首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
In this study, a practicable and effective analytical method based on solid-phase-extraction and reversed-phase liquid chromatography with fluorescence detection (SPE-LC-FLD) was developed and partially validated for routine analysis of eight FQs in wastewater at the trace level. Different SPE materials, pH conditions and eluents were modified to find an economic and effective SPE conditions. In our work, it is the first time that well-known commercially available SPE sorbent are compared to ‘generic’ cheap SPE sorbent. Aqueous samples (pH 2–3) were extracted using Anpel? MEP cartridges where they were subsequently eluted by 6?mL of 2% formic acid in MeOH. The aqueous extracts were analysed by gradient elution LC-FLD, whose initial mobile phase was composed of ACN and 10?mmol?L?1 tetrabutyl ammonium bromide (4/96, v/v, pH 3). The LODs and LOQs of the wastewater were as low as 0.32–2.12?ng?L?1 and 1.07–7.07?ng?L?1, respectively. The precisions of the overall method (RSD, n?=?3) using wastewater were below 10%. The method was used to quantify FQs in influents and effluents of several typical sewage treatment plants (STPs) in Shanghai. The extraction recoveries of 100?mL influent, 500?mL effluent and 500?mL of river water samples were between 88.6 and 102.6%, 79.2 and 109.2%, 80.0 and 105.5% and 87.4 and 99.4%, respectively. FQs of interest except sarafloxacin were identified in the influents, effluents and river waters with concentrations varying from 0.012–1.163?µg?L?1, 0.003–0.291?µg?L?1, and 0.002–0.040?µg?L?1, respectively. The method can serve as a tool to obtain detailed information on occurrence, behaviour and fate of FQs in the aquatic environment. Occurrence of FQs detected in summer is higher than in spring at STPs, and those detected in the suburban area are less than those in the urban area. Complete removal of FQs is not achieved from the STPs, indicating domestic wastewater and STP discharge is the source of FQs in the surface water.  相似文献   

2.
This paper describes our research on the synthesis of the sorbent with chemically bonded ketoimine groups, and, furthermore, using this sorbent in the SPE technique to extract and preconcentrate trace amounts of metal ions in water samples. Surface characteristics of the sorbent were determined by elemental analysis, NMR spectra for the solid phases (29Si CP MAS NMR), and analysis of pore size distribution of the sorbent and nitrogen adsorption-desorption. The newly proposed sorbent with ketoimine groups was applied for the extraction and preconcentration of trace amounts of Cu (II), Cr (III) and Zn (II) ions from the water from a lake, post-industrial water and purified water unburdened back to the lake. The determination of the transition-metal ions was performed on an emission spectroscope with inductively coupled plasma ICP-OES. For the batch method, the optimum pH range for Cu (II) and Cr (III) extraction was equal to 5, and Zn(II)–to 8. All the metal ions can be desorbed from SPE columns with 10?mL of 0.5?mol?HNO3. The detection limits of the method were found to be 0.7?µg?L?1 for Cu (II), 0.08?µg?L?1 for Cr (III), and 0.2?µg?L?1 for Zn (II), respectively.  相似文献   

3.
A method for analysis of short-chain chlorinated paraffins (SCCPs) in water based on solid-phase extraction (SPE) was established using electron capture negative chemical ionization mass spectrometry (GC-ENCI-MS). The SPE parameters, including the sorbent, eluent and elution volume were optimized. The Agilent Bond Elut-C18 was precleaned with 3 mL of hexane and 3 mL of methanol, and subsequently conditioned with 3 mL H2O prior to use. After the water samples were enriched by the cartridge, the sample was washed with 3 mL of 10% (V/V) methanol and eluted with 3 mL of hexane-dichloromethane (1:1, V/V) solution. The results indicated that the limits of detection (LOD) for SCCPs were 18 ng L?1, while the corresponding limits of quantitation (LOQ) were 60 ng L?1. The spiked recovery range was 90%–135%, with a relative standard deviation of less than 10%. Finally, 20 surficial water samples around Beijing were collected and SCCPs contents were analyzed using the proposed method. The SCCPs concentrations ranged from less than LOD to 682 ng L?1 with a mean concentration of 216 ng L?1.  相似文献   

