首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A three-dimensional microchannel network with two-level crossings of channels was constructed in a glass microchip by sandwiching an insulating glass plate between two glass plates with microchannels followed by thermal bonding. Pressure-driven stable multi-phase laminar flows inside the three-dimensional channel network were realized by balancing flow rates of syringe pumps. Micro unit operations for mixing, reaction, solvent extraction, and detection were properly arranged in the multi-phase laminar flows, so that four parallel analyses, comprising twenty unit operations in total, could be integrated onto a single chip. Two chelating reagents and two sample solutions containing heavy metal ions (Fe(ii) or Co(ii)) were mixed and reacted in four different combinations using the three-dimensional channel network. After chelating reactions were completed, post processing (solvent extraction or addition of acid) was applied to each solution stream to remove the interferences of coexisting metal ions. Finally, target metal complexes were detected using a thermal lens microscope (TLM). Integrity of the micro system was confirmed by qualitative analysis of Fe(ii) and Co(ii). This is the first example of continuous flow chemical processing utilizing multi-phase laminar flow realized in a three-dimensional channel network.  相似文献   

2.
Multi-pumping flow systems exploit pulsed flows delivered by solenoid pumps. Their improved performance rely on the enhanced radial mass transport inherent to the pulsed flow, which is a consequence of the establishment of vortices thus a tendency towards turbulent mixing.This paper presents several evidences of turbulent mixing in relation to pulsed flows, such as recorded peak shape, establishment of fluidized beds, exploitation of flow reversal, implementation of relatively slow chemical reactions and/or heating of the reaction medium. In addition, Reynolds number associated with the GO period of a pulsed flow is estimated and photographic images of dispersing samples flowing under laminar regime and pulsed flow conditions are presented.  相似文献   

3.
In this paper we present our first results on the realization of stable water/octanol, two-phase flows inside poly(dimethylsiloxane) (PDMS) microchannels. Native PDMS microchannels were coated with high molecular weight polymers to change the surface properties of the microchannels and thus stabilize the laminar flow profile. The polymers poly(2-hydroxyethyl methacrylate), poly(vinyl pyrrolidone), poly(ethylene oxide), poly(ethylene glycol), and poly(vinyl alcohol) were assessed for their quality as stabilization coatings after deposition from flowing and stationary solutions. Additionally, the influence of coating the microchannels homogeneously with a single kind of polymer or heterogeneously with two different polymers was investigated. From the experimental observations, it can be concluded that homogeneous polymer coatings with poly(2-hydroxyethyl methacrylate) and poly(vinyl pyrrolidone) led to the effective stabilization of laminar water/octanol flows. Furthermore, heterogeneous coatings led to two-phase flows which had a better-defined and more stable interface over long distances (i.e., 40-mm-long microchannels). Finally, the partitioning of fuchsin dye in the coated microchannels was demonstrated, establishing the feasibility of the use of the polymer-coated PDMS microchannels for determination of logP values in laminar octanol/water flows.  相似文献   

4.
基于微型通道自身的层流特点而发展起来的多相层流技术,从最初的液-液微萃取开始,由于其结构加工简单、操作方便和分析功能强大,已逐渐发展成为一种加工分析方法,为微流控分析的研究应用打开了一个崭新的局面。本文概述了层流的基本原理,总结了近10年来在这方面的研究,包括层流界面间的分子扩散、转移现象和化学反应,以及层流刻蚀加工技术及其在制备纳米材料和在生命医学方面的应用。具体介绍了应用层流技术进行微芯片的加工制作,微型反应器的制备,离子、分子的分离分析,聚合物薄膜的形成和应用,微通道内有机合成反应的控制,溶液的浓度梯度控制以及在免疫检测中的应用,对细胞、生物大分子的操作控制,以及对生物试剂的预处理分析等。  相似文献   

