1) and 11.98 μg mL?1 (22.27 μmol L?1), respectively. The IC 50 value of allopurinol, used as the standard, was 7.49 μg mL?1 (46.23 μmol L?1). The results reveal that the method for systematic screening, identification, and isolation of bioactive components in S. tamariscina and for detecting their inhibitory activity using ultrafiltration LC–ESI-MS, HPCCC, and UPLC–TQ-MS is feasible and efficient, and could be expected to extend to screening and separation of other enzyme inhibitors. Graphical Abstract
?  相似文献   

13.
This review covers recent advances in sampling fluid from the extracellular space of brain tissue by electroosmosis (EO). Two techniques, EO sampling with a single fused-silica capillary and EO push–pull perfusion, have been developed. These tools were used to investigate the function of membrane-bound enzymes with outward-facing active sites, or ectoenzymes, in modulating the activity of the neuropeptides leu-enkephalin and galanin in organotypic-hippocampal-slice cultures (OHSCs). In addition, the approach was used to determine the endogenous concentration of a thiol, cysteamine, in OHSCs. We have also investigated the degradation of coenzyme A in the extracellular space. The approach provides information on ectoenzyme activity, including Michaelis constants, in tissue, which, as far as we are aware, has not been done before. On the basis of computational evidence, EO push–pull perfusion can distinguish ectoenzyme activity with a ~100 μm spatial resolution, which is important for studies of enzyme kinetics in adjacent regions of the rat hippocampus. Graphical Abstract
Schematics for the one-probe electroosmotic sampling (EO sampling, left) and two-probe electroosmotic push-pull perfusion techniques (EOPPP, right). An external electric field drives fluid flow in the direction indicated by the arrows. HBSS - Hanks Balanced Salt Solution.  相似文献   

14.
Flow injection combined with tandem mass spectrometry (MS/MS) was investigated for the rapid detection of highly polar pesticides that are not amenable to multi-residue methods because they do not partition into organic solvents and require dedicated chromatographic conditions. The pesticides included in this study were amitrole, chlormequat, cyromazine, daminozide, diquat, ethephon, fosetyl-Al, glufosinate, glyphosate and its metabolite aminomethylphosphonic acid, maleic hydrazide, mepiquat and paraquat. The composition of the flow-injection solvent was optimized to achieve maximum MS/MS sensitivity. Instrumental limits of detection varied between <0.05 and 1 pg. Fruit, vegetable, cereal, milk and kidney samples were extracted with water (1 % formic acid in case of paraquat/diquat) and ten times diluted in either methanol/0.1 % formic acid, methanol/0.1 % ammonia or acetonitrile/0.1 % ammonia, depending on the pesticide. The ion suppression observed depended strongly on both the matrix and the pesticide. This could be largely compensated for by matrix-matched calibration, but more accurate quantification was obtained by using isotopically labelled standards (commercially available for most of the pesticides studied). The method detection limits ranged from 0.02 mg/kg for chlormequat and mepiquat to 2 mg/kg for maleic hydrazide and were 0.05–0.2 mg/kg for most other pesticide/matrix combinations. This was sufficiently low to test compliance with EU maximum residue limits for many relevant pesticide/commodity combinations. The method substantially reduces the liquid chromatography–MS/MS capacity demand which for many laboratories is prohibitive for inclusion of these pesticides in their monitoring and surveillance programmes. Figure
?  相似文献   

15.
Quantitation of cytochrome c (Cyt c) in cell lysates through surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) using gold nanoparticles (Au NPs) as the matrix and GR-10 peptide as an internal standard has been demonstrated. To shorten digestion time, temperature sensitive microgels containing trypsin (TR) and Au NPs have been employed. As-prepared functional microgels (TR/Au NPs/MGs) allow digestion of Cyt c within 15 s under microwave irradiation. The internal standard SALDI-MS approach provides linearity (R2 = 0.98) of MS signal ratio (I 1168.6/I 1067.6) of the tryptic digested peptide (m/z 1168.6) to GR-10 peptide (m/z 1067.6) against the concentration of Cyt c ranging from 25 to 200 nM, with a limit of detection (at a signal-to-noise ratio of 3) of 10 nM. This approach has been validated by the analysis of the lysates of HeLa cells, with an average concentration of 13.7?±?3.5 μM for cytoplasmic Cyt c. Increased concentrations of Cyt c in the HeLa cells treated with etoposide (a commercial drug) or carbon dots (potential drug) have been revealed through this simple, sensitive, and rapid SALDI-MS approach, supporting the drugs induced Cyt c-mediated apoptosis of the cells. This study has shown that this internal standard SALDI-MS approach holds great potential for cell study. Graphical Abstract
?  相似文献   

