首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A novel glucose biosensor, based on the modification of well-aligned polypyrrole nanowires array (PPyNWA) with Pt nanoparticles (PtNPs) and subsequent surface adsorption of glucose oxidase (GOx), is described. The distinct differences in the electrochemical properties of PPyNWA–GOx, PPyNWA–PtNPs, and PPyNWA–PtNPs–GOx electrodes were revealed by cyclic voltammetry. In particular, the results obtained for PPyNWA–PtNPs–GOx biosensor showed evidence of direct electron transfer due mainly to modification with PtNPs. Optimum fabrication of the PPyNWA–PtNPs–GOx biosensor for both potentiometric and amperometric detection of glucose were achieved with 0.2 M pyrrole, applied current density of 0.1 mA cm−2, polymerization time of 600 s, cyclic deposition of PtNPs from −200 mV to 200 mV, scan rate of 50 mV s−1, and 20 cycles. A sensitivity of 40.5 mV/decade and a linear range of 10 μM to 1000 μM (R2 = 0.9936) were achieved for potentiometric detection, while for amperometric detection a sensitivity of 34.7 μA cm−2 mM−1 at an applied potential of 700 mV and a linear range of 0.1–9 mM (R2 = 0.9977) were achieved. In terms of achievable detection limit, potentiometric detection achieved 5.6 μM of glucose, while amperometric detection achieved 27.7 μM.  相似文献   

2.
Wu B  Zhang G  Shuang S  Choi MM 《Talanta》2004,64(2):546-553
A glucose biosensor using an enzyme-immobilized eggshell membrane and oxygen electrode for glucose determination has been fabricated. Glucose oxidase was covalently immobilized on an eggshell membrane with glutaraldehyde as a cross-linking agent. The glucose biosensor was fabricated by positioning the enzyme-immobilized eggshell membrane on the surface of a dissolved oxygen sensor. The detection scheme was based on the depletion of dissolved oxygen content upon exposure to glucose solution and the decrease in the oxygen level was monitored and related to the glucose concentration. The effect of glutaraldehyde concentration, pH, phosphate buffer concentration and temperature on the response of the glucose biosensor has been studied in detail. Common matrix interferents such as ethanol, d-fructose, citric acid, sodium benzoate, sucrose and l-ascorbic acid did not give significant interference. The resulting sensor exhibited a fast response (100 s), high sensitivity (8.3409 mg L−1 oxygen depletion/mmol L−1 glucose) and good storage stability (85.2% of its initial sensitivity after 4 months). The linear response is 1.0×10−5 to 1.3×10−3 mol L−1 glucose. The glucose content in real samples such as commercial glucose injection preparations and wines was determined, and the results were comparable to the values obtained from a commercial glucose assay kit based on a spectrophotometric method.  相似文献   

3.
Navid Nasirizadeh 《Talanta》2009,80(2):656-661
A highly efficient noradrenalin (NA) biosensor was fabricated on the basis of hematoxylin electrodeposited on a glassy carbon electrode, GCE. The cyclic voltammetric responses of the hematoxylin biosensor at various scan rates, which were obtained in a 0.25 mmol L−1 NA solution, showed the characteristic shape typical of an ECcat process. The kinetic parameters such as electron transfer coefficient, α, the catalytic electron transfer rate constant, k′, and the standard catalytic electron transfer rate constant, k0, for oxidation of NA at the hematoxylin biosensor surface were estimated using cyclic and RDE voltammetry. The peaks of differential pulse voltammetric (DPV) for NA and acetaminophen (AC) oxidation at the hematoxylin biosensor surface were clearly separated from each other when they co-exited in the physiological pH (pH 7.0). It was, therefore, possible to simultaneously determine NA and AC in the samples at a hematoxylin biosensor. Linear calibration curves were obtained for 5.0 × 10−1 to 65.40 μmol L−1 and 65.40-274.20 μmol L−1 of NA, and for 12.00-59.10 μmol L−1 and 59.10-261.70 μmol L−1 of AC. The sensitivities of the biosensor to NA in the absence and presence of AC were found virtually the same, which indicates the fact that the electrocatalytic oxidation processes of NA are independent of AC and, therefore, simultaneous or independent measurements of the two analytes (NA and AC) are possible without any interference. The results of 16 successive measurements show an average voltammetric peak current of 1.13 ± 0.03 μA for an electrolyte solution containing 5.00 μmol L−1 NA. The hematoxylin biosensor has been satisfactorily used for the determination of NA and AC in pharmaceutical formulations. The results obtained, using the biosensor, are in very good agreement with those declared in the label of pharmaceutical inhalation products.  相似文献   