5.
微流控层流技术的研究   总被引:5,自引:0,他引:5  
冯颖  王敏 《化学进展》2006,18(7):966-973
基于微型通道自身的层流特点而发展起来的多相层流技术,从最初的液-液微萃取开始,由于其结构加工简单、操作方便和分析功能强大,已逐渐发展成为一种加工分析方法,为微流控分析的研究应用打开了一个崭新的局面。本文概述了层流的基本原理,总结了近10年来在这方面的研究,包括层流界面间的分子扩散、转移现象和化学反应,以及层流刻蚀加工技术及其在制备纳米材料和在生命医学方面的应用。具体介绍了应用层流技术进行微芯片的加工制作,微型反应器的制备,离子、分子的分离分析,聚合物薄膜的形成和应用,微通道内有机合成反应的控制,溶液的浓度梯度控制以及在免疫检测中的应用,对细胞、生物大分子的操作控制,以及对生物试剂的预处理分析等。  相似文献   

6.
In the microchannels made of hydrophobic materials, the fluid velocity is determined by the zeta potential and velocity slip, both of which may be inhomogeneous due to the adsorption of protein to the channel wall. The inhomogeneity of zeta potential and slip coefficient sometimes causes recirculating flows which in turn affect the transport and mixing of solutes through the microchannels. In the present investigation we devise a method for the simultaneous estimation of inhomogeneous zeta potential and inhomogeneous slip coefficient using velocity measurements. A conjugate gradient method supplemented by the adjoint variable method is adopted in the solution of the relevant inverse problem to reduce the computational burden. The present method is found to estimate the inhomogeneous zeta potential and the slip coefficient simultaneously even with noisy velocity measurements. This method is expected to contribute to the optimal design and robust operation of various microfluidic devices, where the flow patterns and the volumetric flow rates are critically influenced by the profiles of inhomogeneous zeta potential and inhomogeneous slip coefficient.  相似文献   

7.
A novel microfluidic chip with simple design, easy fabrication and low cost, coupled with high-sensitive laser induced fluorescence detection, was developed to provide continuous single-cell analysis based on dynamic cell manipulation in flowing streams. Making use of laminar flows, which formed in microchannels, single cells were aligned and continuously introduced into the sample channel and then detection channel in the chip. In order to rapidly lyse the moving cells and completely transport cellular contents into the detection channel, the angle of the side-flow channels, the asymmetric design of the channels, and the number, shape and layout of micro-obstacles were optimized for effectively redistributing and mixing the laminar flows of single cells suspension, cell lysing reagent and detection buffer. The optimized microfluidic chip was an asymmetric structure of three microchannels, with three microcylinders at the proper positions in the intersections of channels. The microchip was evaluated by detection of anticancer drug doxorubicin (DOX) uptake and membrane surface P-glycoprotein (P-gp) expression in single leukemia K562 cells. An average throughput of 6–8 cells min−1 was achieved. The detection results showed the cellular heterogeneity in DOX uptake and surface P-gp expression within K562 cells. Our researches demonstrated the feasibility and simplicity of the newly developed microfluidic chip for chemical single-cell analysis.  相似文献   

8.
Fluid mixing in planar spiral microchannels   总被引:1,自引:0,他引:1  
Mixing of fluids at the microscale poses a variety of challenges, many of which arise from the fact that molecular diffusion is the dominant transport mechanism in the laminar flow regime. While considerable progress has been made toward developing strategies to achieve improved mixing in microfluidic systems, many of these techniques introduce additional complexity to device fabrication and/or operation processes. In this work, we explore the use of compact spiral-shaped flow geometries designed to achieve efficient mixing in a format that can be constructed using a single planar soft lithography step without the need for multilayer alignment. A series of 150 microm-wide by 29 microm-tall channels were constructed, each of which incorporated a series of spiral shaped sections arrayed along the flow path. Five spiral designs with varying channel lengths were investigated, and mixing studies were carried out at flow rates corresponding to Reynolds numbers ranging from 0.02 to 18.6. Under appropriate conditions, transverse Dean flows are induced that augment diffusive transport and promote enhanced mixing in considerably shorter downstream distances as compared with conventional planar straight channel designs. Mixing efficiency can be further enhanced by incorporating expansion vortex effects via abrupt changes in cross-sectional area along the flow path.  相似文献   

