首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 968 毫秒
1.
A method applying pressure-assisted capillary electrophoresis combined with short-end injection has been developed for the rapid screening of the pKa values of pharmaceuticals. The electrophoretic separation is performed on a short capillary length with short-end injection under an applied pressure, and the effective mobility is measured in a series of 10 different buffers with constant ionic strength (I = 0.05). The application of pressure not only reduces migration times, particularly in lower pH buffers, but also improves the repeatability of effective mobility measurements. The influence of pressure on the effective mobility was investigated at various pH values. It was observed for the first time that an increase in pressure resulted in a slight decrease in the effective mobility when the pH was above the pKa for acidic analytes, whereas an increased effective mobility with increasing pressures was observed when the pH was below the pKa. However, the observed effective mobility shift by the applied pressure did not significantly affect the determined pKa values. The determined pKa values were in good agreement with published data. Furthermore, a stacking condition was applied to increase the sensitivity, and a concentration down to 2 microM could readily be detected with UV detection using a 50 microm I.D. capillary. This technique is particularly suitable for measurement of pKa values for compounds with poor aqueous solubility. The method also omits the commonly used preconditioning steps with sodium hydroxide and water. The exclusion of excessive preconditioning steps and the use of pressure reduces the total cycling analysis time, and makes it possible to determine the pKa in less than 40 min per compound without loss of accuracy.  相似文献   

2.
New strategies for rapid, sensitive and high-throughput analysis of low abundance metabolites in biological samples are required for future metabolomic research. In this report, a direct method for sub-micromolar analyses of phosphoamino acids was developed using on-line sample preconcentration with 9-fluorenylmethyloxycarbonyl chloride (FMOC) derivatization by capillary electrophoresis (CE) and UV detection. Analyte focusing by dynamic pH junction and FMOC labeling efficiency were influenced by several experimental factors including buffer pH, ionic strength, sample injection length and FMOC concentration. About a 200-fold enhancement in concentration sensitivity was achieved under optimal conditions relative to conventional off-line derivatization, as reflected by a detection limit (S/N approximately 3) of 0.1 microM. In-capillary sample preconcentration with chemical labeling by CE offers a unique single-step analytical platform for high-throughput screening of low abundance metabolites without intrinsic chromophores.  相似文献   

3.
On-line sample preconcentration by a dynamic pH junction in conjunction with multiplexed capillary electrophoresis (CE) and UV detection represents a sensitive and high-throughput format for future metabolomic research, such as purine analysis. The optimization of purine focusing can be rapidly assessed by systematically altering the sample matrix properties, such as the buffer co-ion, pH and ionic strength using a 96-capillary array format. This method permits focusing of large sample injection volumes, resulting in over a 50-fold improvement in the concentration sensitivity. The limit of detection (S/N = 3) for purine metabolites was less than 8.0 x 10(-8) M under optimum conditions when using UV absorbance. Dynamic pH junction multiplexed CE demonstrated excellent linearity over a hundred-fold concentration range, as well as low inter-capillary precision in terms of normalized migration times and peak areas. The potential for clinically relevant high-throughput analyses of micromolar amounts of purine metabolites in urine was also demonstrated.  相似文献   

4.
The present work describes the development and optimization of a capillary (zone) electrophoresis/mass spectrometric (CE/MS) analysis method for polar hydrophilic aromatic sulfonates (ASs). The compounds were detected by negative ion electrospray ionization (NIESI) and selected ion monitoring (SIM). In comparison with CE/UV, for CE/MS a lower-concentration volatile ammonium acetate buffer (5 mM) without organic modifier and a higher separation voltage were better suited for separation. Sensitivity of CE/MS was slightly better than for CF/UV, with the limit of detection (LOD) ranging between 0.1 and 0.4 mg l(-1). For verification of the CE/MS results, ASs were also analysed by ion-pair liquid chromatography/diode array UV detection coupled in series with electrospray mass spectrometry (IPC/DAD/ESI-MS). Real water samples of different waste water treatment plants (WWTPs) in Catalonia (NE Spain) were extracted by solid-phase extraction (SPE) with LiChrolut EN and analysed with CE/MS and LC/MS. ASs were found in influent and effluent water samples of the WWTPs in the microg l(-1) concentration range. LC/MS offered a higher separation efficiency and sensitivity than CE/MS. Therefore with LC/MS more compounds could be identified in the WWTPs. The persistency of the ASs was distinct: some compounds were well degraded during the water treatment process, while others were quite persistent.  相似文献   