4.
Jianwen Wang  Yifeng Tu 《Talanta》2009,77(4):1454-4466
A novel disposable third-generation hydrogen peroxide (H2O2) biosensor based on horseradish peroxidase (HRP) immobilized on the gold nanoparticles (AuNPs) electrodeposited indium tin oxide (ITO) electrode is investigated. The AuNPs deposited on ITO electrode were characterized by UV-vis, SEM, and electrochemical methods. The AuNPs attached on the ITO electrode surface with quasi-spherical shape and the average size of diameters was about 25 nm with a quite symmetric distribution. The direct electron chemistry of HRP was realized, and the biosensor exhibited excellent performances for the reduction of H2O2. The amperometric response to H2O2 shows a linear relation in the range from 8.0 μmol L−1 to 3.0 mmol L−1 and a detection limit of 2 μmol L−1 (S/N = 3). The value of HRP immobilized on the electrode surface was found to be 0.4 mmol L−1. The biosensor indicates excellent reproducibility, high selectivity and long-term stability.  相似文献   

5.
Zhang F  Li C  Li X  Wang X  Wan Q  Xian Y  Jin L  Yamamoto K 《Talanta》2006,68(4):1353-1358
A reagentless amperometric uric acid biosensor based on zinc sulfide (ZnS) quantum dots (QDs) was firstly developed. It could detect uric acid without the presence of an electron mediator. The carboxyl group functionalized ZnS QDs were synthesized, and they were soluble biocompatible and conductive. ZnS QDs conjugates could provide increased enzyme binding sites, which may result in higher enzyme loading. Thus, the proposed uricase/ZnS QDs/l-cys biosensor exhibited higher amperometric response compared to the one without QDs (uricase/l-cys biosensor). In addition, there was little AA interference. It showed a linear dependence on the uric acid concentration ranging from 5.0 × 10−6 to 2.0 × 10−3 mol L−1 with a detection limit of 2.0 × 10−6 mol L−1 at 3σ.  相似文献   

6.
An electrochemical biosensor for the detection of microcystin has been developed based on the inhibition of the protein phosphatase 2A (PP2A) by this cyanobacterial toxin. The enzyme has been immobilised by entrapment using a poly(vinyl alcohol) azide-unit pendant water-soluble photopolymer (PVA-AWP). Electrode supports and immobilisation conditions have been optimised by colorimetric assays, the highest immobilisation yields being obtained with screen-printed graphite electrodes and the 1:2 PP2A:PVA ratio. Catechyl monophosphate (CMP), α-naphthyl phosphate (α-NP) and 4-methylumbelliferyl phosphate (4-MUP) have been used as phosphorylated substrates to monitor the protein phosphatase activity by electrochemical methods, the former providing the highest chronoamperometric currents at appropriate working potentials (+450 mV versus Ag/AgCl). Incubation with standard microcystin solutions has demonstrated the inhibition of the immobilised enzyme, proportional to the toxin concentration. The standard inhibition curve has provided a 50% inhibition coefficient (IC50) of 83 μg L−1, a limit of detection (LOD; 35% inhibition) of 37 μg L−1, and 100% inhibition at about 1000 μg L−1. Real samples of cyanobacterial blooms from the Tarn River (Midi-Pyrénées, France) have been analysed using the developed amperometric biosensor and the toxin contents have been compared to those obtained by a conventional colorimetric protein phosphatase inhibition (PPI) assay and high-performance liquid chromatography (HPLC). The results clearly justify the use of the developed amperometric biosensor as screening method for microcystin detection.  相似文献   