9.
Various micro surface‐modification approaches including photolithography, dip‐pen lithography and ink‐jet systems have been developed and used to extend the functionalities of solid surfaces. While those approaches work in the “open space”, push–pull systems which work in solutions have recently drawn considerable attention. However, the confining flows performed by push–pull systems have realized only the dispense process, while microscale, region‐selective chemical reactions have remained unattainable. This study reports a microchemical pen that enables region‐selective chemical reactions for the micro surface modification/patterning. The chemical pen is based on the principle of microfluidic laminar flows and the resulting mixing of reagents by the mutual diffusion. The tiny diffusion layer performs as the working region. This report represents the first demonstration of an open microreactor in which two different reagents react on a real solid sample. The multifunctional characteristics of the microchemical pen are confirmed by different types of reactions in many research areas, including inorganic chemistry, polymer science, electrochemistry and biological sample treatment.  相似文献   

10.
This paper has addressed analytically the problem of laminar flow in microchannels with rectangular cross-section subjected to a time-dependent sinusoidal pressure gradient and a sinusoidal electric field. The analytical solution has been determined based on the Debye-Hückel approximation of a low surface potential at the channel wall. We have demonstrated that Onsager's principle of reciprocity is valid for this problem. Parametric studies of streaming potential have shown the dependence of the electroviscous effect not only on the Debye length, but also on the oscillation frequency and the microchannel width. Parametric studies of electroosmosis demonstrate that the flow rate decreases due to an increase in frequency. The obtained solutions for both the streaming potential and electroosmotic flows become those for flow between two parallel plates in the limit of a large aspect ratio.  相似文献   

11.
The mixing process of ternary solvents (water-hydrophilic/hydrophobic organic mixture) prepared in microchannels in a microchip was examined by fluorescence observation of the dyes dissolved in the solvents under laminar flow conditions. A microchip incorporating microchannels was used. In it, three narrow channels were combined to form one wide channel. Water-acetonitrile (hydrophilic) mixture containing relatively hydrophilic Eosin Y (green) was fed into the narrow center channel and an acetonitrile-ethyl acetate (hydrophobic) mixture containing hydrophobic perylene (blue) was fed into the two narrow side channels in the microchip. The mixtures in the narrow channels combined in the wide channel to prepare the ternary solvents of water-acetonitrile-ethyl acetate, causing the tube radial distribution of the solvents. We observed the mixing process of the ternary solvents in the wide channel through fluorescence of the green and blue dyes, including an aqueous-organic interface. For example, the green dye that was fed into the center channel was distributed near the inner side walls and the blue dye that was fed into the two side channels was distributed around the center area in the wide channel. Such specific mixing behavior was not observed for two-component solvents in the wide channel, such as water-acetonitrile mixture and water-ethyl acetate mixture.  相似文献   

12.
Costin CD  Synovec RE 《Talanta》2002,58(3):551-560
A detection scheme that probes the refractive index gradient (RIG) between adjacent laminar flows in microfluidic devices has been developed and evaluated. The behavior of low Reynolds number flows has been well documented and shows that molecular transport (mixing) between adjacent laminar flows occurs by molecular diffusion between the flow boundaries. A diode laser has been used to probe the transverse concentration gradient at a selected position along a microchannel. The concentration gradient is affected by the transverse diffusion from a flow with analyte into a flow initially without analyte. To optimize sensitivity, the RIG is probed at a position in which molecular diffusion across the boundary of the two flows has been minimal, i.e. just after the flow initially without analyte merges with the flow initially containing the analyte at a given concentration. The RIG formed causes the laser beam, impinging orthogonal to the RIG through the microchannel, to be deflected. The angle of deflection is then monitored on a position sensitive detector (PSD). Currently, this detection scheme is demonstrated to provide quantitative detection of sucrose, as a test analyte, with a concentration limit of detection (LOD) of 96 ppm (w/v) or 280 muM, corresponding to 1.3x10(-5) DeltaRI units using 3sigma baseline noise. A dynamic range of 96 ppm to 50% sucrose is obtained. This detection method provides universal detection selectivity for microfluidic analysis systems that are becoming increasingly useful in monitoring chemical systems, particularly for the polymer, pharmaceutical and life sciences fields. For a larger molecular weight analyte with a smaller diffusion coefficient, lower concentration and RI LODs were achieved since detection sensitivity is a function of analyte diffusion. For example, for the polymer poly (ethylene glycol) with a molar mass of 11 840 g mol(-1), the LOD was experimentally determined to be 56 ppm (4.7 muM), equivalent to a RI LOD of 4.5x10(-6) DeltaRI (3sigma). The detection limit for proteins was also found to be favorable. For example, with the current configuration, ribonuclease A (RNAse) had a LOD of 46 ppm (3.4 muM), and bovine serum albumin (BSA) had a LOD of 54 ppm (780 nM).  相似文献   