4.
A simple and sensitive method is presented for solid phase extraction (SPE) and preconcentration of trace quantities of beryllium using octadecyl silica gel modifed with aurin tricarboxylic acid (aluminon). Beryllium is then determined by flame atomic absorption spectroscopy. Parameters affecting SPE such as pH, sample solution and eluent flow rate, type, concentration and volume of eluent, interfering ions and breakthrough volume, were investigated. Under optimal conditions, the beryllium ions were retained on the sorbent at pH 6–6.7, while 3.0 mL of 0.05 mol L?1 HNO3 is sufficient to elute the ions. The limit of detection (LOD) based on 3σ was 0.8 µg L?1 for 250 mL sample solution and 5 mL 0.05 mol L?1 HNO3 as eluent. The LOD can reach 0.1 µg L?1 for 1 L sample solution and 3 mL of 0.05 mol L?1 HNO3. The accuracy and precision (RSD %) of the method is >90% and <10%, respectively. The method was applied to the determination of beryllium in aqueous samples.  相似文献   

5.
In this work, a sensitive flow injection chemiluminescence (FI-CL) method for the determination of nematicide Fenamiphos in a rapid and simple way is proposed. Fenamiphos is first photodegraded in basic medium. These photofragments react with Ce(IV) providing the chemiluminescence signal. To the authors’ knowledge, no chemiluminescence method has been described in the literature for the determination of the nematicide Fenamiphos. All physical and chemical parameters in the flow injection chemiluminescence system were optimized in order to obtain the best sensitivity, selectivity and sample throughput. Before the injection of the sample in the FI-CL system, a preconcentration step with solid phase extraction C18 cartridges was performed. By applying solid phase extraction (SPE) to 250?mL of standard (final volume 10?mL), the linear dynamic range was between 3.4 and 60?µg?L?1, and the detection limit was 1?µg?L?1. When SPE was applied to 500?mL of standard (final volume 10?mL), the detection limit was 0.5?µg?L?1. These detection limits are below the emission limit value established by the Spanish Regulations of the Hydraulic Public Domain for pesticides (50?µg?L?1) and of the same order as the limit established for total pesticides (0.5?µg?L?1) at European Directive on the quality of water for human consumption. The sample throughput was 126 hour?1. Intraday and interday coefficients of variation were below 10% in all cases. No interference was registered in presence of usual concentrations of anions, cations and other organophosphorus pesticides. The method was successfully applied to the analysis of environmental water samples, obtaining recoveries between 96 and 107.5%.  相似文献   

6.
A method for analysis of 20 commonly used pesticides in surface water based on solid-phase extraction and gas chromatography-mass spectrometry was proposed. During method development the key parameters that can affect SPE extraction and determination such as selection of efficient SPE sorbent, pH of water sample, type and volume of elution solvent, breakthrough volume and matrix effects were investigated. The method was validated using spring water spiked with appropriate concentration of pesticides. The obtained correlation coefficients were in range 0.9972–1.000, limits of detection (LOD) were 0.001–0.5?µg?L?1 and the limits of quantification (LOQ) were 0.005–1?µg?L?1 depending on a pesticide. Much higher LOD (20?µg?L?1) and LOQ (50?µg?L?1) values were obtained for bentazone. The influence of matrix was assessed using real water samples spiked with appropriate concentration of pesticide standards solution. Both signal enhancement and suppression were observed, depending on a pesticide, therefore standard addition method was used for pesticides determination. The developed method was applied on real water samples taken in close vicinity of agricultural fields. Many of the targeted pesticides were found in the samples and the results are presented in this article.  相似文献   