7.
A novel amperometric biosensor utilizing two enzymes, glucose oxidase (GOD) and horseradish peroxidase (HRP), was developed for the cathodic detection of glucose. The glucose biosensor was constructed by electrochemical formation of a polypyrrole (PPy) membrane in the presence of GOD on the surface of a HRP-modified sol-gel derived-mediated ceramic carbon electrode. Ferrocenecarboxylic acid (FCA) was used as mediator to transfer electron between enzyme and electrode. In the hetero-bilayer configuration of electrode, all enzymes were well immobilized in electrode matrices and showed favorable enzymatic activities. The amperometric detection of glucose was carried out at +0.16 V (versus saturated calomel reference electrode (SCE)) in 0.1 M phosphate buffer solution (pH 6.9) with a linear response range between 8.0×10−5 and 1.3×10−3 M glucose. The biosensor showed a good suppression of interference in the amperometric detection.  相似文献   

8.
Haghighi B  Bozorgzadeh S 《Talanta》2011,85(4):2189-2193
ZnO nanoparticles (nanoZnO) were decorated on multiwalled carbon nanotubes (MWCNTs) and then the prepared nano-hybrids, nanoZnO-MWCNTs, were immobilized on the surface of a glassy carbon electrode (GCE) to fabricate nanoZnO-MWCNTs modified GCE. The prepared electrode, GCE/nanoZnO-MWCNTs, showed excellent electrocatalytic activity towards luminol electrochemiluminescence (ECL) reaction. The electrode was then further modified with lactate oxidase and Nafion to fabricate a highly sensitive ECL lactate biosensor. Two linear dynamic ranges of 0.01-10 μmol L−1 and 10-200 μmol L−1 were obtained for lactate with the correlation coefficient better than 0.9996. The detection limit (S/N = 3) was 4 nmol L−1 lactate. The relative standard deviation for repetitive measurements (n = 6) of 10 μmol L−1 lactate was 1.5%. The fabrication reproducibility for five biosensors prepared and used in different days was 7.4%. The proposed ECL lactate biosensor was used for determination of lactate in human blood plasma samples with satisfactory results.  相似文献   

9.
The potential application of commercial screen-printed gold electrodes (SPGEs) for the trace determination of lead, copper, and mercury in fuel bioethanol is demonstrated. Samples were simply diluted in 0.067 mol L−1 HCl solution prior to square-wave anodic stripping voltammetry (SWASV) measurements recorded with a portable potentiostat. The proposed method presented a low detection limit (<2 μg L−1) for a 240 s deposition time, linear range between 5 and 300 μg L−1, and adequate recovery values (96–104%) for spiked samples. This analytical method shows great promise for on-site trace metal determination in fuel bioethanol once there is no requirement for sample treatment or electrode modification.  相似文献   

10.
This work reports a sequential-injection analysis (SIA) method for the enzymatic assay of glucose with soluble glucose oxidase (GOD) and on-line sample dilution with chemiluminescence (CL) detection. A zone of sample was aspirated in the holding coil of the SIA manifold and, if necessary, was diluted on-line by means of an auxiliary dilution conduit. Then, a zone of GOD was aspirated adjacent to the sample zone and a stopped-flow period was applied to allow the enzymatic reaction to proceed with production of hydrogen peroxide. Then, zones of a catalyst (Co(II) solution) and alkaline luminol were aspirated into the holding coil. Finally, the flow was reversed and the stacked zones were sent to a flow-cell located in front of a photomultiplier tube (PMT) that monitored the CL intensity. The linear dynamic range was 1 × 10−5-1 × 10−3 mol L−1 glucose, the coefficient of variation at 8 × 10−5 mol L−1 of glucose was sr = 3.1% (n = 8), the limit of detection at the 3σ level was cL = 1 × 10−6 mol L−1 and the sampling frequency was 28 h−1. With on-line dilution by a factor of 1/200, the linear range could be extended up to 0.2 mol L−1 glucose. The advantages of the proposed method are the simple manifold and instrumentation used, the scope for automated on-line dilution, the low consumption of sample and reagents and the elimination of enzyme immobilisation procedures. The method was applied to the analysis of commercial drinks and honey with percent relative errors in glucose determination in the range 100 ± 6.1%.  相似文献   