5.
Capillary electrophoresis (CE) was used as a method to determine the acidity constants of eight aromatase inhibitors. This method was validated by comparison of results obtained with a traditional method, UV spectroscopy, and additionally with computational calculations. We confirmed here, with our series of compounds, that capillary electrophoresis is an attractive method for pKa measurements which is based on migration time or mobilities of the ionic species over a range of pH values. The precision of pKa measurements of N-imidazole derivatives is useful to observe pKa shifts induced by chemical modifications introduced on adjacent aromatic rings such as heterocycle (benzoxa- or benzothiazolinone) or substituted benzyle. The knowledge of these pKa values is a great interest to predict migration of solutes and qualitative interactions with ionized cyclodextrines as chiral selectors in further enantioseparative CE studies.  相似文献   

6.
Capillary electrophoresis (CE) has emerged as an important tool for evaluating the ionisation characteristics of compounds and their corresponding pKa values. A particular strength of CE in this context is that its relative selectivity allows one to measure the extent of ionisation of materials that are impure. In this study, using CE, we have measured the pKa values of a series of anti-inflammatory aminoindanones, which underwent degradation to indenone during the course of the determination. We subsequently monitored the elimination reactions measuring remaining indanone over the pH range 2.6-10 at constant ionic strength and temperature. The decomposition of the tertiary amino derivatives was especially fast with first-order half-lives of less than 10 min observed at pH 7.4. The resulting sigmoidal pH rate profiles can be accounted for by assuming unimolecular elimination of the protonated (slow) and neutral (fast) forms of the amines. This study provides further support for the use of CE in evaluating amino ionisation especially in cases where degradation might be expected.  相似文献   

7.
Throughout the separation of chiral basic drugs by capillary electrophoresis (CE) with neutral hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral selector, the sensitivity of detection can be improved by using tandem mass spectrometric (MS-MS) detection with a partial filling technique rather than with UV spectrometric detection. Prior to sample injection. the capillary was partly filled with HP-beta-CD dissolved in volatile ammonium formate buffer (pH 4, ionic strength 50 mM). The effects of modifying the HP-beta-CD concentration in the selector zone and the length of the separation zone on the enantioresolution and the signal-to-noise ratio of the pseudo-molecular MH+ ion were investigated. For a given selector zone length, as the concentration of the neutral cyclodextrin increases, the resolution between enantiomers becomes higher (the opposite of the behavior of the signal-to-noise ratio) and then reaches an optimum value. The decrease of the selector zone length lowered the resolution between the enantiomers but increased peak efficiencies and signal-to-noise ratio values. Accordingly, partial capillary filling at 80% (v/v) and 10 mM concentration of HP-beta-CD was selected as a suitable compromise between resolution and sensitivity of MS detection. Limits of detection for each adrenoreceptor antagonist enantiomer were 5 ng/ml (0.02 microM) in CE-MS-MS instead of 150 ng/ml (0.60 microM) in CE-UV, which enhances sensitivity by a factor of 30.  相似文献   

8.
Chang SY  Tseng WL  Mallipattu S  Chang HT 《Talanta》2005,66(2):411-421
The review focuses on the analysis of small phosphorus-containing compounds by capillary electrophoresis (CE) with different detection modes including UV absorption, laser-induced fluorescence, conductometry, amperometry, atomic spectrometry, and mass spectrometry. Determinations of phosphates, organophosphate, and chemical warfare agents in environmental samples such as water, soil and grains are emphasized. To achieve better sensitivity, high-resolving power, and reproducibility, the optimum separation conditions for various analytes (samples) are different. We compare the merits and demerits of the different detection modes for the detection of the analytes. Although the present methods are successful in many cases, there is still a need to develop high-throughput CE techniques for screening numerous environmental samples and sample stacking techniques in CE for the analysis of trace analytes.  相似文献   