16.
Poly(2-vinylpyridine)s (P2VPs) are important polymers with extensive applications in modern day material science. P2VP is an exceptional case for liquid chromatography because of certain polar interactions with most of the stationary phases. In the present study, we established the critical adsorption point (CAP) of P2VP for the first time. The effectiveness of the method is demonstrated by analyses of blends and block copolymers of P2VP and PMMA. The CAP of PMMA is established for determination of molar mass of P2VP component of above mentioned blends and block copolymers. The methods successfully demonstrate the separation of both types of homopolymers from the rest of the samples in conjunction with the determination of molar mass distribution of noncritical block or component. Graphical Abstract
?  相似文献   

17.
We report on the capillary electrophoretic behavior of citrate-capped gold and silver nanoparticles in aqueous medium when applying a ligand-exchange surface reaction with thiols. Gold nanoparticles (AuNPs) and silver nanoparticles (AgNPs) of similar size (39?±?6 and 41?±?7 nm, respectively) and shape were synthesized, covered with a citrate shell, and characterized by microscopic and spectroscopic techniques. The analysis of these NPs by CE was accomplished by using a buffer solution (pH 9.7; 40 mM SDS, 10 mM CAPS; 0.1 % methanol) containing the anions of thioctic acid or thiomalic acid. These are capable of differently interacting with the surface of the AuNPs and AgNPs and thus introducing additional negative charges. This results in different migration times due to the formation of differently charged nanoparticles. Figure
Capillary electrophoretic behavior of citrate-capped gold and silver nanoparticles (NPs) in aqueous medium when applying a ligand-exchange surface reaction with thiols (thioctic and thiomalic acids), which introduces additional negative charges, has been studied  相似文献   

18.
A novel quartz crystal microbalance (QCM) sensor has been developed for highly selective and sensitive detection of Pb2+ by exploiting the catalytic effect of Pb2+ ions on the leaching of gold nanoparticles from the surface of a QCM sensor. The use of self-assembled gold nanoparticles (AuNPs) strongly enlarges the size of the interface and thus amplifies the analytical response resulting from the loss of mass. This results in a very low detection limit for Pb2+ (30 nM). The high selectivity is demonstrated by studying the effect of potentially interfering ions both in the absence and presence of Pb2+ ions. This simple and well reproducible sensor was applied to the determination of lead in the spiked drinking water. This work provides a novel strategy for fabricating QCM sensors towards Pb2+ in real samples. Figure
?  相似文献   

19.
Carbon/1-octadecanethiol-carboxylated multiwalled carbon nanotubes (cMWCNT) composite was used to construct a DNA sensor for detection of human bacterial meningitis caused by Neisseria meningitidis. The carbon composite electrode was used to covalently immobilize 5′-amine-labeled 19-mer single-stranded DNA (ssDNA) probe, which was hybridized with 1.35?×?102–3.44?×?104 pM (0.5–128 ng/5 μl) of single-stranded genomic DNA (ssG-DNA) of N. meningitidis for 10 min at room temperature (RT). The surface topography of the DNA sensor was characterized by using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) while electrochemically characterized by electrochemical impedance. The immobilization of ssDNA probe and hybridization with ssG-DNA were detected electrochemically by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) at RT in 30 min with a response time of 1 min. The DNA sensor showed high pathogenic specificity and can distinguish among complement, noncomplement, one base mismatch, and triple base mismatch oligomer targets. The limit of detection (LOD) and sensitivity of the sensor were approximately 68 pM and 38.095 (μA/cm2)/nM of ssG-DNA, respectively, using DPV. The improved sensitivity and LOD of the sensor can be attributed to the higher efficiency of probe immobilization due to high surface area-to-volume ratio and good electrical activity of cMWCNT. Figure
?  相似文献   

20.
Amino acids represent a fraction of organic matter in marine and freshwater ecosystems, and a source of carbon, nitrogen and energy. l-Amino acids are the most common enantiomers in nature because these chiral forms are used during the biosynthesis of proteins and peptide. To the contrary, the occurrence of d-amino acids is usually linked to the presence of bacteria. We investigated the distribution of l- and d-amino acids in the lacustrine environment of Terra Nova Bay, Antarctica, in order to define their natural composition in this area and to individuate a possible relationship with primary production. A simultaneous chromatographic separation of 40 l- and d-amino acids was performed using a chiral stationary phase based on teicoplainin aglycone (chirobiotic tag). The chromatographic separation was coupled to two different mass spectrometers—an LTQ-Orbitrap XL (Thermo Fisher Scientific) and an API 4000 (ABSciex)—in order to investigate their quantitative performance. High-performance liquid chromatography coupled with mass spectrometry methods were evaluated through the estimation of their linear ranges, repeatability, accuracy and detection and quantification limits. The high-resolution mass spectrometer LTQ-Orbitrap XL presented detection limits between 0.4 and 7 μg?l ?1, while the triple quadrupole mass spectrometer API 4000 achieved the best detection limits reported in the literature for the quantification of amino acids (between 4 and 200 ng?l ?1). The most sensitive method, HPLC-API 4000, was applied to lake water samples. Figure
?  相似文献   