11.
A new nanomaterial was prepared by grafting a layer of sulfonated polyaniline network (SPAN-NW) on to the surface of multi-walled carbon nanotube (MWNT) and effectively utilized for immobilization of an enzyme and for the fabrication of a biosensor. SPAN-NW was formed on the surface of MWNT by polymerizing a mixture of diphenyl amine 4-sulfonic acid (DPASA), 4-vinyl aniline (VA) and 2-acrylamido-2-methyl-1-propane sulfonic acid (APASA) in the presence of amine functionalized MWNT (MWNT-NH2). The MWNT-g-SPAN-NW was immobilized with glucose oxidase (GOx) to fabricate the SPAN-NW/GOx biosensor. MWNT-g-SPAN-NW/GOx electrode showed direct electron transfer (DET) for GOx with a fast heterogeneous electron transfer rate constant (ks) of 4.11 s− 1. The amperometric current response of MWNT-g-SPAN-NW/GOx biosensor shows linearity up to 9 mM of glucose, with a correlation coefficient of 0.99 and a detection limit of 0.11 μM (S/N = 3). At a low applied potential of − 0.1 V, MWNT-g-SPAN-NW/GOx electrode possesses high sensitivity (4.34 μA mM− 1) and reproducibility towards glucose.  相似文献   

12.
Wei J  He JB  Cao SQ  Zhu YW  Wang Y  Hang GP 《Talanta》2010,83(1):190-196
A nonionic poly(2-amino-5-mercapto-thiadiazole) film was electrodeposited on a solid carbon paste electrode via a potential scanning procedure, and used for amperometric sensing of ascorbic acid (AA), dopamine (DA) and serotonin (ST). The highly electrocatalytic activity of the sensor to the three analytes was demonstrated from the sensitive and well separated voltammetric signals. The polymer film did not show significant accumulation effect on all the three species, reducing the fouling and deactivation of the electrode surface as well as the mutual interference among the analytes. The sensor achieved amperometric sensitivities of 1.92 nA (nmol L−1)−1 cm−2 to AA in the linear range of 0.025-1.95 μmol L−1, 3.76 nA (nmol L−1)−1 cm−2 to DA and 7.00 nA (nmol L−1)−1 cm−2 to ST both in the linear range of 0.02-1.56 μmol L−1. The lowest detection limits were found to be 1.5, 0.7 and 0.4 nmol L−1 for AA, DA and ST, respectively. This sensor was successfully employed for the successive determination of AA, DA and ST in pharmaceutical samples. The good antifouling property and reproducibility of the proposed sensor can be attributed to the nonionic polymer film without electrostatic attraction to the ionized species in the solutions.  相似文献   

13.
Zhong H  Yuan R  Chai Y  Li W  Zhong X  Zhang Y 《Talanta》2011,85(1):104-111
A new glucose amperometric biosensor, based on electrodeposition of platinum nanoparticles onto the surface of multi-wall carbon nanotube (MWNT)-polyaniline (PANI) nanocomposites, and then immobilizing glucose oxidase (GOD) with covalent interaction and adsorption effect, was constructed in this paper. Firstly, the MWNT-PANI nanocomposites had been synthesized by in situ polymerization and were characterized through transmission electron microscopy (TEM), Fourier transform infrared (FT-IR) spectroscopy, and ultraviolet and visible (UV-vis) absorption spectra. The assembled process of the modified electrode was probed by scanning electron microscopy (SEM) and cyclic voltammetry (CV). Chronoamperometry was used to study the electrochemical performance of the resulting biosensor. The glucose biosensor exhibited a linear calibration curve over the range from 3.0 μM to 8.2 mM, with a detection limit of 1.0 μM and a high sensitivity of 16.1 μA mM−1. The biosensor also showed a short response time (within 5 s). Furthermore, the reproducibility, stability and interferences of the biosensor were also investigated.  相似文献   