9.
Electrospray ionization performs best with volatile buffers. However, generally the best separation performance for capillary electrophoresis (CE) is achieved with non‐volatile buffers. Hyphenation of CE with mass spectrometry (MS) utilizing atmospheric pressure photoionization (APPI) enables use of a wider range of separation buffers without compromising detection sensitivity. As APPI is considered to be mass flow sensitive, the use of a larger inner diameter separation capillary (75 µm) allows larger volumes to be injected, without decreased separation performance, thus providing improved sensitivity (approx. a factor of 10), compared to the use of a 25 µm capillary. However, nebulizing gas flow and position of capillary tip in the sprayer have to be carefully optimized to prevent excessive band broadening. Further improvement in sensitivity (approx. a factor of 2) was obtained by decreasing the distance between the sprayer and ionization region, indicating that a specially designed CE/APPI‐MS interface for low flow rates will be favourable. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
When optimizing a capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) system, consideration has to be given not only to the separation but also to the electrospray stability. Methods developed for CE/UV analysis of drugs and peptides were considered and modified to be suitable for a CE/MS system with a robust sheathless interface. Different concentrations of the organic modifiers acetonitrile, methanol and 2-propanol were used in the separation buffer. The type and concentrations of these modifiers were also compared with reference to electrospray stability, sensitivity and time of analysis. In addition, different ionic strengths in the buffers were evaluated with reference to electrospray stability. The repeatability was used for the estimation of electrospray stability. The degree to which these parameters influenced the separation and the ESI stability was studied using a nine-peptide standard mixture and the antibiotic drugs bacampicillin and ampicillin as test substances. The analysis time and resolution were used as measures of the efficiency of the separation. A time-of-flight MS analyzer was used since it has the potential advantages of becoming a better fit for integration of CE with MS owing to the speed and sensitivity of this mass analyzer. The detection limit, i.e. 1 microM, for bacampicillin was comparable to what could be achieved with CE/MS on a quadrupole instrument using selected ion monitoring and sheath flow ESI.  相似文献   

11.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

12.
LC/MS is being used for the routine analysis of small molecules in both the discovery and development stages within the pharmaceutical industry. In drug discovery, LC/MS is relied upon to confirm the identity and assess the purity of chemical entities. To ensure the quality of LC/MS analysis, it is important that the LC/MS system is operating within defined performance criteria. Performance monitoring of the system with a standard compound mix offers many advantages over other alternatives, since it monitors the LC/MS system as an integrated unit under the same working conditions as those used for the analysis of samples. It is also a convenient approach, because the test mix can be injected as part of the automated sequence. Use of a test mix for similar purposes has been described previously (Tang, L.; Fitch, W. L.; Alexander, M. S.; Dolan, J. W. Anal. Chem. 2000, 72, 5211-5218). To monitor the performance of ArQule's LC/MS operation (with UV and ELS detection) in greater detail, a set of eight compounds was selected from a collection of 137 commercially available "druglike" compounds. The compounds are generally stable and compliant with the rule-of-five criteria. This enhanced mix has a balanced selection of pKa values and covers the typical range of hydrophobicity and molecular masses of pharmaceutical compounds. Moreover, the selected compounds can generally be ionized using ESI and APCI modes with positive and negative polarity. The test mix can be used under formic acid or ammonium hydroxide conditions and with methanol or acetonitrile as an organic modifier. Performance monitoring with the enhanced mix is demonstrated with respect to ionization and mass measurement, as well as changes in gradient profile, flow rate, buffer pH, and ionic strength.  相似文献   