7.
The development of a preconcentration method for the measurement of trace levels of mercury in digested sediments is described. Solid phase extraction (SPE) was used for the preconcentration of mercury coupled on-line by means of a flow injection (FI) system followed by cold vapour atomic absorption spectrometry (CVAAS) detection. The SPE was carried out through a column packed with a sorbent material containing triisobutylphosphine sulfide (CYANEX 471X®) as mercury extractant and prepared by the sol-gel process. The effects of FI variables (argon, eluent, and reductant flow rates, loading and elution times) as well as the eluent concentration on the analytical performance of the method were evaluated. The proposed method was validated under the optimum conditions. The calibration graph was linear from 0.05?µg?L?1 to 3.0 µg?L?1 of Hg. The detection limit (DL), based on three times the standard deviation of the blank measurement criterion, was 24?ng?L?1. The repeatability was 1.5% and 1.8% RSD (n?=?10) at concentrations of 0.5 and 1 µg?L?1 of Hg, respectively. Method enrichment factors of 16 with a productivity of 30 samples h?1 or 32 with a productivity of 17 samples h?1 were achieved under selected conditions. Certified reference materials, inductively coupled plasma mass spectroscopy (ICP-MS) and cold vapour atomic fluorescence spectrometry (CVAFS), were used to evaluate the accuracy of the proposed method.  相似文献   

8.
A new sorbent – salen impregnated silica gel – was prepared and characterised for application as a minicolumn packing for flow-injection on-line preconcentration of cadmium(II). The system was coupled with flame atomic absorption spectrometer (FI-FAAS). The optimal pH for Cd(II) sorption was in the range of 7.4–8.8 and nitric acid (1%, v/v) was efficient as eluent. Sorption was most effective within the sample flow rate up to 7?mL?min?1. Sorption capacity of the sorbent found in a batch procedure was 26.3?µmol?g?1 (2.95?mg?g?1). Enrichment factor (EF) and limit of detection (LOD) obtained for 120-second loading time were 113 and 0.26?µg?L?1, respectively. The sorbent stability in the working conditions was proved for at least 100 preconcentration cycles. The evaluated method was applied to Cd(II) determination in various water samples.  相似文献   

9.
The development of a solid-phase extraction (SPE) procedure for the pre-concentration of trace amounts of Pb2+ ion on 2-furan-2-yl-1-furan-2-ylmethyl-1H-benzoimidazole loaded on activated carbon modified with silver nanoparticles (L-AC-Ag-NP) was presented. The metal ion retained on the sorbent was quantitatively determined via complexation with the ligand. The complexed metal ion was efficiently eluted using 10 mL of 4 mol L?1 sulphuric acid in 10 w/v% acetone. The influences of the analytical parameters, including pH, amounts of the ligand and the solid phase, eluent conditions and sample volume, on the recoveries of the metal ion were optimised. Using the optimised parameters, the linear response of the SPE method for Pb2+ ion were in the ranges of 0.2–160 µg L?1, and the detection limit for Pb2+ ion was 0.034 µg L?1. The proposed method exhibits a pre-concentration factor (PF) of 80 and an enhancement factor of 30 for Pb2+ ion. The presented results demonstrate the successful application of the proposed method for the determination of Pb2+ ion in some real samples with high recoveries (>93%) and reasonable relative standard deviation (RSD < 2%).  相似文献   

10.
The possibility of using ionic liquid based chitosan sorbent for the separation and preconcentration of fluoroquinolone antibiotics (marbofloxacin, enoxacin, ofloxacin, ciprofloxacin, and enrofloxacin) has been studied. For this reason, different ionic liquids were prepared and coated on the chitosan sorbent. The conditions of the preconcentration of fluoroquinolones on a microcolumn have been optimized and the extraction efficiencies of the prepared sorbents have been compared. The compounds were eluted with 5 mL of 20% NH3 (v/v, MeOH) solution and determined by HPLC with diode array and fluorescence detector. The limits of detection were found as 4.23 µ g L?1 for marbofloxacin, and 1.09 µg L?1 for enoxacin; 3.23 × 10?3 µg L?1 for ofloxacin; 8.39 × 10?3 µg L?1 for ciprofloxacin; and 19.50 × 10?3 µg L?1 for enrofloxacin. The developed method was applied for the analysis of fluoroquinolone in milk, egg, fish, bovine, and chicken samples and the recoveries were obtained in the range 70–100%.  相似文献   