14.
Qu F  Shi A  Yang M  Jiang J  Shen G  Yu R 《Analytica chimica acta》2007,605(1):28-33
Prussian blue nanowire array (PBNWA) was prepared via electrochemical deposition with polycarbonate membrane template for effective modification of glassy carbon electrode. The PBNWA electrode thus obtained was demonstrated to have high-catalytic activity for the electrochemical reduction of hydrogen peroxide in neutral media. This enabled the PBNWA electrode to show rapid response to H2O2 at a low potential of −0.1 V over a wide range of concentrations from 1 × 10−7 M to 5 × 10−2 M with a high sensitivity of 183 μA mM−1 cm−2. Such a low-working potential also substantially improved the selectivity of the PBNWA electrode against most electroactive species such as ascorbic acid and uric acid in physiological media. A detection limit of 5 × 10−8 M was obtained using the PBNWA electrode for H2O2, which compared favorably with most electroanalysis procedures for H2O2. A biosensor toward glucose was then constructed with the PBNWA electrode as the basic electrode by crosslinking glucose oxidase (GOx). The glucose biosensor allowed rapid, selective and sensitive determination of glucose at −0.1 V. The amperometric response exhibited a linear correlation to glucose concentration through an expanded range from 2 × 10−6 M to 1 × 10−2 M, and the response time and detection limit were determined to be 3 s and 1 μM, respectively.  相似文献   

15.
Liu C  Mo YY  Chen ZG  Li X  Li OL  Zhou X 《Analytica chimica acta》2008,621(2):171-177
A new dual detection system for microchip is reported. Both fluorescence detector (FD) and contactless conductivity detector (CCD) were combined together and integrated on a microfluidic chip. They shared a common detection position and responded simultaneously. A blue light-emitting diode was used as excitation source and a small planar photodiode was used to collect the emitted fluorescence in fluorescence detection, which made the device more compact and portable. The coupling of the fluorescence and contactless conductivity modes at the same position of a single separation channel enhanced the detection characterization of sample and offered simultaneous detection information of both fluorescent and charged specimen. The detection conditions of the system were optimized. K+, Na+, fluorescein sodium, fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used to evaluate the performance of the dual detection system. The limits of detection (LOD) of FD for fluorescein Na+, FITC, FITC-labeled arginine (Arg), glycine (Gly) and phenylalanine (Phe) were 0.02 μmol L−1, 0.05 μmol L−1, 0.16 μmol L−1, 0.15 μmol L−1, 0.12 μmol L−1 respectively, and the limits of detection (LOD) of CCD achieved 0.58 μmol L−1 and 0.39 μmol L−1 for K+ and Na+ respectively.  相似文献   

16.
This work reports the preparation of a molecularly imprinted polymer (MIP) for selective catalytic detection of serotonin (5-hydroxytryptamine, 5-HT). The process is based on the synthesis of polymers with hemin introduced as the catalytic center to mimic the active site of peroxidase. The copolymer MIP, containing artificial recognition sites for 5-HT, has been prepared by bulk polymerization using methacrylic acid (MAA) and hemin as the functional monomers, and ethylene glycol dimethacrylate (EGDMA) as the cross-linker. For the determination of 5-HT, a flow injection analysis system coupled to an amperometric detector was optimized using multivariate analysis. The effects of different parameters, such as pH, buffer flow rate, buffer nature, peroxide concentration and sample volume were evaluated. After optimizing the experimental conditions, a linear response range from 1.0 up to 1000.0 μmol L−1 was obtained with a sensitivity of 0.4 nA/μmol L−1. The detection limit was found to be 0.30 μmol L−1, while the precision values (n = 6) evaluated by relative standard deviation (R.S.D.) were, respectively, 1.3 and 1.7% for solutions of 50 and 750 μmol L−1 of 5-HT. No interference was observed by structurally similar compounds (including epinephrine, dopamine and norepinephrine), thus validating the good performance of the imprinted polymer. The method was applied for the determination of 5-HT in spiked blood serum samples.  相似文献   

17.
The construction and performance characteristics of different phosphate ion-selective electrodes are described. Three types of electrodes are demonstrated, namely screen-printed, carbon paste and the conventional PVC membrane electrodes. The cited electrodes are based on bisthiourea ionophores and show a considerable selectivity towards hydrogenphosphate with Nernstian slopes depending on the type of the electrode and the ionophore used. Matrix compositions of each electrode are optimised on the basis of effects of type and concentration of the ionophore as well as influence of the selected plasticizers. The screen-printed electrodes work satisfactorily in the concentration range 10−5 to 10−2 mol L−1 with anionic Nernstian compliance (32.8 mV/decade activity) and detection limit 4.0 × 10−6 mol L−1. The screen-printed electrodes show fast response time of about 2.2 s and exhibit adequate shelf-life (4 months). The fabricated electrodes can be also successfully used in the potentiometric titration of HPO42− with Ba2+.  相似文献   