13.
在通道壁面垂直施加一个调控电场可以改变双电层电荷密度和Zeta电位势,实现对电渗流的调控.采用电场Poisson方程、动量守恒的Navier-Stokes方程、电解质离子输运的Nernst-Planck方程和液体混合反应的组分浓度输运方程,本文对微通道壁面离散布置调控电极的情况进行了数值分析.数值算例包括单电极、双电极...  相似文献   

14.
Sia SK  Whitesides GM 《Electrophoresis》2003,24(21):3563-3576
This review describes microfluidic systems in poly(dimethylsiloxane) (PDMS) for biological studies. Properties of PDMS that make it a suitable platform for miniaturized biological studies, techniques for fabricating PDMS microstructures, and methods for controlling fluid flow in microchannels are discussed. Biological procedures that have been miniaturized into PDMS-based microdevices include immunoassays, separation of proteins and DNA, sorting and manipulation of cells, studies of cells in microchannels exposed to laminar flows of fluids, and large-scale, combinatorial screening. The review emphasizes the advantages of miniaturization for biological analysis, such as efficiency of the device and special insights into cell biology.  相似文献   

15.
含微混合器的微芯片设计和性能研究   总被引:8,自引:0,他引:8  
微型化分析系统是分析化学的新兴研究领域,研究中设计制作的微芯片,由按层流原理设计制作的交叉分液汇合式微混合器及长反应管道组成。两种荧光染料混合实验可以直观地观测到微混合器的混合效果,而对Hg^2+-若丹明B的荧光猝灭反应的标准曲线法定量分析表明该设计的微芯片可应用于化学反应过程的定量测试。该微芯片在化学与生化分析和合成等分析检测领域具有巨大的潜在应用价值。  相似文献   

16.
Liu AL  He FY  Wang K  Zhou T  Lu Y  Xia XH 《Lab on a chip》2005,5(9):974-978
We developed a facile and rapid one-step technique for design and fabrication of passive micromixers in microfluidic devices using a direct-printing process. A laser printing mechanism was dexterously adopted to pattern the microchannels with different gray levels using vector graphic software. With the present method, periodically ordered specific bas-relief microstructures can be easily fabricated on transparencies by a simple printing process. The size and shape of the resultant microstructures are determined by the gray level of the graphic software and the resolution of the laser printer. Patterns of specific bas-relief microstructures on the floor of a channel act as obstacles in the flow path for advection mixing, which can be used as efficient mixing elements. The mixing effect of the resultant micromixer in microfluidic devices was evaluated using CCD fluorescence spectroscopy. We found that the mixing performance depends strongly on the gray level values. Under optimal conditions, fast passive mixing with our periodic ordered patterns in microfluidic devices has been achieved at the very early stages of the laminar flow. In addition, fabrication of micromixers using the present versatile technique requires less than an hour. The present method is promising for fabrication of micromixers in microfluidic devices at low cost and without complicated devices and environment, providing a simple solution to mixing problems in the micro-total-analysis-systems field.  相似文献   