11.
In the present study, the ?5-(4-dimethylaminobenzylidene)rhodanin-modified SBA-15? was applied as stable solid sorbent for the separation and preconcentration of trace amounts of cobalt ions in aqueous solution. SBA-15 was modified by ?5-(4-dimethylaminobenzylidene)rhodanin reagent. The sorption of Co2+ ions was done onto modified sorbent in the pH range of 6.8–7.9 and desorption occurred in 5.0 mL of 3.0 mol L?1 HNO3. The results exhibit a linear dynamic range from 0.01 to 6.0 mg L?1 for cobalt. Intra-day (repeatability) and inter-day (reproducibility) for 10 replicated determination of 0.06 mg L?1 of cobalt was ±1.82% and ?±1.97%?. Detection limit was 4.2 µg L?1 (3Sb, n = 5) and preconcentration factor was 80. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type and interference ions were studied for the preconcentration of Co2+. The proposed method was applied for the determination of cobalt in standard samples, water samples and agricultural products.  相似文献   

12.
In this work, bamboo charcoal (BC) was used as a sorbent for on-line solid phase extraction (SPE) coupling with flame atomic absorption spectrometry (AAS) for trace copper and zinc determination in environmental and biological samples. Under the optimum pH of 5.5 (for Zn) and 7.0 (for Cu), trace copper and zinc were effectively adsorbed on the microcolumn and the retained cations were efficiently eluted with HCl or HNO3 with an appropriate concentration and flow rate for on-line AAS determination. With a sample loading time of 60 s at a sample flow rate of 7.6 mL min?1, the enhancement factors of 39 (for Cu) and 30 (for Zn) and detection limits (3σ) of 0.60 µg L?1 (for Cu) and 0.36 µg L?1 (for Zn), respectively, were achieved. The sample throughput was 45 h?1. At the level of 20 µg L?1of Cu(II) and Zn(II), the precision (RSD, n?=?11) were found to be 0.26% and 1.6%, respectively. The proposed method has been successfully applied to the determination of copper and zinc in environmental and biological samples.  相似文献   

13.
The monitoring of the heavy metal pollution in wastewater is increasingly becoming a crucial global issue since they tend to accumulate in food chains and can cause many biological abnormalities. In this work, it was developed a novel lead ion-imprinted polymer (IIP) using sodium dodecyl sulphate (SDS) as a second template to be used as adsorbent in solid phase extraction (SPE) for determination of lead from wastewater samples by UV–vis spectrophotometry. The polymer called IIP–SDS was synthesised by a double-imprinting process with lead (template) and SDS (template). IIP–SDS was characterised by infrared spectroscopy Fourier transform infrared spectroscopy, thermogravimetric analysis and scanning electron microscopy. IIP–SDS showed good recovery for lead (around 82.0%), while the IIP (only lead as template) was 72.2% and non-IIP was 44.9%. Thus, the double-imprinting process for the preconcentration of Pb2+ proved to be a more adequate methodology than IIP with a single template. The optimised parameters of sample preparation were washing solvent (2.0 mL of tetrahydrofuran), type and volume of eluent (5 mL of 1 mol L?1 hydrochloric acid), sample amount (30 mL of water spiked with 10.0 µg mL?1), amount of IIP–SDS (400 mg) and sample pH (pH = 4.5). Linearity ranged from 10 to 125 µg L?1 with r > 0.992. The limit of detection and quantification were 6.3 and 10 µg L?1, respectively. The precision (relative standard deviation, %) and accuracy (relative error, %) were lower than 15%. Finally, IIP–SDS may be an alternative and effective adsorbent for SPE procedures in monitoring of wastewater samples.  相似文献   