18.
Feng Li 《Talanta》2009,77(4):1304-1308
A simple and reliable one-pot approach was established for the development of a novel hydrogen peroxide (H2O2) biosensor based on in situ covalent immobilization of horseradish peroxidase (HRP) into biocompatible material through polysaccharide-incorporated sol-gel process. Siloxane with epoxide ring and trimethoxy anchor groups was applied as the bifunctional cross-linker and the inorganic resource for organic-inorganic hybridization. The reactivity between amine groups and epoxy groups allowed the covalent incorporation of HRP and the functional biopolymer, chitosan (CS) into the inorganic polysiloxane network. Some experimental variables, such as mass ratio of siloxane to CS, pH of measuring solution and applied potential for detection were optimized. HRP covalently immobilized in the hybrid matrix possessed high electrocatalytic activity to H2O2 and provided a fast amperometric response. The linear response of the as-prepared biosensor for the determination of H2O2 ranged from 2.0 × 10−7 to 4.6 × 10−5 mol l−1 with a detection limit of 8.1 × 10−8 mol l−1. The apparent Michaelis-Menten constant was determined to be 45.18 μmol l−1. Performance of the biosensor was also evaluated with respect to possible interferences. The fabricated biosensor exhibited high reproducibility and storage stability. The ease of the one-pot covalent immobilization and the biocompatible hybrid matrix serve as a versatile platform for enzyme immobilization and biosensor fabricating.  相似文献   

19.
BiFeO3 magnetic nanoparticles (BFO MNPs) are used as a catalyst to develop an ultrasensitive method for the determination of H2O2. It is found that BFO MNPs can catalyze the decomposition of H2O2 to produce OH radicals, which in turn oxidize the weakly fluorescent benzoic acid to a strongly fluorescent hydroxylated product with a maximum emission at 405 nm. This makes it possible to sensitively quantify traces of H2O2. Under optimized conditions, the fluorescence intensity is observed to be well linearly correlated with H2O2 concentration from 2.0 × 10−8 to 2.0 × 10−5 mol L−1 with a detection limit of 4.5 × 10−9 mol L−1 (S/N = 3). In addition, a selective method for glucose determination is developed by using both glucose oxidase and BFO MNPs, which has a linear range for glucose concentration from 1.0 × 10−6 to 1.0 × 10−4 mol L−1 with a detection limit of 5.0 × 10−7 mol L−1. These new methods have been successfully applied for the determination of H2O2 in rainwater and glucose in human serum samples.  相似文献   

20.
A mass spectrometer was coupled to high-performance ligand-exchange liquid chromatography (HPLEC) for simultaneous analysis of stress associated solutes such as proline, hydroxyproline, methylproline, glycine betaine and trigonelline extracted from leaves of drought stressed oaks and an internal standard namely N-acetylproline. Methanol/chloroform/water extracts were analyzed using an Aminex HPX-87C column and specifically quantified by the positive ion mode of an electrospray ionisation-mass spectrometry (ESI-MS) in single ion monitoring (SIM) mode. The recovery of N-acetyl proline added to oak leaf extracts ranged from 85.2 to 122.1% for an intra-day study. Standard calibration curves showed good linearity in the measured range from 0.3125 to 10 μmol L−1 with the lowest correlation coefficient of 0.99961 for trigonelline. The advantages of this alternative procedure, compared to previously published methods using fluorescence or amperometric detections, are the simultaneous and direct detection of osmoprotectants in a single chromatographic run, a minimal sample preparation, a good specificity and reduced limits of quantification, ranging from 0.1 to 0.6 μmol L−1. Fifty-six days of water deficit exposure resulted in increased foliar free proline levels (2.4-fold, P < 0.001, 155 μmol g−1 FW) and glycine betaine contents (2.5-fold, P < 0.05, 175 μmol g−1 FW) of drought stressed oak compared to control.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号