17.
This Article introduces and experimentally explores a novel self-regulating method for reducing the friction losses in large microchannels at high liquid pressures and large liquid flows, overcoming previous limitations with regard to sustainable liquid pressure on a superhydrophobic surface. Our design of the superhydrophobic channel automatically adjusts the gas pressure in the lubricating air layer to the local liquid pressure in the channel. This is achieved by pneumatically connecting the liquid in the microchannel to the gas-pockets trapped at the channel wall through a pressure feedback channel. When liquid enters the feedback channel, it compresses the air and increases the pressure in the gas-pocket. This reduces the pressure drop over the gas-liquid interface and increases the maximum sustainable liquid pressure. We define a dimensionless figure of merit for superhydropbic flows, W(F) = P(L)D/γ cos(θ(c)), which expresses the fluidic energy carrying capacity of a superhydrophobic microchannel. We experimentally verify that our geometry can sustain three times higher liquid pressure before collapsing, and we measured better friction-reducing properties at higher W(F) values than in previous works. The design is ultimately limited in time by the gas-exchange over the gas-liquid interface at pressures exceeding the Laplace pressure. This method could be applicable for reducing near-wall laminar friction in both micro and macro scale flows.  相似文献   

18.
利用基于场介子格子Boltzman(LB)方法对T形微通道内油-水不互溶两相流动进行了数值模拟.通过静止液滴算例改进该两相流LB模型且验证了模型的有效性,成功数值模拟了T形微通道内油水两相流的五种不同流型.数值模拟结果和实验数据定性和定量吻合很好,表明本文数值方法的有效性.此外,采用改进后的LB两相流模型模拟了不同界面张力和接触角条件下的液滴形成过程,讨论了这两个变量对流型和液滴形状的影响.结果表明LB方法是研究微通道内不互溶两相流的一种有效的数值工具,能够对各种涉及不互溶多相流微流体设备的设计提供指导.  相似文献   

19.
A microfluidic pool structure for cell docking and rapid mixing is described. The pool structure is defined as a microchamber on one structural layer of a bilayer chip and connects with two or more individual microchannels on the other structural layer. In contrast to the turbulent flow in a macroscale pool, laminar streams enter and exit this microfluidic pool structure with definite and controllable direction that may be influenced by the location and geometry of the pool. A simple microfluidic model was used to validate this hypothesis. In this model, a microscale pool structure was made on the lower layer of a chip and connected with three parallel microchannels in the upper layer. Simulation and experimental results indicated that the flow profile within the pool structure was determined by its geometry and location. This could be used as a flow control method and it was simpler than designs based on microvalve, hydraulic pressure, or electrokinetic force, and has some important applications. For example, controllable streams within this structure were used to immobilize biological cells along the microchannel walls. When different solution streams flowed through the pool, rapid diffusion of analytes occurred for short diffusion distance between vertical flow laminas. Furthermore, desired dilution (mixing) ratio could be obtained by controlling the geometry of the microfluidic pool.  相似文献   

20.
Zhu X  Yi Chu L  Chueh BH  Shen M  Hazarika B  Phadke N  Takayama S 《The Analyst》2004,129(11):1026-1031
This paper describes the use of arrays of horizontally-oriented reservoirs to deliver liquids through microchannels at a constant flow rate over extended periods of time (hours to days). The horizontal orientation maintains a constant hydraulic pressure drop across microfluidic channels even as the volumes of liquids within the reservoirs change over time. For a given channel-reservoir system, the magnitude of the flow velocity depends linearly on the height difference between reservoirs. The simple structure and operation mechanism make this pumping system versatile. A one-inlet-one-outlet system was used to continuously deliver media for perfusion cell culture, and an array of inlet reservoirs coupled to an outlet reservoir via microchannels was used to drive flows of multiple laminar streams. The parallel pumping scheme conveniently generated various smooth and step concentration gradients, and allowed evaluation of the effect of colchicine on myoblasts. Since the reservoir arrays are configured to be compatible with commercialized multichannel pipettors designed for 96 well plate handling, this simple pumping scheme is envisioned to be broadly useful for medium to high throughput microfluidic perfusion cell culture assays, cell migration assays, multiple laminar flow drug tests, and any other applications needing multiple microfluidic streams.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号