14.
A gas chromatography–tandem mass spectrometry (GC–MS/MS) method has been developed for the determination of selected pharmaceutical residues (carbamazepine, salicylic acid, clofibric acid, ibuprofen, 2-hydroxy-ibuprofen, fenoprofen, naproxen, ketoprofen, diclofenac, and triclosan) in sewage influent and roughly primary-treated effluent. The method involved solid-phase extraction (SPE) with polymeric sorbents, and two SPE cartridges were compared for the extraction and elution of the targeted compounds in complex matrices. A successful chemical derivatization of carbamazepine and acidic compounds using N,O-bis(trimethylsilyl) trifluoroacetamide +10% trimethylchlorosilane is also described. The quantification limits of the analytical procedure ranged from 30 to 60?ng?L?1 for 500?mL of wastewater. The best recovery rates (72–102%) in spiked effluent samples were obtained with Phenomenex Strata-X? cartridges. Detection limits (S/N?=?3) were estimated at between 1 and 18?ng?L?1. The reported GC–MS/MS method significantly reduces the strong matrix effects encountered with more expensive LC-MS/MS techniques. Application of the developed method showed that most selected analytes were detected at concentrations ranging from low µg?L?1 to trace level ng?L?1 in Montreal's wastewater treatment plant effluent and influent, as well as in the receiving waters at more than 8?km downstream of the effluent outfall. The rugged alternative analytical method is suitable for the simultaneous analysis of carbamazepine and pharmaceutical acidic residues in wastewater samples from influents and effluents that have undergone rough primary treatment.  相似文献   

15.
Liquid-liquid and solid-phase extraction procedures are proposed for famotidine isolation from aqueous samples. The isolation and spectrophotometric determination of famotidine is based on its complexation reaction with thymol blue. The composition of a complex between drug and reagent (1?:?1) was established. Dichloromethane and methanol were used as extraction solvents for LLE and SPE processes. Quantification of famotidine was done spectrophotometrically at 544?nm for dichloromethane or at 434?nm for methanolic extracts. The Beer law is obeyed in the famotidine concentration range 3?·?10?5?mol?L?1–2.0?·?10?4?mol?L?1 for LLE procedure and 2.0?·?10?6?mol?L?1–8.0?·?10?5?mol?L?1 for SPE.  相似文献   

16.
Detailed below is a simple reversed-phase liquid chromatography (RP-LC) method for the simultaneous separation of up to 21 acidic, basic, and neutral pharmaceuticals using Merck Chromolith Performance RP-C18e monolithic columns with direct ultraviolet (UV) absorption detection. By simultaneously applying a solvent elution gradient program with a mobile phase flow gradient, both a decrease in the overall analysis time and a general increase in peak efficiencies were observed. Mobile phase pH and buffer concentration were optimised using the overall resolution product under applied gradient conditions. Under optimised conditions peak area reproducibility (n?=?6) ranged between 0.4 and 9.3%, determined at the method LOQ level. For real sample analysis pharmaceutical residues were extracted using an optimised solid phase extraction (SPE) procedure, utilising Strata-X extraction cartridges, which overall provided the highest relative recovery data in comparison with four other commercially available SPE sorbents (17 out of 20 residues investigated had recoveries over 70%). Complete method precision, including all sample pre-treatment and LC analysis for six spiked river water samples at the 1 and 2?µg?L?1 level was between 10 and 29%. Using 1?L volumes of 1?µg?L?1 spiked estuarine water samples, the majority of detection limits were found to be in the 10–50?ng?L?1 range.  相似文献   

17.
Solid-phase extraction followed by dispersive liquid–liquid microextraction (SPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating benzaldehyde, a toxic oxidation product of the widely used preservative and co-solvent benzyl alcohol, in injectable formulation solutions. SPE of benzaldehyde from samples was carried out using C18 sorbent. After the elution of benzaldehyde from the sorbent by using acetonitrile, DLLME technique was performed on the obtained solution. Benzaldehyde was preconcentrated by using DLLME technique. Thus, 1.5 mL acetonitrile extract (disperser solvent) and 55.0 µL 1,2-dichloroethane (extraction solvent) were added to 5 mL ultra pure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limit (LOD) of benzaldehyde calculated as three times the signal-to-noise ratio (S/N) was 0.08 µg L?1. The relative standard deviation (RSD) for four replicates was 5.8 %. The calibration graph was linear within the concentration range of 0.5–500 µg L?1 for benzaldehyde. The proposed method has been successfully applied to the analysis of the benzaldehyde in injectable formulation solutions (diclofenac, vitamin B-complex and voltaren) and the relative recoveries were between 88 and 92 % and show that matrix has a negligible effect on the performance of the proposed method.  相似文献   