13.
Fluoroquinolones are a group of synthetic antibiotics with a broad activity spectrum against mycoplasma, Gram‐positive, and Gram‐negative bacteria. Due to the extensive use of fluoroquinolones in farming and veterinary science, there is a constant need in the analytical methods able to efficiently monitor their residues in food products of animal origin, regulated by Commission Regulation (European Union) no. 37/2010. Herein, field‐enhanced sample injection for sample stacking prior the CZE separation was developed inside a bubble cell capillary for highly sensitive detection of five typical fluoroquinolones in bovine milk. Ethylenediamine was proposed as the main component of BGE for the antibiotics separation. The effect of BGE composition, injection parameters, and water plug length on the field‐enhanced sample injection‐based CE with UV detection was investigated. Under the optimized conditions, described field‐enhanced sample injection‐based CE‐UV analysis of fluoroquinolones provides LODs varying from 0.4 to 1.3 ng/mL. These LOD values are much lower (from 460 to 1500 times) than those obtained by a conventional CE in a standard capillary without bubble cell. The developed method was finally applied for the analysis of fluoroquinolones in low‐fat milk from a Swiss supermarket. Sample recovery values from 93.6 to 106.0% for different fluoroquinolones, and LODs from 0.7 to 2.5 μg/kg, were achieved. Moreover, the proposed ethylenediamine‐based BGE as volatile and compatible with MS system, enabled the coupling of the field‐enhanced sample injection‐based CE with a recently introduced electrostatic spray ionization MS via an iontophoretic fraction collection interface for qualitative fluoroquinolones identification.  相似文献   

14.
Jia Z  Ramstad T  Zhong M 《Electrophoresis》2001,22(6):1112-1118
A fast screening method for the determination of the dissociation constants (pKa) of acidic, basic, and multivalent compounds was developed by using pressure-assisted capillary electrophoresis (PACE). External air pressure was applied to shorten the analysis time. The separation efficiency decreases as air pressure increases. However, it was found that air pressure does not affect the measurement of electrophoretic mobility and pKa significantly when it is less than 2 psi. The method was evaluated in terms of accuracy, precision, and ruggedness by using a set of 48 compounds with literature pKa values ranging from 2 to 10. The difference between the measured pKa values and literature values is less than 0.2 units. The throughput is approximately 20 compounds per day with a 12-point measurement ranging from pH 2.5 to 11. It was demonstrated that this method is applicable for pKa screening of pharmaceuticals with diverse chemical structures.  相似文献   

15.
Our understanding of metal ion adsorption to clay minerals has progressed significantly over the past several decades, and theories have been promulgated to describe and predict the impacts of pH, ionic strength, and background solution composition on the extent of adsorption. Studies evaluating the effects of ionic strength on adsorption typically employ a broad range of background electrolyte concentrations. Measurement of pH in these systems can be inaccurate when pH values are measured with liquid junction pH probes calibrated with standard buffers due to changes in the liquid junction potential between standard, low ionic strength (0.05 M) buffers and high ionic strength solutions (>0.1 M). The objective of this research is to determine the extent of the error in pH values measured at high ionic strength, and to develop an approach for accurately measuring pH over a range of ionic strengths using a combined pH electrode. To achieve this objective, the adsorption of cobalt (10(-5) M) onto gibbsite (10 g/L) from various electrolyte solutions (0.01-1 M) was studied. The pH measurements were determined from calibrations with standard buffers and ionic strength corrected buffer calibrations. The results show a significant effect of the aqueous solution background electrolyte anion and ionic strength on pH measurement. The 0.5 and 1 M ionic strength metal ion adsorption edges shifted to lower pH with increasing ionic strength when pH was calibrated with standard buffers whereas no shift in the adsorption edges was observed when calibrated with ionic strength corrected buffers. Therefore, to obtain an accurate pH measurement, pH calibration should contain the same electrolyte and ionic strength as the samples.  相似文献   