18.
A simple and robust analytical method for analysis of octyl- and nonylphenol as well as their short-chained ethoxylates in river water was proposed. Quantification of these analytes was performed by high-performance liquid chromatography with fluorescence detection after isolation using solid phase extraction with polytetrafluoroethylene sorbent. The method allowed one to obtain about 80–100% recovery for octylphenol and its ethoxylates and 70–80% for nonylphenol and its ethoxylates. Also, there was no need for additional sample cleaning before chromatographic analysis. The limit of detection was 0.01?µg?L?1 for octylphenol and its ethoxylates and 0.03?µg?L?1 for nonylphenol and its ethoxylates. The proposed method was used for quantitation of octyl- and nonylphenol together with their short-chained ethoxylates. Nonylphenol, nonylphenol mono- and diethoxylates were detected at concentrations ranging from 0.12 to 0.53?µg?L?1. Octylphenol, octylphenol mono- and diethoxylates were detected in four out of eleven samples at concentrations ranging from 0.03 to 0.17?µg?L?1. High concentrations of nonylphenol and its ethoxylates were found in the samples, despite the fact that their use in European countries was forbidden several years ago.  相似文献   

19.
《Analytical letters》2012,45(11):2285-2295
Abstract

Multi‐walled carbon nanotubes (MWNTs) were used as sorbent for flow injection (FI) on‐line microcolumn preconcentration coupled with flame atomic absorption spectrometry (FAAS) for determination of trace cadmium and copper in environmental and biological samples. Effective preconcentration of trace cadmium and copper was achieved in a pH range of 4.5–6.5 and 5.0–7.5, respectively. The retained cadmium and copper were efficiently eluted with 0.5 mol L?1 HCl for on‐line FAAS determination. The MWNTs packed microcolumn exhibited fairly fast kinetics for the adsorption of cadmium and copper, permitting the use of high sample flow rates up to at least 7.8 mL min?1 for the FI on‐line microcolumn preconcentration system without loss of the retention efficiency. With a preconcentration time of 60 sec at a sample loading flow rate of 4.3 mL min?1, the enhancement factor was 24 for cadmium and 25 for copper at a sample throughput of 45 h?1. The detection limits (3σ) were 0.30 and 0.11 µg L?1 for Cd and Cu, respectively. The precision (RSD) for 11 replicate measurements was 2.1% at the 10‐µg L?1 Cd level and 2.4% at the 10‐µg L?1 Cu level. The developed method was successfully applied to the determination of trace Cd and Cu in a variety of environmental and biological samples.  相似文献   

20.
A sensitive and simple method for determination of chromium species after separation and preconcentration by solid phase extraction (SPE) has been developed. For the determination of the total concentration of chromium in solution, Cr(VI) was efficiently reduced to Cr(III) by addition of hydroxylamine and Cr(III) was preconcentrated on a column of immobilised ferron on alumina. The adsorbed analyte was then eluted with 5?mL of hydrochloric acid and was determined by flame atomic absorption spectrometery. The speciation of chromium was affected by first passing the solution through an acidic alumina column which retained Cr(VI) and then Cr(III) was preconcentrated by immobilised ferron column and determined by FAAS. The concentration of Cr(VI) was determined from the difference of concentration of total chromium and Cr(III). The effect of pH, concentration of eluent, flow rate of sample and eluent solution, and foreign ions on the sorption of chromium (III) by immobilised ferron column was investigated. Under the optimised conditions the calibration curve was linear over the range of 2–400?µg?L?1 for 1000?mL preconcentration volume. The detection limit was 0.32?µg?L?1, the preconcentration factor was 400, and the relative standard deviation (%RSD) was 1.9% (at 10?µg?L?1; n?=?7). The method was successfully applied to the determination of chromium species in water samples and total chromium in standard alloys.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号