16.
Sixteen synthetic chemical drugs, often found in adulterated Chinese medicines, were studied by capillary electrophoresis/UV absorbance (CE/UV) and capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS). Only nine peaks were detected with CZE/UV, but on-line CZE/MS provided clear identification for most compounds. For a real sample of a Chinese medicinal preparation, a few adulterants were identified by their migration times and protonated molecular ions. For coeluting compounds, more reliable identification was achieved by MS/MS in selected reaction monitoring mode. Micellar electrokinetic chromatography (MEKC) using sodium dodecyl sulfate (SDS) provided better separation than capillary zone electrophoresis (CZE), and, under optimal conditions, fourteen peaks were detected using UV detection. In ESI, the interference of SDS was less severe in positive ion mode than in negative ion mode. Up to 20 mM SDS could be used in direct coupling of MEKC with ESI-MS if the mass spectrometer was operated in positive ion mode. Because of better resolution in MEKC, adulterants can be identified without the use of MS/MS.  相似文献   

17.
With the combination of high separation ability of capillary electrophoresis (CE) and strong identification ability of mass spectrometry (MS), CE/MS is becoming a powerful tool for polar and ionic analytes analysis. Different interfaces have been developed to enhance the sensitivity and reliability since the first introduction of CE/MS in 1987. A sheathless porous interface based on a new ions transferring electric connection technique was reported to be with high sensitivity and reliability. In this work, a series of optical and electrochemical experiments were designed to study the electric connection process. The results indicated that closing CE electrical circuit and applying MS spray voltage were achieved by the small ions transferring through the interface porous wall. The new electric connection method significantly enhanced the sensitivity, resolution and stability of the CE/MS analysis. The interface was applied in CE/MS detection of morphine and 6‐monoacetylmorphine in urine sample and showed an equal sensitivity to LC/MS. With the significant improvement of sensitivity and stability, the CE/MS with the new interface showed strong potential for the determination of low abundance analytes. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
19.
A CE method utilizing triple quadrupole electrospray (ES) MS (MS/MS) detection was developed and validated for the simultaneous measurement of nucleoside 5'-triphosphate and 5'-monophosphate anabolites of the anti-HIV (human immunodeficiency virus) didanosine (ddAMP, ddATP) and stavudine (d4TMP, d4TTP), among a pool of 14 endogenous 5'-mono-, di-, and triphosphate nucleosides. These compounds were spiked and extracted from peripheral blood mononuclear cells (PBMCs) which are the sites of HIV replication and drug action. An acetic acid/ammonia buffer (pH 10, ionic strength of 40 mM) was selected as running electrolyte, and the separation was performed by the simultaneous application of a CE voltage of +30 kV and an overimposed pressure of 28 mbar (0.4 psi). The application of pressure assistance was needed to provide stable ES conditions for successful coupling. The coupling was carried out with a modified sheath-flow interface, with one uninterrupted capillary (80 cmx 50 microm id; 192 microm od) in a dimension that fits into the ESI needle to get a stable ion spray. Some CE-MS parameters such as overimposed pressure, sheath-liquid composition, sheath-liquid and sheath-gas flow rates, ES voltage, and the CE capillary position were optimized in order to obtain an optimal sensitivity. The use of perfluorinated alcohols and acids in the coaxial sheath-liquid make-up (2,2,2-trifluoroethanol + 0.2 mM tridecafluoroheptanoic acid) appeared to provide the best MS sensitivity and improve the stability of spray. The linearity of the CE-MS and CE-MS/MS methods was checked under these conditions. Validation parameters such as accuracy, intraday and interday precision, and LOQs were determined in CE-MS/MS mode. Finally, the quantitation of d4T-TP and ddA-TP was validated in this CE-MS/MS system.  相似文献   

20.
Capillary electrophoresis (CE) was used for the determination of ionisation constants (pKa) of a variety of organic bases in aqueous acetonitrile solutions over the range 0-60% (v/v) acetonitrile. These bases are used as test compounds in HPLC column evaluation, thus knowledge of their pKa in hydro-organic solutions is useful. The base pKa decreased with acetonitrile concentration and significant shifts from the aqueous pKa (up to -0.8) were found using 60% acetonitrile. The CE application was confirmed to be very suitable for fast and accurate pKa measurement in aqueous organic solutions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号